Frigidaire Chicago Instruction Manual

Page 1
DO NOT
RETURN THIS PRODUCT
TO THE STORE
NE PAS
RETOURNER CE PRODUIT
AU MAGASIN
Need Assistance? Please contact us!
If you encounter any diculty with this product please email us
service@nuvatek.com
or call us, Monday to Friday 9:00 AM to 5:00 PM EST
1-888-840-9999 or 514-631-7799
Our representatives are ready to help you with any questions.
We can guide you through rst time use and product features.
Just give us a call or send us an email.
Manuals can be downloaded at : www.nuvatek.com
Vous avez besoin d’aide? Contactez nous!
Si vous éprouvez des dicultés avec cet appareil, veuillez nous contacter
service@nuvatek.com
ou par téléphone, lundi au vendredi 9h -17h HNE
1-888-840-9999 ou 514-631-7799
Nos représentants sont à votre disposition pour répondre à toutes les questions.
Nous pouvons vous guider lors de la première utilisation
et vous fournir des explications sur toutes les caractéristiques.
Les manuels peuvent êtres téléchargés à : www.nuvatek.com
Page 2
1 Year Limited Warranty
WARRANTY
ELECTRIC FIREPLACE
LIMITED WARRANTY: This manufacturer’s product warranty extends to the original con-
sumer purchaser of the product. Neither the retailer nor any other company involved in the sale or promotion of this product is a co-warrantor of this manufacturer warranty.
WARRANTY DURATION: All materials and workmanship are warranted to the original consumer purchaser for a period of one (1) year from the original purchase date.
WARRANTY COVERAGE: This product is warranted against defective materials or work­manship when used under normal conditions. This warranty is void if the product has been damaged by accident, in shipment, unreasonable use, misuse, neglect, improper service, commercial use, repairs by unauthorized personnel or other causes not arising out of de­fects in materials or workmanship. There is no warranty with respect to the following, which may be supplied with this product, including without limitation: glass parts, brackets, bulbs, grommet etc. This warranty extends only to the original consumer purchase. This warranty is effective only if the product is purchased and operated in the USA or Canada, and does not extend to any units which have been used in violation of written instructions furnished
by manufacturer or to units which have been altered or modied or to damage to products
or parts thereof which have had the serial number removed, altered, defaced or rendered illegible.
WARRANTY DISCLAIMERS: This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for manufacturer any other liability in connection with the sale of our products. There shall be no claims for defects or failure under any theory of tort, contractor commercial law including, but not limited to, negligence, gross negligence, strict liability, breach of warranty and breach of contract.
WARRANTY PERFORMANCE: During the above one (1) year warranty period, a product with a defect will be either repaired or replaced with a reconditioned comparable model (at manufacturer’s option). The repaired or replacement product will be in warranty for the bal­ance of the one (1) year warranty period and an additional six (6) month period. No charge will be made for such repair or replacement.
SERVICE AND REPAIR: If service is required for an appliance, you should rst contact Nuvatek Distribution customer service at info@nuvatek.com or by calling 1-855-286-
8688.
NOTE: Manufacturer cannot assume responsibility for loss or damage during incoming
shipment. For your protection, carefully package the product for shipment, and insure it with the carrier. Be sure to enclose the following items with your appliance: your full name, return address and daytime phone number; a note describing the problem you experienced; a copy of your sales receipt or other proof of purchase to determine warranty status. C.O.D. shipments
cannot be accepted.
Page 3
1
Chicago - Portable Infrared Electric
Fireplace
Read these instructions carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself & others by observing all safety information. Failure to comply with instructions could result in personal injury and / or property damage. Retain instructions for
future reference.
IMPORTANT INSTRUCTIONS &
Page 4
2
GENERAL SAFETY INFORMATION
When using this fireplace, basic precautions should always be taken to reduce the risk of fire, electric shock and injury to persons, including the following: CAUTION-High temperature, keep electrical cords, drapery and other furnishings at least 3 feet
from the front, side and rear of the fireplace.
1. Read all instructions before using the fireplace, and retain for future reference.
2. Remove the unit from its packaging and check to make sure it is in good condition before using.
3. Do not let children play with parts of the packing (such as plastic bags etc.).
4. Check the household voltage to ensure it matches the fireplace’s rated specification.
5. Check the power cord and plug carefully before use to make sure that they are not damaged.
6. Make certain that the room is equipped with a working smoke detector.
7. Before unplugging the power cord, be sure to turn off the power. When touching the unit, be sure your hands are dry to prevent from electric shock.
8. Do not use the fireplace near curtains, or other inflammable objects. Keep combustible materials, such as pillows, bedding, papers, clothes, and curtains at least 3 feet from the front, side and rear of the fireplace.
9. Do not block air intakes or exhaust, in any manner to prevent possible fire. Do not use on soft or uneven surfaces, like a bed, where openings may get blocked.
10. Extreme caution is necessary when any fireplace in used by, or near children or infants.
11. Never leave children or infants unattended when the fireplace is on or plugged in.
12. Always unplug the fireplace when not in use.
13. Prevent water from getting into the housing of the fireplace during operation or in storage. Always store in a dry area free from potential moisture. This fireplace is not intended for use in bathrooms, laundry areas, or similar indoor locations. Never locate the fireplace where it may fall into a bath tub or get exposed to water in any way.
14. Do not use in places where gasoline, paint, or other inflammable liquids are used or stored.
15. Do not run the cord under carpets. Do not cover the cord with throw rugs, runners, or like products. Arrange the cord away from traffic areas and where it will not be tripped over.
16. Do not operate any fireplace with a damaged cord, damaged plug, after the fireplace malfunctions, or if it has been dropped or damaged in any manner. Return the fireplace to an authorized service facility for examination, electrical or mechanical adjustment, or repair.
17. Do not insert fingers or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock or fire, or damage the fireplace.
18. This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this fireplace.
19. Use this fireplace only as described in this manual. Any other uses not recommended by the manufacture may cause fire, electric shock, or personal injure and may void the warranty privileges.
20. Always plug fireplaces directly into a wall power port. Never use with an extension cord, power strip, surge protector, multiple outlet adapter, cord reel or outlet-type air freshener.
Page 5
3
The use of such devices may create a fire hazard.
21. Faulty wall outlet connections may cause the wall outlet to overheat. Be sure that fireplace plug fits tightly into outlet before each use. During use, check to make certain the fireplace plug is not overheating. If necessary, have a qualified electrician check and / or replace the wall outlet.
22. Do not place the fireplace near a bed, as objects such as pillows or blankets can fall off the bed
and be ignited by the fireplace.
23. Never clean this fireplace while it’s plugged in. To disconnect, turn control to OFF, then remove the plug from the outlet. Never pull the cord. Always hold the plug firmly & remove from the outlet.
24. This fireplace is intended for supplemental heat and / or decorative purposes. Continuous use for several hours can impact the performance & life of the fireplace.
25. It is not intended to be used in commercial, industrial or agricultural settings.
26. Do not use outdoors.
Getting Started
Remove the fireplace from the box.
Remove all the packaging and place it inside the box and either store or dispose of safely.
Package Contents
Electric Fireplace
Remote Control
Instruction Manual
Features
• Simulated Flame Insert, With Adjustable Flame
• 2 Heat Settings: 750W / 1500W
• Energy Efficient
• Consistent Heat from Floor To Ceiling
• Adjustable Electronic Thermostat
• Built-in Timer
• LED Display And Controls For Time And Temp.
• Dual heating Power Level
• Caster Wheels
• Overheating Protection, Auto Safety Shut-off
Quick Reference Guide
Prior to installation, please ensure that your power-outlet is suitable for your fireplace
against both voltage and capacity.
Your fireplace may emit a slight, harmless odor during its first use. This odor is a normal
condition caused by the initial heating of internal fireplace parts and it will not occur again.
It is normal for fireplace to make rattling sound for a short duration of time, during its first
use.
If your fireplace does not emit heat, please ensure the fireplace Switch is on. For further
information, please refer to Troubleshooting section of this manual.
Page 6
Help f u l A d vi c e B e fo r e I n s ta l la t i o n
Function Display
Please retain all packaging until you have checked and counted all the parts and other package contents.
It is recommended to place your fireplace near an existing outlet, for ease of electric connection.
Store your fireplace in a dry, safe and dust-free place while drilling, for fireplace installation.
Do not attempt to wire new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always have a licensed electrician perform maintenance and other repairs.
Oper at in g Instr uc ti on s
Vis u a l ly insp e c t t h e u n i t f o r an y dam a g es bef o r e o p e ra t i on . Do n o t op e r a te the
fire p l a ce i f a n y da m ag e s a r e d et e c te d . C on t a ct y ou r d e a le r i m m ed i at e ly .
) Plug the power cord into a conventional 120V 15 amp outlet and turn the MASTER POWER
1
switch on the rear panel of the portable fireplace. Then push the POWER button on the front control panel or on the remote to turn the unit on. The LED display will show the default value as
0
72
F/220C.
OTE : “ UP ” a n d “ D OW N” a rr o w b u tt o n s o n t h e c o nt r o l p an e l a n d r e mo t e c o nt r o l h a ve
N
d
ual f u n ct i o n c a pa b il i t ie s .
A d j us t TI M E / T EM P w it h u p a rr o w o r a d j us t HI / L O W s et t i n gs .
Ad j u s t T I ME / T E MP w i t h d o wn ar r o w o r a d ju s t 0C/0F se t t i n gs .
4
Page 7
5
Note: If the ambient temperature (the temperature in the area around the fireplace) is greater than the set temperature, the HI/LOW display, fan, and Bulb will not operate.
1) By pusing the
0C/0
F/Down button, you can switch the temperature format from Fahrenheit to
Celsius and vice versa.
2) By pressing the TIME button, the LED display will switch from the “temperature” status to the
“time” status. The default time will display “--“. This means that the TIME is not activated and, therefore, the fireplace will remain on. You must press the HI/LOW/UP button or the
0C/0
F/DOWN once again within (5) seconds to set the time. Each time you press the HI/LOW/UP button, the time will increase by 0.5 Hr. If you press the
0C/0
F/DOWN button, the time will decrease by 0.5
Hr. The maximum value for time is 8.0 Hr. By holding down the HI/LOW/UP button or
0C/0
F/DOWN for (2) seconds, the number rotation will cycle more quickly. If you do not press the
HI/LOW/UP button or
0C/0
F/DOWN within (5) seconds, the time status will switch back to the
temperature status.
Press TIME to switch to time status, then press HI/LOW/UP button once within 5 seconds to scroll up
5 seconds later the value switches to ambient temperature
Press the 0C/0F/Down to switch from Fahrenheit to Celsius.
Page 8
6
3)
Again, the default set temperature displayed on the LED display is 720F. By pressing the TEMP button, the LED display will switch to the temperature status and flash. You must press the HI/LOW/UP button or
0C/0
F/DOWN button once again within (5) seconds to set the desired temperature. Each time you press the HI/LOW/UP button, the temperature setting will increase by 1
0
F. Press the 0C/0F/DOWN button and the temperature will decrease by 10F. The maximum
temperature setting is 86
0
F (300F). If you hold the HI/LOW/UP button or 0C/0F/DOWN button for
(2) seconds, the number rotation will cycle more quickly.
4) Press the HI/LOW/UP button to switch from HI (rated at 1500W) to LOW (rated at 750W). The
default setting is HI.
5) To view the ambient room temperature on the display instead of the set
temperature, push the Time button and while holding, push the Temperature button and then release.
6) Enjoy simulated flame function; turn the Flame knob to adjust brightness.
Press TEMP to switch to temperature status, then press HI/LOW/UP button once within 5 seconds to scroll up
From HI to LOW
Page 9
7
7)
Chicago - Portable Infrared Electric Fireplace can be turned off by pressing the POWER button. DO NOT TURN OFF THE MASTER POWER SWITCH ON THE REAR PANEL OF THE FIREPLACE OR UNPLUG THE FIREPLACE UNTIL THE FAN TURNS OFF. If the fireplace is left on using the TIME function, there will be (5) second sound alert to let you know that the time is expiring. If no actions are taken, the fireplace will shut off.
8) Note that the temperature displayed on the fireplace may not always match the temperature
displayed on wall thermostats, thermometers, or other external temperature read-outs. This is because the fireplace is often located near the floor, which allows for it to register the temperature of the cooler air near and around the floor (warmer air rises up). It does not necessarily mean your room is that cold or that the fireplace is not heating. It is completely normal to have a variance of 2 to 3 degrees between your fireplace’s display and your external temperature read­out mechanism (thermometer, wall thermostat, etc.)
Troubleshooting
1. PROBLEM: a. If the Heat Emitter is broken or damaged b. If the Control Panel is not responding, the temperature reading is above 86
0
F/300C, or there is
a burning odor coming from the portable fireplace
c. Or if the power cord is damaged
SOLUTION: Contact the manufacturer immediately. DO NOT attempt to operate the portable
fireplace as this may cause electric shock, fire, and/or injury.
2. PROBLEM: a. The amount of heated air emitting from the front of the portable fireplace is reduced.
SOLUTION: Check the electrostatic filter to make sure it is free of dust and dirt. Also check the front
grill and rear air intake to make sure it is not being blocked by any kind of debris.
3. PROBLEM: a. The fireplace doesn’t turn on.
SOLUTION: First, test your outlet to make sure it has power. You can do this by plugging in another
appliance and turning the appliance on. Secondly, check the LED display to see if it is on. If this is the case, press the POWER button to turn off the TIME and resume normal operation of the portable fireplace. Third, check the power switch to see if it is lighting up. If the outlet does have power, the LED display would not turn on. If the power switch doesn’t work, contact the manufacturer immediately for further troubleshooting.
4. PROBLEM: a. The fireplace continues to operate even when the power switch is turned off.
SOLUTION: Do not unplug. The fireplace has a fan that will continue to operate even when the
power switch is turned off. This fan continues to run in order to cool down the fireplace. Once the fan stops running, you can then unplug the unit.
5. PROBLEM: a. The control panel doesn’t display TEMPERATURE or TIME.
Page 10
8
SOLUTION: First, check to make sure the power cord is not damaged, is plugged in, and the outlet
has power. Secondly, check to make sure the control panel is not damaged. If the control panel display continues to be inoperable, contact the manufacturer for further troubleshooting.
6. PROBLEM: a. The control panel displays TEMPERATURE and TIME, but the fireplace does not operate.
SOLUTION: The Signal Cable or other relevant plugs may have lost connection. Please contact the
manufacturer for further troubleshooting.
7. PROBLEM: a. The heat emitter is functioning and the air outflow is working, but the temperature displayed on
the LED panel does not increase.
SOLUTION: The temperature sensor may be damaged or may have lost connection. Please contact
the manufacturer immediately for further troubleshooting.
8. PROBLEM:
a. The display shows “Er”. This error code means the heating system is not working correctly. SOLUTION: Contact the manufacturer immediately. DO NOT attempt to operate the fireplace as this
may cause electric shock, fire, and/or injury.
9. PROBLEM:
a. No simulated flame when you turn on the fireplace. SOLUTION: Contact the manufacturer first for instructions on how to replace the bulb. Working life of
G9 halogen bulb is about 1500hours.
Clean & Maintenance
Disconnect from the power supply before attempting any maintenance or cleaning, to reduce the risk of fire, electric shock to persons or damage to property
Warning - Always disconnect from the power supply before cleaning fireplace
For general cleaning use a soft clean duster-never use abrasive cleaners. The glass
viewing screen should be cleaned carefully with a soft cloth. DO NOT use proprietary glass cleaners.
Technical Specification
Supply: 120V, 60Hz
Rated Power: Low Function: 750 watts High Function: 1500 watts
Loading...