I tallati i structi
for ider Casement
NOTE: These instructions describe installation
in a typical wood framed window with a wood
SLIDE-BY sash, or installation in a metal
CASEMENT window. Modification may be
necessary when installing in windows made
differently than those shown in these instructions.
Ahigh window accessory kit EA 103W is available
for window heights up to 62"(1575mm).
Meeting Electrical Requirements
TABLE OF CONTENTS
SUBJECT PAGE
Meeting Electrical Requirements 1
Electrical Connection 2
Preparing for Installation 2
Sliding Window Installation 4
Casement Window Installation 5
Installation in Wood Window 6
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
DO NOT, UNDERANY CIRCUMSTANCES, REMOVE
THE POWERSUPPLYCORDGROUNDINGPRONG.
NOTE: If codes permit, and a separate grounding
wire is used; it is recommended that a qualified
electrician determine that the grounding path is
adequate and not interrupted by plastic, non-metallic
gaskets, orother insulating materials.
RECEPTACLE WIRING
Receptacle wiring should bea minimumof 14gauge.
Use copper wire only. It is your responsibility to
provide proper and adequate receptacle wiring,
installed bya qualified electrician.
ELECTRICAL REQUIREMENTS
A 115 volt (103minimum, 126maximum), 60Hertz,
AC only, 15 ampere fused electrical supply is
required. A time delay fuse or time delay circuit
breaker is also required. A separate circuit, serving
only this appliance, MUSTbe provided.
P/N
ili

Electrical Connection
Electrical ground is required on this appliance.
Recommended grounding method:
For your personal safety, thisappliancemustbe
grounded. This air conditioner includes a power
supply cord with a 3-prong grounding plug. To
minimize possible electrical shock hazard:
-cord must be plugged into a mating 3-prong
grounding-type wall receptacle,
-must be grounded in accordance with
National Electrical Code (ANSI/NFPA70-
latest version) and
-all local codes and ordinances.
If a mating 3-prong grounding-type wall
receptacle is not available, it is the responsibility
of the consumer to have a properly grounded
3-prong wall receptacle installed by a qualified
electrician.
NOTE: Adamaged powersupply cord CANNOT be
repaired-it MUST be replaced with a new power
supply cord obtained from the product
manufacturer.
Avoid fire hazard or
electric shock. Do notuse an extension
cord or an adaptor plug. Do not remove
any prong from the power cord.
Grounding type wall
receptacle
circumstances, cut,
/ remove, or bypass /
__ _DDo not, under an_yy
Power supply cord
with 3-prong grounding
plug and current
detection device
_he gr°unding Pr°_
NOTE: The rating plate on the unit contains
electrical and other technical data. The rating
plate is located on the right side of the unit.
Preparing for Installation
Installation Tips
For wood-frame casement windows: It may be
necessary to construct a frame, using at least
1-inch thick wood, with a 15-1!2-inch wide
opening.
For brick or cement building construction: It
may be necessary to put awood stool strip under
AC, for mounting purposes.
Tools
Required
®
Flat-head screwdriver
®
Phillips-head screwdriver
tl
Carpenter's level
®
Tape measure
®
Fine tooth saw
II
Electric orhand drill
II
Knife and scissors
o
Pencil
--2--