Frigidaire FAC127P1A, GAC102P1A - GIBSON 10000BTU 115V 9.2A 9.8E3 SPD 8 WAY AIR DIRECTION1 Installation Instructions Manual

1
Installation Instructions
READ BEFORE INSTALLING UNIT
Compact II Window Mounting
Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG. 1)
Lower sash must open sufficiently to allow a clear vertical opening of 14-1/2 inches (368 mm). Side louvers and the
rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
TOOLS NEEDED:
Phillips Screw Driver Drill (If pilot holes are needed)
Qty.
3/4"screws 7
lock frame 2
sash lock 1
Mounting Hardware
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
NOTE:
SAVE CARTON and these INSTALLATION INSTRUCTIONS for future reference. The carton is the best way to store unit during winter, or when not in use.
Some assembly is required. Please read these instructions carefully.
CAUTION
Fig. A
Fig. B
Fig. C
Fig. E
Fig . F
Fig . G
Fig . D
Before installing the unit, the Left-Hand Louver must be assembled to the unit:
A. Carefully remove power supply
cord from air discharge area (Fig. A).
B. Carefully remove the Left-Hand
Louver Assembly from the discharge area, and then remove it from the plastic bag(Fig. B).
C. With care, pry apart the auger
wheel shaft from the horizontal louver casing, as shown in Fig. C, D & E.
D. Now locate the auger wheel
shaft into the vertical center post (Fig. F).
E. Clip the other end into the
locating slot.
F. Now place the horizontal louver
casing onto the auger wheel shaft, and snap in place (Fig. G).
G. Check the operation by moving
the horizontal louver up and down, and then turn the auger wheel so the vertical louvers rotate.
SZ000357(En) 10/21/2004, 10:42 AM1
2
How to Install
NOTE: Top Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained!
Place unit on floor, a bench or a table. There is a Left and Right Window Filler Panel - be sure to
use the proper panel for each side.When installed the flange for securing the panel in place to the window sill will be facing into the room.
A. Hold the
Accordion Panel in one hand and gently pull back the center to free the open end. See Figure 2.
B. Slide the free end (“I”section) of the panel into the
cabinet as shown in Figures 3A, 3B & 4. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
C. Once the panel
has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Figure 5.
D. Slide the panel all the way in and repeat on the other
side.
NOTE: If storm window blocks AC, see FIG. 12.
Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the
bottom of the air conditioner frame is against the window sill (FIG. 6 & FIG. 6A). Carefully close the window behind the top rail of the unit.
Extend the side panels out against the window frame (FIG. 7).
1
2
3
FIG. 2
FIG. 3A
FIG. 3B
FIG. 7
FIG. 5
FIG. 4
SZ000357(En) 10/21/2004, 10:42 AM2
FIG. 6
FIG. 6A