Frieling MILKchiller 0601 User Manual

OWNER’S MANUAL
Model No. 0501 and 0601
MILKchiller
by
Important Safeguards
When using an electrical appliance, basic safety precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following:
1. Read all instructions before using appliance.
2. Close supervision is necessary when any appliance is used near children.
3. This appliance is not for use by children.
4. The cord to this appliance should be plugged into a 120V AC electrical outlet only.
5. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been dropped or damaged in any manner. Contact Consumer Service for return authorization, examination, repair or adjustment.
6. If this appliance malfunctions during use, immediately unplug the cord from the outlet. Do not attempt to repair the malfunctioning appliance.
7. Unplug unit when not in use and before cleaning.
8. Do not let the power supply hang over edge of table or counter.
9. Use caution when transporting MILKchiller™.
10. Do not place on or near a hot gas or electric burner, or in a heated oven.
11. The use of accessory attachments is not recommended by the manufacturer as it may cause injuries.
12. Use MILKchiller™ unit only with the provided base and on a flat surface.
SAVE THESE INSTRUCTIONS
2
Important Safeguards (cont.)
CAUTION: Do not block the cooling fan in the back of the unit nor the exhaust ports on the side the MILKchiller™. Allow ample space for air circulation.
CAUTION: Do not immerse the power-supply, cord, or appliance in water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the appliance. Pieces of the pad may break off and touch electrical parts.
CAUTION: Do not pour water or any liquid into the chilling chamber of the MILKchiller™.
CAUTION: The room temperature for normal operation of the MILKchiller™ is below 30°C, 86°F. We cannot guarantee proper functioning of the MILKchiller™ in a room or environment above these temperatures.
Polarized Plug
This appliance has a polarized plug (one blade is wider that the other). As a safety feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to modify the plug in any way.
Power Cord Instructions
A long power cord is provided so that the MILKchiller™ can be located away from the power outlet. Care must be taken to ensure the cord does not become entangled or located where tripping can occur.
3
MILKchiller™ Parts and Accessories
7
6
1
2
5
3
4
Parts List Item No.
1. MILKchiller™ unit 0501 or 0601
2. Power Supply and Plug 0713
3. Base with Drip Tray Cup 0721
4. Drip Tray Insert 0710
5. Drip Tray Metal platform 0711
6. Disposable Straw for Plastic Cartons and MILKchiller™ Refillable Container
7. Disposable Straw for Paper Cartons 0701
8. MILKchiller™ Refillable Container Lid (available separately, not included)
9. MILKchiller™ Refillable Container (available separately, not included)
10. Air Filter 0705
11. Wire tie
12. Pipette
8
9
10
11
12
0702
0723
0724
0725
Please see pages 20 - 23 for complete parts/accessory order details.
4
Congratulations!
MILKchiller™ is the unique solution for your beverage station because it…
Maintains dairy products at a safe temperature of 41ºF or below.
Features an LCD displays 8 types of dairy products: whole; cream; ½ & ½; 1%; 2%; skim; fat-free; and soy; in 5 different languages: English, French, German, Italian and Spanish.
Accommodates standard ½ gallon dairy cartons or plastic containers.
Will also accommodate the dishwasher safe, MILKchiller™ Refillable Container.
Dispenses dairy products with a simple press of a button.
Eliminates mess and waste.
Is easy to operate and to replace the dairy container.
Before Using for the First Time
1. Carefully unpack the MILKchiller™ from the box.
2. Read all of the instructions included in this manual.
3. Remove all the packing material including the white wrappers protecting the stainless steel components.
4. Make sure the MILKchiller™ is unplugged and the power switch is in the OFF position.
5. Wipe exterior surfaces with a damp cloth. Dry thoroughly with a soft cloth. DO NOT use harsh or abrasive cleansers as these can damage the exterior surfaces.
CAUTION: Do not immerse the power supply, the cord, or the appliance in water or any other liquid.
6. If purchased, remove the MILKchiller™ Refillable Container and lid. Wash them in warm, soapy water or in the upper rack of the dishwasher.
7. Thoroughly dry the MILKchiller™ Refillable Container and lid.
5
The MILKchiller™ is now ready for use.
Plug the power supply connector into the Power Input on the MILKchiller™ control panel. Connect the power supply to the power cord and plug it into the wall outlet. Set the Power Switch to ON.
Power Supply Connector
Power Inlet
Power Switch
Upon start up, the LCD will alternately flash COOLING, LOW and WHOLE until the MILKchiller™ has reached the safety standard temperature. (The “LOW” message will disappear when the full carton or container is inserted into the chilling chamber.) When it has reached the safety standard temperature, the LCD will display the default setting “WHOLE”.
For more information on the setting display, please see the section DISPLAY SETTINGS and CONTROL PANEL FUNCTIONS.
6
Fine Tuning the Low Level Indicator
The Low Level Indicator has been calibrated to trigger at approximately 18 ounces, 1/4 of a carton. This is the minimum amount of liquid remaining in the carton when the LOW indicator flashes. The Low Level Indication can be adjusted to trigger for more liquid remaining in the carton if desired.
1. Locate the calibration screw on the underside of the MilkChiller™ just behind the drip tray.
2. Fill a container 1/4 full or more with liquid. This is the approximate amount of dairy product remaining in the container when the LOW indicator flashes on the display.
Place container in the MilkChiller™ and close the lid.
3. Place the MilkChiller™ on a flat surface that will provide access to the calibration screw. We suggest using an inside corner of a counter, or pushing two tables together leaving 2 inches between them for access to the screw.
4. Using a flathead screwdriver, SLOWLY adjust screw on the bottom in a clockwise manner just until the LOW indicator is flashing.
5. Further adjust the screw ½ turn to complete the calibration.
If, after time, the LOW indicator does not flash at the desired liquid level, readjust the calibration screw as outlined above.
7
The MILKchiller™ can now be loaded with a ½ gallon paper carton or the MILKchiller™ Refillable Container filled with dairy product.
It is required to refrigerate all dairy products prior to use in the MILKchiller™. If using shelf stable milk, the MILKchiller™ will not operate until the milk has cooled to the safe temperature specification.
How To Insert Disposable Straw into MILKchiller™ Refillable Container:
1. Unscrew lid from container.
2. Fill container with dairy product up to the MAX Fill Line.
3. Screw on lid.
4. Insert Disposable Straw for Plastic into opening in lid orienting the holes front to back as shown.
5. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into Paper Half Gallon Container:
1. Unscrew the cap and remove the inner seal on the pour spout.
2. Insert the Disposable Straw for Paper into the pour spout.
3. Ensure the straw is pointing forward and orient the holes side by side as shown.
4. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into Plastic Half Gallon Container:
1. Remove the cap on the pour spout.
2. Pour out roughly 2 oz. of milk from plastic half
gallon container.*
3. Insert the Disposable Straw for Plastic into the pour spout and orient the holes front to back as shown.
4. Press straw cap into opening for a tight fit.
* Some dairy factories fill plastic containers to the top. This overfilling can cause some liquid to spill when the container is inserted into the chilling chamber. Therefore we recommend pouring out
some liquid before inserting the straw.
If the Disposable Straw cap does not fit into the pour spout on the container, please use the MILKchiller™ Refillable Container.
8
Loading...
+ 17 hidden pages