installation instructions
For Heavy Duty (FAS Models) and
Median (FAM Models) Air Conditioners
Please read ALL instructions before installing. Two people are
recommended to install this product. If a new electrical outlet
is required, have the outlet installed by a qualified electrician
before installing unit, See#5 in Preliminary Instructions
following.
Prelimi nary instru ctions
Do the following before starting to install unit. See illustrations
below.
Check dimenstions of your unit to determine model type:
Heavy duty (FAS) Median (FAM)
Unit Height: 18,5/8" 17.5/8"
Unit Width: 261/2" 231/2"
Min. Window Opening: 19" 181/2"
Min. Window Width: 31" 26 Vj'
Max. Window Width: 43" 40 V2"
WASHERHEAD
LOCKENG SCREW_._._ X
ASSEMBLY
SIDE RETAENER J
FOAM GASKET
(LEFT)
1. Check window opening size- the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung window.The standard parts are for
window dimensions listed above.Open sash to a minimum
of 1g"(483mm). (FIG. 1)
2. Check condition of window- all wood parts of window
must be in good shape and able to firmly hold the needed
screws.if not, make repairs before installing unit.
FIG. 1
_1SASH
19" MIN
1/2" MIN
BRACKET
3. Check your storm windows= if you storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)
FIG. 2
// SASH
f
19"MIN
1112
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
STORM WINDOW FRAME OR WITH TWO NAILS OR
OTHER OBSTRUCTION SCREWS.
P/N 6612990 1162
1
4. CHECK FOR ANYTHING THAT COULD BLOCK
AIRFLOW - check area outside of window for things
such as shrubs, trees, or awnings. Inside, be sure
furniture, drapes, or blinds will not stop proper air flow.
5. Check the available electrical service - power supply must
be the same as that shown on the unit serial nameplate.
(See Owner's Guide for serial plate Iocation.)Power cord
is 48"long. Be sure you have an outlet near.
All models have a 3-prong service plug to provide proper
service and safe positive grouding. Do not change plug in
any way. Do not use an adapter plug. If your present wall
outlet does not match your plug, call a qualified electrician
to make the needed change.
::_i Avoid fire hazard or electric
shock, Do not use an extensioncord or an
adaptor plug. Do not remove any prong
from the power cord.
Tools Required
a large flat blade screwdriver
tape measure
adjustable wrench or pliers
pencil
_/ Level
_/ Socket wrenches
_/ Phillips screwdriver
Hardware (in plastic bag)
LJty.
Locking Screw
Washer Head
For window panels
Head Screw
3/4" Long Hex-
2
Grounding type wall
receptacle
Power supply core
NIth3-prong groundi
plug and current
detection device
6. Carefully unpack air conditioner - remove a!l packing
material. Protect floor or carpet from damage. Two
people should be used to move and install unit.
[_ Safety Lock
_ 1/2" Long Screw
and Iocknut
3/4" Long Flat
Head Bolt and
Locknut
Sill Angle Bracket
locking screw for
top angle, side
Long hex-head
retainer 5116"
Long
4 ea.
2 ea.
2
10
2
"ndow Mounting
g Remove Chassis
1. Pull down front panel and remove filter. (See FIG. 1).
2. Lil_front upwards and place to one side.
3. Locate the four front screws and remove. These screws
will be needed to re-install the front later. (See FIG.2)
4. Pry away front from cabinet sides as per photo (see FIG .3)
5. Gently lift front off unit and place to one side (See FIG.4).
6. Removeshi ppingcrewsfrom top d unit and_tso on theside
by the base if installed.
7. Hold the cabinet while pulling on the base handle, and
carefully remove the unit.
8. Add two foam inserts to holes in top of cabinet where
shipping screws were removed from.
D Install Top Angle
1. Attach foam gasket to top angle above holes as
2. Install top
and Side Bracket
shown in FIG. 6.
FIG. 6
angle and
side retainers
to cabinet as
shown in FIG. 6.
Assemble Window
a Filler Panels
1. Place cabinet on floor, a bench, or a table.
2. Slide 'T' section of window filler panel into side retainer
on the side of the cabinet (see Figures 7-8). Do both
sides.
FIG. 7
PLASTIC WINDOW FILLER
FRAME PANEL
9. Your unit may come with internal packaging.THIS
PACKAGING MUST BE REMOVED PRIOR TO
INSTALLING THE AIR CONDITIONER BACK
INTO THE CABINET. (See FIG. 5).
SIDE
RETAINER
FIG. 8
PLASTIC
FILLER
PANEL
FRAME
LOCKING
HOLE
TOP
VIEW
'T'SECTION WINDOW SCREW
3