Frigidaire 220035201066 Owner’s Manual

SPLIT TYPE ROOM AIR CONDITIONER
OWNER'S MANUAL
utions carefully and thoroughly before
From the Electrolux Group.
Welcome to the world of
simple handling and no worries.
Contents
information required to guarantee your safety and the appropriate use of
your air conditioner.
Please read all of the instructions before using the air conditioner and keep
this manual for future reference. We know you will enjoy your new air conditioner and thank you for
choosing our product. We hope you will consider us for future purchase.
The air conditioner that you have
bought may be slightly different from
the one illustrated in this manual,
Please refer to the information related
to the model you have. This air conditioner is for domestic use
only. It is not reccomended for
commercial or industrial use.
The air conditioner you have may carry
a different plug than the one illustrated in this manual. The plug that comes
with the product follows the electrical
specification of the country where it is sold.
Safety precaution ................................................................................. 03
Installation ........................................................................................... 07
Part list ................................................................................................. 09
Indoor unit installation ......................................................................... 11
Outdoor unit installation ....................................................................... 14
Refrigerant piping connection ................................................................ 16
Electrical work ...................................................................................... 18
Electrical safety ..................................................................................... 24
Gas leak control ................................................................................ 24
Test running .......................................................................................... 25
Preparing the device for operation ...................................................... 26
Product description ............................................................................. 27
Remote control functions ..................................................................... 29
Remote control operations .................................................................... 31
How the air conditioner works ................................................................ 34
Adjusting air flow direction ................................................................... 38
Manual operation ................................................................................ 40
Cleaning and maintenance .................................................................. 41
Operation tips ........................................................................................ 43
Troubleshooting tips ............................................................................ 45
Environmental advices ......................................................................... 46
Technical informations ......................................................................... 47
Safety precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
1. Connect with the power properly. Otherwise, it may cause electric
shock or fire due to excess heat generation.
2. Do not modify power cord length or share the outlet with other
appliances. It may cause electric shock or fire
due to heat generation.
3. Always ensure effective earthing. No earthing may cause electric
shock.
4. Disconnect the power if strange sounds, smell, or smoke comes from it.
It may cause fire and electric shock.
5. Keep firearms away. It may cause fire.
6. Do not operate or stop the unit by switching on or off the power.
It may cause electric shock or fire due to heat generation.
7. Do not operate with wet hands or in damp environment.
It may cause electric shock.
8. Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
9. Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
10. Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
11. Do not damage or use an unspecified power cord.
It may cause electric shock or fire.
12. Do not direct airflow at room occupants only.
This could damage your health.
13. Always install circuit breaker and a dedicated power circuit.
No installation may cause fire and electric shock.
14. Do not open the unit during operation.
It may cause electric shock.
15. Do not use the power cord near
flammable gas or combustibles,
such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
16. Ventilate room before operating air conditioner if there is a gas
leakage from another appliance. It may cause explosion, fire and, burns.
17. Do not disassemble or modify unit. It may cause failure and
electric shock.
18. When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury.
19.Donotcleantheairconditioner withwater.
Watermayentertheunitand degradetheinsulation.
Itmaycauseanelectricshock.
20.Ventilatetheroomwellwhenused togetherwithastove,etc.
Anoxygenshortagemayoccur.
21.Whentheunitistobecleaned, switchoff,andturnoffthecircuit
breaker. Donotcleanunitwhenpoweris
onasitmaycausefireand electricshock,itmaycausean
injury.
22.Donotputapetorhouseplant whereitwillbeexposedtodirect
airflow. Thiscouldinjurethepetorplant.
23.Donotuseforspecialpurposes.
Donotusethisairconditionerto preserveprecisiondevices,food,
pets,plants,andartobjects.It maycausedeteriorationofquality,
etc.
24.Stopoperationandclosethe windowinstormorhurricane.
Operationwithwindowsopened
maycausewettingofindoorand
soakingofhouseholdfurniture.
25.Donotplaceobstaclesaroundair-
inletsorinsideofair-outlet. Itmaycausefailureofappliance
oraccident.
26.Turnoffthemainpowerswitch whennotusingtheunitforalong
time.
Itmaycausefailureofproductor
fire.
27.Donotusestrongdetergentsuch aswaxorthinner.Useasoftcloth
forcleaning. Appearancemaybedeteriorated
duetochangeofproductcoloror scratchingofitssurface.
28.Ensurethattheinstallationbracket oftheoutdoorapplianceisnot
damagedduetoprolonged exposure.
Ifbracketisdamaged,thereis concernofdamageduetofalling
ofunit.
29.Alwaysinsertthefilterssecurely. Cleanfilteronceeverytwoweeks.
Operationwithoutfiltersmay causefailure.
30.Donotplaceheavyobjectonthe powercordandtakecaresothat thecordisnotcompressed.
Thereisdangeroffireorelectric shock.
Usecautionwhenunpackingand installing.Sharpedgescouldcause
injury. Ifwaterenterstheunit,turntheunit
offanddisconnectthepower,contact aqualifiedservicetechnician.
Installation
Choosing the installation site
Precautions for installation
Installation at the following sites may cause problems. If you must inevitably
install the unit at one of these sites, please consult your local distributor beforehand:
1. Site with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
indoor unit
1. The unit must be installed at a site that does not obstruct the flow of
air.
2. The site must support the weight of the indoor unit.
3. The site must be easily accessible for maintenance and replacement
of the air filter.
7. The indoor unit must be at least
2.3 meters (7.5 feet) from the ground.
8. The site must allow for the easy removal of the connector pipe and drain hose.
9. The unit must be installed at a site protected from direct sunlight.
4. The site must allow for the necessary space around the
indoor unit, as shown in the
following figure.
More than
12cm
More than 15cm
5. There should be at least 1 meter (3
feet) between the unit and radio
and television devices. It is ideal
that the unit be installed at the
center of the environment.
6. It must be far from fire, smoke or
flammable gases.
More than 230cm
More than 12cm
Outdoor unit
1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated.
2. The site must support the weight of the outdoor unit and allow for vertical installation.
3. There must not be the possibility of increased noise and vibration at the site.
4. The unit must be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or animals.
5. The site cannot have any leakage of flammable gases.
6. The site must allow for a piping extension of no less than 5 meters (16 feet) and for pipes measuring at least 10 meters (33 feet) in length.
7. The site must provide enough space around the unit, as shown in the diagram.
8. Children must not be able to access the installation site.
More
More than 10cm
More
than 60cm
More than 60cm
Part list
more than 15cm_
Rndoorunit
More than 12cm
\ ......... J
Air Filter <_
More than 30cm
A
More than 60cm
More than 60cm
Indoor unit
O
Outdoor unit
B C
More than 200cm Outdoor
Unit
The indoor unit should be installed no lower than 2,3 m. The pipe needs the minimun of 4 or 5 meters, this distance will contribute to
avoid vibration or noise. Two of the three direction above (A, B, C) should be not be blocker. The copper
pipe can be isolated independent.
Indoor unit installation
Installation plate drilling and assembly
Indoor unit outline Installationplate
150mm or more to ceiling
f"..... i
or more i _ o
to wall ' _ oJ
120mm
Right refrigerant _" "................... "_ ....................pipe hole: a 65
A:780(Modelos< 16000 Btu/h), 920(Modelos>f 16000 Btu/h)
Fixing the installation plate:
1. Fit the installation plate horizontally on structural parts of the walt with spaces around the installation
plate.
2. If the wal! is made of brick, concrete or the like, drill eight (8)
5mm diameter holes in the wall. Insert Clip anchor for appropriate
mounting screws.
3. Fit the installation plate on the wall with eight (8) type "A" screws..
Fit the Installation Plate and drill holes in
the wall according to the wall structure and corresponding mounting points on
the installation plate. (Dimensions are in "mm" unless otherwise stated)
© ® ®
Placa de instalaci6n
120ram or more
to wall
Right refrigerant pipe hole G 65
Connective pipe and drainage installation
Drainage
1. Run the drain hose sloping downward. Do not install the drain
hose as illustrated beside.
2. When connection extension drain
hose, insulate the connecting part
of extension drain hose with a shield pipe.
Connection pipe
1. For the left-hand and right-hand piping, remove the rear plate bushing from the left side of the rear plate. Explain to clients that the pipe cover must be kept as it may be
used when relocate the air conditioner to any other place.
2. For the left-hand and rearqeft-hand piping, install the piping as shown.
Bend the connective pipe to be laid at 43mm height or less from
the wall.
_Do not block r//i Do not block
Right piping _ Right back piping
water flow _1 water flow
Do not put the end of
hose into water.
Piper Pipe holder Pipe cover (right) Cover (left)
_ Left back
ping
Indoor unit outline
\
i i
i
Connective pipe
\
, VE
, E
I co
Drill a hole in the wall
1. Determine hole positions according to the diagram detailed in figure
beside. Drill one (!) hole (65mm)
slanting slightly to outdoor side.
2. Always use wal! hole conduit when drilling metal grid, metal plate or
the like..
Wall
Indoorunit ] _ I Outd°°r unit l
Superior hook \
Fastening the indoor unit Pass the drain hose through the hole
in the wall and connect the indoor unit
to the installation plate, pressing the
indoor part of the installation plate hooks.
hook
Outdoor unit installation
3. Piping can easily be made by lifting the indoor unit with a cushion
material between the indoor unit and the wall. Get it out after finish
piping.
4. Push the lower part of the Indoor
Unit up on the wall. Then move the Indoor Unit from side to side, up
and down to check if it is hooked securely.
Piping and wrapping
1. Wind the connective cable, drain hose and wiring with tape / Indoor unit /P°nd box
securely, evenly as shown beside.
2. Because the condensed water Connective Piperoom from rear of the indoor unit is Connective
gathered in Pond Box and is piped _e out of room. Do not put anything
else in the box. wrapping belt
1. Connect the indoor unit first then the outdoor unit and bend and arrange the pipe carefully.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Insulate both of the auxiliary piping.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
\
Manguera
de desagQe
Shock absorber piece
1. Install the outdoor unit on a rigid base to prevent increasing noise
level and vibration.
2. Determine the air outlet direction where the discharged air is not
blocked.
3. In the case that the installation
place is exposed to strong wind such as a seaside operation by putting the unit lengthwise along
the wall or using a dust or shield
plates.
4. Specially in windy area, install the
unit to prevent the admission of
wind.
5. If need suspending installation, the
installation bracket should accord
with technique requirement in the
installation bracket diagram. The installation wal! should be solid
brick, concrete or the same intensity construction, or actions to
reinforce, damping supporting should be taken. The connection
between bracket and walt, bracket and the air conditioner should be
firm, stable and reliable..
6. Be sure there is no obstacle which
block radiating air.
Strong winds
13)
Refrigerant piping connection
Settlement of outdoor
unitAnchor the outdoor unit with a bolt and nut 10 or 8 tightly
and horizontally on a concrete or
rigid mount.
Drain elbow installation Fit the seat into the drain elbow, then
insert the drain elbow into
the base pan hole of outdoor unit,
rotate 90 ° to securely assemble them. Connecting the drain elbow with an
extension drain hose (Locally
purchased), in case of the water
draining off the outdoor unit during the
heating mode.
Flaring work Main cause for refrigerant leakage is
Air
due to defect in the flaring work.
Carry out correct flaring work sing the
following procedure:
'_ All outlet
1.
Cut the pipes and the cable.
Pipe
A) Use the piping kit accessory or
pipes purchased locally.
B) Measure the distance between the indoor and the outdoor unit.
Right Wrong
C) Cut the pipes a little longer than the measured distance.
D) Cut the cable 1.5m longer than
9 °_ Beveled_ Unequal_ jlpR°u_h
the pipe length.
2.
Burr removal.
A) Completely remove all burrs
from the cut cross section of
pipe/tube.
B) Put the end of the copper
Pipe
tube/pipe in a downward direction
Base pan hole of outdoor unit
as you remove burrs in order to avoid dropping burrs into the
tubing.
3.
Putting nut on.
Point down
A) Remove flare nuts attached to
indoor and outdoor unit, then put
Flare nut //_
them on pipe/tube having completed burr removat.(not
¢
possible to put them on after flaring
work)
Copper tub_
Seal Drain elbow Drain elbow