When using an electrical appliance, basic safety precautions should
always be followed to reduce the risk of fire, electrical shock and injury to
persons, including the following:
1. Read all instructions before using appliance.
2. Close supervision is necessary when any appliance is used near
children.
3. This appliance is not for use by children.
4. The cord to this appliance should be plugged into a 120V AC
electrical outlet only.
5. Do not operate any appliance with a damaged cord or plug or after
the appliance malfunctions, or has been dropped or damaged in
any manner. Contact Consumer Service for return authorization,
examination, repair or adjustment.
6. If this appliance malfunctions during use, immediately unplug the
cord from the outlet. Do not attempt to repair the malfunctioning
appliance.
7. Unplug unit when not in use and before cleaning.
8. Do not let the power supply hang over edge of table or counter.
9. Use caution when transporting MILKchiller™.
10. Do not place on or near a hot gas or electric burner, or in a heated
oven.
11. The use of accessory attachments is not recommended by the
manufacturer as it may cause injuries.
12. Use MILKchiller™ unit only with the provided base and on a flat
surface.
SAVE THESE INSTRUCTIONS
2
Important Safeguards (cont.)
CAUTION: Do not block the cooling fan in the back of the unit nor the
exhaust ports on the side the MILKchiller™. Allow ample space for air
circulation.
CAUTION: Do not immerse the power-supply, cord, or appliance in
water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the appliance.
Pieces of the pad may break off and touch electrical parts.
CAUTION: Do not pour water or any liquid into the chilling chamber
of the MILKchiller™.
CAUTION: The room temperature for normal operation of the
MILKchiller™ is below 30°C, 86°F. We cannot guarantee proper
functioning of the MILKchiller™ in a room or environment above these
temperatures.
Polarized Plug
This appliance has a polarized plug (one blade is wider that the other).
As a safety feature to reduce the risk of electrical shock, this plug is
intended to fit in a polarized outlet only one way. If the plug does not
fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician. Do not attempt to modify the plug in any way.
Power Cord Instructions
A long power cord is provided so that the MILKchiller™ can be located
away from the power outlet. Care must be taken to ensure the cord does
not become entangled or located where tripping can occur.
3
MILKchiller™
Parts and Accessories
7
6
1
2
5
3
4
Parts ListItem No.
1.MILKchiller™ unit0501 or 0601
2.Power Supply and Plug0713
3.Base with Drip Tray Cup0721
4.Drip Tray Insert0710
5.Drip Tray Metal platform0711
6.Disposable Straw for Plastic Cartons
and MILKchiller™ Refillable Container
7.Disposable Straw for Paper Cartons0701
8.MILKchiller™ Refillable Container Lid
(available separately, not included)
9.MILKchiller™ Refillable Container
(available separately, not included)
10. Air Filter0705
11. Wire tie
12. Pipette
8
9
10
11
12
0702
0723
0724
0725
Please see pages 20 - 23 for complete parts/accessory order details.
4
Congratulations!
MILKchiller™ is the unique solution for your beverage station because
it…
• Maintains dairy products at a safe temperature of 41ºF or below.
• Features an LCD displays 8 types of dairy products: whole;
cream; ½ & ½; 1%; 2%; skim; fat-free; and soy; in 5 different
languages: English, French, German, Italian and Spanish.
• Accommodates standard ½ gallon dairy cartons or plastic
containers.
• Will also accommodate the dishwasher safe, MILKchiller™
Refillable Container.
• Dispenses dairy products with a simple press of a button.
• Eliminates mess and waste.
• Is easy to operate and to replace the dairy container.
Before Using for the First Time
1. Carefully unpack the MILKchiller™ from the box.
2. Read all of the instructions included in this manual.
3. Remove all the packing material including the white wrappers
protecting the stainless steel components.
4. Make sure the MILKchiller™ is unplugged and the power switch
is in the OFF position.
5. Wipe exterior surfaces with a damp cloth. Dry thoroughly with a
soft cloth. DO NOT use harsh or abrasive cleansers as these can
damage the exterior surfaces.
CAUTION: Do not immerse the power supply, the cord, or the
appliance in water or any other liquid.
6. If purchased, remove the MILKchiller™ Refillable Container
and lid. Wash them in warm, soapy water or in the upper rack of
the dishwasher.
7. Thoroughly dry the MILKchiller™ Refillable Container and lid.
5
The MILKchiller™ is now ready for use.
Plug the power supply connector into the Power Input on the
MILKchiller™ control panel. Connect the power supply to the power
cord and plug it into the wall outlet. Set the Power Switch to ON.
Power Supply
Connector
Power Inlet
Power Switch
Upon start up, the LCD will alternately flash COOLING, LOW and
WHOLE until the MILKchiller™ has reached the safety standard
temperature. (The “LOW” message will disappear when the full carton
or container is inserted into the chilling chamber.)
When it has reached the safety standard temperature, the LCD will
display the default setting “WHOLE”.
For more information on the setting display, please see the section
DISPLAY SETTINGS and CONTROL PANEL FUNCTIONS.
6
Fine Tuning the Low Level Indicator
The Low Level Indicator has been calibrated
to trigger at approximately 18 ounces, 1/4 of
a carton. This is the minimum amount of
liquid remaining in the carton when the LOW
indicator flashes. The Low Level Indication
can be adjusted to trigger for more liquid
remaining in the carton if desired.
1. Locate the calibration screw on
the underside of the MilkChiller™
just behind the drip tray.
2. Fill a container 1/4 full or more with liquid.
This is the approximate amount of dairy product
remaining in the container when the LOW indicator
flashes on the display.
Place container in the MilkChiller™ and close the lid.
3. Place the MilkChiller™ on a flat
surface that will provide access to the
calibration screw. We suggest using an
inside corner of a counter, or pushing two
tables together leaving 2 inches between
them for access to the screw.
4. Using a flathead screwdriver, SLOWLY
adjust screw on the bottom in a clockwise
manner just until the LOW indicator is
flashing.
5. Further adjust the screw ½ turn to
complete the calibration.
If, after time, the LOW indicator does not
flash at the desired liquid level, readjust the
calibration screw as outlined above.
7
The MILKchiller™ can now be loaded with a ½ gallon paper carton or the
MILKchiller™ Refillable Container filled with dairy product.
It is required to refrigerate all dairy products prior to use in the MILKchiller™.
If using shelf stable milk, the MILKchiller™ will not operate until the milk has
cooled to the safe temperature specification.
How To Insert Disposable Straw into
MILKchiller™ Refillable Container:
1. Unscrew lid from container.
2. Fill container with dairy product up to the
MAX Fill Line.
3. Screw on lid.
4. Insert Disposable Straw for Plastic into
opening in lid orienting the holes front to back
as shown.
5. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into
Paper Half Gallon Container:
1. Unscrew the cap and remove the inner seal on
the pour spout.
2. Insert the Disposable Straw for Paper into the
pour spout.
3. Ensure the straw is pointing forward and
orient the holes side by side as shown.
4. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into
Plastic Half Gallon Container:
1. Remove the cap on the pour spout.
2. Pour out roughly 2 oz. of milk from plastic half
gallon container.*
3. Insert the Disposable Straw for Plastic into the
pour spout and orient the holes front to back as
shown.
4. Press straw cap into opening for a tight fit.
* Some dairy factories fill plastic containers to
the top. This overfilling can cause some liquid to
spill when the container is inserted into the chilling
chamber. Therefore we recommend pouring out
some liquid before inserting the straw.
If the Disposable Straw cap does not fit into the pour spout on the
container, please use the MILKchiller™ Refillable Container.
8
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.