Product Profile
PACKAGED TERMINAL
AIR CONDITIONERS
Features
• Tangential blower wheel for
fast, powerful and even air
distribution
• Two permanently-lubricated
fan motors for quiet
operation
• EERs up to 12.2; COPs up
to 3.4
• 3 heating and cooling fan
speeds
• Separate thermostat
settings (limiting) for
cooling and heating modes
allow for improved comfort
• Internal diagnostic program
• Wireless or wired remote
thermostat operation
• Desk control ready
• Compatible with energy
management systems
• Reversible indoor air
louvers
• Condensate removal
system uses slinger ring
technology to cool the coil
and increase efciency
• Antimicrobial air lters
• Modular design ensures
easy access to key
components
• Fits standard PTAC sleeve
without added cost of a
bafe kit
• 2-yr. parts and labor
warranty; 5-yr. limited
warranty (see warranty
document on back page for
full details)
Protects the outdoor coil against
deterioration and extends the
life of the unit especially in
harsh coastal environments.
PTAC_Product_Prole_2014

Product Features
Product Features
DIGITAL TEMPERATURE
READOUT
ONE-TOUCH
OPERATION
INDIVIDUAL MODE
& FAN CONTROL
BUTTONS
QUIET START/STOP
FAN DEL AY
REMOTE THERMOSTAT
OPERATION
INTERNAL DIAGNOSTIC
PROGRAM
SERVICE ERROR CODE
STORAGE
By digitally monitoring the desired room temperature, the room is controlled more precisely than conventional systems. The large, easy-to-read LED display can show either the set point or actual room
temperature as selected by owner.
When the unit is powered off, the unit can be returned directly to heating or cooling mode by pressing the
‘Heat’ or ‘Cool’ buttons without the confusing power up sequence of some controls. One-touch control
takes the guesswork out of unit control, delivering a more enjoyable experience and eliminating front-desk
calls.
By having separate control buttons and indicators for both fan and mode settings, the Friedrich digital
control eliminates the confusion of previous digital PTACs. The accurate temperature setting provides
greater guest comfort than other systems.
The fan start and stop delays prevent abrupt changes in room acoustics due to the compressor energiz-
ing or stopping immediately. Upon call for cooling or heating, the unit fan will run for ve seconds prior to
energizing the compressor. Also, the fan-off delay allows for “free cooling” by utilizing the already cool
indoor coil to its maximum capacity by running for 30 seconds after the compressor.
Some applications require the use of a wall-mounted thermostat. All new Friedrich PTACs may be
switched from unit control to remote thermostat control easily without the need to order a special model
or accessory kit.
The Friedrich digital PTAC features a self-diagnostic program that can alert maintenance to component
failures or operating problems. The internal diagnostic program saves properties valuable time when
diagnosing running problems.
All Friedrich PTAC units have self-diagnostic features that will store trouble codes in the case of an event.
Storing the codes allows the property to see the trouble codes at a future time after the condition may
have corrected.
DIAMONBLUE™
TECHNOLOGY
DIGITAL DEFROST
THERMOSTAT
INSTA NT HEAT
HEAT PUMP MODE
EVEN HEAT MONITORING
SEPARATE HE AT/COOL
FAN CYCLE
CONTROL
EMERGENCY
HEAT OVERRIDE
DESK CONTROL
READY
INDOOR COIL
FROST SENSOR
ULTRAQUIET
AIR SYSTEM
Diamonblue anticorrosive coating protects the outdoor coil from harsh environments. Standard on all
models.
The PD Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the
heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy
and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
Heat pump models will automatically run the electric heater to quickly bring the room up to temperature
when initially energized, then return to heat pump mode. This ensures that the room is brought up to
temperature quickly without the usual delay associated with heat pump units.
The digital control monitors indoor conditions, ensuring room temperature is within 5° F of the setpoint. If
needed, the unit will briey cycle the electric heater to maintain temperature. This feature preserves the
efciency benets of a heat pump while ensuring guest comfort.
The owner may choose between fan cycling or fan continuous mode based on property preference. (Note:
Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode) Fan continuous mode is
used to keep constant airow circulation in the room during all times the unit is ‘ON’. Fan cycle will conserve
energy by only operating the fan while the compressor or electric heater is operating.
fan cycling condition independently between heating and cooling mode will increase user comfort by
allowing the choice of only constantly circulating air in the summer or winter time (unlike other PTAC
brands that only allow one selection).
In the event of a compressor failure in heat pump mode, the compressor may be locked out to provide
heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor
failure, the room temperature can be maintained until the compressor can be serviced.
All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy manage-
ment system. Controlling the unit from a remote location like the front desk can reduce energy usage and
requires no additional accessories on the PTAC unit.
The frost sensor protects the compressor from damage in the event that airow is reduced or low outdoor
temperatures cause the indoor coil to freeze. When the indoor coil reaches 30°F, the compressor is
disabled and the fan continues to operate based on demand. Once the coil temperature returns to 45°F,
the compressor returns to operation.
The PD- series units feature an indoor fan system design that reduces sound levels without lowering
airow or preventing proper air circulation.
The ability to set the
ELECTRONIC
TEMPERATURE
LIMITING
ROOM FREEZE
PROTECTION
RANDOM COMPRESSOR
RESTART
CONDENSATE REMOVAL
SYSTEM
By limiting the operating range, the property can save energy by eliminating “max cool” or “max heat” situations common with older uncontrolled systems. The new electronic control allows owners to set operating ranges for both heating and cooling independently of one another.
When the PTAC senses that the indoor room temperature has fallen to 40°F, the unit will cycle on the
fan (high) and the electric strip heat to raise the room temperature to 46
feature works regardless of the mode selected and can be turned off. The control will also store the Room
Freeze cycle in the service code memory for retrieval at a later date. This feature ensures that unoccupied
rooms do not reach freezing levels where damage can occur to plumbing and xtures.
Multiple compressors star ting at once can often cause electrical overloads and premature unit failure.
The random restart delay eliminates multiple units from starting at once following a power outage or initial
power up. The compressor delay will range from 180 to 240 seconds.
Condenser fan utilizes slinger ring technology to pick up condens
on to the cond enser coil wh ere it evapo rates. This h elps t o co ol t he c oil and increase the energy ef ciency
of the unit.
°
F, and then cycle of f again. This
ate from the base pan and disperse it
HIGH EFFICIENCY
DUAL MOTOR
ROTARY COMPRESSOR
STAINLESS STEEL
ENDPLATES
TOP-MOUNTED
ANTIMICROBIAL
AIR FILTERS
FILTERED FRESH
AIR INTAKE
R-410A REFRIGERANT
The Friedrich PTAC has been engineered so that all functional systems are optimized so that they work
together to deliver the highest possible performance.
The dual-motor design means that the indoor motor can run at slower speeds which reduces sound
levels indoors.
High efciency rotary compressors are used on all Friedrich PTACs to maximize durability and ef ci enc y.
Outdoor coil endplates made from stainless steel reduce corrosion on the outdoor coil common with other
coil designs.
All Friedrich PTAC return air lters feature an antimicrobial element that has proven to prevent mold and
bacterial growth in laboratory testing. PDXFT replacement lter kits feature the same antimicrobial agent.
All lters are washable, reusable and easily accessed from the top of the unit without the removal of the
front cover.
Friedrich PTAC units are capable of introducing up to 75 CFM of outside air into the conditioned space.
The outdoor air passes through a washable mesh screen to prevent debris from entering the airstream.
Friedrich PTAC units use environmentally-friendly refrigerant.
32

Chassis Specifications Cooling & Heating Performance
PDE Series
PERFORMANCE DATA:
COOLING Btu 7700/7600 7700 9000/8800 9000 12000/11800 12000 15000/14600 15000
POWER (WATTS) 640/620 640 800/770 800 1120/1120 1120 1530/1510 1530
EER 12.0/12.2 12.0 11.3/11.4 11.3 10.7/10.5 10.7 9.8/9.7 9.8
DEHUMIDIFICATION (pints/hr) 1.7 1.7 2.2 2.2 2.7 2.7 3.2 3.2
SENSIBLE HEAT RATIO 0.84 0.84 0.81 0.81 0.67 0.67 0.65 0.65
ELECTRICAL DATA:
VOLTAGE (1 PHASE, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
VOLT RANGE 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
CURRENT (AMPS) 2.8/3.0 2.4 3.7/3.9 3.7 5.1/5.3 4.8 6.7/7.5 5.9
POWER FACTOR 0.97 0.99 0.99 0.99 0.99 0.99 0.99 0.99
Compressor LRA 19.0 12.0 17.0 18.0 27.0 23.0 32.6 27.8
Compressor RLA 2.8 2.4 3.7 2.9 5.0 4.3 6.6 5.6
Fan motor horsepower 0.024 0.024 0.029 0.029 0.031 0.031 0.031 0.031
AIRFLOW DATA:
INDOOR CFM, HIGH 345/315 345 360/345 360 360/350 360 385/375 385
INDOOR CFM, MED 320/290 320 330/305 330 330/310 330 360/330 360
INDOOR CFM, LOW 295/265 295 300/270 300 310/280 310 320/290 320
VENT CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
DIMENSIONS (H x W x D) 16 x 42 x 13 3/4 (all models)
NET WEIGHT (lbs.) 106 106 111 111 116 116 119 119
SHIPPING WEIGHT (lbs.) 126 126 131 131 136 136 139 139
R-410A CHARGE (oz) 23.63 24.69 33.51 33.51 35.27 35.98 38.10 40.21
Dim.s w/ Pkg. (inches) 19 3/4 x 23 x 43 1/2 (all models)
PDE07K PDE07R PDE09K PDE09R PDE12K PDE12R PDE15K PDE15R
PDH Series
PERFORMANCE DATA:
COOLING Btu 7700/7600 7700 9000/8800 9000 12000/11800 12000 14500/14200 14500
POWER (WATTS) cool 640/620 640 800/770 800 1120/1120 1120 1480/1460 1480
EER 12.0/12.2 12.0 11.3/11.4 11.3 10.7/10.5 10.7 9.8/9.7 9.8
REVERSE HEATING Btu 6300/6100 6300 8100/7900 8100 10700/10500 10700 13300/13000 13300
POWER (WATTS) HEAT 540/530 540 720/770 720 1010/990 1010 1300/1270 1300
COP 3.4/3.4 3.4 3.3/3.3 3.3 3.1/3.1 3.1 3.0/3.0 3.0
DEHUMIDIFICATION (pints/hr) 1.7 1.7 2.2 2.2 2.7 2.7 3.2 3.2
SENSIBLE HEAT RATIO 0.84 0.84 0.81 0.81 0.67 0.67 0.65 0.65
ELECTRICAL DATA:
VOLTAGE (1 PHASE, 60 Hz) 230/208 265 230/208 265 230/208 265 230/208 265
VOLT RANGE 253-187 292-239 253-187 292-239 253-187 292-239 253-187 292-239
CURRENT (AMPS) 2.8/3.0 2.4 3.7/3.9 3.7 5.1/5.3 4.8 6.7/7.5 5.7
REVERSE HEAT. Amps 2.4/2.5 2.1 3.4/3.8 3.4 4.5/4.7 4.5 5.8/6.2 5.0
POWER FACTOR 0.97 0.99 0.99 0.99 0.99 0.99 0.98 0.98
Compressor LRA 19.0 12.0 18.5 19.0 27.0 23.0 36.0 26.0
Compressor RLA 2.8 2.4 3.6 3.2 5.0 4.3 6.6 5.3
Fan motor horsepower 0.024 0.024 0.029 0.029 0.031 0.031 0.031 0.031
AIRFLOW DATA:
INDOOR CFM, HIGH 345/315 345 360/345 360 360/350 360 420/390 385
INDOOR CFM, MED 320/290 320 330/305 330 330/310 330 410/380 360
INDOOR CFM, LOW 295/265 295 300/270 300 310/280 310 380/350 320
VENT CFM 75 75 75 75 75 75 75 75
PHYSICAL DATA:
DIMENSIONS (H x W x D) 16 x 42 x 13 3/4 (all models)
NET WEIGHT (lbs.) 108 108 113 113 118 118 121 121
SHIPPING WEIGHT (lbs.) 128 128 133 133 138 138 141
R-410A CHARGE (oz) 23.63 24.69 33.51 35.27 35.27 35.98 39.86 36.33
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
Voltage 230V 265V
Amps 15 20 30 15 20 30
Heater Size 0, 2.0 kW 3.0 kW 5.0 kW 2.0 kW 3.0 kW 5.0 kW
Receptacles
PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R
141
RECEP TACLES AND FUSE TY PES
PDE 230V - Extended Cooling Performance
75 85 95 105 110
72 67 62 72 67 62 72 67 62 72 67 62 72 67 62
PDE07
PDE09
PDE12
PDE15
Btu 9055 8709 8062 8624 8131 7500 8285 7700 6815 7762 6892 6075 6907 5944 5251
WATTS 522 531 536 569 575 582 640 640 640 692 691 693 755 755 758
AMPS 2.3 2.3 2.4 2.5 2.5 2.5 2.8 2.86 2.8 3.0 3.0 3.0 3.3 3.3 3.3
SHR 0.53 0.72 0.96 0.54 0.74 0.98 0.54 0.77 0.99 0.55 0.81 0.99 0.58 0.87 0.99
Btu 10584 10179 9423 10080 9504 8766 9684 9000 7965 9072 8055 7101 8073 6948 6138
WATTS 653 663 670 711 718 727 800 800 800 865 864 866 943 943 947
AMPS 3.1 3.1 3.1 3.3 3.3 3.3 3.7 3.7 3.7 4.0 4.0 4.0 4.3 4.3 4.4
SHR 0.49 0.66 0.89 0.50 0.69 0.91 0.50 0.71 0.91 0.51 0.75 0.92 0.54 0.80 0.91
Btu 14112 13572 12564 13440 12672 11688 12912 12000 10620 12096 10740 9468 10764 9264 8184
WATTS 914 928 939 996 1006 1018 1120 1120 1120 1211 1210 1213 1320 1320 1326
AMPS 4.2 4.2 4.3 4.5 4.6 4.6 5.1 5.1 5.1 5.5 5.5 5.5 6.0 6.0 6.0
SHR 0.49 0.66 0.89 0.50 0.69 0.91 0.50 0.71 0.91 0.51 0.75 0.92 0.54 0.80 0.91
Btu 17640 16965 15705 16800 15840 14610 16140 15000 13275 15120 13425 11835 13455 11580 10230
WATTS 1248 1268 1282 1360 1374 1391 1530 1530 1530 1654 1652 1657 1804 1804 1812
AMPS 5.5 5.6 5.6 6.0 6.0 6.0 6.7 6.7 6.7 7.2 7.2 7.2 7.9 7.9 7.9
SHR 0.47 0.63 0.85 0.48 0.66 0.87 0.48 0.68 0.87 0.49 0.72 0.88 0.51 0.77 0.87
PDH 230V - Extended Cooling Performance
75 85 95 105 110
72 67 62 72 67 62 72 67 62 72 67 62 72 67 62
PDH07
PDH09
PDH12
PDH15
Btu 9055 8709 8062 8624 8131 7500 8285 7700 6815 7762 6892 6075 6907 5944 5251
WATTS 522 531 536 569 575 582 640 640 640 692 691 693 755 755 758
AMPS 2.3 2.3 2.4 2.5 2.5 2.5 2.8 2.8 2.8 .03 3.0 3.0 3.3 3.3 3.3
SHR 0.53 0.72 0.96 0.54 0.74 0.98 0.54 0.77 0.99 0.55 0.81 0.99 0.58 0.87 0.99
Btu 10584 10179 9423 10080 9504 8766 9684 9000 7965 9072 8055 7101 8073 6948 6138
WATTS 653 663 670 711 718 727 800 800 800
AMPS 3.1 3.1 3.1 3.3 3.3 3.3 3.7 3.7 3.7 4.0 4.0 4.0 4.3 4.3 4.4
SHR 0.49 0.66 0.89 0.50 0.69 0.91 0.50 0.71 0.91 0.51 0.75 0.92 0.54 0.8 0.91
Btu 14112 13572 12564 13440 12672 11688 12912 12000 10620 12096 10740 9468 10764 9264 8184
WATTS 914 928 939 996 1006 1018 1120 1120 1120 1211 1210 1213 1320 1320 1326
AMPS 4.2 4.2 4.3 4.5 4.6 4.6 5.1 5.1 5.1 5.5 5.5 5.5 6.0 6.0 6.0
SHR 0.49 0.66 0.89 0.50 0.69 0.91 0.50 0.71 0.91 0.51 0.75 0.92 0.54 0.80 0.91
Btu 17052 16400 15182 16240 15312 14123 15602 14500 12833 14616 12978 11441 13007 111 94 9889
WATTS 1208 1227 1240 1316 1329 1345 1480 1480 1480 1600 1598 1603 1745 1745 1752
AMPS 5.4 5.5 5.5 5.9 5.9 5.9 6.5 6.6 6.6 7.1 7.1 7.1 7.7 7.7 7.7
SHR 0.48 0.65 0.88 0.49 0.68 0.89 0.49 0.70 0.90 0.50 0.74 0.90 0.53 0.79 0.90
Extended Heating Performance
37 42 47 52 57
PDH07
PDH09
PDH12
PDH15
Btu 5250 5540 6300 6900 7620
WATTS 509 518 540 549 580
AMPS 2.3 2.4 2.4 2.5 2.6
Btu 6005 6399 8100 8647 9245
WATTS 647 656 720 725 735
AMPS 3.3 3.3 3.4 3.4 3.5
Btu 7726 8531 10700 11278 12234
WATTS 883 917 1010 1039 1073
AMPS 4 4.1 4.5 4.7 4.9
Btu 10530 10850 13300 14550 15940
WATTS 1197 1212 1300 1377 1439
AMPS 5.3 5.4 5.8 6.1 6.3
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
RATING POINT
ARI 310/380
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
865 864 866 943 943 947
RATING POINT
ARI 310/380
OUTDOOR DRY BULB TEMP. (DEGREES F)
RATING POINT
ARI 310/380
NEMA#
Receptacle
NEMA#
Plug
6-15R 6-20R 6-30R 7-15 R 7-20R 7-30R
6-15P 6-20P 6-30P 7-15P 7-20P 7-30P
54