Frigidaire FAH086S1TA11, FAH086S1TA12, FAH086S1TA13, FAH08ES1TA11, FAH08ES1TA12 Installation Guide

...
Installation instructions
Do This First
(for existing sleeve)
Note that the air conditioner dimensions are: 24.wide,
14½.high, and 18½. deep (without front). Install Air
Conditioner according to these installation instructions to achieve the best performance. Save these installation
instructions for future reference.
You may not need all parts in the kit. Discard unused pans. Qty.
Tapered Spacer Blocks 17,,Long 2 Centering/Support Blocks 4½.x 3½.x 1½. 4
Plastic Divider 1/8" x 4½.x 14½,, 2
Stuffer Seal 1. x 1½"x 84,, 1 Seal 1½.x 1½.x 25,, 3 Seal 1½,,x 1½.x 14,, 2 Seal 1½.x 3/8.x 25. 3
Seal 1½.x 3/8.x 14,, 2 Seal 1" x 3/4.x 14,, 2
Trim Frame (side legs) 2 Trim Frame (top & bottom legs) 2
Ground Wire (green) 1 Nut for grounding screw 1 Grounding Screw 1 Grille (plastic) 1
Grille Aluminum 1 Nuts (plastic) 4
Screw w/washer 4
CAUTION: When installation is complete, replacement unit MUST have a rearward
slope as shown.
REAR
2. Remove old Air Conditioner from wall sleeve and prepare wall sleeve as follows:
-- Clean interior (do not disturb seals).
-- Wall sleeve must be securely fastened in wall before
installing Air Conditioner. Drive more nails or screws through sleeve, into wall, if needed.
-- Repair paint if needed.
3. If not existing, drill a 3/16.clearance hole for ground- ing screw through left side of wall sleeve, in a clear area about 3 inches maximum (to suit) back from front edge
of sleeve as shown below. Next attach ground wire inside
sleeve, using grounding screw, nut washer pull loose
end of ground wire out front of sleeve, and temporarily bend it down and around lower edge of sleeve.
Wall sleeve to unit sleeve grounding
81eeve
L
1/4" 1o 5/16"
J
3/16"
F Hole
How to Install
1. identifythe wall-sleeve brandfor your installation,
fromthe chart below. Brand
White-Westinghouee
Frigidaire
Carrier (52F Series)
General Electric/
Hotpoint
Whirlpool
Fedders/Emerson 27 16¾
Sears/Kenmore 25¾ 16½
Emerson/Fedders 26¾ 15¾
Carrier (51S Series) 25¾ 167/,
Friedrich 27 16¾
NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or
rear flange that serves as a stop for the Air Conditioner.
Wall Sleeve Dimensions
(inches)
Width Height Depth
}25½ 15¼ 17½
26 15%
25¼ 16½
16,
or 22
16'/, 17½
or 23
16¾
or 19¾
18%
15
18%
16¾
4. Prepare the wall sleeve for installation of the new unit per the following Brand instructions.
#1 Emerson #2 Fedders #3 Fedders or Friedrich
#4 General Electric/Hotpoint #5 Sears or Carrier (51S Series) #6 Whirlpool #7 Whirlpool #8 White-Westinghouse/Frigidaire/
Carrier (52F Series)
#9 White-Westinghouse/Frigidaire
5. Install new unit into wall sleeve.
6. To attach ground wire to the new unit, remove the
screw from the left side front.
15"Deep
l_A,,Deep
16¾,,Deep 16¼,,Deep
18%,,Deep
17'_,,Deep
23.Deep 16,,+ 17½.Deep
22"Deep
7.Assemble and installthe
Trim Frame (see instruction).
P/N 66129901165
This unit's increased performance characteristics result from having two rear air intakes,
it is very important that these installation instructions are followed so your unit can operate at maximum
efficiency,
if this is an existing sleeve, and there is an existing rear grille, it needs to be replaced by the ones
shipped with the unit in the accessory kit.
EITHER
1. Remove the existing grille.
2. Place the included aluminum grille towards the rear of the unit.
3. Mark through the hole positions. 4, Drill through the sleeves flanges with a 1/8" drill bit, 5, Attach the new grille with self-threading screws and washers (not included), 6, It is VERY iMPORTANT that the grille is placed exactly as shown,
OR
1, Remove the existing grille.
2, Use Plastic grille and secure to sleeves flanges using existing screws and washers,
2
Wall Sleeve Brands: #1 Emerson
1. Redirectthelouversatthebackofthewallsleeveas shown
4/
TopView
opposite.The useofpliersisrecommended.
2. Attach (1) 1 ½" x 3/8" x 25" longseal in the center at the top of the sleeve. Remove _e backing paper and press
into position.
3, Attach (2) 1 ½" x 3/8" x 14" seals to the left and rightsides
of the sleeve.
4. Cut (2) 1½" x 3/8" x 25_long seals to 14"long each
and attach to the vertical sections of the grilleas shown.
5. Attach (2) 4 ½" x 3 ½" x I !/2"centering/support blocks one on each side wall. Place incenter of side wall with
the tapered end facing the opening.
6. Gently slide unit into sleeve.
7. Before slidingall-the-way back, remove 2rid screw from fronton left side of unit.
8. Remove the plasticwasher from the screw.
9. Screw and attach the other end of the ground wire to the unitas shown in picture. Make sure that the toothed
washer is against the cabinet.
10. Slide the unitcompletely to the rear to ensure a good
seal, making sure the ground wire does not become
tangled.
11. Seal & Frame the unitas described on the last page of these instructions.
15"Deep
3
Wall Sleeve Brands: #2Fedders
19 _" Deep
RearLoavam
ao_\ 3.5 eo. _ 3
TopView
1. Redirect the louvers at the back of the wall sleeve as shown
opposite. The use of pliers is recommended.
/ I_O*
2. Attach (2) 4 ½" x 3 ½" x 1 ½" centering/supportblocks one
on each side wall. Place in center of side wall with the tapered end facing the opening,
3, Cut (2) 17"Tapered Spacer Blocks as shown below into
two pieces.
4, The 4" section is pieced in front of the ribon base with the
tapered end facing the back of the sleeve. The remaining portionwill be placed behind the rib again sloping toward
the rear of the sleeve. This helps induce a rearward elope on bheunit,
5oAttach (1) 1 _" x 3/8" x 25" longseal in the center at the
top of the sleeve. Remove the backing paper and press into position.
6, Attach (2) 1 ½" x 3/8" x 14" seals to the left and rightsides
of the sleeve,
7, Cut (2) 1½" x 3/8" x 25" long seals to 14" long each
and attach to the vertical sections of the grilleas shown.
8. Gently slide unit into sleeve.
9. Before slidingall-the-way back, remove 2nd screw fl'om
front on leftside of unit.
10. Remove the plastic washer from the screw.
11. Screw and attach the other end of the ground wire to
the unitas shown in picture.Make sure that the toothed washer is against the cabinet.
12, Slide the unit completely to the rear to ensure a good seal,
making sure the ground wire does not become tangled.
13, Seal & Frame the unit as described on the last page of
these instructions.
4
Loading...
+ 8 hidden pages