Ductless Split Systems
Series
Our 16 SEER line offers superb performance and
excellent value.
FRIEDRICH.COM THE EXPERTS IN ROOM AIR CONDITIONING

Floating Air® Series
16 SEER ductless line offers superb
performance at mid-tier pricing
Inverter variable capacity
advantages
Inverter technology varies the compressor
speed and the indoor fan speed, eliminating
constant compressor start-ups/shut-downs
that traditional systems require to maintain
the temperature set point.
The system can adjust capacity and cooling
output to provide only the amount of cooling
needed at a given time. The result is
optimal comfort with low energy costs.
5/5 year warranty
Friedrich Floating Air ductless units feature
a 5 year compressor waranty, as well as a 5
year parts warranty.
Auto restart
Auto restart function allows system to
resume with previous settings in the event
of a power shutdown. (Power supply must
be restored).
Optimum air ow
Air is directed downward in heating mode
and angled upward during cooling mode so
the room feels more comfortable faster.
INVERTER VS. TRADITIONAL HVAC SYSTEMS
TRADITIONAL SYSTEM INVERTER SYSTEM
At initial star t up, fixed capacity
system slowly reaches the set
temperature.
Complete shutdown once set
temperature is achieved.
Temperature rises until 2nd
system start up.
System works at full capacity to
again reach set temperature.
System cycles on and off
continually to maintain the set
temperature.
At initial start up, utilizes
variable capacity to quickly
reach the set temperature.
Reduces capacity as set
temperature is achieved.
Variable capacity maintains
set temperature keeping space
comfortable with reduced
energy consumption.
BETTER COMFORT, MORE ENERGY SAVINGS
A. Inverter Energy Usage
Variable capacity inverter reaches setpoint faster and maintains
precise temperature with minimal energy use.
B. Non inverter Energy Usage
Non-inverter technology is slow to reach setpoint, runs at full
capacity, then shuts off and on with wide temperature swings.
T
EMP
R
A
N
setpoint
G
E
Continuous Air Sweep
The indoor unit’s up/down air swing quickly
disperses cool air to all four corners of the
room to provide comfort throughout the
room within a few minutes.
TIME

Heat Pump Models
®
DFACC
Optional accessory
remote for cooling
only operation of
all Floating Air heat
pump models.
115 volt
MM09YJ
9000 Btu cooling
9800 Btu heating
MM12YJ
11800 Btu cooling
13000 Btu heating
230/208 volt
MM18YJ
18000 Btu cooling
23000 Btu heating
MM24YJ
22000 Btu cooling
26600 Btu heating
Comfort & Convenience
• All models offer heating and
cooling capabilities
• Inverter technology is more
energy efcient and can
self-adjust capacity to match
cooling needs
• Multiple operating modes
including: AUTO, COOL, DRY,
FAN ONLY and HEAT
• TURBO mode operates the unit
at maximum performance to
quickly bring the room to set
temperature
• 4 fan speeds heating or
cooling: HIGH, MEDIUM, LOW,
“QUIET”, plus AUTO-FAN
• Continuous ‘Air Sweep’ UP &
DOWN
• LCD remote
• 24-hour timer and sleep timer
• Indoor unit will briey display
set or room temperature
• Auto-restart after power
interruptions
• Auto-shut aps close when unit
is off for a sleek appearance
• Washable, long-life,
antimicrobial air lters
• 230 volt models will provide
cooling in outdoor temperatures
down to 5˚ F
Coming in 2016
MM36YJ
33600 Btu cooling
34600 Btu heating

SPECIFICATIONS
PERFORMANCE RATINGS 115 volt models 230/208 models
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
CAPACITY COOLING (RATED) Btu
CAPACITY COOLING MIN - MAX Btu
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
CAPACITY HEATING (RATED) @ 47°F Btu
CAPACITY HEATING MIN - MAX Btu
CAPACITY HEATING (RATED) @ 17°F Btu
HSPF
SEER
EER
ENERGY STAR
MOISTURE REMOVAL Pts/h
AIRFLOW (HIGH/MED/LOW/QUIET) CFM
SOUND RATING - INDOOR (HIGH/MED/LOW/QUIET) dB-A
SOUND RATING - OUTDOOR dB-A
OPERATING RANGE (HEATING) °F
OPERATING RANGE (COOLING) °F
EST. YEARLY OPERATING COST U.S. $
ELECTRICAL DATA
POWER SOURCE V/Hz/Phase
MIN. AMPACITY A
COOLING WATTS W
HEATING WATTS W
MAX. TD FUSE/BREAKER A
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D. in
SUCTION LINE O.D. in
REFRIGERANT CHARGE oz.
FACTORY PRECHARGE ft
MIN. / MAX. LINE LENGTH ft
MAX. HEIGHT DIFFERENCE ft
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x D in
NET WEIGHT lbs
SHIPPING WEIGHT lbs
OUTDOOR UNIT
W x H x D in
NET WEIGHT lbs
SHIPPING WEIGHT lbs
TOTAL NET WEIGHT lbs
TOTAL SHIPPING WEIGHT lbs
MM09YJ MM12YJ MM18YJ MM24YJ MM36YJ
MWM09Y1J MWM12Y1J MWM18Y3J MWM24Y3J MWM36Y3J
MRM09Y1J MRM12Y1J MRM18Y3J MRM24Y3J MRM36Y3J
9000 11800 18000 22000 33600
3500~11000 3300~12500 4500~21000 6400~24000 7404~35997
9.00 15.00 7.85/7.10 11.50/10.50 17.0/17.0
9.50 15.5 10.60/11.80 12.80/13.00 16.5/16.5
0.79 0.73 0.77 0.77 0.75
9800 13000 23000 26600 34600
2500~11000 3400~13500 4000~23000 4100~26600 14979~35997
5400 8500 12000 18600 —
8.6 8.6 8.5 8.5 9.0
16.0 16.0 16.0 16.0 18.0
12.00 9.40 11.11 10.00 8.20
Y N N N N
1.69 2.96 3.80 4.50 7.40
330/277/224/188 341/288/235/200 471/400/330/271 588/441/306/206 736/647/530/412
41/37/35/32 43/39/35/32 48/43/38/34 49/43/39/34 54/49/44/37
53 55 56 53 65
5-75 5-75 5-75 5-75 -4-75
32*-113 32*-113 5-118 5-115 0~109
67 113 146 198 —
115/60/1 115/60/1 208/230/60/1 208/230/60/1 208/230/60/2
13 15 15 16 24
750 1260 1620 2200 4100
830 1320 2400 2800 3800
20 25 25 25 40
R410A R410A R410A R410A R410A
Inverter Inverter Inverter Inverter Inverter
Flare Flare Flare Flare Flare
1/4” 1/4” 1/4” 1/4” 1/4”
3/8” 3/8” 1/2” 1/2” 5/8”
35.3 35.3 45.8 54.7 91.7
24.6 24.6 24.6 24.6 24.6
7 / 65 7 / 65 10 / 82 10 / 82 98
32 32 32 32 32
30”× 11”× 8” 34”× 12”× 8” 39 11/16”× 12 3/8”× 8” 53”x13”x10”
19 19 26 33 42
25 25 35 44 52
33 3/8”× 24 1/4”× 12 5/8” 37 5/8 x 27 5/8 x 15 5/8 38 1/4”x 31”x 17”
68 68 106 115 161
77 77 117 126 172
87 87 132 148 203
102 102 152 170 224
*Capacity is reduced as 32 degrees Fahrenheit is approached.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com
BRO_FADSS_COMM_2016 (Rev. 1) Printed in USA