Friedrich VHA24K, VHA09K, VHA12K, VHA18K, VHA09R Engineer's Manual

...
PRODUCT PROFILE
VERT-I-PAK
PRODUCT PROFILE
®
Single Package Vertical Heat Pumps
Features
• Up to 10.4 EER
• Completely self­contained; no outside condensing unit
• Can be installed from any interior side (front, right or left)
Unique free-oating chassis and fully insulated cabinets for improved sound characteristics and unit performance
• Condensate removal system uses slinger ring technology to cool the coil
and increase efciency
• Primary condensate removal system provided
thru 3/4" pipe ttings for
more placement options
Secondary overow from primary drain*
Pre wired, charged and piped
Two-speed fan control
from wireless or wired wall thermostat
Safety power disconnect
5 YR. limited warranty- includes labor
*24000 Btu models (VHA24K & VHA24R) and 18000 BTU model (VHA18K & VHA18R) use secondary gravity-fed drain (VPDP1).
THE EXPERTS IN ROOM AIR CONDITIONING
PRPRF_VPAK_2018 9521 4200_01
CHASSIS SPECIFICATIONS K-Series models 230/208V, R-Series models 265V
MODEL
COOLING DATA
COOLING BTU
POWER (W)
EER
SENSIBLE HEAT RATIO
HEATER SIZE (kW)
HEAT PUMP DATA
REVERSE HEATING BTU
COP @ 47F
HEATING POWER (W)
HEATING CURRENT (A)
ELECTRICAL DATA
VOLTAGE (1 PHASE, 60 HZ)
VOLT RANGE
COOLING CURRENT (A)
AMPS L.R
AMPS F.L.
INDOOR MOTOR (HP)
INDOOR MOTOR (A)
OUTDOOR MOTOR (HP)
OUTDOOR MOTOR (A)
PHYSICAL
DIMENSIONS (W X D X H)
NET WEIGHT (LBS)
SHIPPING WEIGHT (LBS)
TEST SETTING
R410A CHARGE (OZ)
AIRFLOW DATA
INDOOR CFM
.10” ESP
.15” ESP
.20” ESP
.25” ESP
.30” ESP
VENT CFM
VHA09K VHA09R VHA12K VHA12R VHA18K VHA18R VHA24K VHA24R
9400/9400 9400 12200/12000 12400 18200/18000 18000 23000/22800 22500
905/905 915 1220/1200 1240 1825/1800 1815 2527/2505 2475
10.4/10.4 10.3 10.0/10.0 10.0 10.0/10.0 10.0 9.1/9.1 9.1
0.76 0.77 0.75 0.75 0.66 0.70 0.70 0.70
2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0/7.5/10.0 2.5/3.4/5.07/7.5/10.0
8400/8400 8500 11100/10900 11300 16800/16400 16700 20000/20000 20000
3.0/3.0 3.0 3.0/3.0 3.0 3.0/3.0 3.0 3.0/3.0 3.0
830/830 820 1075/1050 1095 1650/1600 1620 1953/1953 1950
4.0/4.0 3.2 5.0/5.3 4.5 7.8/8.3 6.9 8.5/9.4 8.1
230/208 265 230/208 265 230/208 265 230/208 265
253-197 292/239 253-197 292/239 253-197 292-239 253-197 292-239
4.3/4.3 3.5 5.7/5.9 5.1 8.6/9.2 7.6 10.9/10.6 9.7
21.0 21.0 30.0 30.0 42.0 42.0 46.0 46.0
3.5 3.5 4.8 4.8 7.8 7.8 9.5 9.5
1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
1.2 1.2 1.2 1.2 1.2 0.42 1.9 1.8
1/4 1/4 1/4 1/4
0.9 0.85 0.85
23”x23”x32” 23x23x32 23”x23”x32” 23x23x32 23”x23”x47” 23”x23”x47” 23”x23”x47” 23”x23”x47”
142 144 147 149 190 192 205 207
164 166 169 171 216 218 231 233
LOW LOW LOW LOW HIGH HIGH LOW LOW
38 39 39.5 37 54 52.8 65 65
LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH
420 450 420 450 420 450 390 450 420 465 420 465 610 700 610 700
405 425 405 425 405 425 375 425 390 420 390 420 585 670 585 670
385 400 385 400 385 400 350 400 345 380 345 380 560 640 560 640
355 375 355 375 355 375 325 375 300 325 300 325 535 610 535 610
320 350 320 350 320 350 320 350 255 280 255 280 510 580 510 580
60 60 60 60 60 60 60 60
ASHRAE 90.1-2013 Compliant Model
NOTES:
Cooling Standards: 95°F DB/75°F WB OUTDOOR, 80°F DB/67°F WB INDOOR Heating Standards: 47°F DB/43°F WB OUTDOOR, 70°F DB/60°F WB INDOOR Normal Value Wet Coil @ .1” ESP. Rated CFM at Low Speed: VHA09….420 VHA12….420 VHA18….420 VHA24….610
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
2
ULCDTP
UNIT CHASSIS DIMENSIONS
Applicable Models
VHA09K VHA09R VHA12K VHA12R
Outside Wall
Applicable Models
VHA18K VHA18R VHA24K VHA24R
UNIT TOP VIEW DIMENSIONS
control box
3
/8"
8
5
/16"
5
electrical entrance
22 5/16"
3
6
/16"
3
4
/16"
3
7
/16"
3
INSTALLATION OVERVIEW Small chassis
Applicable Models
VHA09K VHA09R VHA12K VHA12R
Louver VPAL2/VPSC2 (Sold separately)
VPAWP1-8 = 5 1/2" - 8" D x 24 1/8" W x 30 3/8" H VPAWP1-14 = 8" - 14" D x 24 1/8" W x 30 3/8" H
Part A Outside Wall Plenum
INSTALLATION OVERVIEW Large chassis
Exterior/ Outside Wall
Filter (14” x 20”)
Part B Inside Wall Plenum
Unit
Applicable Models
VHA18K VHA18R VHA24K VHA24R
Louver VPAL2/VPSC2 (Sold separately)
Part A Outside Wall Plenum
Exterior/ Outside Wall
VPAWP1-8 = 5 1/2" - 8" D x 24 1/8" W x 30 3/8" H VPAWP1-14 = 8" - 14" D x 24 1/8" W x 30 3/8" H
4
Large Chassis Unit (Unit height 47”)
Filter (14” x 20”)
Part B Inside Wall Plenum
Drain Pan required (Sold separately)
TYPICAL UTILITY CLOSET
Chassis shown in closet on optional platform
25" x 20" Filter Field Supplied)
VPRG4/VPRG4R Access Panel and Return Air Filter Grille
VPAWP1-8/1-14 Wall Plenum cut-out dimensions 24
VPRG4 Access Panel cutout dimensions: 27" wide by 55
5
/8" wide x 307/8" high.
3
/4" high.
Thermostat
Wiring
Power
Disconnect
Recommended eld
installed drain pan
Optional Platform
Electrical Connection
Rigid Ductwork
Exterior Wall
Flexible Ductwork
VPAWP1-8/1-14 Wall Plenum
Plenum Divider
3/4" FPT Drain Connection
Chassis installs
3
/8" into Plenum
2
3" Clearance on all three sides minimum for service and installation.
Access Panel with
Return Air Grille VPRG4/VPRG4R
Filter Size: 25” x 20”
Field Supplied
Cutout
Dimensions:
24-5/8" W x 30-7⁄8”H
Same external wall cut out (plenum size) for all models
Same indoor (closet) wall cut out for all models
58"
Cutout
Dimensions:
27" W x 55-3⁄4" H
29"
Hinge on left Side of door
5
Loading...