Friedrich PDE15R5SG, PDH15R5SG, PDH07R3SG, PDH07K3SG, PDH15K5SG Product Profile

...
PRODUCT PROFILE
SG SERIES
PRODUCT PROFILE
Packaged Terminal Air Conditioners
Features
• Tangential blower wheel for fast, powerful and even air distribution
• Two permanently­lubricated fan motors for quiet operation
• EERs up to 13.0; COPs up to 3.6
• 2 heating and cooling fan speeds and AUTO mode
• Adjustable high/low temperature range limits for reduced energy usage
• Internal diagnostic program
• Constant Fan Mode provides continuous fan operation in cooling and heating modes
• Fits standard PTAC sleeve without the added cost of
a bafe kit
• Wireless or wired remote thermostat operation
Central desk control ready
• Compatible with energy management systems
• Reversible indoor air louvers
• Condensate removal system uses slinger ring technology to cool the coil
and increase efciency
Antimicrobial air lters
• Modular design ensures
easy access to key
components
• 2 yr. parts and labor warranty; 5 yr. limited warranty. See warranty
document on back page
for full details.
Protects the outdoor coil against deterioration and extends the life of the unit especially in harsh coastal environments
THE EXPERTS IN ROOM AIR CONDITIONING
PRPRF_SGPTAC_2018 94304200_01
PRODUCT FEATURES
DIGITAL TEMPERATURE READOUT
ONE-TOUCH OPERATION
FAN SPEED MODE
CONSTANT FAN MODE
INDIVIDUAL MODE & FAN CONTROL BUTTONS
QUIET START/STOP FAN DEL AY
By digitally monitoring the desired room temperature, the room is controlled more precisely than con­ventional systems. The large, easy-to-read LED display can show either the set point or actual room temperature as selected by owner.
When the unit is powered off, the unit can be returned directly to heating or cooling mode by pressing the
‘Heat’ or ‘Cool’ buttons without the confusing power up sequence of some controls. One-touch control
takes the guesswork out of unit control, delivering a more enjoyable experience and eliminating front-desk calls.
Friedrich PTAC/PTHP units feature two fan speeds and AUTO mode for the user to select from. This al-
lows the user to properly select the amount of air ow for the desired comfort level and also deliver quiet
performance.
Pressing the Constant Fan Mode button will provide continuous fan operation in cooling or heating modes.
The fan speed selection is made by pressing either "High" or "Low" fan speed button
By having separate control buttons and indicators for both fan and mode settings, the Friedrich digital control eliminates the confusion of previous digital PTACs. The accurate temperature setting provides greater guest comfort than other systems.
The fan start and stop delays prevent abrupt changes in room acoustics due to the compressor energiz-
ing or stopping immediately. Upon call for cooling or heating, the unit fan will run for ve seconds prior to
energizing the compressor. Also, the fan-off delay allows for “free cooling” by utilizing the already cool
indoor coil to its maximum capacity by running for 30 seconds after the compressor.
REMOTE THERMOSTAT OPERATION
INTERNAL DIAGNOSTIC PROGRAM
SERVICE ERROR CODE STORAGE
ROOM FREEZE PROTECTION
RANDOM COMPRESSOR RESTART
Some applications require the use of a wall-mounted thermostat. All new Friedrich PTACs may be switched from unit control to remote thermostat control easily without the need to order a special model
or accessory kit.
The Friedrich digital PTAC features a self-diagnostic program that can alert maintenance to component
failures or operating problems. The internal diagnostic program saves properties valuable time when diagnosing operating problems.
All Friedrich PTAC units have self-diagnostic features that will store trouble codes in the case of an event.
Storing the codes allows the property to see the trouble codes at a future time after the condition may have corrected.
When the PTAC senses that the indoor room temperature has fallen to 40°F, the unit will cycle on the fan (high) and the electric strip heat to raise the room temperature to 46°F, and then cycle off again. This feature works regardless of the mode selected and can be turned off. The control will also store the Room Freeze cycle in the service code memory for retrieval at a later date. This feature ensures that unoccupied
rooms do not reach freezing levels where damage can occur to plumbing and xtures.
Multiple compressors starting at once can often cause electrical overloads and premature unit failure.
The random restart delay eliminates multiple units from starting at once following a power outage or initial
power up. The compressor delay will range from 180 to 240 seconds.
CONDENSATE REMOVAL SYSTEM
2
Condenser fan utilizes slinger ring technology to pick up condensate from the base pan and disperse it on
to the condenser coil where it evaporates. This helps to cool the coil and increase the energy ef ciency
of the unit.
PRODUCT FEATURES
ELECTRONIC
TEMPERATURE LIMITING
DIAMONBLUE
ADVANCED CORROSION
PROTECTION
®
DIGITAL DEFROST
THERMOSTAT
INSTANT HEAT MODE FOR HEAT PUMPS
EVEN HEAT MONITORING
SEPAR ATE HEAT/COOL FAN CYCLE CONTROL
EMERGENCY HEAT OVERRIDE
By limiting the operating range, the proper ty can save energy by eliminating “max cool” or “max heat” situations common with older uncontrolled systems. The new electronic control allows owners to set operating ranges for both heating and cooling independently of one another.
Diamonblue Advanced Corrosion Protection® protects the outdoor coil from harsh environments. Stan­dard on all models.
The PD Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the
heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
Heat pump models will automatically run the electric heater to quickly bring the room up to temperature when initially energized, then return to heat pump mode. This ensures that the room is brought up to temperature quickly without the usual delay associated with heat pump units.
The digital control monitors indoor conditions, ensuring room temperature is within 5° F of the setpoint. If
needed, the unit will briey cycle the electric heater to maintain temperature. This feature preserves the
efciency benets of a heat pump while ensuring guest comfort.
Using the "Constant Fan" one may choose between fan cycling or fan continuous mode based on property preference. (Note: Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode) Fan
continuous mode is used to keep constant airow circulation in the room during all times the unit is ‘ON’. Fan
cycle will conserve energy by only operating the fan while the compressor or electric heater is operating.
The ability to set the fan cycling condition independently between heating and cooling mode will increase
user comfort by allowing the choice of only constantly circulating air in the summer or winter time (unlike
other PTAC brands that only allow one selection).
In the event of a compressor failure in heat pump mode, the compressor may be locked out to provide heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor failure, the room temperature can be maintained until the compressor can be serviced.
CENTR AL DESK CONTROL READY
INDOOR COIL FROST SENSOR
ULTRAQUIET
AIR SYSTEM
HIGH EFFICIENCY
DUAL MOTOR
ROTARY COMPRESSOR
STAINLESS STEEL ENDPL ATES
TOP-MOUNTED ANTIMICROBIAL AIR FILTERS
All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy manage-
ment system. Controlling the unit from a remote location like the front desk can reduce energy usage and requires no additional accessories on the PTAC unit.
The frost sensor protects the compressor from damage in the event that airow is reduced or low outdoor
temperatures cause the indoor coil to freeze. When the indoor coil reaches 30°F, the compressor is disabled and the fan continues to operate based on demand. Once the coil temperature returns to 45°F, the compressor returns to operation.
The PD Series units feature an indoor fan system design that reduces sound levels without lowering
airow or preventing proper air circulation.
The Friedrich PTAC has been engineered so that all functional systems are optimized so that they work
together to deliver the highest possible per formance.
The dual-motor design means that the indoor motor can run at slower speeds which reduces sound
levels indoors.
High efciency rotary compressors are used on all Friedrich PTACs to maximize durability and
ef ci ency.
Outdoor coil endplates made from stainless steel reduce corrosion on the outdoor coil common with other coil designs.
All Friedrich PTAC return air lters feature an antimicrobial element that has proven to prevent mold and
bacterial growth in laboratory testing. PDXFT replacement lter kits feature the same antimicrobial agent.
All lters are washable, reusable and easily accessed from the top of the unit without the removal of the
front cover.
FILTERED FRESH
AIR INTAKE
R-410A REFRIGERANT
Friedrich PTAC units are capable of introducing up to 75 CFM of outside air into the conditioned space.
The outdoor air passes through a washable mesh screen to prevent debris from entering the airstream.
Friedrich PTAC units use environmentally-friendly refrigerant.
3
CHASSIS SPECIFICATIONS
LISTED
PTAC Electric Heat models
PDE07K PDE07R PDE09K PDE09R PDE12K PDE12R PDE15K PDE15R
PERFORMANCE DATA:
Cooling Btu 7200/7000 7200 9400/9200 9400 11800/11600 11800 14500/14200 14500
Cooling Watts 550/535 550 775/760 775 1015/1000 1015 1390/1365 1390
Energy Efciency Ratio, EER 13.0/13.0 13.0 12.1/12.1 12.1 11.6/11.6 11.6 10.4/10.4 10.4
Moisture Removal (pints/hr.) 1.7 1.7 2.1 2.1 2.7 2.7 3.1 3.1
Sensible Heat Ratio 0.86 0.86 0.85 0.85 0.75 0.75 0.67 0.67
ELECTRICAL DATA:
Voltage (1 Phase, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
Current (Amps) 2.7/2.9 2.4 3.7/3.9 3.3 4.9/5.1 4.2 6.2/6.7 5.4
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Compressor LRA 13.0 12.5 19.5 13.5 21.5 19.0 28.9 21.6
Compressor RLA 2.5 2.2 3.5 3.0 4.7 3.9 5.9 5.05
Outdoor Fan Motor, HP 0.080 0.080 0.080 0.080 0.086 0.086 0.086 0.086
AIRFLOW DATA:
Indoor CFM, HIGH 345/315 345 355/325 355 400/390 400 400/390 400
Indoor CFM, LOW 270/255 270 300/275 300 325/310 325 325/310 325
Vent CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D)
Dimensions with Front (H x W x D)
Cut Out Dimensions (H x W x D)
Net Weight (lbs.) 106 107 115 115 119 118 121 121
Shipping Weight (lbs.) 126 127 135 135 139 138 140 140
R-410A Charge (oz.) 23 23 24 24 36 36 36 36
Dimensions with Packaging (inches)
PTHP Heat Pump models
PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R
PERFORMANCE DATA:
Cooling Btu 7200/7000 7200 9400/9200 9400 11800/11600 11800 14500/14200 14500
Cooling Watts 550/535 550 775/760 775 1015/1000 1015 1390/1365 1390
Energy Efcient Ratio, EER 13.0/13.0 13.0 12.1/12.1 12.1 11.6/11.6 11.6 10.4/10.4 10.4
Reverse Heating Btu 6000/5800 6000 8300/8100 8300 10600/10400 10600 13300/13000 13300
Heating Watts 485/470 485 695/675 695 910/895 910 1255/1225 1255
COP 3.6/3.6 3.6 3.5/3.5 3.5 3.4/3.4 3.4 3.1/3.1 3.1
Moisture Removal (pints/hr.) 1.7 1.7 2.1 2.1 2.7 2.7 3.1 3.1
Sensible Heat Ratio 0.86 0.86 0.85 0.85 0.75 0.75 0.67 0.67
ELECTRICAL DATA:
Voltage (1 Phase, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
Current (Amps) 2.7/2.9 2.4 3.7/3.9 3.3 4.9/5.1 4.2 6.2/6.7 5.4
Reverse Heat Amps 2.4/2.6 2.2 3.4/3.2 3.1 4.2/4.7 3.7 6.2/6.7 5.0
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Compressor LRA 13.0 12.5 19.5 13.5 21.5 19.0 28.9 21.6
Compressor RLA 2.5 2.2 3.5 3.0 4.7 3.9 5.9 5.05
Outdoor Fan Motor, HP 0.080 0.080 0.080 0.080 0.086 0.086 0.086 0.086
AIRFLOW DATA:
Indoor CFM, HIGH 345/315 345 355/325 355 400/390 400 400/390 400
Indoor CFM, LOW 270/255 270 300/275 300 325/310 325 325/310 325
Vent CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D)
Dimensions with Front (H x W x D)
Cut Out Dimensions (H x W x D)
Net Weight (lbs.) 113 112 119 119 122 119 124 122
Shipping Weight (lbs.) 133 132 139 139 141 139 144 144
R-410A Charge (oz.) 34 34 34 34 36 36 39 39
Dimensions with Packaging (inches)
Models ending in 'K' are 230/208V, models ending in 'R' are 265V
16” x 42” x 13
16”x 42”x 21 1/2” (all models)
16 1/4”x 42 1/4” (all models)
17 7/8" x 45" x 25 1/4" (all models)
Models ending in 'K' are 230/208V, models ending in 'R' are 265V
16” x 42” x 13
16”x 42”x 21 1/2” (all models)
16 1/4”x 42 1/4” (all models)
17 7/8" x 45" x 25 1/4" (all models)
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
RECEPTACLES AN D FUSE TYPES
Voltage 230V 265V
Amps 15 20 30 15 20 30
Heater Size 2.5 k W 3.5 k W 5.0 k W 2.5 kW 3.5 kW 5.0 kW
Receptacles
NEMA#
4
Receptacle
NEMA# Plug
6-15 R 6-20R 6-30R 7-15R 7-2 0R 7-30R
6-15 P 6-20P 6 -30P 7-15 P 7-2 0P 7-3 0P
3
/4” (all models)
3
/4” (all models)
COOLING & HEATING PERFORMANCE
PDE 230V - Extended Cooling Performance
75 85 95 105 110
72 67 62 72 67 62 72 67 62 72 67 62 72 67 62
8467 8143 7538 8064 7603 7013 7747 7200 6372 7258 6444 5681 6458 5558 4910
0.59 0.8 0.98 0.6 0.83 0.91 0.6 0.86 0.91 0.62 0.91 0.96 0.65 0.97 0.98
11054 10631 9842 10528 9926 9156 10114 9400 8319 9475 8413 7417 8432 7257 6411
0.58 0.79 0.96 0.59 0.82 0.97 0.60 0.85 0.97 0.61 0.90 0.98 0.64 0.96 0.97
13877 13346 12355 13216 12461 11493 12697 11800 10443 11894 10561 9310 10585 9110 8048
0.51 0.70 0.94 0.52 0.72 0.96 0.53 0.75 0.96 0.54 0.79 0.97 0.57 0.84 0.96
17052 16400 15182 16240 15312 14123 15602 14500 12833 14616 12978 11441 13007 11194 9889
0.46 0.62 0.84 0.47 0.65 0.86 0.47 0.67 0.86 0.48 0.71 0.87 0.51 0.75 0.86
PDE07
PDE09
PDE12
PDE15
Btu WATTS 449 456 461 489 494 500 550 550 550 595 594 596 648 648 651 AMPS 2.2 2.2 2.3 2.4 2.4 2.4 2.7 2.7 2.7 2.9 2.9 2.9 3.2 3.2 3.2 SHR Btu WATTS 632 642 649 689 696 704 775 775 775 838 837 839 914 914 918 AMPS 3.1 3.1 3.1 3.3 3.3 3.3 3.7 3.7 3.7 4.0 4.0 4.0 4.3 4.3 4.4 SHR Btu WATTS 828 841 851 902 911 923 1015 1015 1015 1097 1096 1099 1197 1197 1202 AMPS 4.1 4.1 4.1 4.4 4.4 4.4 4.9 4.9 4.9 5.3 5.3 5.3 5.8 5.8 5.8 SHR Btu WATTS 1134 1152 1165 1236 1248 1264 1390 1390 1390 1503 1501 1505 1639 1639 1646 AMPS 5.1 5.2 5.2 5.5 5.5 5.6 6.2 6.2 6.2 6.7 6.7 6.7 7.3 7.3 7.3 SHR
PDH 230V - Extended Cooling Performance
75 85 95 105 110
72 67 62 72 67 62 72 67 62 72 67 62 72 67 62
8467 8143 7538 8064 7603 7013 7747 7200 6372 7258 6444 5681 6458 5558 4910
0.59 0.8 0.98 0.6 0.83 0.91 0.6 0.86 0.91 0.62 0.91 0.96 0.65 0.97 0.98
11054 10631 9842 10528 9926 9156 10114 9400 8319 9475 8413 7417 8432 7257 6411
0.58 0.79 0.96 0.59 0.82 0.97 0.60 0.85 0.97 0.61 0.90 0.98 0.64 0.96 0.97
13877 13346 12355 13216 12461 11493 12697 11800 10443 11894 10561 9310 10585 9110 8048
0.51 0.70 0.94 0.52 0.72 0.96 0.53 0.75 0.96 0.54 0.79 0.97 0.57 0.84 0.96
17052 16400 15182 16240 15312 14123 15602 14500 12833 14616 12978 11441 13007 1119 4 9889
0.46 0.62 0.84 0.47 0.65 0.86 0.47 0.67 0.86 0.48 0.71 0.87 0.51 0.75 0.86
PDH07
PDH09
PDH12
PDH15
Btu WATTS 449 456 461 489 494 500 550 550 550 595 594 596 648 648 651 AMPS 2.2 2.2 2.3 2.4 2.4 2.4 2.7 2.7 2.7 2.9 2.9 2.9 3.2 3.2 3.2 SHR Btu WATTS 632 642 649 689 696 704 775 775 775 AMPS 3.1 3.1 3.1 3.3 3.3 3.3 3.7 3.7 3.7 4.0 4.0 4.0 4.3 4.3 4.4 SHR Btu WATTS 828 841 851 902 911 923 1015 1015 1015 1097 1096 1099 1197 1197 1202 AMPS 4.1 4.1 4.1 4.4 4.4 4.4 4.9 4.9 4.9 5.3 5.3 5.3 5.8 5.8 5.8 SHR Btu WATTS 1134 1152 1165 1236 1248 1264 1390 1390 1390 1503 1501 1505 1639 1639 1646 AMPS 5.1 5.2 5.2 5.5 5.5 5.6 6.2 6.2 6.2 6.7 6.7 6.7 7.3 7.3 7.3 SHR
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
RATING POINT
ARI 310/380
838 837 839 914 914 918
RATING POINT
ARI 310/380
Extended Heating Performance
37 42 47 52 57
5000 5276 6000 6571 7257
2.5 2.6 2.6 2.7 2.8
6153 6557 8300 8860 9473
3.3 3.3 3.4 3.4 3.5
7654 8451 10600 111 72 12120
3.7 3.8 4.2 4.4 4.6
10530 10850 13300 14550 15940
5.6 5.7 6.2 6.5 6.8
PDH07
PDH09
PDH12
PDH15
Btu
WATTS 457 465 485 493 521
AMPS
Btu
WATTS 624 634 695 700 709
AMPS
Btu
WATTS 796 826 910 936 967
AMPS
Btu
WATTS 1155 1170 1255 1330 1389
AMPS
OUTDOOR DRY BULB TEMP. (DEGREES F)