Friedrich UE08A13B User Manual

Sleeve Dimensions
Friedrich
WSC Sleeve
Fedders A Sleeve
Fedders
B Sleeve*
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
REMOTE
CONTROL
24-HOUR
TIMER
MONEY SAVER
FEATURE
SMART
FAN
ANTIMICROBIAL
FILTER
THRU-THE-WALL AIR CONDITIONERS
cool only | heat pumps | electric heat
Sleeve Dimensions
Friedrich
WSC Sleeve
Fedders A Sleeve
Fedders
B Sleeve*
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
REMOTE
CONTROL
24-HOUR
TIMER
MONEY SAVER
FEATURE
SMART
FAN
ANTIMICROBIAL
FILTER
Perfect for new construction, retrots and remodeling
The Most Energy Efficient Solid-side Air Conditioner
Installs in existing 27” sleeves
COOLING ONLY, HEAT PUMP & ELECTRIC HEAT
• High eciency operation saves on energy costs
• Residential/commercial applications
• Mounts ush with the exterior wall for a neat appearance
• A high eciency replace
• Ideal for thicker wall installa tions, where side ns don’t t
• Easy-to-reach, top mount controls
• Three-speed fan
• Ecient rotary compressor
• Easy-to-clean lter
REMOTE CONTROL FEATURES
• 24 hour programmable timer
• Money Saver® setting saves energy by cycling the fan with the compressor
• Smart Fan auto-adjusts fan speed to maintain desired temperature
• Auto-memory backup
FIVE EnergyStar models
Units are shown installed in WSC sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a bae kit. See BAK accessory under accessories.
Sleeve Dimensions
Friedrich
USC Sleeve
GE Amana
Whirlpool/
Fedders
Frigidaire
Height (inches) 15 17/32 15 5/8 15 5/8 15 3/4 15 7/16
Width (inches) 25 7/8 26 26 26 3/4 25 7/8
Depth (inches) 16 23/32 16 7/8 16 7/8 15 18
REMOTE
CONTROL
12-HOUR
TIMER
MONEY SAVER
FEATURE
THRU-THE-WALL units mount ush with
exterior walls for a sleek appearance, as well as unobstructed window views. (Wallmaster WSC sleeve shown with architectural grille. Uni-t grille has dierent appearance.)
Universal Fit for Easy Replacement Chassis installs into existing 26" sleeves
COOLING ONLY & ELECTRIC HEAT
• Rotary compressors provide quiet, dependable performance
• Six-way air ow control
• Stale air exhaust
HEAT/COOL MODELS feature mechanical controls,
two cooling speeds, two heating speeds, plus one fan-only setting.
COOLING MODELS feature electronic controls
with remote control, Money Saver® setting that saves energy by cycling the fan with the compres­sor and three cooling/three fan-only speeds.
Auto re-start
• Washable/reusable lter
• Seacoast protection
REMOTE CONTROL FEATURES (cool only models)
• 12 hour programmable timer
• Money Saver® setting saves energy by cycling the fan with the compressor
TWO EnergyStar models
Units are shown without USC sleeve (USC sleeves sold and shipped separately)
Model Height Width Depth
Depth
with
Front
Minimum Extension Into Room
Minimum
Extension
Outside
Thru-the-wall Finished Hole
Height Width
WALLMASTER
WSC Sleeve Chassis
16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 3/4" 26 1/2" 21"
UNI-FIT
USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" US Chassis 14 3/8" 24" 20 1/8" 3 3/4"
UE Chassis 14 3/8" 24 5/8" 19 5/8" 3 1/2"
Commercial
and residential
applications
When should you install a solid side sleeve?
SOLID SIDE wall sleeve
allows for installation in thick exterior walls where the installation of room air units with side vents would eect performance and may even void the warranty.
ROOM AIR CONDITIONER Blocked side vents restrict air ow
FRIEDRICH THRU-THE -WALL Solid-side sleeve (no side vents)
Model Height Width Depth
Depth
with
Front
Minimum Extension Into Room
Minimum
Extension
Outside
Thru-the-wall Finished Hole
Height Width
WALLMASTER
WSC Sleeve Chassis
16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 3/4" 26 1/2" 21"
UNI-FIT
USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" US Chassis 14 3/8" 24" 20 1/8" 3 3/4"
UE Chassis 14 3/8" 24 5/8" 19 5/8" 3 1/2"
Exterior Grilles
WSC Sleeve/Standard Grille WSC Sleeve/Optional Architectural Grille, AG
Installation Accessories (WallMaster only)
IMPORTANT:
Operating the air conditioner
with incorrect rear grille or
without Bae Adapter Kit
(on 19 3/4” deep sleeve) will recirculate discharge air and cause compressor overload to trip.
CORRECT Ver tical Louvers
INCORREC T Horizontal Louvers
DK / Drain Kit
Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired.
SB / Sub Base
Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall.
Exterior Grilles
USC Sleeve/Standard Grille USC Sleeve/Replacement Grille*
IDK / Internal Drain Kit
New construction applications where a condensate drain system has been built into the wall interior.
STANDARD GRILLE – Expanded aluminum
For use with USC sleeve. (Ships with USC sleeve).
*REPLACEMENT GRILLE – High-tech plastic
For use on existing sleeves without any grille. (Ships with
chassis).
IMPORTANT NOTE:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a bae adapter should be used.
BAK / Bae Adapter Kit
Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).
16 3/4"
Fedders B
19 3/4”
Sleeve/Chassis Dimensions
IMPORTANT:
• Sleeves are sold and shipped separately to accommodate new construction and replacement requirements
Specications
Model
Cooling
Capacity
BTU/h
Heating
Capacity
BTU/h
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efficiency
Ratio
EER
Moisture Removal Pints/Hr.
Room
Side Air
Circulation
Net
Weight
Lbs.
WALLMASTER
WS08B10A 8000 115 6.8 762 10.5 1.3 245 93
WS10B10A 10000 115 8.7 954 10.5 2.4 245 103
WS14B10A 13500 115 12.0 1415 9.5 3.3 295 112
WS10B30A 10000/10000 230/208 4.6/5.0 1005/996 10.0/10.0 2.1 260 101 WS13B30B 12500/12000 230/208 6.3/6.7 1404/1379 8.9/8.7 3.3 280 109 WS16B30A 15800/15000 230/208 7.8/8.5 1756/1705 9.0/8.8 4.2 290 119 WE10B33C 10000/10000 11000/9100 230/208 4.6/5.0 1005/996 16.0/14.7 3550/2950 10.0/10.0 2.1 260 103 WE13B33C 12500/12000 11000/9100 230/208 6.3/6.7 1404/1379 16.0/14.7 3550/2950 8.9/8.7 3.3 280 111 WE16B33C 15800/15000 11000/9100 230/208 7.8/8.5 1756/1705 16.0/14.7 3550/2950 9.0/8.8 4.2 290 121
WY10B33C 10100/9800 8100/7800 230/208 4.6/4.8 1013/976 3.9/4.0 857/821 10.0/10.0 2.5 230 107 WY13B33C 12500/12100 10400/10000 230/208 6.4/6.8 1389/1352 5.4/5.7 1182/1136 9.0/9.0 3.2 280 116
UNI-FIT
US08B10A 8000 115 7.5 830 9.6 2.2 260 73 US10B10A 9800 115 10.2 1110 8.8 3.2 285 78
US10B30A 10000/9800 230/208 4.7/5.2 1060/1040 9.4 3.2 285 78 US12B10A 11500 115 12.0 1310 8.8 3.8 290 80 US12B30B 11500/11200 230/208 6.0/6.4 1310/1270 8.8 3.8 290 80 US14B30A 13000/12600 230/208 7.0/7.5 1530/1480 8.5 4.0 300 84 UE08A13B 8000 3850 115 7.5 830 10.7 1230 9.6 2.2 260 73 UE10A33B 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4 3.2 285 78
UE12A33B 11500/11200 11200/9200 230/208 6.0/6.4 1310/1270 15.3/14.0 3500/2900 8.8 3.8 290 80
WallMaster
Model Number
Uni-Fit
Model Number
Circuit Rating
Breaker
or T-D Fuse
Plug Face (NEMA#)
Wall
Outlet
Appearance
WS0 8B10A, WS10B10A, WS14B10A
US0 8B10A, UE 08 A13B US10B10A, US12B10A
125V - 15A 5 - 15P
WS10B30A, WS13B30A, WS16B 30A
US10B30A, US12B30B, US14B30A
250V - 15A 6 - 15P
WE10, WE13, WE16 WY10, WY13
UE10A33B, UE12A 33B 250V - 20A 6 - 20 P
EnErgy Star
®
models
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip per formance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP HEATING PERFORMANCE
Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approxi­mately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating per­formance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and termi­nated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/2950 watts.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.
Plug Face/ Circuit Rating
Friedr ich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-15 40 | (800) 541-66 45 | fax (210) 357-4 480 | www.friedr ich.com
TT W-08 Printed in USA
As an EnErgy Star® partner, Friedrich Air Conditioning Co. has determined that the selected EnErgy Star® models (  ) meet the EnErgy Star® guidelines for energy efciency.