• Tangential blower wheel
for fast, powerful and even
air distribution
• Two permanentlylubricated fan motors for
quiet operation
• EERs up to 13.0; COPs up
to 3.6
• 2 heating and cooling fan
speeds and AUTO mode
• Adjustable high/low
temperature range limits
for reduced energy usage
• Internal diagnostic
program
• Constant Fan Mode
provides continuous fan
operation in cooling and
heating modes
• Fits standard PTAC sleeve
without the added cost of
a bafe kit
FreshAire® IAQ Ready
• A full complement
of Indoor Air Quality
Products has been
certied through
installation and testing
to ensure exceptional air
quality is achieved when
FreshAire IAQ accessories
are added.
• Wireless or wired remote
thermostat operation
• Central desk control ready
• Compatible with energy
management systems
• Reversible indoor air
louvers
• Condensate removal
system uses slinger ring
technology to cool the coil
and increase efciency
• Antimicrobial air lters
• Modular design ensures
easy access to key
components
• 2 yr. parts and labor
warranty; 5 yr. limited
warranty. See warranty
document on back page
for full details.
Protects the outdoor coil
against deterioration and
extends the life of the
unit especially in harsh
coastal environments
PP_PTACPRE_2021_3.25.21
THE EXPERTS IN ROOM AIR CONDITIONING
PRODUCT FEATURES
DIGITAL TEMPERATURE
READOUT
ONE-TOUCH
OPERATION
FAN SPEED MODE
CONSTANT FAN MODE
INDIVIDUAL MODE
& FAN CONTROL
BUTTONS
QUIET START/STOP
FAN DEL AY
By digitally monitoring the desired room temperature, the room is controlled more precisely than
conventional systems. The large, easy-to-read LED display can show either the setpoint or actual room
temperature as selected by owner.
When the unit is powered o, the unit can be returned directly to heating or cooling mode by pressing the
‘Heat’ or ‘Cool’ buttons without the confusing power up sequence of some controls. One-touch control
takes the guesswork out of unit control, delivering a more enjoyable experience and eliminating front-desk
calls.
Friedrich PTAC/PTHP units feature two fan speeds and AUTO mode for the user to select from. This
allows the user to properly select the amount of airow for the desired comfort level and also deliver quiet
performance.
Pressing the Constant Fan Mode button will provide continuous fan operation in cooling or heating modes.
The fan speed selection is made by pressing either “High” or “Low” fan speed button
By having separate control buttons and indicators for both fan and mode settings, the Friedrich digital
control eliminates the confusion of previous digital PTACs. The accurate temperature setting provides
greater guest comfort than other systems.
The fan start and stop delays prevent abrupt changes in room acoustics due to the compressor energizing
or stopping immediately. Upon call for cooling or heating, the unit fan will run for ve seconds prior to
energizing the compressor. Also, the fan-o delay allows for “free cooling” by utilizing the already cool
indoor coil to its maximum capacity by running for 30 seconds after the compressor.
REMOTE THERMOSTAT
OPERATION
INTERNAL DIAGNOSTIC
PROGRAM
SERVICE ERROR CODE
STORAGE
ROOM FREEZE
PROTECTION
RANDOM COMPRESSOR
RESTART
Some applications require the use of a wall-mounted thermostat. All new Friedrich PTACs may be
switched from unit control to remote thermostat control easily without the need to order a special model
or accessory kit.
The Friedrich digital PTAC features a self-diagnostic program that can alert maintenance to component
failures or operating problems. The internal diagnostic program saves properties valuable time when
diagnosing operating problems.
All Friedrich PTAC units have self-diagnostic features that will store trouble codes in the case of an event.
Storing the codes allows the property to see the trouble codes at a future time after the condition may
have corrected.
When the PTAC senses that the indoor room temperature has fallen to 40°F, the unit will cycle on the
fan (high) and the electric strip heat to raise the room temperature to 46°F, and then cycle o again. This
feature works regardless of the mode selected and can be turned o. The control will also store the Room
Freeze cycle in the service code memory for retrieval at a later date. This feature ensures that unoccupied
rooms do not reach freezing levels where damage can occur to plumbing and xtures.
Multiple compressors starting at once can often cause electrical overloads and premature unit failure.
The random restart delay eliminates multiple units from starting at once following a power outage or initial
power up. The compressor delay will range from 180 to 240 seconds.
CONDENSATE REMOVAL
SYSTEM
FRESHAIRE® IAQ READY
2
Condenser fan utilizes slinger ring technology to pick up condensate from the base pan and disperse it on
to the condenser coil where it evaporates. This helps to cool the coil and increase the energy eciency
of the unit.
A full complement of Indoor Air Quality Products has been certied through installation and testing
to ensure exceptional air quality is achieved when FreshAir IAQ accessories are added.
PRODUCT FEATURES
ELECTRONIC
TEMPERATURE LIMITING
DIAMONBLUE
ADVANCED CORROSION
PROTECTION
®
DIGITAL DEFROST
THERMOSTAT
INSTANT HEAT MODE
FOR HEAT PUMPS
EVEN HEAT MONITORING
SEPAR ATE HEAT/COOL
FAN CYCLE CONTROL
EMERGENCY
HEAT OVERRIDE
By limiting the operating range, the proper ty can save energy by eliminating “max cool” or “max heat”
situations common with older uncontrolled systems. The new electronic control allows owners to set
operating ranges for both heating and cooling independently of one another.
Diamonblue Advanced Corrosion Protection® protects the outdoor coil from harsh environments.
Standard on all models.
The PD Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the
heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy
and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
Heat pump models will automatically run the electric heater to quickly bring the room up to temperature
when initially energized, then return to heat pump mode. This ensures that the room is brought up to
temperature quickly without the usual delay associated with heat pump units.
The digital control monitors indoor conditions, ensuring room temperature is within 5°F of the setpoint. If
needed, the unit will briey cycle the electric heater to maintain temperature. This feature preserves the
eciency benets of a heat pump while ensuring guest comfort.
Using the “Constant Fan” one may choose between fan cycling or fan continuous mode based on property
preference. (Note: Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode) Fan
continuous mode is used to keep constant airow circulation in the room during all times the unit is ‘ON’. Fan
cycle will conserve energy by only operating the fan while the compressor or electric heater is operating.
The ability to set the fan cycling condition independently between heating and cooling mode will increase
user comfort by allowing the choice of only constantly circulating air in the summer or winter time (unlike
other PTAC brands that only allow one selection).
In the event of a compressor failure in heat pump mode, the compressor may be locked out to provide
heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor
failure, the room temperature can be maintained until the compressor can be serviced.
CENTR AL DESK
CONTROL READY
INDOOR COIL
FROST SENSOR
ULTRAQUIET
AIR SYSTEM
HIGH EFFICIENCY
DUAL MOTOR
ROTARY COMPRESSOR
STAINLESS STEEL
ENDPL ATES
TOP-MOUNTED
ANTIMICROBIAL
AIR FILTERS
All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy
management system. Controlling the unit from a remote location like the front desk can reduce energy
usage and requires no additional accessories on the PTAC unit.
The frost sensor protects the compressor from damage in the event that airow is reduced or low outdoor
temperatures cause the indoor coil to freeze. When the indoor coil reaches 30°F, the compressor is
disabled and the fan continues to operate based on demand. Once the coil temperature returns to 45°F,
the compressor returns to operation.
The PD Series units feature an indoor fan system design that reduces sound levels without lowering
airow or preventing proper air circulation.
The Friedrich PTAC has been engineered so that all functional systems are optimized so that they work
together to deliver the highest possible per formance.
The dual-motor design means that the indoor motor can run at slower speeds which reduces sound
levels indoors.
High eciency rotar y compressors are used on all Friedrich PTACs to maximize durability and
eciency.
Outdoor coil endplates made from stainless steel reduce corrosion on the outdoor coil common with other
coil designs.
All Friedrich PTAC return air lters feature an antimicrobial element that has proven to prevent mold and
bacterial growth in laboratory testing. PXFTA replacement lter kits feature the same antimicrobial agent.
All lters are washable, reusable and easily accessed from the top of the unit without the removal of the
front cover.
FILTERED FRESH
AIR INTAKE
R-410A REFRIGERANT
Friedrich PTAC units are capable of introducing up to 75 CFM of outside air into the conditioned space.
The outdoor air passes through a washable mesh screen to prevent debris from entering the airstream.
Friedrich PTAC units use environmentally-friendly refrigerant.