Easy to install. Exceptionally quiet.
Totally flexible.
Ductless splits are an innovative and ecient alternative
to window and thru-the-wall units. They have the benets
of a central system, without the diculty and expense of
installing ductwork. These are only a few of the benets
of ductless...
• Unobstructed window views.
• No need to uninstall and store unit during the winter.
• Independently-controlled zone cooling means up to four separate
indoor units working from a single outdoor unit.
• Save money by turning o units in unoccupied rooms.
• Set room temperatures based on individual preferences, instead of
one-size-ts-all.
all models use
R-410A
R EF RI GE RA NT
simple installation
Friedrich ductless split systems have the
advantages of a ducted installation without
the high material and labor costs. Absolutely
no ductwork is required, so most systems
can be installed and running in a few hours.
SEER ratings up to 19.0
All Friedrich ductless models exceed the
federal 13.0 SEER requirements. And, a full
one-third of our models have super high
ratings ranging from 16.5 to 19.0 SEER
signicantly outperforming 13 SEER product
on energy savings.
extremely quiet
Ductless systems keep the operating noise
of the condensing unit outdoors, while
the blower fan of the indoor unit remains
whisper quiet.
The indoor unit and outdoor unit are
connected by refrigerant and power
lines, through a small three-inch hole
in the exterior wall.
INDOOR UNIT
converts warm indoor
air to cold indoor air,
conditioning and
dehumidifying the room.
Unit is mounted high on
the wall.
OUTDOOR CONDENSER
transfers heat to the outdoors.
Compact unit can be placed
at ground level, hung on an
outside wall or placed on the
roof of a building
Like a central system, without the ductwork.
electric wiring
refrigerant lines
REFRIGERANT LINES AND
ELECTRICAL
a 3” wall opening and run
along the exterior of the
building to the condensing
unit. Electrical hard-wiring
pass through
is required.
hard-wired
zone 4
setpoint
Initial
startup
2nd
startup
3rd
startup
1st
shutdown
2nd
shutdown
Inverter TechnologyStandard Technology
Standard Energy Usage
Inverter rea ches
setpoint fas ter, the n
adjusts capa city as
required to maintain
accurate tem p
Inverter Energy Usage
prefers
76°
zone 3
constant
temperature
changes
zone 2
attending
seminar, unit
turned o
Multi-zone flexibility.
multiple conguration choices
Over 20 single, dual, tri- and quad-zone systems provide a wide range of
heating and cooling options for even the toughest remodels, additions and
improvements. A new level of system exibility and control is at your ngertips
on Friedrich single and multi-zone systems.
advanced inverter technology
Inverter Technology lets you reach the desired temperature faster, maintain it
more accurately, and reduce energy costs. It eliminates constant compressor
start-ups/shut-downs
that traditional
technology requires
to maintain the set
temperature.
zone 1
70° in
conference
room
Precise comfort from one
system in up to four dierent
rooms. That’s the beauty– and
eciency of a Friedrich Multi-
Zone system.
variable capacity
advantages
Inverter Technology
allows each system to
adjust capacity and
cooling output to
provide only the amount of cooling needed at a given time. For example, an
18,000 BTU/h system will operate even more eciently as a 15,500 if that is all
that’s needed.
residential applications
• Room additions/renovations
• Homes without ductwork
• Bedrooms and family rooms
• Garage workshops
• Four season sunrooms
• Guest quarters
• Wine cellars
commercial applications
• Computer rooms/server rooms
• Restaurant kitchen and prep areas
• Oces in warehouse spaces
• Storage facilities
• Buildings where security concerns prevent
the use of window units
• Internal areas without exterior wall access
Commercial applications
including restaurant dining areas
and kitchens
A multi-zone system
allows you to
condition up to four
rooms or areas.
Wall-mounted single zone
One wall-mounted indoor unit
connected to one outdoor unit.
Wall-mounted multi-zone heat pump
Two, three or four wall-mounted indoor
units connected to one outdoor unit.
Each indoor unit can
be independently
controlled for
optimum flexibility,
best comfort and
increased energy
savings.
Fully featured and fully
programmable for
total convenience
Auto-shut flaps close
when unit is off for a
sleeker appearance.
The continuous ‘Air
Sweep’ auto louvers
gently distribute cool or
warm air throughout
the room.
Auto-changeover on
heat pump models
automatically switches
the unit from cool to
heat; or from heat to
cool to maintain desired
temperature.
= cooling capacity
= heating capacity
features
• Auto swing louvers (up/down)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut flaps close when unit is off
for a sleeker appearance
• Washable, reusable air filters
• Removable front grille
• Auto-changeover (heat pump models)
features
• Auto swing louvers (up/down)
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-shut flaps close when unit is off
• Washable, reusable air filters
• Removable front grille
• Auto-changeover
• Low-ambient operation
wireless remote
• Remote for each indoor unit
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat* modes
• Four fan speeds heating* or cooling:
high/medium/low/quiet, plus auto-fan
• Secured remote control holder
• Four different transmitter codes to prevent
unintentional interference with nearby units
* Heat pump models only
Pictured: Single zone model MW24CF indoor unit. Multi-zone system M36QYF.
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total)
Power Source230/208-60-1230/208-60-1230/208-60-1230/208-60-1
Min. AmpacityA15151522.5
Cooling WattsW1600190023003900
Max. TD Fuse/BreakerA20202030
REFRIGERATION SYSTEM
RefrigerantR410AR410AR410AR410A
Compressor TypeInverterInverterInver terInverter
ConnectionsFlareFlareFlareFlare
Liquid Line O.D.in1/41/41/41/41/4
Suction Line O.D.in3/83/83/83/83/8
Factory Prechargeft989898165
Max. Line LengthftEach unit:82 Total:98Each unit:82 Total:98Each unit:82 Total:98Each unit:82 Total:230
Max. Height Differenceft33333349
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x Din 31 1/8 x 10 7/8 x 8 1/2 ea.31 1/8 x 10 7/8 x 8 1/2 ea.31 1/8 x 10 7/8 x 8 1/2 ea.31 1/8 x 10 7/8 x 8 1/2 ea.
Net Weightlbs21 ea.212121 ea.21 ea.
Shipping Weightlbs26 ea.262626 ea.26 ea.
OUTDOOR UNIT
W x H x Din35 3/8 x 32 5/8 x 1335 3/8 x 32 5/8 x 1335 3/8 x 32 5/8 x 1335 3/8 x 32 5/8 x 13
Net Weightlbs151151151159
Shipping Weightlbs164164164172
dual-zone heat pumps quad-zone heat pumps
inverter model
tri-zone heat pumps
USED WITH:LENGTH-FT.LIQUIDSUCTIONKIT#
All 9000 and 12000 BTU/h
Indoor Units
151/4”3/8”T32150
351/4”3/8”T32350
All 18000 BTU/h Indoor Units
151/4”1/2”T42150
351/4”1/2”T42350
All MW24Y3F and MW24C3F Units
151/4”5/8”T52150
351/4”5/8”T52350
All 30000 BTU/h Indoor Units and
S24YF, S36YF and C24YF Units
Power Source230/208-60-1230/208-60-1230/208-60-1
Min. AmpacityA15.52315.5
Cooling WattsW225042202100
Max. TD Fuse/BreakerA203020
REFRIGERATION SYSTEM
RefrigerantR410AR410AR410A
Compressor TypeInverter (Twin Rotary)Inver ter (Twin Rotary)Inverter (Twin Rotary)
ConnectionsFlareFlareFlare
Liquid Line O.D.in3/83/83/8
Suction Line O.D.in5/85/85/8
Factory Prechargeft505050
Max. Line Lengthft165165165
Max. Height Differenceft669866
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x Din39 x 7 7/8 x 25 3/465 3/8 x 9 1/2 x 27 1/232 5/8 x 9 5/8 x 32 5/8
Net Weightlbs6210675
Shipping Weightlbs8213497
OUTDOOR UNIT
W x H x Din35 3/8 x 32 5/8 x 1335 3/8 x 32 5/8 x 1335 3/8 x 32 5/8 x 13
Net Weightlbs141141141
Shipping Weightlbs154154154
ceiling and oor/ceiling universal heat pumps
inverter model
refrigeration line sets
Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and
suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor
unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF
uses 2 line sets for 9,000 btu units, not 1 for the 18,000 btu product.
DRAIN PUMPUSED WITH
DP-36S36YF
Friedrich Air Condit ioning C o. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.fr iedr ich.com
DSS-08 Printed in USA
NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached.
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used
for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich par ts distributors.
all models use
R-410A
R EF RI GE RA NT