Frigidaire CRA07EPU113, CRA07EPU112, CRA073PU113, CRA053PU113, CRA053PU112 Owner’s Manual

...
F GIDAIRE
Normal Soun
www,frigi
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
Power supply cord
with 3-prong grounding
plug and current
detection device
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
For Your Safety
Prevent Accidents
Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet.
o If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first.
Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in
removing or reinstalling this unit.
Electrical Information
The complete electrical rating of your new protable air conditioner is stated on the serial
ii ii
plate. Refer to the rating when checking the electrical requirements.
ii
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
ii'
proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
ii,
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse
ii
or circuit breaker, have a qualified electrician install the proper receptacle.
ii =
Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
DANGER.I Avoid Serious Injury or Death
This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. Do not insert or place fingers or objects into the air discharge area on top of the unit.
Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box. Do not cut or damage the power cord. If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
Do not operate the air conditioner with wet hands.
Do not pull on the power cord. Do not drink any water that is drained from the air conditioner.
02009 Electrolux Home Products, Inc. All rights reserved.
CAUTION. I Avoid Injury or damage to the unit or other property
o
Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
o
Do not climb on or place objects on the unit. Do not hang objects off the unit.
Do not place containers with liquids on the unit. Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit's installation accessories for any damage. Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place. Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit. Do not use or store flammable gases near the unit.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
Operation of Current Device
Plug in & press RESET
The power supply cord contains a current device that senses damage to the power cord. To test
your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESETbutton pops out.
3. Press the RESET button, Again you will notice a click as the button engages,
4. The power supply cord is now supplying electricity to the unit,
. Do not use this device to turn the unit on or off.
Always make sure the RESETbutton is pushed in for correct operation. The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
' If power supply cord is damaged, it CANNOT be repaired, It MUST be replaced by one obtained
from the product manufacturer.
02009 Electrolux Home Products, Inc. All rights reserved.
Product Registration Record Your Model and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the serial plate is located on the side of the cabinet.
Model No.
Serial No.
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely,
signed and returned to the Frigidaire Company.
Normal Sounds
Sound of Rushing Air
At the front of the unit, you may
hear the sound of rushing air being moved by the fan.
High pitched Chatter
Today's high efficiency compressors may have a
high pitched chatter during the cooling cycle.
Gurgle/Hiss
"Gurgling or hissing" noise may be
heard due to refrigerant passing
through evaporator during normal
operation.
Vibration
Unit may vibrate and make noise because of uneven floor.
02009 Electrolux Home Products, Inc. All rights reserved.
Loading...
+ 9 hidden pages