Frigidaire FAS155P1A1, FAS155P1A2, FAS156P1A1, FAS156P1A2, FAS157P1A1 Installation Guide

...
installation Instructions
for Heavy duty
Please real ALL installations before installing. Two or more people are recommended to install this product. If a new electrical outlet is required, have
the outlet installed by a qualified electrician before installing unit.
Preliminary Instructions
1, Check window opening size- the mounting
parts furnished with this air conditioner are made to install in a wooden sill double-hung
window. The standard parts are for a window
opening of 32"(812 mm) minimum to 43"(1092 mm) maximum width. Open sash to a minimum
of 20" (508 mm), (FIG, 1)
2, Check condition of window- all wood parts
of window must be in good shape and able to
firmly hold the needed screws, If not, make
repairs before installing unit,
3, Check your storm windows- if your storm
window frame does not allow the clearance
required, correct by adding a piece of wood as shown in FIG. 2, or by removing storm window
while room air conditioner is being installed,
(Continued)
FOAM
SASH SEAL
DOUBLE SIDED SEAL
SIDE ACCORDION (RIGHT)
BOLT
1/4,,x11/2,,
MOUNTING BRACKET
END CAP & ANGLE LEVELING LEGS BRACKET
SIDE ACCORDION
(LEFT)
SASH
J
t
20" MIN.
1/2" MIN.
STORMWINDOW FRAME OR OTHER OBSTRUCTION
Fig. 1
SASH
f
I
' t
il 1/2" MIN. 20" MIN.
1/2" MIN. --_i I_-- I
T
% Zct ss
STORMWINDOW FRAME OR ENTIRE STOOL. FASTEN
OTHER OBSTRUCTION WITH TWO NAILS OR
SCREWS.
Fig. 2
P/N:819042102-01
4. CHECKFOR ANYTHING THATCOULD BLOCK AIRFLOW-check area outside of window for
things such as shrubs, trees, or awnings. Inside, besure furniture, drapes, orblinds will not stop proper airflow.
5. Check the available electrical service- power
supply must be the same as that shown on the unit serial nameplate, (See Owner's Guideforserial
plate location.) Power cord is 48"long. Besure you have an outlet near. All models have a 3-prong service plug to provide proper service and safe positive grounding, Do notchange plug in any way. Do not use an adapter plug or an
extension cord. If your present wall outlet does not match your plug, call a qualified electrician to make the needed change,
Avoid fire hazard or
electric shock. Do not use an extension cord or an adaptor plug. Do not remove
any prong from the power cord.
Grounding type wall receptacle
_DDo not, under an-n-_y
circumstances, cut,
/ remove, or bypass J
_e grounding pro_
Power supply cord with 3-prong grounding
plug and current detection device
Tools Required
,/ Flat blade screwdriver ,/ Tape measure
,/ Adjustable wrench or pliers
,/ Pencil ./ Spirit level
,/ Socket wrenches
d Phillips screwdriver J Powerdrilll/8" bit
d Scissors
(]:ssssss>3/4"Screws (10) _ Shutter Clamp(2)
1/4"Screws (23) (_ Gasket(10)
[_ Top Channel(I)
Side Accordion RH(1)
O Lock Washers(4) Side Accordion LH(1)
(_ 1-1/2"xl/4 Bolts(4) _
@ 1/4" Nuts(4)
Sash
_o o o o o o o o o 7
ooooooooo_ool
[_ Mounting
Brackets(2)
Angle
racketsI2t
End Cap & Leveling Legs(2)
Drain Plug(Only for 25K and 28K models)
Seal(l)
Double Sided
Seal(l)
Widow Foam (1)
6. Carefully unpack air conditioner- remove all
packing material. Protect floor or carpet from damage, Two people should be used to move and
install unit,
--2--
NOTE: Surplus screw(s) for spare use.
Window installation
Because the compressor is located on the
controls side of the unit (right side), this side will be heavier and more awkward to manipulate.
Inadequate support on control side of the unit
can result in personal injury and damage to your
unit and property. Therefore, it is recommended
to have someone assist you during the
installation of this unit.
1. Select the Best Location A. Your room air conditioner was designed to
fit easily into a single or double hung window.
However, since window designs vary, it may be necessary to make some modifications for safe
and proper installation.
!
E. Be certain the proper electrical outlet is within reach of the installation. All wiring should be in
accordance with local and national electrical codes.
F. Your unit was designed to evaporate
condensation under normal conditions. However,
under extreme humidity conditions, excess
condensation may cause base pan to overflow to the outside. The unit should be installed where
condensation run-off cannot drip on pedestrians or neighboring properties.
Awning
B. Make sure window and frame is structurally sound and free from dry and rotted wood.
C. For maximum efficiency, install the air conditioner on side of the house or building
which favors more shade than sunlight. If the
unit is in direct sunlight, it is advisable to provide an awning over the unit.
D. Provide sufficient clearance around the cabinet to allow for ample air circulation through
the unit. See (Fig.B). The rear of the unit should be outdoors and not in a garage nor inside of a
building. Keep unit as far away as possible from obstacles and obstructions and at least 30"
above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.
Window opening requirements
(see table below)
Cabinet size
(W*H*D)
Min. Window
opening
Max. Window
opening
Side other
obstruction obstacle,i
Ground
26.5" "18.5" *26.9" 30"
44"
30" Min.
Fig.B
Fence,
wall, or
i3i