PERFORMANCE DATA SHEET
Model: PureSource Ultra-U Using Replacement Cartridge EPTWFU01
APPLICATION GUIDELINES / CONDITIONS OF USE
Water Supply Potable Water Water Temp. Max. 100°F (38°C), Min. 33°F (0.6°C) Water Pressure 30 - 100 psi (206.8 - 689.5 kPa) Service Flow 0.65 gpm maximum (2.46 lpm)
It is essential that the manufacturer’s recommended installation, maintenance and lter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.
• While testing was performed under standard laboratory conditions, actual performance may vary.
or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI Standard 42, Standard 53
and Standard 401.
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.
Emerging compounds/incidental contaminants are those compounds that have been detected in drinking water sup­plies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/percep­tion of drinking water quality.
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system.
Your Water Filtration system will withstand up to 100 pounds per square inch (psi) water pressure.
To reduce the risk associated with choking:
DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after use of the system. Systems certied for cyst reduction may be used on disinfected water that may contain lterable cysts.
Substance Reduction
Average
Inuent
NSF/ANSI Specied
Challenge Concentration
Average % Reduction/
Minimum
Average Product
Water Concentration
REPLACEMENT CARTRIDGE INFORMATION
Replacement Element: EPTWFU01. For estimated cost of replacement ele-
ments please call 1-800-599-7569 or visit us on the web at http://www.frigidaire-store.com/waterlters.html
PERFORMANCE DATA
MODEL: PureSource Ultra-U. Use the replacement cartridge EPTWFU01.
SYSTEM SPECIFICATIONS
Capacity 200 gallons (757 liters)
System tested and certied by NSF International against NSF/ANSI
Standard 42, Standard 53, and Standard 401 for the reduction of substances listed below.
CAUTION
To reduce the risk associated with property damage due to water
leakage or ooding:
• Read and follow Use Instructions before installation and use of this system.
Change the disposable lter cartridge at the recommended interval; the
disposable lter cartridge MUST be replaced every 6 months or sooner.
Failure to replace the disposable lter cartridge at recommended intervals may lead to reduced lter performance and failure of the lter, causing property damage from water leakage or ooding.
• Installation and use MUST comply with all state and local plumbing codes.
Protect from freezing, remove lter cartridge when temperatures are expected to drop below 33° F (4.4° C).
DO NOT install systems in areas where ambient temperatures may go above 110° F (43.3° C).
DO NOT install on hot water supply lines. The maximum operating water
temperature of this lter system is 100°F (37.8°C).
Maximum
Permissible
Concentration
NSF Reduction
Requirements
NSF Test
Report
Reduction
Chlorine 2.0 mg/L 2.0 mg/L ± 10% >97.4 / 97.4% 0.05 mg/L N/A ≥ 50% J-00297278
Nominal Particulate
Class I
Asbestos 290 MFL 10 to 100 MFL; bers greater than 10
Atrazine 8.8 ug/L 9 ug/L ± 10% >94.3 / 94.3% 0.0005 mg/L 5 ug/L N/A J-00297270
Benzene 14 ug/L 15 ug/L ± 10% >96.5 / 96.5% 0.0005 mg/L 0.005 mg/L N/A J-00297271
Carbofuran 80 ug/L 80 ug/L ± 10% >98.8 / 98.8% 0.001 mg/L 40 ug/L N/A J-00297273
Cysts* 140,000
Endrin 5.7 ug/L 6 ug/L ± 10% 96.4 / 94.8% 0.2 ug/L 2 ug/L N/A J-00297646
Lead pH 6.5 150 ug/L 150 ug/L ± 10% 99.6 / 99.3% 0.0005 mg/L 10 ug/L N/A J-00297265
Lead pH 8.5 150 ug/L 150 ug/L ± 10% >99.7 / >99.7% 0.0005 mg/L 10 u/L N/A J-00297266
Lindane 2.0 ug/L 2 ug/L ± 10% >99.0 / 98.9% 0.02 ug/L 0.2 ug/L N/A J-00297274
Mercury @ pH 6.5 5.5 ug/L 6 ug/L ± 10% 96.3 / 96.3% 0.2 ug/L 2 ug/L N/A J-00297268
Mercury @ pH 8.5 5.7 ug/L 6 ug/L ± 10% 94.5 / 89.5% 0.3 ug/L 2 ug/L N/A J-00297267
O-Dichlorobenzene 1800 ug/L 1800 ug/L ±10% >99.9 / 99.9% 0.0005 mg/L 600 ug/L N/A J-00297647
P-Dichlorobenzene 200 ug/L 225 ug/L ± 10% >99.7 / 99.8% 0.5 ug/L 75 ug/L N/A J-00297651
Tetrachloroethylene 14 ug/L 15 ug/L ± 10% >96.4 / 95.8% 0.0005 mg/L 5 ug/L N/A J-00297648
Toxaphene (Pesticide)
2,4-D (Herbicide) 220 ug/L 210 ug/L ± 10% 99.3 / 97.4% 1.6 ug/L 70 ug/L N/A J-00297645
Atenolol 220 ug/L 200 ng/L ± 20% >95.5 / 95.5% 10 ng/L 30 ng/L N/A J-00297275
Bisphenol A 2200 ng/L 2000 ng/L ± 20% >99.1 / 99.1% 20 ng/L 300 ng/L N/A J-00297276
Estrone 140 ng/L 140 ng/L ± 20% >96.6 / 96.4% 5 ng/L 20 ng/L N/A J-00297276
Ibuprofen (Pharma) 440 ng/L 400 ng/L ± 20% >95.5 / 95.3% 20 ng/L 60 ng/L N/A J-00297276
Naproxen 160 ng/L 140 ng/L ± 20% >96.8 / 96.7% 5 ng/L 20 ng/L N/A J-00297276
Nonylphenol 1500 ng/L 1400 ng/L ± 20% >96.7 / 96.6% 50 ng/L 200 ng/L N/A J-00297276
Phenytoin 220 ng/L 200 ng/L ± 20% >95.5 / 95.5% 10 ng/L 30 ng/L N/A J-00297276
Trimethoprim 140 ng/L 140 ng/L ± 20% >96.6 / 96.5% 5 ng/L 20 ng/L N/A J-00297275
4,600,000
pts/mL
cycst/L
15 ug/L 15 ug/L ± 10% >93.2 / 93.1% 0.001 mg/L 3 ug/L N/A J-00297649
At least 10,000 particles/mL 99.3 / 99.0% 38,000 pts/ml N/A ≥85% J-00297279
µm in length
Minimum 50,000 cysts/L >99.99 /
>99 / >99% < 1MLF N/A ≥99% J-00297237
99.99%
<1 cyst/L N/A ≥99.95% J-00297235
* Based on the use of Cryptosporidium parvum oocystsContaminant reduction determined by NSF testing.
10200 David Taylor Drive, Charlotte, NC 28262, 2008 ELECTROLUX HOME PRODUCTS, INC. 1-877-435- 3287 NSF is a trademark of NSF International.
P/N: A02536406
PERFORMANCE DATA SHEET
Model: PureSource Ultra-M Using Replacement Cartridge EPTWFU01
APPLICATION GUIDELINES / CONDITIONS OF USE
Water Supply Potable Water Water Temp. Max. 100°F (38°C), Min. 33°F (0.6°C) Water Pressure 30 - 100 psi (206.8 - 689.5 kPa) Service Flow 0.65 gpm maximum (2.46 lpm)
It is essential that the manufacturer’s recommended installation, maintenance and lter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.
• While testing was performed under standard laboratory conditions, actual performance may vary.
• The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI Standard 42, Standard
53 and Standard 401.
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.
Emerging compounds/incidental contaminants are those compounds that have been detected in drinking water sup­plies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/percep­tion of drinking water quality.
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system.
Your Water Filtration system will withstand up to 100 pounds per square inch (psi) water pressure.
To reduce the risk associated with choking:
DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after use of the system. Systems certied for cyst reduction may be used on disinfected water that may contain
lterable cysts.
Substance Reduction
Average
Inuent
NSF/ANSI Specied
Challenge
Concentration
Average % Reduction/
Minimum
Average Product
Water
Concentration
REPLACEMENT CARTRIDGE INFORMATION
Replacement Element: EPTWFU01. For estimated cost of replacement
elements please call 1-800-599-7569 or visit us on the web at http://www. frigidaire-store.com/waterlters.html
PERFORMANCE DATA
MODEL: PureSource Ultra-M. Use the replacement cartridge EPTWFU01.
SYSTEM SPECIFICATIONS
Capacity 125 gallons (473 liters)
System tested and certied by NSF International against NSF/ANSI
Standard 42, Standard 53, and Standard 401 for the reduc­tion of substances listed below.
CAUTION
To reduce the risk associated with property damage due to water
leakage or ooding:
• Read and follow Use Instructions before installation and use of this system.
Change the disposable lter cartridge at the recommended interval; the
disposable lter cartridge MUST be replaced every 6 months or sooner.
Failure to replace the disposable lter cartridge at recommended intervals may lead to reduced lter performance and failure of the lter, causing property damage from water leakage or ooding.
• Installation and use MUST comply with all state and local plumbing codes.
Protect from freezing, remove lter cartridge when temperatures are expected to drop below 33° F (4.4° C).
DO NOT install systems in areas where ambient temperatures may go above 110° F (43.3° C).
DO NOT install on hot water supply lines. The maximum operating water
temperature of this lter system is 100°F (37.8°C).
Maximum Permissible
Concentration
NSF Reduction
Requirements
NSF Test
Report
Reduction
Chlorine 2.0 mg/L 2.0 mg/L ± 10% >97.4 / 97.4% 0.05 mg/L N/A ≥ 50% J-00297278
Nominal Particulate
Class I
Asbestos 290 MFL 10 to 100 MFL; bers greater than 10
Atrazine 8.8 ug/L 9 ug/L ± 10% >94.3 / 94.3% 0.5 ug/L 3 ug/L N/A J-00297270
Benzene 14 ug/L 15 ug/L ± 10% >96.5 / 96.5% 0.5 ug/L 5 ug/L N/A J-00297271
Carbofuran 80 ug/L 80 ug/L ± 10% >98.8 / 98.8% 1 ug/L 40 ug/L N/A J-00297273
Cysts* 140,000
Endrin 5.7 ug/L 6 ug/L ± 10% 96.4 / 94.8% 0.2 ug/L 2 ug/L N/A J-00297646
Lead pH 6.5 150 ug/l 150 ug/L ± 10% 99.6 / 99.3% 0.5 ug/L 10 ug/L N/A J-00297265
Lead pH 8.5 150 ug/l 150 ug/L ± 10% >99.7 / >99.7% 0.5 ug/L 10 ug/L N/A J-00297266
Lindane 2.0 ug/L 2 ug/L ± 10% >99.0 / 98.9% 0.02 ug/L 0.2 ug/L N/A J-00297274
Mercury pH 6.5 5.5 ug/L 6 ug/L ± 10% 96.3 / 96.3% 0.2 ug/L 2 ug/L N/A J-00297268
Mercury pH 8.5 5.7 ug/L 6 ug/L ± 10% 94.5 / 89.5% 0.3 ug/L 2 ug/L N/A J-00297267
O-Dichlorobenzene 1800 ug/L 1800 ug/L ±10% >99.9 / 99.9% 0.5 ug/L 600 ug/L N/A J-00297647
P-Dichlorobenzene 200 ug/l 225 ug/L ± 10% >99.7 / 99.8% 0.5 ug/L 75 ug/L N/A J-00297651
Tetrachloroethylene 14 ug/L 15 ug/L ± 10% >96.4 / 95.8% 0.5 ug/L 5 ug/L N/A J-00297648
Toxaphene (Pesticide) 15 ug/L 15 ug/L ± 10% >93.2 / 93.1% 1 ug/L 3 ug/L N/A J-00297649
2,4-D (Herbicide) 220 ug/L 210 ug/L ± 10% 99.3 / 97.4% 1.6 ug/L 70 ug/L N/A J-00297645
Atenolol 220 ug/L 200 ng/L ± 20% >95.5 / 95.5% 10 ng/L 30 ng/L N/A J-00297275
Bisphenol A 2200 ng/L 2000 ng/L ± 20% >99.1 / 99.1% 20 ng/L 300 ng/L N/A J-00297276
Estrone 140 ng/L 140 ng/L ± 20% >96.6 / 96.4% 5 ng/L 20 ng/L N/A J-00297276
Ibuprofen (Pharma) 440 ng/L 400 ng/L ± 20% >95.5 / 95.3% 20 ng/L 60 ng/L N/A J-00297276
Naproxen 160 ng/L 140 ng/L ± 20% >96.8 / 96.7% 5 ng/L 20 ng/L N/A J-00297276
Nonylphenol 1500 ng/L 1400 ng/L ± 20% >96.7 / 96.6% 50 ng/L 200 ng/L N/A J-00297276
Phenytoin 220 ng/L 200 ng/L ± 20% >95.5 / 95.5% 10 ng/L 30 ng/L N/A J-00297276
Trimethoprim 140 ng/L 140 ng/L ± 20% >96.6 / 96.5% 5 ng/L 20 ng/L N/A J-00297275
4,600,000
pts/mL
cycst/L
At least 10,000 particles/mL 99.3 / 99.0% 38,000 pts/ml N/A ≥85% J-00297279
µm in length
Minimum 50,000 cysts/L >99.99 /
>99 / >99% < 1MLF N/A ≥99% J-00297237
99.99%
<1 cyst/L N/A ≥99.95% J-00297235
* Based on the use of Cryptosporidium parvum oocystsContaminant reduction determined by NSF testing.