Friedrich M12YG, M18CF, M24CF, M30CF, M36CF Brochure & Specs

...
D U C T L E S S S P L I T S Y S T E M S
SINGLE and MULTI-ZONE WALL MOUNTED, FLOOR/CEILING UNIVERSAL, CEILING CASSETTE and CEILING SUSPENDED.
DUCTLESS SPLIT SYSTEMS
The ultimate room air conditioner. Easy to install. Exceptionally quiet. Totally flexible.
Ductless splits are an innovative and efcient alternative to window and thru-the-wall units. They have the benets of a central system, without the difculty and expense of installing ductwork.
Like a central system, without the ductwork.
electric wiring
refrigerant lines
INDOOR UNIT
converts warm indoor air to
cold indoor air, conditioning
and dehumidifying the
room while ltering the air.
Unit is mounted high on
the wall.
REFRIGERANT LINES AND ELECTRICAL pass through
a 3” wall opening and run
along the exterior of the
building to the condensing
unit. Electrical hard-wiring
is required.
Easy to install
SEER ratings up to 20.0
All Friedrich ductless models exceed the federal 13.0 SEER requirements. And, a full one-third of our models have super high ratings ranging from 16.5 to 20.0 SEER.
Extremely quiet
Ductless systems keep the operating noise of the condensing unit outdoors, while the blower fan of the indoor unit remains whisper quiet.
Zone cooling flexibility
OUTDOOR CONDENSER
transfers heat to the outdoors.
Compact unit can be placed at ground level, hung on an
outside wall or placed on the
roof of a building
hard-wired
All Friedrich units feature advanced inverter technology
Inverter technology lets you reach the desired temperature faster, maintain it more accurately, and reduce energy costs. Inverter technology varies the compressor and condenser and indoor fan speeds, eliminating constant compressor start­ups/shut-downs that traditional technology requires to maintain the set temperature.
INVERTER
TECHNOLOGY
Initial startup
setpoint
Independently condition up to 4 separate rooms using only a single outdoor unit. Achieve the ultimate in comfort and energy control by cooling and heating only the rooms that are in use.
Inverter Technology Standard Technology
Inverter Energy Usage
2nd startup
Inverter reaches setpoint faster, then adjusts capacity as required to maintain accurate temp
1st shutdown
Standard Energy Usage
3rd startup
2nd shutdown
Variable capacity advantages
Inverter Technology allows each system to adjust capacity and cooling output to provide
only the amount of cooling needed at a given
time. For example, an 18,000 BTU/h system will operate even more efciently as a
15,500 if that is all that’s needed.
Zero duct loss
The DOE reports that ducted systems lose
an average of 25-40% in performance due to leaks, cracks or disconnections in ductwork. No ductwork means zero duct loss– ultra high efciency delivers directly to the room.
No dirty air ducts
Now there’s no need to clean dirty air ducts that can harbor dust, germs and allergens that are eventually blown into your home or
ofce.
Residential applications
• Room additions/renovations
• Homes without ductwork
• Bedrooms and family rooms
• Garage workshops
• Sunrooms
• Guest quarters
• Wine cellars
Commercial applications
• Computer rooms/server rooms
• Restaurant kitchen and prep areas
• Ofces in warehouse spaces
• Storage facilities
• Buildings where security concerns prevent the use of window units
• Internal areas without exterior wall access
Learn more about ductless
visit www.friedrich.com to see an online video that explains the advantages of Friedrich ductless split systems
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
Wall mounted single zone
Wall mounted multi-zone heat pumps
One wall-mounted indoor unit connected to one outdoor unit.
Features
• Auto swing louvers (up/down)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut aps close when unit is off for a sleeker appearance
• Washable, reusable air lters
• Removable front grille
• Auto-changeover (heat pump models)
LCD wireless remote
• LCD remote for each indoor unit
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat* modes
• Four fan speeds heating* or cooling: high/medium/low/quiet, plus auto-fan
• Secured remote control holder
• Four different transmitter codes to prevent unintentional interference with nearby units
Two, three or four wall-mounted indoor
units connected to one outdoor unit.
Features
• Auto swing louvers (up/down)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut aps close when unit is off
• Washable, reusable air lters
• Removable front grille
• Auto-changeover
• Low-ambient operation
MW09, MW12
Precise comfort from
one system in up to four
different rooms.
That’s the beauty– and
efciency of a Friedrich
Multi-zone system.
* Heat pump models only
Pictured: Single zone model MW09Y3G indoor unit. Multi-zone system M36QYF.
Appearance varies by model.
Cool only
model btu/h seer
M18CF 18000 19.0
M24CF 24200 18.0
M30CF 30700 15.0
M36CF 33100 15.0
Heat pumps
model btu/h seer
M09YG
M12YG
M18YF
M24YF
10000
11500
14000
18000 21600
24200 27600
8500
20.0
20.0
19.0
18.0
Multi-zone Heat pumps
model btu/h total btu seer
M18DYF
M21DYF
M24DYF
M27TYF
M30TYF
M33TYF
M36TYF1
M36TYF2
M36QYF
MR36
zone 1 zone 2 zone 3 zone 4
9500 9500
11000 11000 22000
9500 12000 11000 14000 25000 12000 12000 14000 14000 28000
9200 9200 9200 11200 11200 11200 33600
9300 9300 11800 11000 11000 14000 36000
9400 11800 11800 10700 13600 13600 37900
9100 9100 17000
9800 9800 18400 38000 11700 11700 11700 12700 12700 12700 38100
8800 8800 8800 8800 35200
9500 9500 9500 9500 38000
19000
21500
24000
27600
30400
33000
35200
35100
INVERTER
TECHNOLOGY
16.5
16.5
16.5
15.0
15.0
15.0
15.0
15.0
15.0
= cooling capacity
= heating capacity
Floor/ceiling universal heat pump
Ceiling cassette heat pump
Universal system may be located low against the wall or on the ceiling.
Features
• Auto swing louvers (up/down, left/right)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut aps close when unit is off for a sleeker appearance
• Auto-changeover
• Washable, reusable air lters
• Fresh air capability
LCD wireless remote
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat modes
• Three fan speeds heating or cooling: high/medium/low, plus auto-fan
• Four different transmitter codes
• Secured remote control holder
• Self-diagnostics
Features
• Auto-swing louvers (up/down)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-changeover
• Washable, reusable air lters
• Low-ambient operation
• Fresh air intake
• Two branch ducts for adjoining rooms (requires additional fan)
• Condensate pump: 31" lift
• Auto-shut aps close when unit is off
LCD wired remote
Seven-day programmable on/off timer
controls up to 16 units– individually or by zones
• Auto/cool/dry/fan/heat modes
• Self-diagnostics
• Three fan speeds heating or cooling: high/medium/low, plus auto-fan
1
9
/4"
low profile– 9 ¼" above ceiling
Heat pump
C24YF 22,200 BTU/h 15.0 SEER
24,200 BTU/h
mounts on the ceiling or low against the wall
Heat pump
S24YF 22,200 BTU/h 15.0 SEER
24,200 BTU/h
Ceiling suspended heat pump
Features
• Auto swing louvers (up/down, left/right)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut aps
• Washable, reusable air lters
• Fresh air capability
• Auto-changeover
• Low-ambient operation
• Optional DP-36 condensate pump
LCD wireless remote
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat modes
• Three fan speeds heating or cooling: high/medium/low, plus auto-fan
• Four different transmitter codes
• Secured remote control holder
• Self-diagnostics
Heat pump
S36YF 34,100 BTU/h 14.0 SEER
38,200 BTU/h
INVERTER
TECHNOLOGY
INVERTER
TECHNOLOGY
MR36MR24
PERFORMANCE RATINGS
Wall mounted cooling
PERFORMANCE RATINGS
SYSTEM MODEL NO. M18CF M24CF M30CF M36CF
INDOOR MODEL MW18C3F MW24C3F MW30C3F MW36C3F OUTDOOR MODEL MR18C3F MR24C3F MR30C3F MR36C3F Capacity Cooling BTU/h 18000 24200 30700 33100 Capacity Cooling Min - Max BTU/h 5500-19000 5200-26000 9900-34200 9900-34100 Sensible Heat Ratio 0.63 0.76 0.67 0.67 SEER 19.0 18.0 15.0 15.0 EER 10.4 10.5 8.9 8.2 Moisture Removal Pts/h 5.9 5.3 9.7 10.1 Airflow (Quiet, Low, Med, High) CFM 240/290/355/415 380/450/560/650 380/450/560/650 365/440/530/700 Sound Rating - Indoor dB-A 25/32/38/44 32/36/41/47 32/36/41/47 32/36/41/49 Sound Rating - Outdoor dB-A 50 52 53 54 Operating Range °F 0 - 115 0 - 115 0 - 115 0 -115
ELECTRICAL DATA
Power Source 230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1 Min. Ampacity A 16 21 22 22 Cooling Watts W 1730 2310 3460 4040 Max. TD Fuse/Breaker A 20 25 30 30
REFRIGERATION SYSTEM
Refrigerant R410A R410A R410A R410A Compressor Type INVERTER INVERTER INVERTER INVERTER Connections Flare Flare Flare Flare Liquid Line O.D. in 1/4 1/4 3/8 3/8 Suction Line O.D. in 1/2 5/8 5/8 5/8 Factory Precharge ft 49 49 66 66 Max. Line Length ft 66 98 164 164 Max. Height Difference ft 49 66 98 98
DIMENSIONS & WEIGHT
INDOOR UNIT
OUTDOOR UNIT
W x H x D in Net Weight lbs 21 31 31 31 Shipping Weight lbs 26 40 40 40 W x H x D in Net Weight lbs 88 97 137 137 Shipping Weight lbs 98 106 155 155
31 1/8 x 10 7/8 x 8 1/2 39 1/4 x 12 5/8 x 9 39 1/4 x 12 5/8 x 9 39 1/4 x 12 5/8 x 9
31 1/8 x 22 3/4 x 12 3/8 31 1/8 x 22 3/4 x 12 3/8 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13
Wall mounted heat pumps
SYSTEM MODEL NO. M09YG M12YG M18YF M24YF
INDOOR MODEL MW09Y3G MW12Y3G MW18Y3F MW24Y3F OUTDOOR MODEL MR09Y3G MR12Y3G MR18Y3F MR24Y3F Capacity Cooling BTU/h 8500 11500 18000 24200 Cooling Capacity Min - Max BTU/h 1700-10900 3100-13300 5500-19000 5200-26000 Sensible Heat Ratio 0.71 0.71 0.63 0.76
Capacity Heating @ 47°F BTU/h 10000 14000 21600 27600 Capacity Heating Min - Max BTU/h 1700-15000 3100-19100 4600-29000 4100-36200 Capacity Heating @ 17°F BTU/h 8500 11000 13700 17800 HSPF 10.0 10.0 10.0 10.0
SEER 20.0 20.0 19.0 18.0 EER 12.3 12.1 10.4 10.5 Moisture Removal Pts/h 2.8 3.8 5.9 5.3 Airflow (Quiet, Low, Med, High) CFM 178/260/361/444 178/260/361/444 240/290/355/415 380/450/560/650 Sound Rating - Indoor dB-A 22/33/38/43 22/33/38/43 25/32/38/44 32/36/41/47 Sound Rating - Outdoor dB-A 46 49 50 52 Operating Range COOL (HEAT) °F 0 - 115 (17-75) 0 - 115 (17-75) 0 - 115 (5-75) 0 - 115 (5-75)
ELECTRICAL DATA
Power Source 230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1 Min. Ampacity A 15 15 16 21 Cooling Watts W 690 930 1730 2310 Max. TD Fuse/Breaker A 15 15 20 30
REFRIGERATION SYSTEM
Refrigerant R410A R410A R410A R410A Compressor Type INVERTER INVERTER INVERTER INVERTER Connections Flare Flare Flare Flare Liquid Line O.D. in 1/4 1/4 1/4 1/4 Suction Line O.D. in 3/8 3/8 1/2 5/8 Factory Precharge ft 25 25 49 49 Max. Line Length ft 66 66 66 98 Max. Height Difference ft 49 49 49 66
DIMENSIONS & WEIGHT
INDOOR UNIT
OUTDOOR UNIT
W x H x D in Net Weight lbs 16.5 16.5 21 31 Shipping Weight lbs 21 21 26 40 W x H x D in Net Weight lbs 55 71 88 97 Shipping Weight lbs 63 78 98 106
31 1/8 x 10 1/4 x 7 5/8 31 1/8 x 10 1/4 x 7 5/8 31 1/8 x 10 7/8 x 8 1/2 39 1/4 x 12 5/8 x 9
26 x 21 1/4 x 11 3/8 26 x 21 1/4 x 11 3/8 31 1/8 x 22 3/4 x 12 3/8 31 1/8 x 22 3/4 x 12 3/8
Dual-zone heat pumps Quad-zone heat pumps
PERFORMANCE RATINGS
SYSTEM MODEL NO. M18DYF M21DYF M24DYF M36QYF
INDOOR MODEL 2 x MW09Y3FM MW09Y3FM MW12Y3FM 2 x MW12Y3FM 4 x MW09Y3FM OUTDOOR MODEL MR24DY3F MR24DY3F MR24DY3F MR36TQY3F Capacity Cooling BTU/h 9500 ea. 9500 ea. 12000 12000 ea. 8800 ea. Capacity Cooling Min - Max BTU/h 5100-11300 5100-11300 5100-13600 5100-13600 5100-11300 Sensible Heat Ratio 0.77 0.77 0.77 0.77 0.71
Capacity Heating @ 47°F BTU/h 11000 ea. 11000 ea. 14000 14000 ea. 9500 ea. Capacity Heating Min - Max BTU/h 5100-13000 ea. 5100-13000 ea. 5100-15400 ea. 5100-15400 ea. 5100-13000 ea. Capacity Heating @ 17°F BTU/h 9500 ea. 9500 ea. 11000 10500 ea. 6600 ea. HSPF 9.0 9.0 9.0 9.0
SEER 16.5 16.5 16.5 15.0 EER 12.2 11.2 10.4 8.8 Moisture Removal Pts/h 2.9 ea. 2.9 ea 3.7 ea. 3.7 ea. 2.9 ea. Airflow (Quiet, Low, Med, High) CFM 185/220/260/295 185/220/260/295 215/250/305/355 215/250/305/355 185/220/260/295 Sound Rating - Indoor dB-A 27/29/33/37 27/29/33/37 30/34/39/42 30/34/39/42 27/29/33/37 Sound Rating - Outdoor dB-A 52 52 52 52 Operating Range COOL (HEAT) °F 0 - 115 (14-75) 0 - 115 (14-75) 0 - 115 (14-75) 0 - 115 (14-75)
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total)
Power Source 230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1 Min. Ampacity A 15 15 15 22.5 Cooling Watts W 1600 1900 2300 3900 Max. TD Fuse/Breaker A 20 20 20 30
REFRIGERATION SYSTEM
Refrigerant R410A R410A R410A R410A Compressor Type INVERTER INVERTER INVERTER INVERTER Connections Flare Flare Flare Flare Liquid Line O.D. in 1/4 1/4 1/4 1/4 1/4 Suction Line O.D. in 3/8 3/8 3/8 3/8 3/8 Factory Precharge ft 98 98 98 165 Max. Line Length ft Each unit:82 Total:98 Each unit:82 Total:98 Each unit:82 Total:98 Each unit:82 Total:230 Max. Height Difference ft 33 33 33 49
DIMENSIONS & WEIGHT
INDOOR UNIT
OUTDOOR UNIT
W x H x D in 31 Net Weight lbs 21 ea. 21 21 21 ea. 21 ea. Shipping Weight lbs 26 ea. 26 26 26 ea. 26 ea. W x H x D in 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 Net Weight lbs 151 151 151 159 Shipping Weight lbs 164 164 164 172
1
/8 x 10 7/8 x 8 1/2 ea. 31 1/8 x 10 7/8 x 8 1/2 ea. 31 1/8 x 10 7/8 x 8 1/2 ea. 31 1/8 x 10 7/8 x 8 1/2 ea.
Tri-zone heat pumps
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL OUTDOOR MODEL Capacity Cooling BTU/h Capacity Cooling Min - Max BTU/h Sensible Heat Ratio
Capacity Heating @ 47°F BTU/h Capacity Heating Min - Max BTU/h Capacity Heating @ 17°F BTU/h HSPF
SEER EER Moisture Removal Pts/h Airflow (Quiet, Low, Med, High) CFM Sound Rating - Indoor dB-A Sound Rating - Outdoor dB-A Operating Range COOL (HEAT) °F
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total)
Power Source Min. Ampacity A Cooling Watts W Max. TD Fuse/Breaker A
REFRIGERATION SYSTEM
Refrigerant Compressor Type INVERTER INVERTER INVERTER INVERTER INVERTER Connections Liquid Line O.D. in Suction Line O.D. in Factory Precharge ft Max. Line Length ft Max. Height Difference ft
DIMENSIONS & WEIGHT
INDOOR UNIT
OUTDOOR UNIT
W x H x D in Net Weight lbs Shipping Weight lbs W x H x D in Net Weight lbs Shipping Weight lbs
M27TYF M30TYF M33TYF M36TYF1 M36TYF2
3 x MW09Y3FM 2 x MW09Y3FM MW12Y3FM MW09Y3FM 2 x MW12Y3FM 2 x MW09Y3FM MW18Y3FM 3 x MW12Y3FM
MR36TQY3F MR36TQY3F MR36TQY3F MR36TQY3F MR36TQY3F
9200 ea. 9300 ea. 11800 9400 11800 ea. 9100 ea. 17000 11700 ea.
5100-11300 5100-11300 5100-13600 5100-11300 5100-13600 5100-11300 5100-19000 5100-15400
0.71 0.71 0.71 0.71 0.71 0.71 0.71 0.71
11200 ea. 11000 ea. 14000 10700 13600 ea. 9800 ea. 18400 12700 ea.
5100-13000 5100-13000 5100-15400 5100-13000 5100-15400 5100-13000 5500-23000 5100-15400
8300 ea. 7700 ea. 9800 7200 9200 ea. 6700 ea. 12500 8600 ea.
9.0 9.0 9.0 9.0 9.0
15.0 15.0 15.0 15.0 15.0
10.0 9.2 8.8 8.8 8.8
2.9 ea. 2.9 ea. 3.7 2.9 3.7 ea. 2.9 ea. 5.7 3.7 ea.
185/220/260/295 185/220/260/295 215/250/305/355 185/220/260/295 215/250/305/355 185/220/260/295 240/290/355/415 215/250/305 /355
27/29/33/37 27/29/33/37 30/34/39/42 27/29/33/37 30/34/39/42 27/29/33/37 33/39/42/46 30/34/39/42
52 52 52 52 52
0 - 115 (14-75) 0 - 115 (14-75) 0 - 115 (14-75) 0 - 115 (14-75) 0 - 115 (14-75)
230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1 230/208-60-1
22.5 22.5 22.5 22.5 22.5 2710 3180 3710 4000 3980
30 30 30 30 30
R410A R410A R410A R410A R410A
Flare Flare Flare Flare Flare
1/4 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8 1/2 3/8 165 165 165 165 165
Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82 Total:230
49 49 49 49 49
31 1/8 x 10 7/8 x 8 1/2 ea. 31 1/8 x 10 7/8 x 8 1/2 ea. 31 1/8 x 10 7/8 x 8 1/2 31 1/8 x 10 7/8 x 8 1/2 31 1/8 x 10 7/8 x 8 1/2 31 1/8 x 10 7/8 x 8 1/2
21 ea. 21 ea. 21 21 21 ea. 21 ea. 21 21 ea. 26 ea. 26 ea. 26 26 26 ea. 26 ea. 26 26 ea.
35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13
159 159 159 159 159 172 172 172 172 172
Ceiling and Floor/ceiling universal heat pumps
PERFORMANCE RATINGS
SYSTEM MODEL NO. S24YF S36YF C24YF
INDOOR MODEL MS24Y3F MS36Y3F MC24Y3F OUTDOOR MODEL MR24UY3F MR36Y3F MR24UY3F Capacity Cooling BTU/h 22200 34100 22200 Capacity Cooling Min - Max BTU/h 5000-27300 8500-36000 5000-27300 Sensible Heat Ratio 0.62 0.67 0.64
Capacity Heating @ 47°F BTU/h 24200 36400 24200 Capacity Heating Min - Max BTU/h 5000-29000 9200-42700 5000-29000 Capacity Heating @ 17°F BTU/h 15000 23400 14600 HSPF 8.5 8.5 8.5
SEER 15.0 14.0 15.0 EER 9.8 8.1 10.6 Moisture Removal Pts/h 7.4 7.4 6.4 Airflow (Low, Med, High) CFM 371/436/518 842/977/1089 436/536/618 Sound Rating - Indoor dB-A 38/43/47 41/45/48 38/43/45 Sound Rating - Outdoor dB-A 53 54 53 Operating Range COOL (HEAT) °F 0 to 115
ELECTRICAL DATA
Power Source 230/208-60-1 230/208-60-1 230/208-60-1 Min. Ampacity A 15.5 23 15.5 Cooling Watts W 2250 4220 2100 Max. TD Fuse/Breaker A 20 30 20
REFRIGERATION SYSTEM
Refrigerant R410A R410A R410A Compressor Type INVERTER (Twin Rotary) INVERTER (Twin Rotary) INVERTER (Twin Rotary) Connections Flare Flare Flare Liquid Line O.D. in 3/8 3/8 3/8 Suction Line O.D. in 5/8 5/8 5/8 Factory Precharge ft 50 50 50 Max. Line Length ft 165 165 165 Max. Height Difference ft 66 98 66
DIMENSIONS & WEIGHT
W x H x D in 39 x 7 7/8 x 25 3/4 65 3/8 x 9 1/2 x 27 1/2 32 5/8 x 9 5/8 x 32 5/8
INDOOR UNIT
Net Weight lbs 62 106 75 Shipping Weight lbs 82 134 97
OUTDOOR UNIT
W x H x D Net Weight Shipping Weight
floor/ceiling universal ceiling suspended ceiling cassette
(14-75)
0 to 115
(14-75)
0 to 115
(14-75)
in 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 35 3/8 x 32 5/8 x 13 lbs 141 141 141 lbs 154 154 154
Refrigeration line sets
USED WITH: LENGTH-FT. LIQUID SUCTION KIT#
All 9000 and 12000 BTU/h Indoor Units
All 18000 BTU/h Indoor Units
All MW24Y3F and MW24C3F Units
All 30000 BTU/h Indoor Units and S24YF, S36YF and C24YF Units
Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF uses 2 line sets for 9,000 btu units, not 1 for the 18,000 btu product.
DRAIN PUMP USED WITH
DP-36 S36YF
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached.
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich par ts distributors.
15 1/4” 3/8” T32150
35 1/4” 3/8” T32350
15 1/4” 1/2” T42150
35 1/4” 1/2” T42350
15 1/4” 5/8” T52150
35 1/4” 5/8” T52350
15 3/8” 5/8” T53150
35 3/8” 5/8” T53350
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
Friedrich Air Conditioning Co. l P.O. Box 1540 l San Antonio, TX 78295-1540 l 800.541.6645 l fax 210.357.4480 www.friedrich.com
DSS-10 (6-10) Printed in USA