Frigidaire FAK085P7V1, FAK107P1V1 Installation Guide

I tallati i structi
for ider Casement
NOTE: These instructions describe installation
in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal
CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions. Ahigh window accessory kit EA 103W is available
for window heights up to 62"(1575mm).
Meeting Electrical Requirements
TABLE OF CONTENTS
SUBJECT PAGE Meeting Electrical Requirements 1
Electrical Connection 2 Preparing for Installation 2
Sliding Window Installation 4 Casement Window Installation 5
Installation in Wood Window 6
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
DO NOT, UNDERANY CIRCUMSTANCES, REMOVE
THE POWERSUPPLYCORDGROUNDINGPRONG.
NOTE: If codes permit, and a separate grounding
wire is used; it is recommended that a qualified electrician determine that the grounding path is
adequate and not interrupted by plastic, non-metallic gaskets, orother insulating materials.
RECEPTACLE WIRING Receptacle wiring should bea minimumof 14gauge.
Use copper wire only. It is your responsibility to provide proper and adequate receptacle wiring,
installed bya qualified electrician.
ELECTRICAL REQUIREMENTS A 115 volt (103minimum, 126maximum), 60Hertz, AC only, 15 ampere fused electrical supply is
required. A time delay fuse or time delay circuit
breaker is also required. A separate circuit, serving only this appliance, MUSTbe provided.
P/N
ili
Electrical Connection
Electrical ground is required on this appliance.
Recommended grounding method:
For your personal safety, thisappliancemustbe grounded. This air conditioner includes a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock hazard:
-cord must be plugged into a mating 3-prong grounding-type wall receptacle,
-must be grounded in accordance with National Electrical Code (ANSI/NFPA70-
latest version) and
-all local codes and ordinances.
If a mating 3-prong grounding-type wall receptacle is not available, it is the responsibility
of the consumer to have a properly grounded 3-prong wall receptacle installed by a qualified
electrician.
NOTE: Adamaged powersupply cord CANNOT be repaired-it MUST be replaced with a new power supply cord obtained from the product
manufacturer.
Avoid fire hazard or
electric shock. Do notuse an extension cord or an adaptor plug. Do not remove
any prong from the power cord.
Grounding type wall receptacle
circumstances, cut,
/ remove, or bypass /
__ _DDo not, under an_yy
Power supply cord with 3-prong grounding plug and current
detection device
_he gr°unding Pr°_
NOTE: The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit.
Preparing for Installation
Installation Tips
For wood-frame casement windows: It may be
necessary to construct a frame, using at least
1-inch thick wood, with a 15-1!2-inch wide
opening.
For brick or cement building construction: It
may be necessary to put awood stool strip under
AC, for mounting purposes.
Tools
Required
®
Flat-head screwdriver
®
Phillips-head screwdriver
tl
Carpenter's level
®
Tape measure
®
Fine tooth saw
II
Electric orhand drill
II
Knife and scissors
o
Pencil
--2--