• Mounts ush with the exterior
wall for a neat appearance
• A high eciency replacement for 27" sleeves including Fedders A and B*. Sleeve
measures 27" W x 16 3/4" H
• Ideal for thicker wall installations, where side ns don’t t
• Easy-to-reach, top mount
controls
• Three-speed fan
• Ecient rotary compressor
• Easy-to-clean lter
• Auto restart
Solid-side Air Conditioner
Chassis installs into
existing 27” sleeves
DIGITAL CONTROLS fEATuRE
• Fully functional remote control
• 24 hour programmable timer
• Money Saver® setting saves energy by
cycling the fan with the compressor
• Smart Fan auto-adjusts fan speed to
maintain desired temperature
• Auto-memory backup saves setting
should power be interrupted
En E r g y St a r ®
5
models
Units are shown installed in WSC sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a bae kit. See BAK accessory under accessories.
Page 3
REMOTE
CONTROL
12-HOuR
TIMER
MONEY SAVER
fEATuRE
THRu-THE-WALL 26” sleeve
THRU-THE-WALL units mount
ush with exterior walls for a sleek
appearance, as well as unobstructed
window views.
(Wallmaster WSC sleeve shown with
architectural grille. Uni-t grille has
dierent appearance.)
luniversal t
8,000 to 13,000 BTU/h COOLING
EERs up to 9.6
• Rotary compressors
provide quiet, dependable
performance
• Six-way air ow control
• Stale air exhaust
HEAT/COOL MODELS feature mechanical controls,
two cooling speeds, two heating speeds, plus
one fan-only setting.
COOLING MODELS feature electronic controls
with remote control, Money Saver® setting that
saves energy by cycling the fan with the compressor and three cooling/three fan-only speeds.
Operating the air
conditioner with incorrect
rear grille or without Bae
Adapter Kit (on 19 3/4”
deep sleeve) will recirculate
discharge air and cause
compressor overload to trip.
CORRECT Ver tical Louvers
INCORRECT Horizontal Louvers
WSC Sleeve
Standard Grille - Ships
WSC Sleeve
Optional Architectural Grille- AG
with sleeve
Installation Accessories (27” sleeve models only)
DK / Drain Kit
Installed at the back of the unit and allows
for attachment to permanent condensate
disposal system, if disposal is necessary
or desired.
SB / Sub Base
Used as a base for the unit when
it is desired to place the cord and
receptacle within the installation, or
simply as a base for the unit when
mounted low in the wall.
26” Sleeve Exterior Grilles
IDK / Internal Drain Kit
New construction applications where
a condensate drain system has been
built into the wall interior.
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
High-tech plastic for use on existing sleeves without any grille.
BAK / Bae Adapter Kit
Necessary when installing in a sleeve
deeper than 16 3/4" deep, such as
Fedders B sleeve (19 3/4" deep).
IMPORTANT:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a bae
adapter should be used.
USC Sleeve
Standard Grille
Sleeve shown with
Replacement Grille
Sleeve/Chassis Dimensions
IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements
IMPORTANT:
US chassis w/front fully installed into USC sleeve
extends into room 3 3/8”. UE chassis w/front fully
installed into USC sleeve extends into room 2 7/8”.
US= 3
3
/8
”, UE= 2
7
/8
”
Page 5
DIGITAL CONTROLS with REMOTE
Commercial
& Residential
Applications
When should you
install a solid side
sleeve?
SOLID SIDE wall sleeve
allows for installation in
thick exterior walls where
the installation of room air
units with side vents would
eect performance and may
even void the warranty.
ROOM AIR CONDITIONER
Blocked side vents restrict air ow
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can
be installed ush with exterior wall.
WallMaster Heat Pump heating information (shown inred) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip per formance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE
Change-over from heat pump operation to resistance operation on models
indicated is automatic at a preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops
and the electric heat starts, then operates with the fan to maintain indoor
comfort. Below 43°F, the unit remains in electric heat mode. During electric heat
mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7
amps, and 3550/2950 watts.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Plug Face/ Circuit Rating
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
TT W-09 (1-09) Printed in USA
As an En E r g y St a r® partner, Friedrich Air Conditioning Co. has determined that the selected
En E r g y St a r® models ( ) meet the En E r g y St a r® guidelines for energy efciency.