Frigidaire E30MH65QPSA, EI30BM60MSA, EI30BM60MSB, EI30BM6CPSA, EI30BM6CPSB Installation Guide

...
Installation
Overthe Range
Instructions
Questions? Call 1-877-435-3287(US) or 1-800-265-8352(Canada)
I
Microwave Oven
BEFORE YOU BEGIN
Read these instructions completely and carefully.
instructions for local inspector's use.
IMPORTANT - Observeall
governing codes and ordinances.
Note to Installer - Be sure to leave these
instructions with the Consumer.
Note to Consumer - Keep these
instructions for flJture reference.
Skill level - Installation of this appliance requires basic mechanical and electrical skills.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
I
READ CAREFU LLY.
KEEP THESE INSTRUCTIONS.
p/n 316902904
January 2014
Installation Instructions
CONTENTS
General information
Important Safety Instructions .................................. 3
Electrical Requirements .......................................... 3
Damage - Shipment/Installation .............................. 4
Parts Included .......................................................... 4
Tools You Will Need ................................................ 5
Mounting Space ...................................................... 5
Step-by-step installation guide
Placement of The Mounting Plate ...................... 6-8
Removing the Mounting Plate ...................... 6
Finding the Wall Studs .................................. 6
Determining Wall Plate Location .................. 7
Aligning the Wall Plate ................................ 8
Adapting Microwave Blower
for Outside Back Exhaust ................ 17-18
Mount the Microwave Oven ................ 19
[] Recirculating ........................................
Attach Mounting Plate to Wall ............ 20
Preparation of Top Cabinet ................ 21
Check Blower Plate ............................ 21
Mount the Microwave Oven .......... 21-22
Installing or Change the
Charcoal Filter .................................... 22
Before You Use Your Microwave .......................... 23
Template Information ............................................. 24
20 _ 2 2
Installation Types ............................................... 9-22
Hood Exhaust .................................................. 10-11
_ Outside Top ............................
Attach Mounting Plate to Wall ............ 12
Preparation of Top Cabinet ................ 13
Adapting Microwave Blower for
Outside top Exhaust .................. 13-14
Checking for Proper Damper
Operation ............................................ 14
Mount the Microwave Oven .......... 14-15
Adjust the Exhaust Adaptor ................ 15
Connecting Ductwork .......................... 15
]Outside Back Exhaust 16-19
Preparing Rear Wall for
Outside Back Exhaust .......................... 16
Remove Blower Plate .............................. 16
Attach Mounting Plate to Wall ............ 17
Exhaust 12-15
Preparation of Top Cabinet ................ 17
EN-2
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
This product requires a three-prong grounded outlet. The installer" must perform a ground continuity check on the power" outlet box before beginning the installation to ensure that the outlet box is properly grounded. If not properly grounded, or" if the outlet box does not meet electrical requirements noted
(under ELECTRICAL REQUIREMENTS), a qualified
electrician should be employed to correct any deficiencies.
CAUTION: For personal
safety, remove house fuse or open circuit breaker before beginning
installation to avoid severe or fatal shock injury.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 63-85 pound
(28.5-38.5 kg) product, plus additional oven loads of
up to 50 pounds (22.7 kg) or a total weight of
113-135 pounds (51.3-61.2 kg).
CAUTION: For personal safety, this product cannot be installed in cabinet arrangements such as an island or a peninsula. It must be mounted to BOTH a top cabinet
AND a wall.
You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is very important to have it replaced with a properly grounded three-prong wall receptacle, installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.
ELECTRICAL REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 15 amps and
1.6 kilowatts. This product must be connected to a
seperate and dedicated supply circuit of the proper voltage and frequency. Wire size must conform to
the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug shotfld be brought to a
seperate and dedicated 15- to 20- ampere branch circtfit single grounded outlet. The outlet box should
be located in the cabinet above the microwave oven. The outlet box and supply circuit should be installed
by a qualifed electrician and conform to the National Electrical Code or the prevailing local code.
NOTE: For easier installation and personal safety, it is
recommended that two people install this product.
IMPORTANT - PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility
of electric shock hazard from this appliance.
Ensureproper groundexists
beforeuse
EN-3
Installation Instructions
DAMAGE--SHIPMENT/ INSTALLATION
If the unit is damaged in shipment, return the
unit to the store in which it was bought for repair
or replacement.
If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
If the unit is damaged by the installer (if other
than the customer), repair or replacement must be made by arrangement between customer
and installer
PARTS INCLUDED
HARDWARE PACKET
PART
Wood Screws
/
(1/4" X 2")
ToggleBolts(and wingnuts)(3/16"x3")
QUANTITY
2
+
PARTS INCLUDED (CONT.)
ADDITIONAL PARTS
PART QUANTITY
TopCabinet
Template
RearWall
Template
Installation Instructions
Use&Care
Manual
Forsome models
Grease
Filters
Sel?AligningMachine Screws(1/4"-28x 31/4'')
!
NylonGrommet
(formetalcabinets)
You will find the installation hardware contained in
a packet with the unit. Check to make sure you have all these parts.
NOTE: Some extra parts are included.
Exhaust adaptor
Glass
Tray
Turntable
Ring
Forsome models
Convection
wire rack
Shelf
EN-4
Installation Instructions
TOOLS YOU WILL NEED
# 1Phillipsscrewdriver
Pencil
f
Tinsnips(forcutting damper,if required)
Gloves
Scissors (tocuttemplate,if necessary)
din:=
Ruleror tapemeasureand
t edge
Electricdrill with s/16",1/2"and%"
drill bits
Carpentersquare (optional)
Fillerblocksor scrap woodpieces,if needed fortop cabinetspacing (usedonrecessedbottom cabinetinstallationsonly)
Saw(saber,holeor keyhole)
Safetygoggles
MOUNTING SPACE
J
3O
_12cm) mlrl.
66" (167.6cm) or Morefrom the Floorto the
Topof the Microwave
BottomEdgeof
CabinetNeedsto
be30" (76.2cm)
or Morefromthe
CookingSurface
)lash
Studfinder or Hammer(optional)
Level
NOTES:
The space between the cabinets must be 30" (76.2 cm)wide and free of obstructions.
If you are going to vent your microwave oven to the outside, see Hood Exhaust Section for
exhaust duct preparation.
When installing the microwave oven beneath smooth, flat cabinets, be careful to follow the
instructions on the top cabinet template for power cord clearance.
As a guide to installation, see page 24 for Mounting Template Information.
Cabinet Cabinet
Ductandmaskingtape
x
EN-5
Installation Instructions
PLACEMENT OF THE MOUNTING PLATE
[] Cut the middle of the outer protective plastic bag to
I-_ REMOVING THE MICROWAVE
OVEN FROM THE CARTON/ REMOVING THE MOUNTING PLATE
Remove the installation instructions,use and care,
exhaust adapter, turntable ring, shelf, glass tray and the small hardware bag. Do not remove
the Styrofoam protecting the front of the oven.
remove the mounting plate
Screws Screws
_r Mounting Plate '_
Small Hardware Bag
Turntable Ring below glass tra
Glass Tray
[] Fold back all 4 carton flaps fully against carton
sides. Then carefully roll the oven and carton over onto the top side. The oven should be resting in
the Styrofoam.
Exhaust Adapter
lelf
Remove the screws from each end of the mounting plate. This plate will be used as the rear wall template
and for mounting. Reinstall the screws into the holes
where they were removed.
I-_ FINDING THE WALL STUDS
[] Pull the carton up and off the oven.
[] Find the studs, using one of the following
methods: A. Stud finder - a magnetic device which
locates nails.
B. Use a hammer to tap lightly across the
mounting surface to find a solid sound. This will indicate a stud location.
_}_ After locating the stud (s), find the center by
probing the wall with a small nail to find the edges of the stud. Then place a mark halfway between the edges. The center of any adjacent studs should
be 16" (40.6 cm) or 24" (61 cm) from this mark.
[] Draw a line down the center of the studs.
THE MICROWAVE MUST BE CONNECTED TO AT LEAST ONE WALL STUD.
EN-6
Installation Instructions
I-_ DETERMINING WALL PLATE LOCATION U NDER YOUR CABINET
Plate position-beneath flat bottom cabinet
,'i L L
t
17 1,2,,
i IJ C !ll . .
i_ Iii I Draw a vertical line on
-_ _ the wall at the center of
At least 30" _ the 30" wide space,
Tape the Rear Wall Template onto the wall
matching the centerline and touching the
bottom of the cabinet,
Plate position-beneath recessed bottom cabinet with front overhang
Plate position-beneath framed
recessed cabinet bottom
I
I I I I
I I
30" to Cooktop
Draw a vertical line on the wall at the center of the 30" space.
Tape the Rear Wall Template onto the wall matching the centerline and touching the bottom
cabinet frame.
Your cabinets may have decorative trim that
interferes with the microwave installation. Remove
the decorative trim to install the microwave properly
and to make it level.
Draw a line on the back wall equal to the
depth of the front overhang.
THE MICROWAVE MUST BE LEVEL.
Use a level to make sure the cabinet bottom is level. If the cabinets have a front overhang only, with no
back or side frame, install the mounting plate down the same distance as the front overhang depth. This will keep the microwave level.
I_ Measure the inside depth of the front overhang. I_ Draw a horizontal line on the back wall an equal
distance below the cabinet bottom as the inside depth of the front overhang.
I_ For this type of installation with front overhang
only, align the mounting tabs with this horizontal line, not touching the cabinet bottom as described in Step D.
EN-7
Installation Instructions
ALIGNING THE WALL PLATE
Hole B notches on Wall from Center
!
Horizontal Line
CAUTION: Wear gloves to avoid cutting fingers on
sharp edges.
_!_ Draw a vertical line on the wall at the center of the
30" wide space.
L_JDraw a horizontal line on the wall at the bottom of
"Rear Wall Template".
[_ Find a wall stud in area "E" of mounting plate
Refer to section lB. Finding the wall studs. For attaching the mounting plate into stud drill
a 3/16" hole into wood stud. Drill a 5/8" hole for toggle bolt in 1 other location (Hole A or Hole B)
NOTE: DO NOT MOUNT THE PLATE AT THIS
TIME.
Area E
Centerline Draw a Vertical Line
of Top Cabinet
HoleA Horizontal Line
Draw a horizontal line on wall at the
bottom of "Rear Wall Template".
NOTE: Holes A and B are inside area E. If neither of Holes A and B are not in a stud, find a stud somewhere
in area E and draw a circle to line up with the stud. It is important to have at least one wood screw mounted
firmly in a stud to support the weight of the
microwave. Set the mounting plate aside.
EN-8
Installation Instructions
INSTALLATION TYPES
This microwave oven is designed for adaptation to the following three types of ventilation:
A. Outside Top Exhaust (Vertical Duct) B. Outside Back Exhaust (Horizontal Duct)
C. Recirculating (Non-Vented Ductless)
OUTSIDE TOP EXHAUST (VERTICAL DUCT)
Adaptorin Placefor OutsideTopExhaust
(Choose A, B or C)
NOTE: This microwave is shipped assembled for Recirculating. Select the type of ventilation required for your installation and proceed to that section.
OUTSIDE BACK EXHAUST (HORIZONTAL DUCT)
Adaptor Must Be Moved to the Backfor
OutsideBackExhaust
RECIRCULATING (NON-VENTED DUCTLESS)
NOTE: Read the next two pages only if you plan to vent your exhaust to the outside. If you plan to recirculate the air back into the room, proceed to page 20.
EN-9
Models are shipped for recirculating exhaust.
Some models have a disposable charcoal filter
installed to help remove smoke and odors.
Installation Instructions
INSTALLATION INSTRUCTIONS FOR EXTERNAL EXHAUST DUCTING
NOTE: If you need to install ducts, note that the total
duct length of 31/4" x 10" (8.2 x 25.4 cm) rectangular or 5" (12.7 cm) diameter/ 6" (15.2 cm) diameter round duct
should not exceed 120 equivalent feet (36.5 m). Outside ventilation requires an EXTERNAL EXHAUST
DUCT.Read the following carefully.
NOTE: It is important that venting be installed using
the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.
Exhaust connection:
The exhaust adaptor has been designed to mate with a standard 31/4" x 10" (8.2 x 254 cm) rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. A 5" (12.7cm)/6" (15.2cm)
diameter duct is acceptable to use.
EQUIVALENT
DUCT PIECES
Rectangular-to-Round
TransitionAdaptor*
LENGTH
5 Ft,(1,5m)
Maximum duct length:
For satisfactory air movement, the total duct length of 31/4'' x 10" (8.2 x 25.4 cm) rectangular or 5" (12.7 cm)
diameter/6 "(15.2 cm) diameter round duct should not exceed 120 equivalent feet (36.5 m).
Elbows, transitions, wall and roof caps,
etc., present additional resistance to airflow and are
equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections.
The chart below shows you how to calculate total equivalent ductwork length using the approximate feet
of equivalent length of some typical ducts.
NUMBER
x USED
x ()
EQUIVALENT LENGTH
Ft,orm
J
@
0
J
Wall Cap
90° Elbow
45° Elbow
90° Elbow
45° Elbow
RoofCap
StraightDuct6" (15,2cm) Roundor 31/4``x 10"
(8,2x 25,4cmRectangular)
40Ft,(12,2m)
10Ft,(3m)
5 Ft,(1,5m)
25Ft,(7,6m)
5 Ft,(1,5m)
24Ft,(7,3m)
1 Ft,(0,3m)
x ()
x ()
x ()
x ()
x ()
x ()
x ()
Ft,orm
Ft,orm
Ft,orm
Ft,orm
Ft,orm
Ft,orm
Ft,orm
* IMPORTANT: If a rectangular to round transition
adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.
EN-IO
Total Ductwork
Equivalent lengths of duct pieces are based on actual tests and reflect requirements tot good venting perti}rmance with any vent hood.
Ft. or m
Installation Instructions
EXTERNAL EXHAUST DUCTING
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
EQUIVALENT NUMBER EQUIVALENT
DUCT PIECES
LENGTH x USED = LENGTH
Roof Cap
12Ft,(3,6m)StraightDuct 12 Ft,(3,6m) x (1) = 12 Ft,(3,6m) (6'715,2cmRound)
Rectangular-to-Round 5Ft, (1,5m) x (1) = 5 Ft,(1,5m) TransitionAdaptor*
Equivalentlengthsofductpiecesarebasedonactualtestsand
reflectrequirementsfor goodventingperformancewith anyvent hood,
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, ira order to allow free movement of the damper:
24Ft,(7,3m) x (1) 24Ft,(7,3m)
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible
ductwork installation.
EQUIVALENT NUMBER EQUIVALENT LENGTH* USED = LENGTHDUCT PIECES x
Total Length = 41 Ft. (12.5 m)
_:[_ Cap (12,2m) x
(_ 90° Elbow 10Ft,(3 m) x
Equivalentlengthsof ductpiecesarebasedonactualtests and reflectrequirementsfor goodventingperformancewith anyventhood,
NOTE: For- back exhaust, care should be taken to align exhaust with space between studs, or"wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Wall 40Ft,
3Ft,StraightDuct 3Ft,(0,9m) x (31/i'x 10'78,2x25,4cm
Rectangular)
EN-11
(1) 40Ft,(12,2m)
(1) = 3Ft,(0,9m)
(2) = 20Ft,(3 m)
Total Length = 63 Ft. (19.2 m)
Installation Instructions
F-A OUTSIDE TOP EXHAUST (Vertical Duct)
INSTALLATION OVERVIEW
A1. Attach Mounting Plate to Wall A2. Prepare Top Cabinet
A3. Adapting Microwave Blower for
Outside Top Exhaust
A4. Check Damper Operation A5. Mount Microwave Oven
A6. Adjust Exhaust Adaptor A7. Connect Ductwork
IMPORTANT NOTES:
Make sure the screws for the blower motor and blower plate are securely tightened when
they are reinstalled. This will _ _ ......help to prevent excessive __ ......
vibration.
Make sure the motor wiring has -'_ been properly routed and secured,
and that the wires are not pinched.
_-_ ATTACH THE MOUNTING
PLATE TO THE WALL
W ..... ,t . .
i
Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach
the plate to a wall stud.
_ Remove the from the bolts. _ Insert the bolts into the mounting plate
through the holes designated to go into drywall and reattach the toggle wings to 3/4" (19 mm) onto
each bolt.
toggle wings
IMPORTANT :Do not remove the cardboard
spacers between the heat shield and door.
To use toggle bolts:
Spacing for Toggles More Than Wall
_@,__[____Thickness
I
Mounting
Plate.
_J
_ lace the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure the bottom of the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly
centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers
between the back of the mounting plate and the wall.
_ Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.
lToggle Wings
Bolt End
EN-12
Installation Instructions
I-_ USE TOP CABINET TEMPLATE
FOR PREPARATION OF TOP CABINET
You need to drill holes for the top support screws, a
hole large enough for the power cord to fit through,
and a cutout large enough for the exhaust adaptor.
Read the instructions on the TOP CABINET
TEMPLATE.
Tape it underneath the top cabinet.
Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in the cabinet bottom.
Careflflly pull out the blower unit. The wires will extend far enough to allow you to adjust
the blower unit.
EndA__End B
Microwave
Roll the blower unit 90 ° so that fan blade openings are facing out the top of the
microwave.
Before Rotation After Rotation
Backof Microwave Microwave
ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
TOP EXHAUST
] lace the microwave in its upright position,
with the top of the unit facing up.
Blower Plate
Backof
_-_Microwave
O_
- Blower Motor
Remove the screw that holds the blower plate to the microwave. Remove and save the screw
holding the blower motor to the microwave.
Screw
[]Place the blower unit back into the opening.
Backof Microwave
CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are not pinched, and that they are properly secured.
EN-13
Installation Instructions
ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
TOP EXHAUST
Secure blower unit to microwave with the screw removed in Step 1. Make sure the screw is tight.
Replace blower plate with the screw removed in Step 1. Make sure the screw is tight.
T
I I
Backof
Microwave
Attach the exhaust adaptor to the top of the
[]
blower plate by sliding it into the guides of the blower plate.
Adaptor
k0cking Tab Push in securely until it is in the locking tabs. Take care to assure that the damper hinge is installed so that the damper swings freely.
I-_ MOUNT THE MICROWAVE
OVEN
FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN.
IMPORTANT: Do not grip or use the handle or heat shield during installation. Do not
remove the cardboard spacers between the heat shield and door.
NOTE: If your cabinet is metal, use tim nylon
grommet around the power cord hole to prevent cutting of the cord.
NOTE: We recommend using filler blocks if the
cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are
not used, case damage may occur from overtightening screws.
NOTE: When mounting the
microwave oven, thread power cord through hole in
bottom of top cabinet. Keep
it tight throughout Steps
1-3. Do not pinch cord or
lift oven by pulling cord.
[]Lift tilt it
microwave,
forward, and hook slots at back bottom
edge onto four lower tabs of mounting plate.
I-_ CHECK FOR PROPER
DAMPER OPERATION
Blower Plate Exhaust Adaptor
X ,,_-___----Damper
Make sure tape securing damper is removed and damper pivots easily before mounting microwave.
You will need to make adjustments to assure proper alignment with your house exhaust duct after the
microwave is installed.
[]Rotate front of
up against cabinet bottom.
[]Insert a self-aligning screw through top center
cabinet hole. Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged. (It will be completely tightened later.) Be sure to keep power cord tight. Be careful not to pinch the cord, especially when mounting flush to bottom of cabinet.
EN-14
oven
Installation Instructions
MOUNT THE MICROWAVE OVEN (cont.)
Cabinet Front
Cabinet Bottom Shelf
_ ;Z_._ Filler Block
IT_fflT-,_111-"T Equiva,ent
'/llNt/] [t/I /toDepth
!\\1 IU_-_ Self-Aligning Screw
Microwave OvenTop
[]Attach the microwave oven to the top cabinet.
[] Insert 2 self-aligning screws
through outer top cabinet holes. Turn two full turns on
each screw.
ADJUST THE EXHAUST
ADAPTOR
Open the top cabinet and adjust the exhaust adaptor to connect to the house duct.
Back of
Blower Plate Damper Microwave
Side-to-Side Adjustment, Slide the Exhaust Adaptor
as Needed
I-_ CONNECTING DUCTWORK
House Duct
[] Tighten center
screw completely.
[] Tighten the outer two screws to the top of the
microwave oven. (While tightening screws, hold the microwave oven in place against the wall and the top cabinet.)
[] Install grease filters. See the Owner's IV_anual
packed with the microwave.
H
]Extend the house duct down to connect to
the exhaust adaptor.
}_ eal exhaust duct joints using furnance duct tape
for t_gh temperature applications.
IMPORTANT: Remove the cardhoard spacers between
heat shield and door.
EN-15
Installation Instructions
OUTSIDE BACK EXHAUST (Horizontal Duct)
INSTALLATION OVERVIEW
BI. Prepare Rear Wall B2. Remove Blower Plate
B3. Attach Mounting Plate to Wall B4. Prepare Top Cabinet B5. Adjust Blower
B6. Mount the Microwave Oven
IMPORTANT NOTES:
Make sure the screws for the blower motor and blower plate
are securely tightened when
help to prevent excessive __ ......
vibration.
they are reinstalled. This will _ _ .......
Make sure the motor wiring has been properly routed and secured, and that the wires are not pinched.
PREPARING THE REAR WALL
FOR OUTSIDE BACK EXHAUST
You need to cut an opening in the rear wall for outside exhaust.
IMPORTANT :Do not remove the cardboard spacers between the heat shield and door.
REMOVE BLOWER PLATE
Remove and save the screw that holds the blower plate to the microwave. Lift off the blower plate.
Blower Plate
i
Backof Microwave
Read the instructions on the REAR WALL TEMPLATE.
Tape it to the rear wall.
Cut the opening, following the instructions of the REAR WALL TEMPLATE.
EN-16
Installation Instructions
_] ATTACH THE MOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach
the plate to a wall stud.
]Remove the toggle wings from the bolts.
}_ nsert the bolts into the mounting plate through
the holes designated to go into drywall and reattach the toggle wings to 3/4" (19 mm) onto each bolt.
To use toggle bolts:
USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP
CABINET
You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through.
Read the instructions on the TOP CABINET
TEMPLATE.
Tape it underneath the top cabinet.
Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in the cabinet bottom.
Spacing for Toggles More
_-_i_,---Than Wall Thickness
Mounting
Plate
]Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall to mount the plate.
JoggleWings
Bolt End
NOTE: Before tightening toggle bolts and wood
screw, make sure the bottom of the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly
centered under the cabinet.
CAUTION: Be careflfl to avoid pinching fingers between the back of the mounting plate and the wall.
Tighten all bolts. Pull the plate away from the wall to help tighten the bolts.
ADAPTING MICROWAVE
BLOWER FOR OUTSIDE BACK EXHAUST
[]Remove and that holds blower motor
to microwave.
Careflflly pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
save screw
Blower Motor
"_" - _ Blower Motor
v .,_ Screw
EN-17
EndA
Installation Instructions
ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
BACK EXHAUST (cont.)
[] Roll the blower" unit 90 °
Before Rotation After Rotation
Microwave
Rotate blower unit counterclockwise 180 °.
Before Rotation
Backof Microwave
[]Gently remove the wires from the
Reroute the wires through grooves on other side of the blower unit.
After Rotation
grooves.
Backof Microwave
Microwave
[]Place the blower unit back into the opening.
EndA
End
CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are not pinched, and that they are properly secured.
NOTE: The blower unit exhaust openings should match exhaust
openings on rear of microwave oven.
[ ecure the blower unit to the microwave with
the original screw.
_, Blower Plate
,11_ Microwave
I _ Backof
Blower Motor Screw
Before Rerouting After Rerouting
Wires Routed ThroughRight Side Wires Routed Through Left Side
_6_ Roll the blower unit 90 ° so that fan blade
openings are facing out the back of the microwave.
Before Rolling
Microwave
After Rolling
Back of Microwave
[]Replace the blower in theplate
as before with the screw. Make sure the screw
is tight.
[]Attach the exhaust the of theadaptor
oven by sliding it into the guides at the top
center of the back of the oven.
same
to Fear
Adaptor
o
Guide
Push in securely until it is in the lower locking tabs. Take care to assure that the damper hinge
is installed so that it is at the top and that the damper swings freely.
Locking Tabs
position
Backof Microwave
Guide
EN-18
Installation Instructions
MOUNT THE MICROWAVE OVEN
Cabinet Front
Cabinet Bottom Shelf
Filler Block
Equivalent to Depth of Cabinet
Recess
FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE RECOMMEND THAT TWO PEOPLE
INSTALL THIS MICROWAVE OVEN.
IMPORTANT: Do not grip or use the handle or heat shield during installation. Do not
remove the cardboard spacers between the
heat shield and door.
NOTE: If your cabinet is metal, use the nylon grommet around the power cord hole to prevent cutting of the cord.
NOTE: We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are not used, case damage may occur from
overtightening screws.
NOTE: When mounting the
microwave oven, thread power cord through hole in
bottom of top cabinet. Keep
it tight throughout Steps
1-3. Do not pinch cord or
lift oven by pulling cord.
[]Lift tilt it
microwave,
forward, and hook slots at back bottom
edge onto four lower tabs of mounting plate.
Self-AligningScrew
Microwave OvenTop
[]Attach the microwave oven to the top cabinet.
[] Insert 2 self-aligning screws
through outer top cabinet holes. Turn two full turns on
each screw.
?
u
6_ Tighten center
screw completely.
[] front of
up against cabinet bottom.
[]Insert a self-aligning screw through top center
cabinet hole. Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged. (It will be completely tightened later:) Be sure to keep power cord tight. Be careful not to pinch the cord, especially
when mounting flush to bottom of cabinet.
oven
[] Tighten the outer two screws to the top of the
microwave oven. (While tightening screws, hold the microwave oven in place against the wall and the top cabinet.)
[] Install grease filters. See the Owner's Manual
packed with the microwave.
IMPORTANT: Remove the cardhoard spacers between
heat shield and door.
EN-19
Installation Instructions
RECIRCULATING (Non-Vented Ductless)
INSTALLATION OVERVIEW
C1. Attach Mounting Plate to Wall C2. Prepare Top Cabinet
C3. Check Blower Plate C4. Mount the Microwave Oven
C5. Install or change Charcoal Filter
IMPORTANT NOTES:
Make sure the screws for the blower motor and blower plate are securely tightened when they are reinstalled.
This will help to prevent excessive vibration.
Make sure the motor wiring has been properly route( and secured, and that the wires are not pinched.
IMPORTANT :Do not remove the cardboard spacers between the heat shield and door.
ATTACH THE MOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach
the plate to a wall stud.
NOTE: If the cabinet depth including the cabinet doors
is more than 13" then the unit must be spaced
out from wall using adequate materials supporting
150 Ibs to allow proper top vent air exhaust.
[]Remove the from the bolts.
Insert the bolts into the mounting plate through the holes designated to go into drywall and
reattach the toggle wings to 3/4" (19 mm) onto each bolt.
toggle wings
To use toggle bolts:
Spacing for Toggles More Than Wall
_l_!_,..--Thickness
I
Mounting
Plate
]Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure the bottom of the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly
centered under the cabinet.
CAUTION: Be careflfl to avoid pinching fingers
between the back of the mounting plate and the wall.
Tighten all bolts. Pull the plate away from the wall to help tighten the bolts.
l Toggle Wings
Bolt End
EN-20
Installation Instructions
USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP
CABINET
You need to drill holes for the top support screws and a hole large enough for the power" cord to fit through.
Read the instructions on the TOP CABINET
TEMPLATE.
Tape it underneath the top cabinet.
NOTE: Adjust top template accordingly if the microwave is bein_ spaced out from the wall due to cabinet depth
(inclucTing cabinet doors) of more than 13".
Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes
in the cabinet bottom.
CHECK BLOWER PLATE
Blower Plate
MOUNT THE MICROWAVE OVEN
F SAFETY, WE RECOMMEND THAT TWO PEOPLE
INSTALL THIS MICROWAVE OVEN.
IMPORTANT: Do not grip or use the handle
or heat shield during installation. Do not remove the cardboard spacers between the
heat shield and door. NOTE: If your cabinet is metal, use the nylon
grommet around the power cord hole to prevent cutting of the cord.
NOTE: We recommend using filler blocks if the
cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are not used, case damage may occur from overtightening
screws.
NOTE: When mounting the
microwave oven, thread power cord through hole in
bottom of top cabinet. Keep it tight throughout Steps
1-3. Do not pinch cord or
lift oven by pulling
[]Lift microwave, tilt
it forward, and hook slots at back bottom
edge onto four lower tabs of mounting plate.
Place the microwave in its upright position, with the top of the unit facing up.
Check to see that the blower plate is correctly
installed on the unit.
EN-21
Rotate front of oven up against cabinet
bottom.
Insert a self-aligning screw through top center cabinet hole. Temporarily secure the oven by
turning the screw at least two full turns after the threads have engaged. (It will be completely
tightened later,) Be sure to keep power cord tight, Be careful not to pinch the cord, especially
when mounting flush to bottom of cabinet,
Cabinet Front
Cabinet Bottom Shelf
FillerBlock
Equivalentto Depth
of CabinetRecess
Self-Aligning Screw
Microwave OvenTop
[_ Attach the microwave oven to the top cabinet.
Installation Instructions
MOUNT THE MICROWAVE
OVEN (cont.)
[] Insert 2 sel{:aligning screws
through outer top cabinet
holes. Turn two full turns on each screw.
/-- -\
//
[] Tighten the outer two screws to the top of the
microwave oven. (While tightening screws, hold the microwave oven in place against the wall and
the top cabinet.)
[] Open the microwave door and remove the two
vent mounting screws located on top of the
microwave using a #1 Phillips screwdriver.
U
/
[] Tip forward. Lift out to remove.
[] Install the charcoal filter. Lay the filter on the back
of the grille with the black mesh face upper.
Tabs Charcoal filter
[] Install grease filters, Seethe Owner's Manual
packed with the microwave.
INSTALLING OR CHANGE
THE CHARCOAL FILTER
(Some Models)
NOTE: The charcoal filter is factory installed in some models. Refer to the Use and Care to see if yours is
factory installed and for replacement information.
Follow these steps to replace or install a charcoal filter.
[] Unplug microwave oven or disconnect power.
f_
Reinstall the vent by sliding the bottom of the vent into place. Push the vent top into position
and slide right into place. Replace the two vent
mounting screws located on top of the microwave using a #1 Phillips screwdriver.
I
Close the microwave door. Plug in microwave oven or reconnect power.
IMPORTANT: Remove the cardhoard spacers between heat shield and door.
EN-22
Loading...
+ 50 hidden pages