Frigidaire AEQB6000ES1, AEQ6000E, AEQ6000ES - AffinityTM 5.8 cu. Ft. Dryer Installation Instructions Manual

Pre-Installation Requirements.................................................................2
Electrical Requirements...........................................................................2
Installation Instructions
Gas & Electric Dryer
Instrucciones para la Inst alación
Secadora a gas y
eléctrica
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA
70, or in Canada, the Canadian electrical code C22.1 part 1. NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1, or
in Canada, CAN/ACG B149.1-2000 NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME USE only. This Dryer is not
recommended for commercial applications such as restaurants or beauty salons, etc.
Exhaust System Requirements....................................................2-3
Gas Supply Requirements........................................................................3
Location of Your Dryer.............................................................................3
Rough-In Dimensions...............................................................................4
Unpacking ..........................................................................................5
Reversing Door Swing.............................................................................6
Electrical Installation........................................................................7
Grounding Requirements................................................................7
Electrical Connections—3-wire...............................................................7
Electrical Connections—4-wire..............................................................8
Gas Connection......................................................................................8
General Installation.................................................................................8
Replacement Parts..................................................................................8
Espanõl..................................................................9-15
Requerimientos eléctricos........................................................................9
Requerimientos del sistema de escape.............................................9-10
Requerimientos del suministro de gas.....................................................10
Ubicación de su secadora.......................................................................10
Dimensiones para la instalación..........................................................11
Instalación en casas móviles.............................................................12
Desembalaje..............................................................................12
Puerta reversible........................................................................13
Instalación eléctrica.......................................................................14
Requerimientos para la puesta a tierra..........................................14
Conexiónes eléctricas - trifilares................................................14
Conexiónes eléctricas - tetrafilares...............................................15
Conexión del gas...........................................................................15
General Instalación............................................................................15
Piezas de recambio.......................................................................15
Antes de comenzar la instalación, lea cuidadosamente estas instrucciones. Esto simplificará la instalación y asegurará que la secadora se instale correctamente y de manera segura. Después de completar la instalación, coloque estas instrucciones cerca de la secadora para referencia futura.
NOTA: La alimentación eléctrica para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Eléctrico Nacional,
ANSI/NFPA 70. NOTA: La alimentación de gas para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Nacional para Gases
Combustibles, ANSI Z223.1. NOTA: La secadora está clasificada para USO DOMESTICO solamente, de acuerdo con la norma ANSI Z 21.5.1 o ANSI/UL 2158 - CAN/CSA C22.2 (las últimas
ediciónes). Esta secadora no se recomienda para uso commercial tal como en restaurantes, salones de belleza, etc.
personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Clear the room, building or area of all occupants.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions.
· If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
para evitar daños materiales, lesiones personales o la muerte.
- No almacene ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de éste o de cualquier otro artefacto eléctrico.
- QUE DEBE HACER SI PERCIBE OLOR A GAS
· No trate de encender ningún artefacto eléctrico.
· No toque ningún interruptor eléctrico; no use ningún teléfono en su edificio.
· Haga salir a todos los ocupantes de la habitación, del edificio y del lugar.
· Llame a su proveedor de gas desde el teléfono de un vecino. Siga las instrucciones del proveedor de gas.
· Si no logra comunicarse con su proveedor de gas, llame al departamento de bomberos.
La instalación y el servicio de mantenimiento debe de realizarlos un instalador calificado, la agencia de servicios o el proveedor de gas.
Printed in U.S.A.
For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage,
Para su seguridad, siga las instrucciones contenidas en este manual a fin de reducir a un mínimo los riesgos de incendio o explosión o
1
P/N 134721800 (0601)
PRE-INSTALLATION REQUIREMENTS
EXHAUST SYSTEM REQUIREMENTS
Tools and Materials Required for Installation:
1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriver.
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.2 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Plastic knife.
ELECTRICAL REQUIREMENTS
ELECTRIC Dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. minimum
time delay fuses or circuit breaker.
POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD KIT - The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp., with 3 open end spade lug connectors with upturned ends or closed loop connectors OR a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp., with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. If being installed in a new branch circuit installation, manufactured (mobile) home, recreational vehicle or area which prohibits grounding through the neutral conductor, the dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp., with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. See ELECTRICAL CONNECTIONS for additional instructions.
CANADA - A 4 wire power cord is installed on dryer.
OUTLET RECEPTACLE - NEMA 10-30R (3-wire) receptacle or NEMA 14-
30R (4-wire) receptacle to be located so the power supply cord is accessible when the dryer is in the installed position.
NEMA 10-30R NEMA 14-30R
GAS Dryer
CIRCUIT - Individual 15 amp. branch circuit fused with a 15 amp.
maximum time delay fuse or circuit breaker.
POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord.
Use separately fused circuits for washers and dryers, and DO NOT operate a washer and a dryer on the same circuit.
NOTE: Do not under any circumstances remove grounding prong from
.
plug
GROUNDING PRONG
Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood and the ground or any other obstruction.
and safe operation of your dryer. Failure to follow these instructions can create excessive drying times and fire hazards.
Excessive lint can build up inside exhaust system and create a fire hazard and restrict air flow. Restricted air flow will increase dryer times. If your present system is made up of plastic duct or metal foil duct, replace it with a rigid or flexible metal duct. Ensure the present duct is free of
any lint prior to installing dryer duct.
lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer exhaust system MUST be exhausted to the outside of the dwelling!
clothing, draperies/curtains, paper) to come in contact with exhaust system. The dryer MUST NOT be exhausted into a chimney, a wall, a
ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.
elbows allowed in the "MAXIMUM LENGTH" charts can cause an accumulation of lint in the exhaust system. Plugging the system could create a fire hazard, as well as increase drying times.
nor use any screws or rivets to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.
gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.
The following are specific requirements for proper
Do not use plastic flexible duct to exhaust the dryer.
If the dryer is not exhausted outdoors, some fine
Do not allow combustible materials (for example:
Exceeding the length of duct pipe or number of
Do not screen the exhaust ends of the vent system,
Explosion hazard. Do not install the dryer where
MAXIMUM LENGTH
of 4” (10.2 cm) Dia. Rigid Metal Duct
VENT HOOD TYPE
Number
of
90°
Turns
0 60 ft. (18.28 m) 48 ft.(14.63 m) 1 52 ft. (15.84 m) 40 ft.(12.19 m) 2 44 ft. (13.41 m) 32 ft. (9.75 m) 3 32 ft. (9.75 m) 24 ft. (7.31 m) 4 28 ft. (8.53 m) 16 ft. (4.87 m)
(Preferred)
4”
(10.2 cm)
Louvered
2½"
(6.35 cm)
MAXIMUM LENGTH
Number
of
90°
Turns
0 30 ft. (9.14 m) 18 ft. (5.49 m) 1 22 ft. (6.71 m) 14 ft. (4.27 m) 2 14 ft. (4.27 m) 10 ft. (3.05 m) 3 NOT RECOMMENDED
of 4” (10.2 cm) Dia. Flexible Metal Duct
(10.2 cm)
VENT HOOD TYPE
(Preferred)
Louvered
4”
(6.35 cm)
2½"
2
CORRECT INCORRECT
7. The dryer MUST be isolated from the gas supply piping system
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).
INSTALL MALE FITTINGS IN CORRECT DIRECTION
In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:
1. Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool down) and start the dryer.
3. Read the measurement on the manometer.
4. The system back pressure MUST NOT be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable.
Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer:
Only the rigid metal duct work should be used.
Venting vertical through a roof may expose the exhaust system
to down drafts causing an increase in vent restriction.
Running the exhaust system through an uninsulatedarea may
cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause an
increase in vent restriction.
The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting. However, on electric dryers, exhausting can be to the right or left side of the cabinet or the bottom of the dryer. On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer. Directional exhausting can be accomplished by installing Exhaust Kit, P/N 131456800, available through your parts distributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
LOCATION OF YOUR DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT
Alcove 0 (0 cm) 0 (0 cm) 0 (0 cm) Closet 0 (0 cm) 0 (0 cm) 0 (0 cm) 1 (2.54 cm) Closet door ventilation required: 2 louvered openings each 60 square inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and top of door.
This dryer MUST be exhausted outdoors.
5. The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation.
0" (0 cm)
0" (0 cm)1" (2.54 cm)
0" (0 cm)
SAME AS OTHER SIDESAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDESAME AS OTHER SIDE
5 7/8"5 7/8"
5 7/8"
5 7/8"5 7/8"
4 3/8"4 3/8"
4 3/8"
4 3/8"4 3/8"
3 3/4"3 3/4"
3 3/4"
3 3/4"3 3/4"
(9.5 cm)(9.5 cm)
(9.5 cm)
(9.5 cm)(9.5 cm)
3 3/4"3 3/4"
3 3/4"
3 3/4"3 3/4"
13 1/2"13 1/2"
13 1/2"
13 1/2"13 1/2"
GAS SUPPLY REQUIREMENTS
plastic-coated. Stainless steel or plastic-coated brass MUST be used.
1. Installation MUST conform with local codes, or in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition).
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect your
dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass.
4. The gas supply line MUST have an individual shutoff valve.
5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test
gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.
6. The dryer MUST be disconnected from the gas supply piping
system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).
Replace copper connecting pipe that is not
60 sq. inches (387.1 sq. cm)
60 sq. inches (387.1 sq. cm)
CLOSET DOOR
3
Dryer Installation Dimensions
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789
1
9
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
Free-Standing & Under Counter
23¾”
(60.33)
inches (cm)
2
5/8"
(6.67)
24”
(60.96)
22
¾”
(57.79)
24
3/8
(61.91)
27”
(68.58)
5.875"(14.93) To base exhaust
4.375"(11.12) T o side exhausts
15/8" (4.13)
5.0"(12.7) Center line height for rear, right, left vent
5¼”
(13.97)
29¾”
(75.57)
(12.70)
(34.29)
To rear and base exhausts
5”
Stacked Dryer Installation Dimensions
23
23
23
23
23
23
23
23
23
23
23
23
23
To front of cabinet
28.25"(71.76) To clear kobs
28.75"(73.03) To clear door
29.5"(74.93) To clear open door
53"(134.62)
inches (cm)
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678
23
23
23
23
23
23
23
23
23
4.375"
23
23
23
(11.12)
23
23
Side
23
23
23
exhausts
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
41.00"
23
23
(97.16)
23
23
23
Center line
23
23
23
height for
23
23
23
rear, right,
23
23
left vents
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
4
72.00"
(172.88)
Gas supply pipe on rear of unit
2.375" (6.03)
38.25"
(97.16)
Electrical supply on rear of unit
13½”
Gas supply pipe on rear of unit
27”
(68.58)
27" (68.58)
13.5"
(34.29)
2”
3/8
(6.03)
34”
(86.36)
2.25”
(5.72)
Electrical supply on rear of unit
35”
(88.90)
MOBILE HOME INSTALLATION
UNPUNP
UNP
UNPUNP
ACKINGACKING
ACKING
ACKINGACKING
1. Dryer MUST be exhausted outside (outdoors, not beneath
the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred.
2. If dryer is exhausted through the floor and area beneath
the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.
3. When installing a gas dryer into a mobile home, a provision must be made for outside make up air. This provision is to be not less than twice the area of the dryer exhaust outlet.
4. This dryer MUST be fastened to the floor. Mobile Home Installation Kit No. 346764 is available from your dealer.
5. Refer to pages 2 and 3 for other important venting requirements.
6. Installation MUST conform to current Manufactured Home Construction & Safety Standard (which is a Federal Regulation Title 24 CFR-Part 32-80) or when such standard is not applicable, with American National Standard for Mobile Homes.
1. Using a rug, blanket or a piece of cardboard packing to protect the floor, carefully lay the dryer on its left side and remove the foam shipping base.
2. Return the dryer to an upright position.
FOAM SHIPPING
PAD
PACKING
The dryer is designed under ANSI Z 21.5.1 or
ANSI/UL2158 - CAN/CSA C22.2 (latest editions) for HOME USE only.
5
Be sure to wear gloves while reversing the door assembly .
DRYER DOOR REVERSAL INSTRUCTIONS
1. Open the dryer door.
2. Remove the five screws, 1 thru 5 and the two screws, 6 and 7, that attach the inner door assembly to the outer door
assembly. Lift the outer door assembly out of the inner
door assembly and place on a soft flat surface.
5. Remove the hinge cutout plug. Rotate it and install it in the opposite side of the outer door.
1
7
5
2
6
3
4
3. Remove the two (2) hinge attachment screws and place the inner door assembly on a soft flat surface.
6. Remove the two screws that secure the hinge to the front panel.
4. Remove the screws that attach the strike plate. Rotate the strike plate and reattach it to the opposite side of the inner
door.
7. Remove the catch plate from the front panel.
8. Rotate and reinstall the hinge and the catch plate in the sides opposite of where they were removed.
9. Reattach the door assemblies in reverse order.
10. Close the door.
6
ELECTRICAL INSTALLATION
ELECTRIC Dryer
The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/or a fire hazard.
This appliance MUST be properly grounded. Electrical shock can result if the dryer is not properly grounded. Follow the instructions in this manual for proper grounding.
Do not use an extension cord with this dryer. Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt, creating electrical shock and/or fire hazard. Locate the dryer within reach of the receptacle for the length power cord to be purchased, allowing some slack in the cord. Refer to the pre-installation requirements in this manual for the proper power cord to be purchased.
A U.L. approved strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.
Do not use an aluminum wired receptacle with a copper wired power cord and plug (or vice versa). A chemical reaction occurs between copper and aluminum and can cause electrical shorts. The proper wiring and receptacle is a copper wired power
cord with a copper wired receptacle. NOTE: Dryers operating on 208 volt power supply will have longer
drying times than operating on 240 volt power supply.
GROUNDING REQUIREMENTS
NON-CANADIAN ELECTRIC Dryer
Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1. The dryer MUST be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.
2. If your dryer is equipped with a power supply cord having an
equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. Do not
modify plug provided with the appliance.
For a permanently connected dryer:
1. The dryer MUST be connected to a grounded metal, permanent
wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment­grounding terminal or lead on the appliance.
ALL GAS Dryers
This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
ELECTRICAL CONNECTIONSFOR 3-WIRE SYSTEM
NON-CANADIAN ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.
2. Install a U.L. approved strain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time.
3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief.
4. Attach the power cord neutral (center wire) conductor to the silver colored center terminal on the terminal block. Tighten the screw securely.
5. Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block. Tighten both screws securely.
at connections.
6. Reattach the strain relief mounting bracket to the back of the dryer with two screws. Tighten screws securely.
GREEN GROUND SCREW
NEUTRAL GROUND WIRE
Do not make a sharp bend or crimp wiring/ conductor
SILVER TERMINAL
NUT
TIGHTEN NUT TO THESE THREADS
Canadian ELECTRIC Dryer
DANGER
conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1. The dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.
2. Since your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. Do not modify plug provided
with the appliance.
Improper connection of the equipment grounding
STRAIN RELIEF MOUNTING BRACKET
7. Tighten the screws securing the cord restraint firmly against the power cord.
8. Tighten the strain relief nut securely so the strain relief does not turn.
9. Reinstall the terminal block cover.
POWER CORD
7
ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM
NON-CANADIAN ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.
2. Install a U.L. approved strain relief in the entry hole of the mounting bracket. Finger tighten the nut only at this time.
VALVE OPEN / GAS FLOW POSITION
4. Test all connections by brushing on a soapy water solution. NEVER test for gas leaks with an open flame.
3. Remove the ground wire from the green ground screw located above the terminal block.
GREEN GROUND SCREW
NEUTRAL GROUND WIRE
RED
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or SRDT through the strain relief.
TYPICAL 4 CONDUCTOR
30 AMP NEMA 14-30 TYPE SRDT OR ST
5. Attach the green power cord ground wire to the cabinet with the green ground screw.
6. Attach the white (neutral) power cord conductor from the power cord and the neutral ground wire from the dryer harness to the silver-colored center terminal on the terminal block. Tighten the screw securely.
7. Attach the red and black power cord conductors to the outer brass-colored terminals on the terminal block.
at the connections.
8. Tighten the screws securing the cord restraint firmly against the power cord.
9. Tighten the strain relief nut securely so the strain relief does not turn.
10. Reinstall the terminal block access cover.
GREEN POWER CORD GROUND WIRE
MOUNTING
BRACKET
POWER CORD
Do not make a sharp bend or crimp wiring/conductor
SILVER TERMINAL
WHITE
STRAIN
RELIEF
TYPICAL 4 CONDUCTOR
TERMINAL BLOCK
BLACK
NUT
TIGHTEN NUT TO THESE THREADS
BLACK
WHITE
RED
GREEN
GAS CONNECTION
1. Remove the shipping cap from gas pipe at the rear of the dryer. NOTE: DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer (see pages 6 and 7). Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for a connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections.
GENERAL INSTALLATION
1. Connect the exhaust duct to outside exhaust system (see pages 3 and 4). Use duct tape to seal all joints.
2. With the dryer in its final position, adjust one or more of the legs until the dryer is resting solid on all four legs. Place a level on top of the dryer. The dryer MUST be level and resting solid on all
four legs.
3. Plug the power cord into a grounded outlet. NOTE: Check to ensure the power is off at circuit breaker/fuse box before plugging the power cord into the outlet.
4. Turn on the power at the circuit breaker/fuse box.
Before operating the dryer, make sure the dryer area is clear and free from combustible materials, gasoline, and other flammable vapors. Also see that nothing (such as boxes, clothing, etc.) obstructs the flow of combustion and ventilation air.
5. Run the dryer through a cycle check for proper operation.
NOTE: On gas dryers, before the burner will light, it is necessary for the gas line to be bled of air. If the burner does not light within 45 seconds the first time the dryer is turned on, the safety switch will shut the burner off. If this happens, turn the timer to "OFF" and wait 5 minutes before making another attempt to light.
6. If your dryer does not operate, please review the "Avoid Service Checklist" located in your Use and Care Guide before calling for service.
7. Place these instructions in a location near the dryer for future reference. NOTE: A wiring diagram/tech sheet is in an envelope attached to the inside side panel of the dryer by the blower housing.
Pedestal
A pedestal accessory, Model No. APWD15W, specifically designed for this dryer may be used when elevating the dryer for ease of use. Failure to use accessories certified by the manufacturer could result in personal injury, property damage or damage to the dryer.
REPLACEMENT PARTS
If replacements parts are needed for your dryer, contact the source where you purchased your dryer, call 1-800-944-9044, or visit our website, www.frigidaire.com, for the Frigidaire Company Authorized Parts Distributor nearest you.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a garbage container or make materials inaccessible to children.
The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and maintaining any appliance.
3. Open the shutoff valve in the gassupply line to allow gas to flow through the pipe.
8
REQUERIMIENTOS DE INSTALACIÓN PRELIMINARES
Herramientas y materiales necesarios para la instalación:
1. Destornillador Phillips
2. Alicates universales
3. Nivel de carpintero
4. Destornillador para tornillo de cabeza plana o recta
5. Cinta para ductos
6. Ducto metálico rígido o flexible de 4"(10,2 cm)
7. Caperuza de salida
8. Sellador de tuberías (gas)
9. Un cuchillo de plástico
REQUERIMIENTOS ELÉCTRICOS
Secadoras ELÉCTRICAS
CIRCUITO - Circuito derivado individual de 30 amperios, con fusibles de 30
amp. del tipo de retardo mínimo o disyuntores.
ALIMENTACIÓN ELÉCTRICA - Corriente alterna, monofásica, 60 Hz, 240 voltios; trifilar o tetrafilar.
CORDÓN ELÉCTRICO - En la secadora se DEBE usar un cordón eléctrico trifilar NEMA 10-30 tipo SRDT para un voltaje nominal mínimo de 240 voltios CA, 30 amp., con 3 conectores de horquillas con terminales abiertos y extremos dirigidos hacia arriba o conectores de anillo cerrado y marcados para uso en secadoras de ropa tipo SRDT o ST (como sea necesario) para un voltaje nominal mínimo de 240 voltios CA, 30 amp. con 4 conectores de horquillas con terminales abiertos y extremos dirigidos hacia arriba o conectores de anillo cerrado. Si siendo instalado en una nueva instalación del circuito del rama, un vehículo casero, recreacional (móvil) manufacturado o un área que prohíben el poner a tierra a través del conductor neutral, se DEBE utilizar un cordón eléctrico tetrafilar NEMA 14-30 tipo SRDT o ST (como sea necesario) para un voltaje nominal mínimo de 240 voltios CA, 30 amp. con 4 conectores de horquillas con terminales abiertos y extremos dirigidos hacia arriba o conectores de anillo cerrado y marcados para uso en secadoras de ropa. Ver CONEXIÓNES ELÉCTRICAS para adicional información. (Canadá - un cordón de suministro de energía de 4 alambres es instalado en la secadora.) TOMACORRIENTE - El tomacorriente NEMA 10-30R (3 alambres) o NEMA 14-30R (4 alambres) debe estar ubicado de manera que el cordón eléctrico llegue hasta él cuando la secadora esté instalada.
o un cordón eléctrico tetrafilar NEMA 14-30
NEMA 10-30R NEMA 14-30R
Secadoras a GAS
CIRCUITO - Circuito individual derivado de 15 amp, con fusibles de 15 amp.
de retardo máximo o disyuntor. Utilice circuitos de fusibles separados para la lavadora y la secadora, No opere una lavadora y una secadora en el mismo circuito. ALIMENTACIÓN ELÉCTRICA - Corriente alterna, monofásica, 60 Hz, 120 voltios, trifilar. CORDÓN ELÉCTRICO - La secadora está equipada con un cordón eléctrico trifilar para 120 voltios.
NOTA: No saque por
ESPIGA
REQUERIMIENTOS DEL SISTEMA DE ESCAPE
Utilice solamente ductos metálicos, rígidos o flexibles de 4" (10,2 cm) de diámetro (mínimo) y una caperuza de salida de uso aprobado, con registros que giren hacia afuera que se abren cuando la secadora se encuentra en funcionamiento. Cuando la secadora se detiene, los registros se cierran automáticamente para evitar las corrientes de aire y la entrada de insectos y roedores. Para evitar obstruir la salida, mantenga una altura libre mínima de 12"(30,5 cm) entre la caperuza de salida y el piso o entre cualquier otra obstrucción.
el funcionamiento correcto y seguro de su secadora. El incumplimiento de estas instrucciones puede causar prolongación excesiva del tiempo de secado y riesgos de incendio.
No use ductos flexibles de plástico para el escape de la secadora.
Se puede acumular un exceso de pelusas en el sistema de escape, crear un riesgo y obstruir el flujo de aire. La restricción del flujo del aire prolongará el tiempo de secado. Si su sistema de escape actual tiene ductos de plástico o de láminas metálicas delgadas, reemplácelo con un ducto metálico rígido o flexible. Asegúrese de que los ductos existentes no tengan pelusas
antes de instalar el ducto de la secadora.
Si el escape de la secadora no se dirige al exterior, algunas pelusas
finas serán sopladas hacia el recinto donde se efectúa el lavado. La
acumulación de pelusas en cualquier lugar de la casa, puede crear un peligro para la salud y un riesgo de incendio. ¡El sistema de escape de la
secadora DEBE estar dirigido hacia el exterior de la vivienda!
No permita que los materiales combustibles (por ejemplo: la
ropa, cortinas/cortinajes, papel) tengan contacto con los ductos. El
escape de la secadora NO DEBE dirigirse hacia el interior de una chimenea, hacia una pared, hacia el cielo raso o hacia cualquier otro espacio reducido del edificio, donde puede ocurrir acumulación de pelusas y constituir un peligro de incendio.
Exceder la longitud del conducto rigido o los números de codos
permitidos en los diagramas "LARGO MÁXIMO" puede disminuir la
capacidad de exhaustación del sistema. Obstruir el conducto puede provocar peligro de incendio, así como aumentar el tiempo de secado.
No coloque un filtro en el extremo del escape del sistema ni
emplee tornillos o remaches para ensamblar el sistema de escape.
Las pelusas podrían quedar atrapadas en los filtros, en los tornillos o en los remaches, lo cual obstruiría el sistema de escape y crearía un riesgo de incendio, así como también prolongaría el tiempo de secado. Use una caperuza de salida adecuada para el extremo del ducto que salga al exterior de la vivienda y selle todas las juntas con cinta adhesiva para ductos. Todos los accesorios de tubería machos, DEBEN ser instalados aguas abajo del flujo de aire.
guarda gasolina u otros materiales inflamables. Si la secadora se instala en un garage, ella debe estar por lo menos 18 pulgadas (45,7 cm) por encima del suelo. El incumplimiento puede resultar en la muerte, explosión, incendio, o quemaduras.
Los siguientes requerimientos son específicos para
Riesgo de explosión. No instale la secadora donde se
LARGO MÁXIMO del Conducto Metálico Rigido
de 4” (10,2 cm) de Diámetro
TIPO DE CAPERUZA DE SALIDA
(Preferido)
Número
de Codos
a 90°
4”
(10,2 cm)
0 60 pies (18,28 m) 48 pies(14,63 m) 1 52 pies (15,84 m) 40 pies(12,19 m) 2 44 pies (13,41 m) 32 pies (9,75 m) 3 32 pies (9,75 m) 24 pies (7,31 m) 4 28 pies (8,53 m) 16 pies (4,87 m)
Apersianada
2½"
(6.35 cm)
LARGO MÁXIMO del Conducto Metálico Flexible
de 4” (10,2 cm) de Diámetro
TIPO DE CAPERUZA DE SALIDA
(Preferido)
Apersianada
Número
de Codos
a 90°
0 30 pies (9,14 m) 18 pies (5,49 m) 1 22 pies (6,71 m) 14 pies (4,27 m) 2 14 pies (4,27 m) 10 pies (3,05 m) 3 NO RECOMENDADO
9
4”
(10,2 cm)
2½"
(6.35 cm)
Impreso en los EE.UU.
CORRECTO
INCORRECTO
INSTALE LOS ACCESORIOS MACHOS EN LA DIRECCIÓN CORRECTA
Para las instalaciónes cuyas sistema de exhaustación no se encuentre en el diagrama, se puede utilizar el metodo a continuación para determinar si el sistema de exhaustación es apropiado.
1. Conecte un manómetro a tubo inclinado o digital entre la secadora y el unión de exhaustación de la secadora.
2. Ponga el contador de tiempo de la secadora y la temperatura a aire frío (enfiriamiento), y la secadora en la posición de marcha.
3. Lea la medida indicada en el manómetro.
4. La baja presión NO DEBE exceder 0.75 pulgada de la columna de agua. Si la baja presión es inferior a 0.75" de la columna de agua, el sistema es aceptable. Si la lectura indica una presión superior a 0.75" de la columna de agua, la capacidad del circuito es insuficiente y la instalación es inaceptable.
Aungue un sistema vertical sea aceptable, algunas circunstancias atenuantes pueden afectar el funcionamiento de la secadora:
Se debe utilizar solamente conductos metalicos rigidos.
Una salida del sistema vertical en el techo, puede exponerle a un corriente de aire descendente y disminuir así su capacidad de exhaustación.
El aislante que debe atravesar el sistema puede causar condensación y disminuir así la capacidad de exhaustación del sistema.
La capacidad de exhaustación de un sistema de exhaustación comprimido o ondulado puede disminuirse.
El sistema de exhaustación debe de ser inspeccionado y limpiado por lo menos cada 18 meses de uso normal. Cuanto más la secadora está utilizada, más debe verificar el buen funcionamiento del sistema de exhaustación y de la tapa del orificio de ventilación.
UBICACIÓN DEL ESCAPE
Todas las secadoras vienen de fábrica equipadas con escape trasero. Sin embargo, en las secadoras eléctricas, el escape puede hacerse al lado derecho o izquierdo del gabinete o en la parte inferior de la secadora. En las secadoras a gas, el escape del aire puede estar en el lado derecho del gabinete o en la parte inferior de la secadora. El escape direccional puede efectuarse instalando un Juego de Escape, P/N 131456800, disponible a través de su distribuidor de repuestos. Siga las instrucciones que se suministran con el juego.
DIMENSIONES PARA LA UBICACIÓN DEL DUCTO DE ESCAPE
5. Una toma de 1/8 de pulgada (0,32 cm) N.P.T. accesible para conexión del
manómetro de prueba, DEBE ser instalada inmediatamente aguas arriba de la conexión de la tubería de alimentación de gas a la secadora.
6. La secadora DEBE ser desconectada del sistema de tuberías de
alimentación de gas durante cualquier ensayo de presión del sistema de tuberías de alimentación de gas realizado a presiones de prueba de más de 1/2 lbs/pulg.
2
(3,45 kPa).
7. La secadora DEBE aislarse del sistema de tuberías de alimentación de
gas durante cualquier ensayo de presión del sistema de tuberías de alimentación de gas realizado en ensayos de presión iguales o inferiores a 1/2 lbs/pulg.2 (3,45 kPa).
UBICACIÓN DE SU SECADORA
NO INSTALE SU SECADORA:
1. En un lugar donde puede haber goteos de agua o quede expuesta a las inclemencias del tiempo.
2. En un área donde pueda entrar en contacto con cortinas, cortinajes o cualquier otra cosa que obstruya el flujo de combustión y ventilación de aire.
3. Sobre alfombras. El piso DEBE ser firme con un desnivel máximo de 1 pulgada (2,54 cm).
INSTALACIÓN DENTRO DE UN NICHO O ARMARIO
1. Si la secadora es instalada en un dormitorio, cuarto de baño, nicho o armario, el tubo del escape DEBE ser instalado hacia el exterior.
2. No se debe instalar ningún otro artefacto que queme combustible en el mismo armario en que está instalada la secadora a Gas.
3. La secadora necesita espacio a su alrededor para una ventilación adecuada.
NO instale la secadora en un armario con puerta maciza.
4. Se requiere como mínimo una abertura de 120 pulgadas cuadradas (774,2 cm2), dividida equitativamente para la parte superior e inferior de la puerta. Cuando se instala una puerta, es necesario proveer aberturas para el aire. Una puerta apersianada con aberturas para el aire en todo el largo de la puerta es aceptable.
DESPEJES MÍNIMOS DE INSTALACIÓN - Pulgadas (cm)
Parte Parte Parte
Lados Trasera Superior Delantera
Alcoba 0 (0 cm) 0 (0 cm) 0 (0 cm) Armario 0 (0 cm) 0 (0 cm) 0 (0 cm) 1 (2,54 cm)
Ventilación requirida en la puerta del armario: dos aberturas rejilladas cada 60 pulg.2 (387 cm2) — 3" (7,6 cm) desde la parte inferior y superior de la puetra.
El tubo del escape de la secadora debe ser instalado hacia el exterior.
5. Las siguientes ilustraciónes muestran las dimensiónes mínimas de espacio libre que debe existir para el buen funcionamiento de la secadora cuando se instala en un nicho o en un armario.
0" (0 cm)
0" (0 cm)1" (2.54 cm)
IGUAL QUE EL OTRO LADOIGUAL QUE EL OTRO LADO
IGUAL QUE EL OTRO LADO
IGUAL QUE EL OTRO LADOIGUAL QUE EL OTRO LADO
5 7/8"5 7/8"
5 7/8"
5 7/8"5 7/8"
(15 cm)(15 cm)
(15 cm)
(15 cm)(15 cm)
13 1/2"13 1/2"
13 1/2"
13 1/2"13 1/2" (34 cm)(34 cm)
(34 cm)
(34 cm)(34 cm)
3 3/4"3 3/4"
3 3/4"
3 3/4"3 3/4"
(9,5 cm)(9,5 cm)
(9,5 cm)
(9,5 cm)(9,5 cm)
REQUERIMIENTOS DEL SUMINISTRO DE GAS
Reemplace la tubería de conexión de cobre que no está recubrida con plástico. El latón inoxidable o recubrido con plástico DEBE SER utilizado.
1. La instalación DEBE hacerse cumplir con los códigos locales o en ausencia
de los mismos, de acuerdo con los estandares del National Fuel Gas Code (Código Nacional para Gases Combustibles), ANSI Z223.1 (la última editión).
2. La tubería de alimentación de gas debe ser de 1/2 pulgada (1,27 cm) de
diámetro.
3. Si está permitido por los códigos locales, se puede usar tubería de metal
para conectar su secadora a la línea de suministro de gas. La tubería DEBE ser fabricada de acero inoxidable o cobre recubierto de plástico.
4. La tubería de alimentación de gas DEBE tener una llave de cierre
individual.
4 3/8"4 3/8"
4 3/8"
4 3/8"4 3/8"
(11 cm)(11 cm)
(11 cm)
(11 cm)(11 cm)
3 3/4"3 3/4"
3 3/4"
3 3/4"3 3/4"
(9,5 cm)(9,5 cm)
(9,5 cm)
(9,5 cm)(9,5 cm)
10
0" (0 cm)
PUERPUER
TT
A DEL ARMARIOA DEL ARMARIO
PUER
T
A DEL ARMARIO
PUERPUER
TT
A DEL ARMARIOA DEL ARMARIO
60 Pulg.²60 Pulg.²
60 Pulg.²
60 Pulg.²60 Pulg.² (387,1 cm(387,1 cm
(387,1 cm
(387,1 cm(387,1 cm
60 Pulg.²60 Pulg.²
60 Pulg.²
60 Pulg.²60 Pulg.² (387,1 cm(387,1 cm
(387,1 cm
(387,1 cm(387,1 cm
22
2
22
))
)
))
22
2
22
))
)
))
9
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5
3
3
3
3
3
3
23¾”
(60.33)
inches (cm)
2
5/8"
(6.67)
Dimensiones De la Instalación
24”
(60.96)
234567890123456789012345678901223234
2342
22
¾”
(57.79)
24
3/8
(61.91)
27”
(68.58)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5.875"(14.93)
2
2
2
Para basar los
2
2
extractores
2
2
2
2
2
4.375"(11.12)
2
2
2
Para echar a
2
2
un lado
2
2
extractores
2
2
5.0"(12.7)
2
2
Línea altura
2
2
de centro para el respiradero posterior, derecho, izquierdo
15/8" (4.13)
5¼”
(13.97)
29¾”
(75.57)
(12.70)
Fuente eléctrica en la parte
posterior de la unidad
13½”
(34.29)
A los
extractores
de la parte
posterior y
de la base
5”
Pipe de la fuente de gas en la parte posterior de
la unidad
27”
(68.58)
2”
3/8
(6.03)
34”
(86.36)
2.25”
(5.72)
35”
(88.90)
Dimensiones Apiladas De la Instalación Del Secadora
Al frente del gabinete
28.25"(71.76) A las perillas claras
28.75"(73.03) A las perillas puerta
29.5"(74.93) En ei claro abra la puerta
53"(134.62)
inches (cm)
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4.375"
2
2
2
(11.12)
2
2
2
Para echar
2
2
2
a un lado
2
2
extractores
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
41.00"
2
2
(97.16)
2
2
2
Línea
2
2
2
altura de
2
2
2
centro para el
2
2
2
respiradero
2
2
2
posterior,
2
2
derecho,
2
2
2
izquierdo
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
11
72.00"
(172.88)
Pipe de la
fuente de gas
en la parte
posterior de
la unidad
2.375" (6.03)
38.25"
(97.16)
13.5"
(34.29)
27" (68.58)
Fuente
eléctrica
en la
parte
posterior
de la
unidad
INSTALACIÓN EN CASAS MÓVILES
1. El tubo de escape de la secadora DEBE ser instalado hacia el
exterior (El escape debe colocarse en la parte exterior y no debajo de la casa móvil.) Debe usarse ducto de metal que no sea combustible. El ducto de metal debe tener cuatro pulgadas (10,16 cm) de diámetro y no tener obstrucciones. Es preferible usar ducto de metal que sea rígido.
2. Si el tubo de escape de la secadora corre a través del piso y el área debajo de la casa móvil es cerrada, el ducto de escape DEBE terminar fuera del recinto, con el extremo final asegurado en contra de la estructura de la casa móvil.
3. Al instalar una secadora de gas en una casa móvil, hay que instalar una provisión de aire fresco suplementario. La provisión tiene que ser más grande que dos veces el espacio del escape de la secadora.
4. Esta secadora DEBE asegurarse al piso. El juego para instalación en la casa móvil es el No. 346764 y lo puede adquirir con su distribuidor.
5. Vea las páginas 2 y 3 para otros requísitos importantes de ventilación.
6. La instalación DEBE cumplir con las estándares aplicables de la Manufactured Home Construction & Safety Standard ­Estándares de Seguridad y Construcción de Casas Prefabricadas (Título 24 CFR - Parte 32-80 del Reglamento Federal) o cuando dichos estándares no sean aplicables, se deben complir con los estándares de la American National Standard for Mobile Homes (Estándares Nacionales Americanas para Viviendas Móviles).
MODELOS AUTÓNOMOS CON CONSOLA
SUPERIOR
DIMENSIONES PARA LA INSTALACIÓN
DESEMBALAJE
1. Utilizando las cuatro esquineras de embarque de la caja de cartón (dos a cada lado), coloque cuidadosamente la secadora sobre el costado izquierdo y saque la base de espuma de embarque.
Para evitar daños, no use el panel de control como
un medio para levantar o mover la secadora.
2. Vuelva la secadora a su posición vertical.
PLACA DE ESPUMA DE EMBARQUE
Esta secadora ha sido diseñada PARA USO
DOMESTICO solamente, de acuerdo con la norma ANSI Z 21.5.1 o
ANSI/UL 2158-CAN/CSA C22.2 (las últimas ediciónes).
CORRECTO
EMPAQUE
NO
INCORRECTO
12
INSTRUCCIONES DE LA REVOCACIÓN DE LA PUERTA DE LA SECADORA
Use guantes para dar vuelta la puerta.
1. Abra la puerta de la secadora.
2. Retire los cinco tornillos, 1 a 5, y los dos tornillos, 6 y 7, que fijan la parte interior de la puerta a la parte exterior. Levante la parte exterior y retírela de la parte interior y colóquela sobre una superficie plana y lisa.
5. Retire la bisagra. Gírela e instálela en el lado opuesto de la parte exterior.
1
7
5
2
6
3
4
3. Retire los dos (2) tornillos de fijación de las bisagras y coloque
la puerta interior sobre una superficie plana y lisa.
6. Retire los dos tornillos que fijan la bisagra al panel frontal.
4. Retire los tornillos que fijan la placa contra golpes. Gire la placa contra golpes y vuelva a colocarla en el lado opuesto de la puerta interior.
7. Retire la placa de sujeción del panel frontal.
8. Gire y vuelva a instalar la bisagra y la placa de sujeción en los lados opuestos a los lados de donde las sacó.
9. Vuelva a fijar la puerta en orden inverso.
10. Cierre la puerta.
13
INSTALACIÓN ELÉCTRICA
Secadoras ELÉCTRICAS
Los siguientes requerimientos son específicos para el funcionamiento correcto y seguro de su secadora. El incumplimiento de estas instrucciones puede causar prolongación
excesiva del tiempo de secado y riesgos de incendio.
Este artefacto DEBE ser puesto a tierra de
manera correcta. Si la secadora no está debidamente puesta a tierra se
puede producir un choque eléctrico. Siga las instrucciones indicadas en este manual para la puesta a tierra en forma correcta.
No use un cordón de extensión con esta
secadora. Algunos cordones de extensión no pueden soportar la cantidad
de corriente eléctrica que utiliza esta secadora y pueden fundirse, creando un peligro de choque eléctrico y/o incendio. Ubique la secadora de manera que el cordón eléctrico llegue hasta el tomacorriente que se va a usar, dejando un poco de holgura para el cordón. Consulte los requerimientos de instalación preliminares indicados en este manual para el cordón eléctrico que debe ser adquirido.
Se debe instalar un anclaje aprobado por el U.L.
para el cordón eléctrico. Si no se utiliza un anclaje para sujetar el cordón
eléctrico, éste puede salirse de la secadora y cortarse con cualquier movimiento, resultando en un choque eléctrico.
No utilice un tomacorriente con cables de
aluminio con un cordón y un enchufe de cobre (o viceversa). Se
produce una reacción química entre el cobre y el aluminio que puede causar cortacircuitos. El cableado y tomacorriente apropiado es un
cordón eléctrico equipado con conductores de cobre con un tomacorriente con conductores de cobre. NOTA: Las secadoras que operan con un suministro de energía de 208
voltios usarán más tiempo de secado que aquellas que operan con un suministro de energía de 240 voltios.
REQUERIMIENTOS PARA LA PUESTA A TIERRA
TORNILLO VERDE DE PUESTA A TIERRA
CABLE DE PUESTA A TIERRA NEUTRAL
BORNE PLATEADO
TUERCA
ATORNILLE LA TUERCA EN ESTAS ROSCAS
SOPORTE DE MONTAJE DEL ANCLAJE DE CABLE
CORDÓN ELÉCTRICO
CONEXIÓNES ELÉCTRICAS PARA
UN SISTEMA TRIFILAR
Secadoras ELÉCTRICAS
La conexión indebida del conductor de puesta a tierra del equipo puede ocasionar un riesgo de choque eléctrico. Consulte con un electricista profesional si tiene alguna duda respecto a la puesta a tierra correcta del artefacto.
Para una secadora puesta a tierra, con cordón eléctrico:
1. La secadora DEBE ser puesta a tierra. En caso de malfuncionamiento o
falla, la puesta a tierra reducirá el riesgo de choque eléctrico proporcionando un trayecto de menor resistencia a la corriente eléctrica.
2. Si su secadora está equipada con un cordón eléctrico que posee un
conductor de puesta a tierra del equipo y un enchufe de puesta a tierra, dicho enchufe DEBE ser conectado a un tomacorriente adecuado, debidamente instalado y puesto a tierra de acuerdo con todos los códigos y reglamentos locales. Si tiene alguna duda consulte a un electricista profesional. No modifique el enchufe proporcionado la
aplicación.
Para una secadora conectada permanentemente:
1. La secadora DEBE ser conectada a un sistema de cableado metálico
permanente, puesto a tierra; o se debe instalar un conductor de puesta a tierra de equipo junto con los conductores del circuito y conectarse al borne de puesta a tierra del equipo o al cable del artefacto.
TODAS las secadoras a GAS
Esta secadora está equipada con un enchufe de tres espigas (de puesta a tierra) para protección en contra de choques eléctricos y debe ser conectada directamenta en un receptáculo para tres espigas el cual debe estar puesto a tierra. No corte ni elimine la espiga de puesta a tierra de este enchufe.
Secadoras ELÉCTRICAS
1. Saque los tornillos que sujetan la cubierta de acceso del tablero de bornes y el soporte de montaje del anclaje del cordón, situado en la esquina superior de la parte trasera de la secadora.
2. Instale un anclaje de cable aprobado por el U.L., en el orificio de entrada del cordón eléctrico en el soporte de montaje. Luego apriete la tuerca con los dedos solamente.
3. Inserte un cordón eléctrico de 30 amp, NEMA 10-30 Tipo SRDT, aprobado por el U.L., a través del anclaje de cable.
4. Conecte el conductor neutro del cordón eléctrico (cable central) al borne central plateado del tablero de bornes. Apriete firmemente el tornillo.
5. Conecte los dos conductores externos restantes del cordón eléctrico a los bornes bronceados externos del tablero de bornes. Apriete firmemente los tornillos.
No doble en forma pronunciada ni engarce
los cables/conductores en las conexiones.
6. Coloque nuevamente el soporte de montaje del anclaje de cable en la parte trasera de la secadora con dos tornillos. Apriete firmemente los tornillos.
7. Apriete firmemente los tornillos del anclaje de cable contra el cordón eléctrico.
8. Apriete la tuerca del anclaje de cable a fin de que el anclaje no gire.
9. Coloque nuevamente la cubierta del tablero de bornes.
14
TORNILLO VERDE DE PUESTA A TIERRA
CABLE DE PUESTA A TIERRA NEUTRAL
ROJO
CONDUCTOR VERDE DE CORDÓN ELÉCTRICO
SOPORTE
DE MONTAJE
DEL ANCLAJE
DE CABLE
CORDÓN ELÉCTRICO
BORNE PLATEADO
NEGRO
BLANCO
TUERCA
TABLERO DE BORNES
ATORNILLE LA TUERCA EN ESTAS ROSCAS
CONEXIÓNES ELÉCTRICAS PARA UN SISTEMA
TETRAFILAR
Secadoras ELÉCTRICAS
1. Saque los tornillos que sujetan la cubierta de acceso del tablero de bornes y el soporte de montaje del anclaje de cable situado en la esquina superior en la parte trasera de la secadora.
2. Instale un anclaje de cable aprobado por el U.L., en el orificio de entrada del cordón eléctrico en el soporte de montaje. Luego apriete la tuerca con los dedos solamente.
3. Desconecte el cable de puesta a tierra neutral del tornillo verde de puesta a tierra situado en la parte superior del tablero de bornes.
TOMACORRIENTE TETRAFILAR TIPICO
CORDÓN ELÉCTRICO TETRAFILAR TIPICO
CORDÓN ELÉCTRICO DE 30 AMP NEMA 14-30 TIPO SRDT O ST
4. Inserte un cordón eléctrico tetrafilar de 30 amp, NEMA 10-30 Tipo ST o SRDT, aprobado por el U.L., a través del anclaje de cable.
5. Conecte el cable verde de puesta a tierra del cordón eléctrico al gabinete mediante el tornillo verde de puesta a tierra.
6. Conecte el conductor blanco (neutro) del cordón eléctrico y el cable de puesta a tierra neutro del mazo de cables de la secadora al borne plateado central del tablero de bornes.
7. Conecte los conductores rojo y negro del cordón eléctrico a los bornes bronceados externos del tablero de bornes.
No doble en forma pronunciada ni
engarce los cables/conductores en las conexiónes.
8. Apriete firmemente los tornillos del anclaje de cable contra el cordón eléctrico.
9. Apriete la tuerca del anclaje de cable a fin de que el anclaje no gire.
10. Coloque nuevamente la cubierta del tablero de bornes.
240 V NEGRO
NEUTRO BLANCO
240 V ROJO
PUESTA A TIERRA VERDE
1. Saque la tapa de embarque de la tubería de gas de la secadora situada en la parte trasera.
NOTA: NO conecte la secadora al suministro de propano, sin convertìr la
2. Conecte una tubería semirígida de 1/2" (1,27 cm) D.I. o una tubería
3. Abra la válvula de cierre en la línea de suminístro del gas para permitir al
válvula del gas. Un juego de conversión a propano debe ser instalado por un técnico de gas calificado.
aprobada, desde la línea de suministro de gas a la tubería de 3/8" (0,96 cm) ubicada en la parte trasera de la secadora (ver páginas 6 y 7). Utilice un reductor de 1/2" (1,27 cm) a 3/8" (0,96 cm) para la conexión. Aplique un sellador de roscas de uso aprobado, resistente a la corrosión de los gases licuados, en todas las uniones de la tubería.
gas de fluir en la tubería.
Válvula abierta / Posición para el flujo del gas
CONEXIÓN DEL GAS
4. Pruebe todas las conexiones aplicando con una escobilla una solución jabonosa. NUNCA UTILICE UNA LLAMA ABIERTA PARA DETECTAR
SI HAY FUGAS DE GAS.
GENERAL INSTALACIÓN
1. Conecte el ducto de escape al sistema de escape exterior (ver páginas 3 y 4). Utilice cinta para ducto para obturar todas las uniones.
2. Con la secadora en su posición definitiva, ajuste una o más patas niveladores, hasta que la secadora repose firmemente sobre las cuatro patas. Coloque un nivel sobre la parte superior de la secadora. LA
SECADORA DEBE ESTAR A NIVEL Y REPOSAR SOLIDA SOBRE LAS CUATRO PATAS NIVELADORES.
3. Conecte el cordón eléctrico a un tomacorriente puesto a tierra. NOTA: Asegúrese de que la corriente esté desconectada en el disyuntor/caja de fusibles, antes de conectar el cordón eléctrico en el tomacorriente.
4. Conecte la corriente en el disyuntor/caja de fusibles.
asegúrese de que no haya materiales combustibles, gasolina y otros vapores inflamables cerca de la secadora. Además asegúrese de que no haya nada (tal como cajas, ropas, etc.) que obstruya el flujo del aire de combustión y ventilación.
5. Haga funcionar la secadora durante un ciclo completo para comprobar su buen funcionamiento. NOTA: En las secadoras a gas, antes de encender el quemador es necesario purgar el aire de la tubería del gas. Si el quemador no enciende dentro de 45 segundos, cuando la secadora se enciende por primera vez, el interruptor de seguridad apagará el quemador. Si ésto sucede, gire el contador de tiempo a la posición "OFF" (apagado) y espere 5 minutos antes de intentar encender la secadora nuevamente.
6. Si su secadora no funciona, consulte la sección "Lista de Control de Averías" que se encuentra en su Manual del Usuario, antes de llamar para obtener servicio.
7. Conserve estas instrucciones cerca de la secadora para referencia
futura.
NOTA: Un cableado diagrama está situado dentro de la consola de parte posterior de la secadora o en el interior de la secadora cerca del motor.
PIEZAS DE RECAMBIO Pedestal
Un accesorio del pedestal diseñó, Número de Modelo APWD15W, especificamente para esta secadora puede ser utilizado al elevar la secadora para la facilidad de empleo. La falta de utilizar los accesorios certificados por el fabricante podía dar lugar a daños corporales, a daños materiales, o a daño a la secadora. Si necesita obtener piezas de recambio para su secadora, póngase en contacto
con el distribuidor donde compró su secadora, llame 1-800-944-9044, o visitan nuestros website www.frigidaire.com, para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted.
etiquetas antes de desconectarlos. Cualquier error de cableado puede causar una operación inadecuada y peligrosa. Asegúrese de que la secadora funcione adecuadamente después de repararla.
después de haber desempacado la secadora. Los niños pueden ponerse a jugar con ellos. Las cajas de cartón cubiertas con alfombras, colchas o pedazos de plástico pueden convertirse en cámaras sin aire y causar asfixia. Elimine todos los materiales poniéndolos en la basura o fuera del alcance de los niños.
la documentación que se entrega con la secadora no pueden cubrir todas las situaciones o condiciones posibles que puedan presentarse. Por lo tanto, se DEBEN seguir prácticas seguras y tener cuidado cuando se instala, pone en funcionamiento y mantiene cualquier artefacto doméstico.
Antes de poner en funcionamiento la secadora,
Cuando se reparan los controles, marque todos los cables con
Destruya la caja de cartón y las bolsas de plástico
Las instrucciones incluidas en este manual y en el resto de
15
Loading...