Friedrich MC18Y3JM, MC12Y3JM Brochure

PRELIMINARY
DUCTLESS
SPLIT SYSTEMS
ALL NEW LINE
FOR 2014
THE EXPERTS IN ROOM AIR CONDITIONING
NEW, High Efficiency
Line of Ductless Systems
Three indoor unit types.
R
E
I
O
P
U
S
R
25.0 SEER
E
F
F
I
Y
C
N
C
E
I
efciencies
ever.
Up to 25.0 SEER
Protects the outdoor coil against deterioration and extends the life of the unit especially in harsh coastal environments.
WALL-MOUNTED
Cool only and heat pump models
All of the advantages of ductless systems and Friedrich quality.
ENERGY STAR® qualified models
All Friedrich ductless models exceed the federal 13.0 SEER requirements. And 60% of our models have ratings ranging from 19.0 to 25.0 SEER. Nine models are ENERGY STAR up to 14.0.
®
qualied with EERs
Inverter variable capacity advantages
Inverter technology allows each system
to adjust capacity and cooling output to provide only the amount of cooling needed at a given time. For example,
an 18000 Btu system will operate even more efciently at 15500 Btu or less if
that's all that’s needed, reducing energy consumption and improving comfort.
Ultra quiet cross-flow fan
The cross-ow design of the indoor fan creates an ultra quiet, yet powerful air ow into the room.
Optimized airflow
The indoor unit's 4-way air swing quickly
disperses cool air to all four corners of the room to provide comfort throughout
the room within a few minutes. The
'Air Burst' feature moves air at an even higher speed for rapid cooling.
Low vibration, twin rotary compressors
Friedrich's twin rotary compressors
have a unique design that reduces vibration for reduced sound levels outdoors.
Zero duct loss
The DOE reports that ducted systems lose an average of 25-40% in
performance due to leaks, cracks or disconnections in ductwork. No ductwork means that ductless
systems do not experience duct loss, saving energy and money.
Zone cooling flexibility
Independently condition up to (4) separate zones using only a single outdoor unit. Achieve the ultimate in comfort and energy control by cooling or heating only the zones that are in use. And, because each zone is independent of the others, comfort settings can vary.
No dirty air ducts*
Now there’s no need to clean dirty air
ducts that can harbor dust, germs and
allergens that are eventually blown into your home or ofce.
CEILING CASSETTE
Heat pumps
CONCEALED DUCT
Heat pumps
Inverter technology lets you reach the desired temperature faster, maintain temperature and humidity levels more accurately, and reduce energy costs.
Inverter technology varies the compressor, the outdoor and the indoor fan speeds, eliminating constant
compressor start-ups/shut-downs that
traditional systems require to maintain the set temperature.
This is especially beneficial in multizone
systems where room temperature set
points vary and some indoor units may be turned off in unoccupied rooms.
Each system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time.
The result is optimal comfort with low
energy costs.
The Advantages of Friedrich Inverter Systems
TRADITIONAL SYSTEM INVERTER SYSTEM
At initial star t up, fixed capacity
system slowly reaches the set
temperature.
Complete shutdown once set
temperature is achieved.
Temperature within the space
rises until 2nd system start up.
System works at full capacity to
again reach set temperature.
System cycles on and off continually to maintain the set temperature.
At initial start up, utilizes
variable capacity to quickly
reach the set temperature.
Reduces capacity as set temperature is achieved.
Variable capacity maintains
set temperature keeping space comfortable with reduced
energy consumption.
*Ductless wall-mounted and ceiling cassette models
2
3
70
°
72
°
74
°
OFF
Attractive and high efficiency options for cooling and heating residential and light commercial spaces.
131
MULTIZONE
COMBINATIONS
Wall-mounted models mount
high on the wall.
The attractive,
neutral nish blends well with
just about any decor.
Indoor units can be used individually or as part of a multizone system to condition multiple spaces or a large area.
Residential Applications
• Room additions/renovations
• Homes without ductwork
• Bedrooms and family rooms
• Garage workshops
• Sunrooms
• Guest quarters
• Wine cellars
Commercial Applications
• Hotels and other lodging
• Computer rooms/server rooms
• Restaurant kitchen and prep areas
• Ofces in warehouse spaces
• Storage facilities
• Buildings where security concerns
prevent the use
of window units
• Internal areas without exterior wall access
Zone Cooling and Heating
Occupants have the ability to set the temperature to their preferred comfort level. And, you can turn off units in unoccupied rooms.
That’s the beauty– and efciency of
a Friedrich multizone system.
Enjoy the exibility
to mix and match
wall-mounted,
ceiling cassette and concealed duct
systems to t your
application.
4
5
Features you'll find with Friedrich Ductless Systems:
EASE OF INSTALLATION
Wall-mounted
System Type
Installation Wall Wall Ceiling Ceiling Ceiling Ceiling
Cool only Y N N N N N
Heat pump Y Y Y Y Y Y
115 volt models Y N N N N N
Inverter compressor Y Y Y Y Y Y
SEER Up to 25.0 Up to 21.7 Up to 19 Up to 16.5 Up to 17.6 Up to 16.5
Auto changeover Y N Y N Y N
Low ambient operation* Y Y Y Y Y Y
Programmable timer 24- h r. 24- h r. 24 -hr. 24-hr. 2 4 - h r. N
Remote control Y Y Y Y N N
Wall controller option Y Y Y Y Y Y
Auto restart when power is
interrupted
Continuous ‘Air Sweep” Y Y Y Y N N
Washable, antimicrobial air filters Y Y Y Y Y Y
Single Zone
Y Y Y Y Y Y
Wall-mounted
Multizone
Cassette
Single Zone
Cassette
Multizone
Concealed Duct
Single Zone
Concealed Duct
Multizone
New ductless line with convenient installation features that will get your ductless running in no time.
UNIQUE MOUNTING BRACKET
A SET OF
16 INCH ON CENTER HOLES
16" on Center
The hanging bracket comes with a set of holes that are placed 16” apart from each other to help you attach the bracket securely to "16 on center" wall studs.
Level-Line Ledges
Incorporated “Level-Line Ledges” ensure a straight wall mount and frees both hands for
an easy single-person installation.
Tape Measure Assist
The integrated “blade grip” securely keeps measuring tape in place. The ”blade grip” gives you a helping hand when installing the bracket to the wall.
Auto shut flaps when unit is off Y Y Y Y N N
Louver Position (Fan/Cool/Heat) 6 / 6 / 6 6 / 6 / 6 4 / 5 / 4 4 / 5 / 4 N N
Powerful airflow for faster heating and cooling.
Optimum air flow
Air is directed downward in heating mode and angled upward during cooling mode so the
room feels more comfortable, faster.
Large fans
Powerful fans move the air across the room­up to 39 feet away. That means faster cooling
and heating and you feel comfortable sooner
no matter where you are in the room.
Wall Standoff Bracket
The clip keeps sufcient space between the unit and the wall creating more room for installation.
Spacious Tubing Area
Ample space was created to facilitate tubing
installation and placement.
Low Installation Access Panel
By lowering the access panel to eye-level we
have created a hassle-free access to electrical connections.
Secure Grip Screws
"Grip Screws" rmly secure wall-mounted unit to wall bracket providing a stable setup.
6
7
Single Zone
PRELIMINARY SPECIFICATIONS
WALL-MOUNTED COOL ONLY
9000-24000 Btu. Cool only models with features for convenient operation,
care-free comfort and years of dependability.
Features
• Inverter technology (variable speed compressor)
• High efciency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dry indoor coil
• Cooling/Heating/Fan mode
• Surge cool
• Natural air ow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
• Auto restart
• Built-in low ambient standard, down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• Condensate sensor connection
• Multiple ease of installation features (see p.7)
MW09C1J, MW12C1J MW18C3J, MW24C3J
MR09C1J, MR12C1J MR18C3J MR24C3J
PERFORMANCE RATINGS Single Wall Mounted - Cool Inv
9k 12k 18k 24k SYSTEM MODEL NO. M09CJ M12CJ M18CJ M24CJ INDOOR MODEL MW09C1J MW12C1J MW18C3J MW24C3J OUTDOOR MODEL MR09C1J MR12C1J MR18C3J MR24C3J SPECIFICATIONS CAPACITY COOLING (RATED) Btu 9,000 11,200 17,000 22,000 CAPACITY COOLING (MIN~MAX) Btu 3,070~12,120 3,070~13,660 3,070~20,470 3,070~26,270 CAPACITY HEATING (RATED) Btu N/A N/A N/A N/A CAPACITY HEATING (MIN~MAX) Btu N/A N/A N/A N/A COOLING AMPS 6 8.4 7 8.7 HEATING AMPS N/A N/A N/A N/A SENSIBLE HEAT RATIO .89 .83 .79 .81 SEER 21.5 21.5 18.0 20.0 EER 13.3 12.5 12.0 10.8 HSPF N/A N/A N/A N/A ENERGY STAR YES(Most Efcient) YES(Most Efcient) YES No MOISTURE REMOVAL Pts/h 2.6 3.0 5.3 6.0 AIRFLOW (QUIET, LOW, MED, HIGH) CFM 124/212/272/335 124/212/272/335 300/399/509/622 300/424/629/742 SOUND RATING - INDOOR dB-A 19 / 24 / 33 / 38 19 / 24 / 33 / 39 29 / 35 / 40 / 45 29 / 35 / 40 / 46 SOUND RATING - OUTDOOR dB-A 45 45 53 54 OPERATING RANGE (COOLING)(WIND BAFFLE) °F 14.0(0)~118.4 14.0(0)~118.4 14.0(0)~118.4 14.0(0)~118.4 OPERATING RANGE (HEATING) °F N/A N/A N/A N/A EST. YEARLY OPERATING COST $ 61 81 127 183 ELECTRICAL DATA POWER SOURCE 115-60-1 115-60-1 230/208-60-1 230/208-60-1 MINIMUM AMPACITY A 10 10 19 19 COOLING WATTS W 677 896 1416 2037 MAX. TD FUSE/BREAKER A 15 15 25 25 POWER AND COMMUNICATION CABLE REFRIGERATION SYSTEM REFRIGERANT R410A R410A R410A R410A COMPRESSOR TYPE Inverter Inverter Inverter Inverter CONNECTIONS Flare Flare Flare Flare LIQUID LINE O.D. in 1/4 1/4 1/4 3/8 SUCTION LINE O.D. in 3/8 3/8 1/2 5/8 FACTORY PRECHARGE ft 35.5 35.3 47.6 63.5 MAX. LINE LENGTH ft 66’ 66’ 66’ 98’ MAX. HEIGHT DIFFERENCE ft 33’ 33’ 33’ 49’ DIMENSIONS & WEIGHT INDOOR UNIT W X H X D in NET WEIGHT lbs 23 23 31 32 SHIPPING WEIGHT lbs 27 27 35 37 OUTDOOR UNIT W X H X D in NET WEIGHT lbs 75 75 108 122 SHIPPING WEIGHT lbs 79 79 115 130 TOTAL NET WEIGHT lbs 97 97 139 154 TOTAL SHIPPING WEIGHT lbs 106 106 150 167
NOTE: All R410 models have 1/2" UNF 20 thread per inch charging and vacuuming ports. An adapter must be used for 1/4" gauges. Adapter part number 67270018 is available through Friedrich parts distributors.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
No. x AWG
30-5/16x 21-5/16x 11-5/16 30-5/16x21-5/16x11-5/16 34-5/16x25-7/8x12-5/8 34-5/16 x31-1/2 x12-5/8
4 x 18 4 x 18 4 x 18 4 x 18
35-1/4x 11-1/4x 8-5/16 35-1/4x 11-1/4x 8-5/16 40-5/8x 12-7/8x 9-5/8 40-5/8x 12-7/8x 9-5/8
8
9
Single Zone
PRELIMINARY SPECIFICATIONS
25.0 SEER WALL-MOUNTED HEAT PUMP
12000 Btu. Our most efcient unit ever! Features for comfort and convenience year 'round. In heating mode, unit efciently heats by using approximately 1/4 of the
energy required by electric heat.
Features
• Inverter technology (variable speed compressor)
• High efciency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dry indoor coil
• Surge cool/heat
• Natural air ow
• Ultra quiet operation
• Sleep mode
• Auto restart
• Auto changeover
• BLDC Motor
• Low ambient operation down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• ENERGY STAR® qualied model
• Hidden display (only visible during operation)
• Multiple ease of installation features (see p.7)
MWH12Y3J
25.0 SEER
R
E
I
O
P
U
S
E
F
F
R
Y
C
N
I
C
E
I
MRH12YCJ
PERFORMANCE RATINGS Single Wall Mounted - H/P Inv (High SEER)
12k SYSTEM MODEL NO. HM12YJ INDOOR MODEL MWH12Y3J OUTDOOR MODEL MRH12Y3J SPECIFICATIONS CAPACITY COOLING Btu 12,000 CAPACITY COOLING (MIN~MAX) Btu Pending CAPACITY HEATING Btu 13,600 CAPACITY HEATING (MIN~MAX) Btu Pending COOLING AMPS 3.8 HEATING AMPS 4.3 SENSIBLE HEAT RATIO .84 SEER 25.0 EER 14.0 HSPF 11.0 ENERGY STAR Yes MOISTURE REMOVAL Pts/h 1.7 AIRFLOW (QUIET, LOW, MED, HIGH) CFM 177 / 283 / 417 / 494 SOUND RATING - INDOOR dB-A 42 / 36 / 25 / 17 SOUND RATING - OUTDOOR dB-A 51 OPERATING RANGE (COOLING) °F 14.0(0)~118.4 OPERATING RANGE (HEATING) °F 14~75.2 EST. YEARLY OPERATING COST $ 77 ELECTRICAL DATA POWER SOURCE V 208/230 MINIMUM AMPACITY A COOLING WATTS W 857 HEATING WATTS W 960 MAX. TD FUSE/BREAKER A 15 POWER AND COMMUNICATION CABLE REFRIGERATION SYSTEM REFRIGERANT R410A COMPRESSOR TYPE Twin Rotary CONNECTIONS Flare LIQUID LINE O.D. in 1/4 SUCTION LINE O.D. in 3/8 FACTORY PRECHARGE ft 44.1 MAX. LINE LENGTH ft 49.2 MAX. HEIGHT DIFFERENCE ft 23 DIMENSIONS & WEIGHT INDOOR UNIT W X H X D in 34-7/16 x 11-5/8 x 9-1/4 NET WEIGHT lbs 25 SHIPPING WEIGHT lbs 29 OUTDOOR UNIT W X H X D in 34-5/16 x 25-7/8 x 12-5/8 NET WEIGHT lbs 95 SHIPPING WEIGHT lbs 100 TOTAL NET WEIGHT lbs 119 TOTAL SHIPPING WEIGHT lbs 128
NOTE: All R410 models have 1/2" UNF 20 thread per inch charging and vacuuming ports. An adapter must be used for 1/4" gauges. Adapter part number 67270018 is available through Friedrich parts distributors.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
No. x AWG