Kühl® Series
CIRCUIT RATING/ BREAKER/POWER CORD
The smartest window air conditioners ever designed.
Kühl SQ/EQ Models
Kühl SS, SM and SL Models
Kühl+ ES, YS, EM, YM, EL and YL Models
SPECIFICATIONS
Indicates ENERGY STA R
®
models
Estimated
Model UPC Cooling Btu Heating Btu Volts Cooling Amps Cooling Watts
®
(Cool Only)
Kühl
SQ06N10C 724587432664 5800 — 115 4.1 472 — — 12.3 12.1 $43 — 1.5 190
SQ08N10D 724587432671 8000 — 115 6.1 656 — — 12.2 12.0 $59 — 1.9 200
SS08N10C 724587432589 8000 — 115 5.8 656 — — 12.2 12.0 $59 — 1.9 255
SS10N10C 724587432640 10000 — 115 7. 2 820 — — 12.2 12.0 $74 — 2.5 300
SS12N10C 724587432688 11900 — 11 5 8.7 975 — — 12.2 12.0 $88 — 3.9 300
SS12N30C 724587432695 12000/11800 — 230/208 4.5/4.9 984/967 — — 12.2/12.2 12.0/12.0 $89 — 3.6 300
Amps
Heating
Heating
Watts EER CEER
Energy
Cost COP
Yearly
Moisture
Removal-
Pints/HR CFM
SS14N10C 724587432701 13600 — 115 10.4 1214 — — 11. 2 10.9 $109 — 4.3 275
SM14N10 724587432442 13700 — 115 9.9 11 2 3 — — 12.2 12.0 $101 — 3.0 360
SM14N30 724587432435 13800/13300 — 230/208 5.0/5.3 1131/1099 — — 12.2/12.1 12.0/12.0 $102 — 3.6 360
SM18N30B 724587432718 20000/20000 — 230/208 9.3/10.2 2092/2041 — — 9.8/9.8 9.8/9.8 $184 — 6.0 425
SM21N30D 724587432725 20500/20000 — 230/208 9.3/10.2 2092/2041 — — 9.8/9.8 9.8/9.8 $188 — 6.0 425
SL24N30C 724587432626 24000/24000 — 230/208 10.2/11.1 2308/2308 — — 10.4/10.4 10.3/10.3 $208 — 7. 0 640
SL28N30C 724587432657 28000/28000 — 230/208 13.1/14.1 2800/2800 — — 10.0/10.0 9.9/9.9 $252 — 8.5 640
SL36N30B 724587429961 36000/35500 — 230/208 17.5/19.2 4000/3944 — — 9.0/9.0 9.0/9.0 $360 — 12.0 725
®
Kühl
+ (Heat Pump)
YS10N10C* 724587432541 10000 8800 115 7. 9 917 9.0 978 10.9 10.8 $83 2.6 2.0 300
YS12N33C 724587432558 12000/12000 11300/11000 230/208 4.9/5.2 1101 / 11 01 5.6/5.9 1257/1213 10.9/10.9 10.8/10.8 $99 2.6/2.7 3.0 375
YM18N34C 724587432732 17500/17200 15200/15200 230/208 7.1/7.6 1606/1578 19.5/17.0 1665/1665 10.9/10.9 10.8/10.8 $144 2.7/2.7 5.4 370
YL24N35C 724587432633 24000/24000 22000/22000 230/208 10.1/11.0 2330/2330 10.7/11.4 2391/2391 10.3/10.3 10.2/10.2 $210 2.6/2.6 7. 0 600
Kühl ® + (Electric Heat)
EQ08N11D 724587432749 8000 4000 115 6.1 656 11. 2 1290 12.2 12.0 $61 — 1. 9 200
ES12N33B 724587430004 12000/12000 10700/8900 230/208 4.9/5.2 1062/1062 16.0/14.7 3500/2900 11.3/11.3 11.2/11.2 $96 — 3.4 325
ES14N33 724587432466 13100/13000 10700/8900 230/208 5.2/5.6 1180/1171 16.0/14.7 3500/2900 11.1/10.9 10.9/10.9 $106 — 4.0 325
EM18N34A 724587432091 20000/20000 13000/10600 230/208 9.3/10.2 2041/2041 19.5/17.0 4200/3500 9.8/9.8 9.8/9.8 $184 — 6.0 425
EM21N34 724587432459 20500/20000 13000/10600 230/208 9.3/10.2 2092/2041 19.5/17.0 4200/3500 9.8/9.8 9.8/9.8 $188 — 6.0 425
EL24N35 724587431612 23500/23200 17300/14300 230/208 11.2/12.0 2500/2468 24.0/22.4 5500/4650 9.4/9.4 9.4/9.4 $225 — 7. 0 750
EL36N35B 724587429954 36000/35500 17300/14300 230/208 17.5/19.2 4000/3944 24.0/22.4 5500/4650 9.0/9.0 9.0/9.0 $360 — 12.0 725
Net Wt.
lbs.
Ship Wt.
lbs. Sleeve
72 85
72 85
99 121
106 128
112 13 4
112 13 4
116 13 8
141 15 4
141 15 4
132 15 3
191 2 12
193 2 14
212 248
109 131
115 13 6
141 15 4 M
197 211
72 85
113 12 8
116 13 8
141 15 4
197 211
213 246
Depth
with Front
15
15
28"
/16
" 29"
/16
" 29"
Inches
21
35 ½
Height
Sleeve
Q
S 15
Q
M 17
L 20
Inches
14
¼"
15
/16
15
/16
3
/16"
Width
Inches
19 ¾"
" 25
" 25
3
/8
"
"
Shell Depth
to Louvers
Inches
8
½"
8
¾"
8
¾"
16
½"
Minimum
Extension
Into Room*
Inches
5
½"
5
¾"
5
¾"
3
5
/8
"
Minimum
Extension
Outside
* Inches
10
¾"
15
16
/16
15
16
/16
15
18
/16
Window Width
INCHES
Minimum** Maximum Height Width
"
"
"
22" 42"
3
27
/8
" 42"
3
27
/8
" 42"
7
29
/8
"
14
16
18
42" 20
In-wall Installation
Finished Hole Inches
Max. D epth
½"
3
/16
"
3
/16
"
3
/8
" 28 ¼"
20"
26
26
8 ½
3
7
/16
"
3
/16
"
7
15
Carton Dimensions
Inches
Height Width Depth
"
3
/8
"
3
/8
"
1
/8
3
18
/4
"
22"25 1/
19
"
29"34 1/
21
"
29"34 1/
1
"
24
/2
"
31 5/
8
"
38
2
"
2
"
2
"
7
/8
"
* Minimum extensions when mounted in a window.
S
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.
Sleeve Dimensions Drawing
COOLING SIZING GUIDE
M
L
Front
S
L
Q
S
M
L
Model
All SQ MODELS. EQO8N11D.
SS0 8N10 C, SS10N10C,
SS12N10C and SS14N10C.
YS10N10 C. SM14N10.
SS12N30C. SM14N30 and
SM18N30B. SM21N30D.
(B)
(C)
SIDE VIEW
Circuit Rating
Breaker or
T-D Fuse
125V - 15A 5 - 15P 6
250V - 15A 6 - 15P 6
Plug
Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
Area to be
conditioned
in sq. ft.
Approximate
Cooling Btu
Required
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1500 24000
1500 - 2000 30000
2000 - 2500 34000
Premium LCD
Remote
Full LCD display shows
MODE, FAN SPEED,
SET TEMPERATURE
and SCHEDULE. Adjust
TEMPERATURE and
FAN SPEEDS, set AUTO
MODE and turn the
SCHEDULE ON/OFF.
KÜHL® FEATURES
• Two, 7-day energy management programs
• Customizable, 7-day schedules (requires KWIFI
accessory, sold separately)
• 24-hour timer
• 4 cooling/4 fan-only speeds on select models
• Auto fan
• Auto-changeover between cooling and heating
modes (Kuhl+ models except EQ08)
• Auto restart
•8-wayairowcontrol
* Option not available on SQ and EQ models
• Control panel lockout (ON/OFF)
• Steel inner wall and extra dense insulation
materials block outdoor noise
• Vibration-isolating design and components
reduce operating noise
• Fresh air intake/stale air exhaust vent*
•Washable,antimicrobialairlter
•Checklterreminder
•Optionalcarbonlterabsorbsodors
•Easylteraccess
• Robust 20 gauge steel cabinet
• Solid-steel blower housing
• Totally-enclosed commercial grade fan motor
• Durable base pan and steel inner walls
• Aluminum end plates resist rust
• Install in a window or thru-the-wall
• Slideout chassis
• Includes heavy duty window installation
hardware (optional accessory on Kühl+ models,
sold separately)
• Rugged hardboard side panels (heavy duty side
curtains on SQ and EQ models)
• Power cord can run either left or right
•Patentedrmgriphandlesforeasierchassisinstall/
removal
• Smart Grid capable
• ENERGY STAR®qualiedmodels
• EntryGard™ anti-intrusion protection secures the
chassis to the sleeve to deter ‘kick-in’ intrusion
• Insect barrier*
• Aluminum rear grille protects the outdoor coil from
debris and vandalism
LIMITED
WARRANTY
All Kühl models
use R-410A
refrigerant.
SL24N30C and SL28N30C.
ES12N33B and ES14N33.
YS12N 33 C.
SL36N30B. EM18N34A and
EM21N34. EL24N35 and
EL36N35B. YM18N34C and
YL24N 35C.
* YS10N10C heat pump operates on 115 volt and IS NOT equipped with supplemental heat . Will not provide heat at temperatures below 40˚F. Friedrich room air conditioners are
designed to operate in outdoor temperatures from 60˚F to 115˚F.
Kühl+ Heat Pump heating information indicates heat pump performanc e. Kühl+ Electric Heat heating information indicates electric heat strip per formance. For Kühl+ Heat Pump
electric heating performance refer to corresponding Kühl+ Electric Heat model.
As an ENERGY STAR
The consumer, through the A HAM Room Air Conditioner Cer tication Program, can be certain that the A HAM Certication Seal accurately states the unit’s c ooling and heating
capacity rating, the amperes and the energy efciency ratio. EER is the unit’s Energy Efciency Ratio; CEER is the unit ’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on an electricity cost of $.12 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subjec t to change without notice.
®
partner, Friedric h Air Conditio ning Co. has determ ined that the selected ENERGY STAR® models m eet the ENERGY STAR® gui d el ine s fo r ene rg y ef cie ncy.
250V - 20A 6 - 20P 6
250V - 30A 6 - 30P 6
Based on normal room insulation, average number of sun exposed
windows and two person occupancy.
1. If heavily shaded, reduce cooling Btus required by 10%
2. If very sunny, increase cooling Btus required by 10%
3. Add 500 Btus per person over 2 people
4. Add 4,000 Btus if the area is a kitchen
FRIEDRICH.COM