Frigidaire FAK124T1V1, FAK124T1V0, FAK104T1V1, FAK085T7V1, FAK085T7V0 Owner’s Manual

...
FRIGIDAIRE
Air Conditioner Featu
operating Instructi(
i¸ J ;;}{} L
!i@@iiii@@iTiiiiiiiiiiiii_i_iiJilMiiiiiiiiiiiiiiiiiiii@iiiiiii
WWWffrigidaireicom [-800_265_8352
ThisUSE&CAREMANUALprovidesspecificoperatinginstructionsforyourmodel.Usetheroomairconditioneronlyas instructedinthisUSE&CAREMANUAL.Theseinstructionsarenotmeanttocovereverypossibleconditionandsituationthat mayoccur.Commonsenseandcautionmustbepracticedwheninstalling,operating,andmaintaininganyappliance.
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk
of fire. Please refer to the section 'Operation of
Current Device' for details. tn the event that the power supply cord is damaged, it cannot be repaired, tt must be replaced with a cord from the product
manufacturer.
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first, tf the window is a triple-track type with a screen panel included,
remove the screen completely before installation. Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
For Your Safety
Prevent Accidents
Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
, Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
Power supply cord with 3-prong grounding
plug and current detection device
receptacle you intend to use isnot adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
......." Do not use an extension cord or an adapter PlUg- ....................................................................................................................................................................
READ THIS SECTION BEFORE ATTEHPTING TO OPERATE AIR CONDITIONER,
Unit must be upright for one hour prior to operating.
Operation of Current
Device
Plug in & press RESET
02009 Electrolux Home Products, Inc. All rights reserved.
The power supply cord contains a current device that senses damage to the power cord. To test
your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
3. Press the RESET button. Again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is also indi- cated by a light on the plug head).
, Do not use this device to turn the unit on or off.
Always make sure the RESETbutton ispushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
, If power supply cord isdamaged, it CANNOTbe repaired. It MUST be replaced by one obtained
from the product manufacturer.
2
Product Registration Record Your Hodei and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the
serial plate is located on the outside of the cabinet.
Model No,
Serial No
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed and returned to the Frigidaire Company.
Normal Sounds
High pitched Chatter
Today's high efficiency compressors
may have a high pitched chatter
during the cooling cycle.
Sound of Rushinq Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan.
Vibration Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
Gurg/e/H/ss
"Gurgling or hissing" noise may be heard
due to refrigerant passing through evaporator during normal operation.
Pinging or Swishinq
-- Droplets of water hitting condenser during normal operation may cause
"pinging or swishing" sounds.
02009 Electrolux Home Products, Inc. All rights reserved.
Air Conditioner Features ELECTRONICCONTROL
Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its functions, then follow the symbol for the functions you
desire. The unit can be controlled by the touch pad alone or with the remote.
ADJUSTS TEM PERATU RE DISPLAYS
SLEEP MODE OR TIME TEMPERATURE/TIME
\
/
/
/
z
/ /
/ /
EXHAUST SELECTOR SETS MODE
CHECK FILTER RESET BUTTON
/
/
ACTIVATES TURNS UNIT SETS FAN TIMER ON OR OFF SPEED
""\\\
/ ,/ \
ON/OFF
ADJUSTS TEMP&
TIME
SETS ACTIVATES MODE TIMER
REMOTE CONTROL
LIGHT
SETS FAN SPEED
FAN
TOUCH PAD
Battery Size: AAA Warning: Do not mix old and new batteries. Do not mix alkaline,
standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
Operating Instructions
The following instructions represent the Touch Pad, the same instructions can be used for the Remote Control.
TO TURN UNIT ON: YOU WILL SEE:
DO THIS:
PRESS ON/OFF
BUTTON
@2009 Electrolux Home Products, Inc. All rights reserved.