Frigidaire FAK124Q1 Installation Instructions Manual

Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance. DO NOT ground to a gas line. If
cold water pipe is interrupted by plastic,
non-m
etallic gaskets, or other insulating materials, DO NOT use for grounding. Check
with a qualified electrician if you are in doub
t as to whether the appliance is properly grounded. DO NOT modify power supply cord plug. If it doe
s not fit outlet, have a proper outlet
installed
by a qualified electrician. DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral, or grounding circuit could result in an elecrtrical shock. DO NOT use an extension cord with this applian
ce.
Failure to follow these instructions could result in electr
ical shock, serious injury, or death.
WARNING
Installation Instructions
For Slider Casement Air Conditioners
NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash,
or installation in a metal CASEMENT window. Modification may be necessary when installing in windows made differently than those shown in these instructions.
A high window accessory kit is available for window heights up to 62" (1575mm). Part # EA103W.
Meeting Electrical Requirements
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.
ELECTRICAL REQUIREMENTS
A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz, AC only, 15 ampere fused electrical supply is required. A time delay fuse or time delay circuit breaker is also required. A separate circuit, serving only this appliance, MUST be provided.
NOTE: If codes permit, and a separate
grounding wire is used; it is recommended that a qualified electrician determine that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating materials.
RECEPTACLE WIRING
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is your responsibility to provide proper and adequate receptacle wiring, installed by a qualified electrician.
P/N 220215A055
SUBJECT PAGE
Mee
ting Electrical Requirements 1
Elec
trical Connection 2
Preparing
For Installation 2 Installing Unit in a Sliding Window 4 Al
ternate Window Jamb Applications 7
Installing Unit in a Casement Window 8
TABLE OF CONTENTS
Recommended grounding method:
For your personal safety, this appliance must be grounded. This air conditioner includes a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock hazard:
-cord must be plugged into a mating 3-prong grounding-type wall receptacle,
-must be grounded in accordance with National Electrical Code (ANSI/NFPA 70­ latest version) and
-all local codes and ordinances. If a mating 3-prong grounding-type wall receptacle is not available, it is the responsibility of the consumer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.
Electrical Connection
Electrical ground is required on this appliance.
Preparing for Installation
For wood-frame casement windows: It may be
necessary to construct a frame, using at least 1-inch thick wood, with a 15-1/2-inch wide opening.
For brick or cement building construction: It may be necessary to put a wood stool strip under AC, for mounting purposes.
Installation Tips
Tools Required
Flat-head screwdriver Phillips-head screwdriver Carpenter's level Tape measure Fine tooth saw Electric or hand drill
WARNING
3 Prong
Grounding
Plug
3 Prong
Grounding
Type
Wall
Receptacle
Grounding
pron
g
Power
Supply Cord
(6
feet long)
2
Failure to adhere to the following precautions could result in personal injury and product damage.
Because this unit weighs about 88 to 105 pounds, it is recommended that you have someone help you when install your new unit, and that you both use proper lifting techniques. Inspect the condition of the window where unit will be installed. Be sure it will support the weight of the unit. This appliance must be installed according to all applicable codes and ordinances. Handle AC with care. AVOID sharp metal fins on front and rear coils. Make sure your AC does not fall during installation. Do not use water collected in the unit for drinking purposes. It is not sanitary.
Knife and scissors Pencil
1. Make sure you have all the necessary parts.
Installation kit contents:
1. Platform (1)
2. Support brace (1)
3. Adjustment bolt (1)
4. Hex flange nut - 1/4" (1)
5. Track seal (1)
6. Side channel seal (1)
7. Foam seal strip/Sash seal
8. Safety bracket (1) 9-11. Screw - #10x2-1/2" flat-head (2), OR Screw - #10xl-3/4" pan-head (2), OR Screw - #10xl" pan-head (2)
12. Screw - #8x3/4" pan head (6)
13. Screw - #8-32x3/4" self-threading (7)
14. Window locking bracket (1)
15. Plastic window panel (1)
16. Side channel (2)
17. Screw - #8x3/8 truss head (6)
18. Panel frame/seal assembly (1)
NOTE: Use scale below to measure length of your
screws. The scale will come in handy when separating screws for installation.
2. Choose a proper sized window, as shown right.
15-1/2 inches minimum width 16-1/4 inches maximum width (for casement windows) 21-1/4 inches minimum height (with window panel retainer) 20-5/16 inches minimum height (window panel retainer removed) 39-7/16 inches maximum height
NOTE: Height measurement must be of a clear
opening above mounting platform. In some cases, due to a variety of stop and track arrangements, the above dimensions may vary slightly. If necessary, installation can be made by alternating window jambs. (See Alternate Window Jamb Applications.) (continued)
IDENTIFY SCREWS BY LENGTH
3
1
9,10,11
8
2
13
12
5
7
17
4
16
14
15
6
18
3
1
16 / inches
4
maximum
width
(casement
windows)
1
15 / inches
2
minimum
width
5
20 / inches
16
minimum
height
7
39 / inches
16
maximum
Height
Loading...