Keep Well This Manual.
Read Rules for Safe Operation and Instructions Carefully.
WINDOW-TYPE
AIR CONDITIONER
2200019260
11o3
1. ELECTRICAL SAFETY RULES .............................................................. 1
2. UNIT PARTS IDENTIFICATION .............................................................. 2
3. POINTS FOR ATTENTION WHEN OPERATING .................................... 3
4. OPERATION PANEL(Cooling only type) ..................................................... 4
OPERATION INSTRUCTION .................................................................. 4
5. CAREAND MAINTENANCE ................................................................... 7
6. WINDOW INSTALLATION INSTRUCTIONS ......................................... 10
7. TROUBLESHOOTING TIPS ................................................................... 15
All wiring must comply with local and national electrical codes and
be installed by a qualified electrician. If you have any questions
regarding the following instructions, contact a qualified electrician.
Never insert your fingers or any foreign objects into the air outlet.
Take special care to warn children of these dangers.
To avoid the possibility of personal injury, be sure to disconnect
power to the unit before installing and/or servicing and/or cleaning.
If the supply cord is damaged, it must be replaced by the manu-
facturer or its service agent or a similar qualified person in order to
avoid a hazard.
1. The power cord is distinguished according to the cord color:
2. For your safety and protection, this unit is grounded through the power cord plug
when plugged into a matching wall outlet. Please contact the manufacturer or its
service agent or a similar qualified person if you want to replace it.
3. Electrical requirement., See the specifications)
4. Be sure that the unit being correctly grounded. The wall outlet should be provided
with reliable earth wire.
5. The unit should be provided with an individual branch circuit and the fuse size
should be same as that of the power cord plug and wall outlet.
1. Front panel
\
\
\
2. Air filter
3. Frame
4. Cabinet
5. Air inlet grille (outdoor side)
6. Air outlet grille
7. Operation panel
8. Power supply and plug
Fig. 1
2
1. During the course of operating, if you have turned off
the unit or changed operation mode from COOLING
MODE to FAN MODE, be sure to keep that state for
at least three minutes before switching to COOLING
MODE again.
2. Attaching the Air Filter
Before starting the air conditioner operation, make
sure that the air filter is well attached. If the unit has
not been used for a long time, it is recommended to
clean the air filter before your using the unit. For
continuous use, clean the air filter at least once every
two weeks.
3. Before turning on the unit, make sure that the air inlet
grille and air outlet grille are not obstructed by
anything.
4. This air conditioner is designed to be operated under conditions as follows:
Outdoor temp.: 18-43°C
Indoortemp.: 21-32°C
Cooling Operation _ The relative humidity of room should be less
than 80%. If the unit is used in a condition with a
relative humidity over 80%, there will be condensed
water on the surface of the unit.
5. Ifthe unit is operated beyond the conditions specified above, it may cause a failure
of the unit.
6. Relocation of the unit:
When changing the installation location of the air conditioner, consult the selling
agent from which you bought your unit.
3
THERMOSTAT SELECTOR
6 OFF
5 7
4 8
u_ k_
2 10 _o,,
I 11
WAITTHREEMINUTESBEFORERESTARTING
CC_L
Fig. 2
1. Pull the top of the operation cover to
open it.
2. Close the operation cover and press
the top until it snaps into the locked
position.
Fig. 3
Don't press or swing the opened
operation cover,
4