Friedrich US12C10, US08C10, US14C30, WE10C33, WE13C33 Specifications

...
Page 1
T H R U - T H E - W A L L A I R C O N D I T I O N E R S
26” AND 27” SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
Page 2
W A L L M A S T E R® T H R U - T H E - W A L L A I R C O N D I T I O N E R S
27” SLEEVE
Q U A L I T Y
Ideal for new construction, and as a high efficiency replacement in retrofits and remodels
Features
• High efciency operation saves on energy costs
• Residential/commercial applications
• Heat pumps and electric heat models
• Ideal for thicker wall installations, where side ns don’t t
Digital Control Features
• Remote control
• 24 hour programmable timer
• Money Saver® setting saves money by conserving energy
• Smart Fan auto-adjusts fan speed to maintain desired temperature
• A high efciency replacement for 27" sleeves including Fedders A and B*. Sleeve measures 27" W x 16 3/4" H
• Easy-to-reach, top mount controls
• Three-speed fan
• Efcient rotary compressor
• Easy-to-clean lter
• Auto restart
• Auto-memory backup saves settings should power be interrupted
Unit i s shown installed in WSD sleeve (sold and shipped separately) *Installation in Fedders B sleeve requires a baf e kit. See BAK acce ssory under accessories.
WallMaster
COOLING HEATING
7,800-14,500 BTU/h 7,300-11,000 BTU/h Up to 9.9 EER
Sleeve Dimensions
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
Friedrich
WSD Sleeve
®
Fedders A Sleeve
Fedders
B Sleeve*
Page 3
U N I - F I T® T H R U - T H E - W A L L A I R C O N D I T I O N E R S
26” SLEEVE Universal fit for easy replacement in
existing 26” sleeves
Features
• Rotary compressors provide quiet, dependable performance
• Six-way air ow control
• Auto restart
• Washable/reusable lter
• Seacoast protection
• Stale air exhaust
Digital Control Features
• 12 hour programmable timer
• Money Saver® setting saves money by conserving energy
Units are shown w itho ut USC sleeve (USC sleeves sol d and shipped separately)
Uni-Fit
®
COOLING HEATING
8,000-13,000 BTU/h 3,850-11,200 BTU/h Up to 9.6 EER
Friedrich
Sleeve Dimensions
Height (inches) 15 1/2 15 5/8 16 7/8 16 3/4 15 3/4 15 5/8 16 1/2 15 1/4
Width (inches) 25 7/8 26 25 3/4 27 26 3/4 26 25 7/8 25 1/2
Depth (inches) 16 3/4 16 7/8 18 5/8 16 3/4 or
USC
Sleeve Amana
Carrier
(51S
Series)
Fedders/
Emerson/
Friedrich
WSD
19 3/4
Emerson/
Fedders
15 16 7/8 17 1/8
GE/
Hotpoint Whirlpool
or 23
White-
Westinghouse/
Frigidaire/
Carrier (52F
Series)
16, 17 1/2
or 22
Page 4
Commercial & Residential Applications
When should you install a solid side sleeve?
SOLID SIDE wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty.
ROOM AIR CONDITIONER
Blocked side vents restrict air ow
THRU-THE-WALL units mount ush with exterior walls for a sleek appearance, as well as unobstructed window views.
(Wallmaster WSD sleeve shown with architectural grille. Uni-t grille has different appearance.)
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can be installed ush with exterior wall.
Page 5
16 3/4"
Fedder s B
19 3/4”
Model Heigh t Width De pth
Depth
with
Front
Minim um Ext ension Into Ro om
Minim um
Ext ension
Outs ide
Thru -the-wall
Finished Ho le
Height Width Max . Depth
WALLMAS TER
WSD Sleeve 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16"
Chassis 15 3/4" 26 1/2" 21" 22” – – – – –
UNI-FIT
USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" – 1/2" 15 3/4" 26 1/8" 16 1/4"
US Chassis 14 3/8" 24" 20 1/8" 3 3/4" – – – –
UE Chas sis 14 3/8" 24 5/8" 19 5/8" 3 1/2" – – – –
WallMaster
WSD Sleeve Standard Grille - Ships
®
27” Sleeve Exterior Grilles
WSD Sleeve Optional Architectural Grille- AG
with sleeve. Galvanized steel weather panel also ships with sleeve.
Installation Accessories (27” sleeve models only)
IMPORTANT: Operating the air conditioner with incorrect rear grille or without Bafe Adapter Kit (on 19 3/4” deep sleeve) will recirculate discharge air and cause compressor overload to trip.
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
DK / Drain Kit Installed at the back of the unit and allows
for attachment to permanent condensate disposal system, if disposal is necessary or desired.
SB / Sub Base
Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall.
Uni-Fit® 26” Sleeve Exterior Grilles
USC Sleeve Standard Grille
Sleeve shown with Replacement Grille
IDK / Internal Drain Kit
New construction applications where a condensate drain system has been built into the wall interior.
BAK / Bafe Adapter Kit
Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).
STANDARD GRILLE – Ships with USC sleeve Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis High-tech plastic for use on existing sleeves without any grille.
IMPORTANT: When installing into an existing sleeve, consult Installation Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a bafe adapter should be used.
Sleeve/Chassis Dimensions
IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements
IMPORTANT: US chassis w/front fully installed into USC sleeve extends into room 3 3/8”. UE chassis w/front fully installed into USC sleeve extends into room 2 7/8”.
US= 3 3/8”, UE= 2 7/8”
Page 6
Specifications
EnErgy Star
®
models
Estar
Model
Cooling
Capacity Btu
Heating
Capacity Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efciecy
Ratio
EER
Estimated
Yearly
Operating
Cost
Moisture Removal Pints/HR
Room
Side Air
Circulation
CFM Sleeve
WALLMASTER
Cool only
WS08C10 7800 NA 115 7.1 788 NA NA 9.9
WS10C10 9700 NA 115 10.0 1032 NA NA 9.4 $82 2.4 257 WSD 103
WS12C10 11900 NA 115 11.8 1266 NA NA 9.4 $101 3.3 295 WSD 112
WS10C30 9500/9200 NA 230/208 4.5/4.7 989/958 NA NA 9.6/9.6 $79 1.5 300 WSD 101
WS13C30 12600/12300 NA 230/208 6.3/6.7 1340/1309 NA NA 9.4/9.4 $107 3.6 290 WSD 109
WS15C30 14500/14500 NA 230/208 8.3/8.2 1706/1706 NA NA 8.5/8.5 $136 4.2 290 WSD 119
Heat Pumps
WY09C33 9300/9000 7300/7300 230/208 4.4/4.7 989/957 3.8/4.0 839/793 9.4/9.4 $79 2.1 250 WSD 103
WY12C33 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 $111 2.6 275 WSD 111
Cool with Electric Heat
WE10C33 9500/9200 11000/9100 230/208 4.5/4.7 989/958 16.0/14.7 3550/2950 9.6/9.6 $79 1.5 300 WSD 121
WE13C33 12600/12300 11000/9100 230/208 6.3/6.7 1340/1309 16.0/14.7 3550/2950 9.4/9.4 $107 3.6 290 WSD 107
WE15C33 14500/14500 11000/9100 230/208 8.3/8.8 1706/1706 16.0/14.7 3550/2950 8.5/8.5 $136 4.2 290 WSD 116
†
1.2 250 WSD 93
UNI-FIT
Cool Only
US08C10 8000 - 115 7.5 830 - - 9.6 $66 2.2 260 USC 73
US10C10 9800 - 115 9.6 1040 - - 9.4 $83 3.2 285 USC 78
US12C10 11500 - 115 11.2 1220 - - 9.4 $97 3.8 290 USC 80
US10C30 10000/9800 - 230/208 4.7/5.2 1060/1040 - - 9.4/9.4 $85 3.2 285 USC 78
US12C30 11500/11200 - 230/208 5.6/6.0 1220/1190 - - 9.4/9.4 $97 3.8 290 USC 80
US14C30 13000/12600 - 230/208 7.0/7.5 1530/1480 - - 9.4/9.4 $122 4.0 310 USC 87
Cool with Electric Heat
UE08C13 8000 3850 115 7.5 830 10.7 1230 9.6 $66 2.2 260 USC 73
UE10C33 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4/9.4 $85 3.2 285 USC 78
UE12C33 11500/11200 11200/9200 230/208 5.6/6.0 1220/1190 15.3/14.0 3500/2900 9.4/9.4 $97 3.8 290 USC 80
WallMaster Heat Pump heating information (shown in red) indic ates heat pump heating performance. WallMaster Electr ic Heat heating information (shown in red) indicates electric heat strip per formance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacit y rating of the unit, the heating perfor­mance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor c omfor t. Below 43°F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/295 0 watts.
DEFROST DR AIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.
Net
Weight
Lbs
Plug Face/ Circuit Rating
WallMaster Model Number
WS 08 C10, WS10C10, WS12 C10
WS10C30, W S13C3 0, WS15 C30
WE10C 33 , W E13 C33, WE15C33 , W Y09C3 3, W Y12 C3 3
Uni-Fit Model Number
US08 C10, UE08C13 US10 C10, US12C10
US10 C30, US12C 30 , US14 C30
Breaker
or T-D Fuse
Plug Face
(NEMA#)
Power Cord Length (ft.)
125 V - 15A 5 - 15P 6
250V - 15 A 6 - 15P 4
UE10 C33, UE12C 33 250V - 20A 6 - 2 0P 4
Power cords are located on front left of WallMaster models and on front right of Uni- Fit models.
Circuit Rating
Due to continuing research in new energy-saving technology, specications are subject to change without notice. As an EnErgy Star® partner, Friedrich Air Conditioning Co. has determined that the selected EnErgy Star® models meet the EnErgy Star® guidelines for energy efciency.
Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh. † The estimated yearly operating cost of this model was not available at the time the range was published.
Friedrich Air Conditioning Co. l P.O. Box 1540 l San Antonio, TX 78295-1540 l 800.541.6645 l fax 210.357.4480 www.friedrich.com
TTW-10 (3-10) Printed in USA
Wall
Outlet
Appearance
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
Loading...