Frigidaire FAM156T1A13, FAM18ET2A12, FAM156T1A12, FAM186T2A10, FAM18ET2A11 Owner’s Manual

...
FRIGIDAIRE
_;!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!_7i!_i_i_i_i_i_i_iiiiiiiii_i_i_ii_i_i_i_i_1i7_7_7__'_i_7i_71_7_7_i_71117_)_i!, _!i!{:i!i
Normal Sounds ,i;i;ii
Air(
www,frigidaire.com
i
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
The power supply cord with this air conditioner contains a current
detection device designed to reduce the risk of fire.
Please refer to the section 'Operation of
Current Device' for details.
[n the event that the power supply cord is
damaged, it cannot be repaired. £t must be
replaced with a cord from the product manufacturer.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
o_ , When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.
:Ifthe air conditioner is to be installed in a window, you will probably want to clean both
iii ii
sides of the glass first. [f the window is a triple-track type with a screen panel included,
remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the
ii
separate installation instructions provided with this manual. Save this manual and the
and rear coils.
Prevent Accidents
E ectrica nformation
; The complete electrical rating of your new room air conditioner is stated on the serial plate.
ii
Grounding Prong
ot, under any
_ov_ circumstances, cut, "
30AO/ remove or bypass the
L_ grounding prong..
This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. Do not insert or place fingers or objects into the air discharge area in the front of the unit. Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord. [f the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
[n the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
Do not operate the air conditioner with wet hands. , Do not pull on the power cord.
Do not drink any water that is drained from the air conditioner.
Refer to the rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. [f the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle. Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug,
DANGER! Avoid Serious Tnjury or Death
2 ©2009 E!ec!ro!ux Home Products, :[nc: A!! r!gh!s reserved.
CAUTION. I Avoid Injury or damage to the unit or other property
o
Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
o
Do not climb on or place objects on outdoor part of the unit. Do not hang objects off the unit.
Do not place containers with liquids on the unit. Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit's installation accessories for any damage. Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place. Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit. Do not use or store flammable gases near the unit.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
Operation of Current
Device
Plugin &
press RESET
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
3. Press the RESET button, Again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is also indi- cated by a light on the plug head).
;;, Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer,
If power supply cord is damaged, it CANNOT be repaired, It MUST be replaced by one obtained from the product manufacturer,
@2009 Electrolux Home Products, Inc. All rights reserved.
J
Product Registration Record Your Hodel and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the serial plate is located on the outside of the cabinet.
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely,
signed and returned to the Frigidaire Company.
Packaging Remove all packaging from inside the carton, along with any
inserts placed into the side louvers.
Remove the plastic ties and foam pad that secure the compressor to the fan shroud (where applicable). See diagram.
foam pad + plastic ties Packing Inserts
_______ ___J ( )
Normal Sounds
Sound of Rus/7/ng Air
At the front of the unit, you may
hear the sound of rushing air being moved by the fan.
Gurgle/Hiss
"Gurgling or hissing" noise may be heard due to refrigerant passing through
evaporator during normal operation.
©2009 Electrolux Home Products, Inc. All rights reserved.
4
H/gt7 p/[ctTed Chatter
Today's high efficiency compressors
may have a high pitched chatter during the cooling cycle.
_ .....
Vibration
Unit may vibrate and make noise because of poor wall or window
construction or incorrect installation.
P/ng/nq or Swish/nq
Droplets of water hitting condenser during normal operation may cause
"pinging or swishing" sounds.
Loading...
+ 9 hidden pages