Friedrich M30YJ Installation Manual

Installation Manual
TYPE : 4-WAY CEILING CASSETTE
ENGLISH
FRANÇAIS
ESPAÑOL
960-911-07
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition­er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
TIPS FOR SAVING ENERGY
TIPS FOR SAVING ENERGY
2
ENGLISH
3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation of all field wiring and components MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code 70 and the National Building Construction and Safety Code or Canadian Electrical code and National Building Code of Canada.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal­function, property damage, personal injury and/or death.
Installation
• Always perform grounding. - Otherwise, it may cause electrical shock.
• Don’t use a power cord, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire or electrical shock.
• For installation of the product, always contact the service center or a professional installation agency. - Otherwise, it may cause a fire, electrical shock, explosion or injury.
• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
- If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Always install an air leakage breaker and a dedicated switching board. - No installation may cause a fire and electrical shock.
• Do not keep or use flammable gases or combustibles near the air conditioner. - Otherwise, it may cause a fire or the failure of product.
• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
- It may cause injury or an accident.
• Do not disassemble or repair the product randomly. - It will cause a fire or electrical shock.
• Do not install the product at a place that there is concern of falling down. - Otherwise, it may result in personal injury.
• Use caution when unpacking and installing. - Sharp edges may cause injury.
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion. There is the risk of death, injury, fire or explosion.
!
!
!
SAFETY PRECAUTIONS
ENGLISH
Operation
• Do not share the outlet with other appliances. - It will cause an electric shock or a fire due to heat generation.
• Do not use the damaged power cord. - Otherwise, it may cause a fire or electrical shock.
• Do not modify or extend the power cord randomly. - Otherwise, it may cause a fire or electrical shock.
• Take care so that the power cord may not be pulled during operation. - Otherwise, it may cause a fire or electrical shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it. - Otherwise, it may cause electri­cal shock or a fire.
• Keep the flames away. - Otherwise, it may cause a fire.
• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands. - Otherwise, it may cause a fire or electrical shock.
• Do not use the power cord near the heating tools. - Otherwise, it may cause a fire and electrical shock.
• Do not open the suction inlet of the indoor/outdoor unit during operation. - Otherwise, it may electri­cal shock and failure.
• Do not allow water to run into electrical parts. - Otherwise, it may cause the failure of machine or electrical shock.
• Hold the plug by the head when taking it out. - It may cause electric shock and damage.
• Never touch the metal parts of the unit when removing the filter. - They are sharp and may cause injury.
• Do not step on the indoor/outdoor unit and do not put anything on it. - It may cause an injury through dropping of the unit or falling down.
• Do not place a heavy object on the power cord. - Otherwise, it may cause a fire or electrical shock.
• When the product is submerged into water, always contact the service center. - Otherwise, it may cause a fire or electrical shock.
• Take care so that children may not step on the outdoor unit. - Otherwise, children may be seriously injured due to falling down.
CAUTION
Installation
• Install the drain hose to ensure that drain can be securely done. - Otherwise, it may cause water leakage.
• Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. - Otherwise, it may cause dispute with the neighbors.
• Always inspect gas leakage after the installation and repair of product. - Otherwise, it may cause the failure of product.
• Keep level parallel in installing the product. - Otherwise, it may cause vibration or water leakage.
Operation
• Avoid excessive cooling and perform ventilation sometimes. - Otherwise, it may do harm to your health.
• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. - The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
• Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. - Otherwise, it may damage your properties.
• Do not place obstacles around the flow inlet or outlet. - Otherwise, it may cause the failure of appli­ance or an accident.
!
SAFETY PRECAUTIONS
4
ENGLISH
5
2 TIPS FOR SAVING
ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
6 INSTALLATION PLACES
7 THE INDOOR UNIT
INSTALLATION
8 Indoor Unit Drain Piping
9 Wiring Connection
11 INSTALLATION OF DEC-
ORATIVE PANEL(ACCES­SORY)
13 TEST RUNNING
14 INSTALLATION
INSTRUCTIONS
14 Installer Setting - How to enter installer
setting mode
15 Installer Setting - Installer Setting
Code Table
TABLE OF CONTENTS
TABLE OF CONTENTS
ENGLISH
6
ENGLISH
INSTALLATION PLACES
INSTALLATION PLACES
- There should not be any heat source or steam near the unit.
- There should not be any obstacles to prevent the air circulation.
- A place where air circulation in the room will be good.
- A place where drainage can be easily obtained.
- A place where noise prevention is taken into consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
- The indoor unit must keep the maintenance space.
)
16
/
13
Ceiling Board
or more
300(11-
500(19-11/16)
or more
Ceiling
Ceiling Board
500(19-11/16)
or more
)
8
/
3
or more
1000(39-
)
16
/
7
) or less
2
/
1
Above 2500(98-
4000(157-
Unit:mm(inch)
) or less
16
/
13
300(11-
Floor
7
ENGLISH
THE INDOOR UNIT INSTALLATION
Level gauge
Ceiling
Ceiling board
TM/TN/TP Chassis
Unit:mm(inch)
875(34-7/16) (Ceiling opening)
787(30-15/16)
(Hanging bolt)
bolt)
684(26-15/16)(Hanging bolt)
671(2 6-7/16)
875(34-7/16) (Ceiling opening)
840(33-1/16)
Unit size
840(33-1/16)
Unit size
CAUTION
• This air-conditioner uses a drain pump.
• Install the unit horizontally using a level gauge.
• During the installation, care should be taken not to damage electric wires.
!
THE INDOOR UNIT INSTALLATION
- Select and mark the position for fixing bolts and piping hole.
- Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose.
- Drill the hole for anchor bolt on the wall.
- When using cardboard on the bottom of packaging, use after separating installation paper from bottom of the product packaging using back of a knife as shown in the picture (TM/TN/TP)
Included Paper Cardboard on the bottom
of packaging
NOTE
!
Avoid the following installation location.
1 Such places as restaurants and kitchen
where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions;
- Make sure that ventilation fan is enough to cover all noxious gases from this place.
- Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Air conditioner
Take enough distance
Cooking table
Use the ventilation fan for smoke-collecting hood with sufficient capacity.
Set screw of
paper model (4 pieces) Paper model for installation
Ceiling board
150mm
(5-7/8 inch)
Ceiling board
Ceiling
Keep the length of the bolt
from the bracket to 40mm(1-1/2 inch)
Open the ceiling board along the outer edge of the paper model
Air Conditioner body
Keep the length of 15~18mm(5/8~3/4 inch) between the air conditioner bottom surface and the ceiling surface
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut (W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Flat washer with insulation attached (Install insulation to be in contact with the indoor unit hanger part.)
Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 mm(2.8 inch) hole-core drill.
The following parts is option.
Hanging Bolt - W 3/8 or M10Nut - W 3/8 or M10Spring Washer - M10Plate Washer - M10
CAUTION
Tighten the nut and bolt to prevent unit falling.
!
Maintenance drain port
Upward routing not allowed
Pipe clamp
Indoor unit
Indoor Unit Drain Piping
- Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow.
- During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.
- The outside diameter of the drain connection on the indoor unit is 32 mm(1.3 inch).
- Be sure to execute heat insulation on the drain piping.
- Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm(11.8 inch) from the unit.
Piping material: Polyvinyl chloride pipe VP­25 and pipe fittings
8
THE INDOOR UNIT INSTALLATION
ENGLISH
2 Avoid installng air conditioner in such
places where cooking oil or iron powder is generated.
3 Avoid places where flammable gas is gen-
erated.
4
Avoid place where noxious gas is generated.
5
Avoid places near high frequency generators.
Wall
Indoor
Outdoor
5~7mm
(0.20~0.29 inch)
9
THE INDOOR UNIT INSTALLATION
800(31-1/2)
or less
1,000(39.4)~ 1,500(59.1)
Clamp metal(attached) Drain hose(attached)
Drain raising pipe
300(11.8)
or less
Unit:mm(inch)
Heat insulation material: Polyethylene foam with thickness more than 8mm(0.3inch).
Drain test The air conditioner uses a drain pump to drain
water. Use the following procedure to test the drain
pump operation:
- Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end.
- Feed water to the flexible drain hose and check the piping for leakage.
- Be sure to check the drain pump for normal operating and noise when electrical wiring is complete.
- When the test is complete, connect the flexi­ble drain hose to the drain port on the indoor unit.
HEAT INSULATION
- Use the heat insulation material for the refrigerant piping which has an excellent heat-resistance (over 248°F(120°C)).
- Precautions in high humidity circumstance: This air conditioner has been tested accord­ing to the "KS Standard Conditions with Mist" and confirmed that there is not any default. However, if it is operated for a long time in high humid atmosphere (dew point tempera­ture: more than 74.4°F/23°C), water drops are liable to fall. In this case, add heat insula­tion material according to the following pro­cedure:
- Heat insulation material to be prepared... Adiabatic EPDM or NBR with thickness 10(0.4) to 20 mm(0.8 inch).
- Stick glass wool on all air conditioners that are located in ceiling atmosphere.
Wiring Connection
- Open the control box cover and connect the Remote controller cord and Indoor power wires.
- Remove the control box cover for electrical connection between the indoor and outdoor unit. (Remove screws )
- Use the cord clamper to fix the cord.
Remote controller cord
1
1
Connection cord between the indoor unit and the outdoor unit
Control box cover (On which the Electric Wiring Connection is put)
CAUTION
The supplied flexible drain hose should not be curved, neither screwed. The curved or screwed hose may cause a leakage of water.
!
ENGLISH
Feed water
Drain Pump
Flexible drain hose (accessory)
Main drain pipe
Drain port
Glue the joint
Drain hose connection Use the clip (accessory)
Indoor unit
Fastening band (accessory)
Refrigerant piping
Thermal insulator (accessory)
Drain pan
Max 300mm
Metal clamp
Insulation
Hanger distance
Hanger Bracket
1~15m
1/50~1/100 slope
Flexible drain hose
Max 800mm
10
ENGLISH
THE INDOOR UNIT INSTALLATION
Precautions when laying power wiring
Use round pressure terminals for connections to the power terminal block.
When none are available, follow the instruc­tions below.
- Do not connect wiring of different thickness-
es to the power terminal block. (Slack in the power wiring may cause abnormal heat.)
- When connecting wiring which is the same
thickness, do as shown in the figure below.
CAUTION
The connecting cable connected to the indoor and outdoor unit should be com­plied with the following specifications (This equipment shall be provided with a cord set complying with the national regu­lation).
!
CAUTION
The Power cord connected to the unit should be selected according to the fol­lowing specifications.
!
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent.
AWG18
20mm
35±5mm
GN/YL
10±3mm
Power wirer
Round pressure terminal
Connect same thickness
wiring to both sides.
It is forbidden to
connect two to one
side.
It is forbidden to
connect wiring of
different thicknesses.
- For wiring, use the designated power wire
and connect firmly, then secure to prevent outside pressure being exerted on the termi­nal block.
- Use an appropriate screwdriver for tightening
the terinal screws. A screwdriver with a small head will strip the head and make prop­er tighterning impossible.
- Over-tightening the terminal screws may
break them.
Lock nut
Conduit
Conduit mounting plate
11
ENGLISH
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
6 Open two screws of control panel cover.
Screw
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
The decorative panel has its installation direction. Before installing the decorative panel, always remove the paper template.
1 Remove the packing and take out air inlet
grille from front panel.
Front grille
2 Remove the Corner covers of the panel.
Coner cover
3 Fit the panel on the unit by inserting hooks
as shown in picture.
5 Fit the corner covers.
4 Insert two screws on diagonal corners of
panel. Do not tighten the bolts completely. (The fixing screws are included in the indoor unit box.) Check the alignment of panel with the ceil­ing. Height can be adjusted using hanging bolts as shown in picture. Insert the other two screws and tighten all screws com­pletely.
Hook clip
Hook
12
ENGLISH
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
7 Connect one display connector and two
vane control connectors of front panel to indoor unit PCB. The position marking on PCB is as: Display connector : CN-DISPLAY Vane control connector: CN-VANE 1,2
8 Close the cover for control box.
9 Fit the link on the panel as shown in pic-
ture. (The link is included in the front panel unit box.) (TM/TN/TP)
10 Attach the other side of link on the filter
guide of inlet grille. Install the air inlet grille and filter on the panel. (TM/TN/TP)
11 Install the air inlet grille and Filter on the
panel.
CN-VANE 1,2
CN-DISPLAY
LinLink
Link
Link
Lin
Link
Filte
Filter
guid
guide
Link
Filter guide
Link
Link
Filter guide
Air conditioner unit
Decorative panel
Fit the insulator (this part) and be careful for cool air leakage
Good example
Ceiling
board
Ceiling
board
Decorative panel
Air
Cool air leakage
(no good)
Bad example
Air conditioner unit
CAUTION
Install certainly the decorative panel. Cool air leakage causes sweating. Water drops fall.
!
13
ENGLISH
TEST RUNNING
TEST RUNNING
PRECAUTIONS IN TEST RUN
- The initial power supply must provide at least 90% of the rated voltage. Otherwise, the air conditioner should not be operated.
Connection of power supply
- Connect the power supply cord to the inde­pendent power supply. Circuit breaker is required.
- Operate the unit for 15 minutes or more.
CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETED
- After completing work, be sure to measure and record trial run properties, and store measured data, etc.
- Measuring items are room temperature, out­side temperature, suction temperature, blow out temperature, wind velocity, wind vol­ume, voltage, current, presence of abnormal vibration and noise, operating pressure, pip­ing temperature, compressive pressure.
- As to the structure and appearance, check following items.
* Is the circulation of air adequate? * Is the draining smooth? * Is the heat insulation complete
(refrigerant and drain piping)? * Is there any leakage of refrigerant? * Is the remote controller switch operated? * Is there any faulty wiring? * Are not terminal screws loosened?
(Torque for screw size) M4…..11 lbf.in / 118 N.cm(12 kgf.cm) M5…..18 lbf.in / 196 N.cm(20 kgf.cm) M6…..22 lbf.in / 245 N.cm(25 kgf.cm) M8…..53 lbf.in / 588 N.cm(60 kgf.cm)
- To cancel the test run, press any button.
CAUTION
• For test run, carry out the cooling opera­tion firstly even during heating season. If heating operation is carried out firstly, it leads to the trouble of compressor. Then attention must be paid.
• Carry out the test run more than 5 min­utes without fail. (Test run will be cancelled 18 minutes later automatically)
!
Evaluation of the performance
- Measure the temperature of the intake and discharge air.
- Ensure the difference between the intake temperature and the discharge one is more than 14.4°F(8°C) (Cooling) or reversely (Heating).
Thermometer
14
ENGLISH
Installer Setting - How to enter installer setting mode
INSTALLATION INSTRUCTIONS
1 With the SURGE button pressed, press the
RESET button.
2 By using the TEMPERATURE SETTING
button, set function code and setting value. (Please refer the Installer Setting Code Table.)
3 Press the ON/OFF button toward the
indoor unit 1 time.
4 Reset the remote controller to use the
general operation mode.
CAUTION
Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided.
!
Refer to the Installer Setting Code Table on the next page.
15
ENGLISH
Mode Override This Function is only for Non-Auto Changeover H/P model.
Ceiling Height Selection Indoor unit connected to wired remote controller operate as wired remote controller setting.
Group Control This function is only for group control. Please don’t set this function in case of non-group
control. After setting Group Control of the product, turn off the power then turn it back on after 1
minute.
Installer Setting - Installer Setting Code Table
No. Function Function Code Setting Value Remote Controller LCD
0 Mode Override
0
0 : Set to Master
1 : Set to Slave
1
Ceiling Height
Selection
1
1 : Standard
2 : Low
3 : High
4 : Super High
2 Group Control
2
0 : Set to Master
1 : Set to Slave
2 : Check Master/Slave
Loading...