Product Information
and Technical Guide
2004 Room Air Conditioners
Safe Servicing Practices 3
ATTENTION SERVICERS!
To get a helping hand, visit the
Frigidaire Web Site at:
http://www.frigidaire.com
User name: service
Password: tips
Model Specifications 4-7
Compressor Overloads 8
Restrictor Tube Data 8
Receptacle Codes 9
Product Dimensions 10
Thermostat Dia
Fan/Blower Diagrams 13-14
Wiring Diagrams 15-17
Troubleshooting 18-20
rams 11-12
5995413183
July 2004
TABLE OF CONTENTS
Safe Servicing Practices ............................................................................................3
Model Specifications ..................................................................................................4-7
Compressor Overload Data .......................................................................................8
Restrictor Tube Data ..................................................................................................8
Receptacle Outlet Codes ...........................................................................................9
Product Dimensions ..................................................................................................10
Control Thermostat Location Diagrams ................................................................... 11-12
Slider Casement ......................................................................................................11
Compact Electronic Control .....................................................................................11
Compact Rotary .......................................................................................................11
Intermediate Top Control Rotary .............................................................................. 11
2004 Heavy Duty Thermostat Locations ..................................................................12
2004 Builder Thermostat Locations .........................................................................12
2004 Slider Thermostat Locations ...........................................................................12
Fan and Blower Location Diagrams .........................................................................13-14
Compact .................................................................................................................13
18.5” - No Side Louvers ........................................................................................... 13
Slider Casement ......................................................................................................13
Motor .....................................................................................................................14
Heavy Duty Top Control ...........................................................................................14
Heavy Duty Side Discharge .....................................................................................14
Wiring Diagrams .........................................................................................................15-17
A232012 .................................................................................................................15
309201101/02 ......................................................................................................... 16
309201102/02 ......................................................................................................... 16
309902101/01 ......................................................................................................... 17
Troubleshooting ......................................................................................................... 18-20
2
SAFE SERVICING PRACTICES - ALL APPLIANCES
To avoid personal injury or property damage, it is important that Safe Servicing
Practices be observed. The following are some limited examples of safe practices.
1. DO NOT attempt a product repair if you doubt your ability to complete it in a safe
and satisfactory manner.
2. Before servicing or moving an appliance
• Remove power cord from electrical outlet, trip circuit breaker to OFF position,
or remove fuse
• Turn off gas supply
• Turn off water supply
3. Never interfere with the proper operation of any safety device.
4. Use only OEM replacement parts cataloged for this appliance.
Substitutions may defeat compliance with safety standards set for home
appliances.
5. GROUNDING: The standard color coding for safety ground wires is GREEN, or
GREEN with YELLOW STRIPES. DO NOT use ground leads as current carrying
conductors. It is EXTREMELY important that the service technician reestablish all
safety grounds prior to completing service. Failure to do so will create an electrical
hazard.
6. Prior to returning the product to service, ensure that
• All electrical connections are correct and secure
• All electrical leads are properly dressed and secured away from sharp edges,
high-temperature components, and moving parts
• All non-insulated electrical terminals, connectors, heaters, etc. are adequately
spaced away from all metal parts and panels
• All safety grounds (both internal and external) are correctly and securely
connected
• All panels are properly and securely reassembled
WARNING
This service manual is intended for use by persons having electrical and mechanical training and
a level of knowledge of these subjects generally considered acceptable in the appliance repair trade.
Electrolux Home Products Inc. cannot be responsible, nor assume any liability, for injury or damage
of any kind arising from the use of this manual.
© 2004 Electrolux Home Products, Inc.
3
FRIGIDAIRE MODEL SPECIFICATIONS
Model FAS156N1A FAS184N2A FAS185N2A FAS186N2A FAS226N2A
Chassis Type
Capacity Features
BTU - Cooling
BTU - Heating
Moisture Removal
EER
Electrical Information
Voltage
Amps - Cooling
Amps - Heating
Watts - Cooling
Watts - Heating
Fuse/Breaker (Amps)
Receptacle Code
Wiring Diagram
Page #
Air Flow System
Capacitor-µ farads
Fan Motor Mfg.
Fan Motor Number
RPM/CMP (EVAP)
High
Medium
Low
Heat Only
Refrigeration System
Compressor Mfg.
Compressor Number
Compressor Type
Overload Protector
Capacitor-µ farads
Refrigerant Charge
Restrictor Tube
Thermostat Type
Installation Instructions
Kit Type
Part Number
Heavy Duty
Top Control
15100
-
3.5
10.7
115
12.5
-
1415
-
15
A
309902101
17
10/370
Heshan
309630615
980/530
-
810/400
-
LG
QK191CAB
Rotary
A363784
60/370
42
A112129
Electronic
A
309000906
Heavy Duty
Top Control
18000/17800
-
5.3
9.7
230/208
8.5/9.0
-
1860/1840
-
15
C
309902101
17
6/440
Heshan
309630613
975/500
-
775/400
-
LG
QJ258KAB
Rotary
A363771
25/440
31.75
A112138
Electronic
A
309000906
Heavy Duty
Top Control
18500/18200
-
5.5
10.7
230/208
7.8/8.5
-
1730/1700
-
15
C
309902101
17
6/450
Heshan
309630613
1000/480
-
800/380
-
LG
QJ250KBA-6A
Rotary
A363789
35/450
36
A112115
Electronic
A
309000906
Heavy Duty
Top Control
18500/18200
-
5.5
10.7
230/208
7.8/8.5
-
1730/1700
-
15
C
309902101
17
6/450
Heshan
309630613
1000/480
-
800/380
-
LG
QJ250KBA-6A
Rotary
A363789
35/450
36
A112115
Electronic
A
309000906
Heavy Duty
Top Control
22000/21600
-
6.5
9.4
230/208
10.5/11.4
-
2340/2300
-
15
C
309902101
17
7.5/450
Heshan
309630614
1115/550
-
925/470
-
LG
QP306KBA
Rotary
Internal
40/450
38.5
A112114
Electronic
A
309000906
Control Thermostat
Location Diagram
Condenser Fan and
Evaporator Blower
Location Diagram
Page 12 Page 12 Page 12 Page 12 Page 12
Page 14 Page 14 Page 14 Page 14 Page 14
4
FRIGIDAIRE MODEL SPECIFICATIONS
Model FAS256N2A FAS296N2A FAH085N1T FAH08EN1T FAH105N1T
Chassis Type
Capacity Features
BTU - Cooling
BTU - Heating
Moisture Removal
EER
Electrical Information
Voltage
Amps - Cooling
Amps - Heating
Watts - Cooling
Watts - Heating
Fuse/Breaker (Amps)
Receptacle Code
Wiring Diagram
Page #
Air Flow System
Capacitor-µ farads
Fan Motor Mfg.
Fan Motor Number
RPM/CMP (EVAP)
High
Medium
Low
Heat Only
Refrigeration System
Compressor Mfg.
Compressor Number
Compressor Type
Overload Protector
Capacitor-µ farads
Refrigerant Charge
Restrictor Tube
Thermostat Type
Installation Instructions
Kit Type
Part Number
Heavy Duty
Top Control
25000/24700
-
7.6
9.4
230/208
12.0/13.0
-
2660/2630
-
20
D
309902101
17
7.5/450
Heshan
309630616
1145/590
-
925/470
-
LG
QP348KBB
Rotary
Internal
40/450
40.5
A112153
Electronic
A
309000906
Heavy Duty
Top Control
28500/28000
-
8.6
8.5
230/208
15.0/16.3
-
3365/3300
-
30
E
309902101
17
7.5/450
Heshan
309630616
1145/570
-
960/475
-
LG
QP425KAA
Rotary
Internal
45/450
41.3
A112156/57-59
Electronic
A
309000906
Builder Line Builder Line Builder Line
8000
-
1.8
9.4
115
7.5
-
850
-
15
A
309201101
16
10/370
Welling
309647503
1130/280
950/230
800/190
-
Matsushita
2R11S3R126A6A
Rotary
309205101
35/370
18.7
A112116
Electronic
T
309636002
8000
4200
1.8
9.4
115
7.5
12
850
1250
15
A
309201102
16
10/370
Welling
309647503
1130/280
950/230
800/190
-
Matsushita
2R11S3R126A6A
Rotary
309205101
35/370
18.7
A112116
Electronic
T
309636002
10000
-
2.8
9.4
115
10
-
1065
-
15
A
309201101
16
10/370
Welling
309647503
1130/280
950/240
800/210
-
LG
QK141CCA
Rotary
A363785
50/370
20.5
A112129
Electronic
T
309636002
Control Thermostat
Location Diagram
Condenser Fan and
Evaporator Blower
Location Diagram
Page 12 Page 12 Page 12 Page 12 Page 12
Page 14 Page 14 Page 14 Page 14 Page 14
5
FRIGIDAIRE MODEL SPECIFICATIONS
Model FAH105N2T FAH10EN2T FAH124N2T FAH12EN2T FAK083N7V
Chassis Type
Capacity Features
BTU - Cooling
BTU - Heating
Moisture Removal
EER
Electrical Information
Voltage
Amps - Cooling
Amps - Heating
Watts - Cooling
Watts - Heating
Fuse/Breaker (Amps)
Receptacle Code
Wiring Diagram
Page #
Air Flow System
Capacitor-µ farads
Fan Motor Mfg.
Fan Motor Number
RPM/CMP (EVAP)
High
Medium
Low
Heat Only
Refrigeration System
Compressor Mfg.
Compressor Number
Compressor Type
Overload Protector
Capacitor-µ farads
Refrigerant Charge
Restrictor Tube
Thermostat Type
Installation Instructions
Kit Type
Part Number
Builder Line Builder Line Builder Line Builder Line Slider
Casement
10000/9800
-
2.8
9.4
230/208
4.7/5.1
-
1060/1045
-
15
C
309201101
16
6/450
Welling
309647501
1130/280
1010/240
880/210
-
LG
QK141KBE
Rotary
A363786
30/450
18.4
A112145
Electronic
T
309636002
10000/9800
10600/8600
2.8
9.4
230/208
4.7/5.1
15.5/14
1060/1045
3450/2800
20
D
309201102
16
6/450
Welling
309647501
1130/280
1010/240
880/210
-
LG
QK141KBE
Rotary
A363786
30/450
18.4
A112145
Electronic
T
309636002
12000/11700
-
3.6
9
230/208
5.9/6.4
-
1335/1300
-
15
C
309201101
16
7.5/450
Welling
309647502
1280/300
1130/260
975/230
-
LG
QK164KBC
Rotary
A363788
30/450
22.6
A112119
Electronic
T
309636002
12000/11700
10600/8600
3.6
9
230/208
5.9/6.4
15.5/14
1335/1300
3450/2800
20
D
309201102
16
7.5/450
Welling
309647502
1280/300
1130/260
975/230
-
LG
QK164KBC
Rotary
A363788
30/450
22.6
A112119
Electronic
T
309636002
8000
-
2.2
10.5
115
6.7
-
760
-
15
A
A232012
15
5/370
Heshan
309646002
1120/240
1000/210
940/190
-
Matsushita
2R11S3R126A2A
Rotary
309205101
35/370
20.11
A112124
Bulb
V
309625802
Control Thermostat
Location Diagram
Condenser Fan and
Evaporator Blower
Location Diagram
Page 12 Page 12 Page 12 Page 12 Page 11
Page 14 Page 14 Page 14 Page 14 Page 13
6