Friedrich M09CJ, M12CJ, M09YJ, M12YJ, M18YJ Installation

...
Models
Indoor Unit
Outdoor Unit
960-910-05
MWM09Y1J MWM
12Y1J
MRM09Y1J MRM12Y1J
CONTENTS
Operation and maintenance
Notices for use
Names and functions of each part
Operation of remote controller
Emergency operation
...............................................................1
......................................................10
........................................3
.............................................4
Routine Maintenance
Basic Troubleshooting
Service & Assistance
.....................................................11
...................................................12
....................................................14
Installation service
Service & Assistance
Notices for installation
Installation dimension diagram
Install indoor unit
Install outdoor unit
Check after installation and test operation
This symbol stands for the items should be forbidden.
Thank you for choosing carefully before operating the unit and keep it carefully for consulation.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
.....................................................15
.....................................................16
..........................................17
............................................................19
.........................................................20
...........................21
This symbol stands for the items should be followed
Friedrich Air Conditioning
, please read this owner's manual
Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
Congratulations
WARNING
Read Installation Operation Manual
Please read this manual thoroughly prior to equipment installation or operation.
It is the installer’s responsibility to properly apply and install the equipment. Installation must be in conformance with the NFPA 70
-2008 National Electric Code or current edition, International Mechanic Code 2009 or current edition and any other applicable local or national codes.
Failure to do so can result in property damage, personal injury or death.
Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable,
efcient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation,
the greatest circulation of cool, dry air, and the most economic operation.
General Instructions
This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit. For years of trouble-free service, please follow the installation instructions closely. We cannot overemphasize the importance of proper installation.
and the controls are properly set, the unit may need service and
WARNING
Refrigeration system
under high pressure
Do not puncture, heat, expose to flame or incinerate.
Only certified refrigeration technicians should service this equipment.
R410A systems operate at higher pressures than R22 equipment. Appropriate safe service and handling practices must be used.
Only use gauge sets designed for use with R410A. Do not use standard R22 gauge sets.
Here are some suggestions to help you use your new Friedrich most efficiently:
1. Carefully read and follow the installation instructions.
2. Make sure the unit is the right capacity for the area being cooled.
An undersized unit makes the unit work too hard, using more electricity than needed and increases wear. An oversized unit will cycle on and off too rapidly, and therefore cannot control humidity as well.
Clean the filter frequently (See Routine Maintenance, Page 23).
3.
4. Do not block the air ow to and from the unit.
5. A dirty lter or improperly set controls can affect the cooling
ability of the unit.
6. If cooling is weak and you have veried that the lter is clean
you should call your Friedrich service provider to check the unit.
7. Keep blinds, shades and drapes closed on the sunny side of the room being cooled to reduce radiant heat.
8. Proper insulation helps your unit maintain the desired inside temperature.
9. Whenever possible, shade south and west facing windows.
10. Keep window coverings away from the unit to provide free air ow.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is a safety Alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol with the word “WARNING” or “CAUTION”. These words mean:
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what will happen if the instructions are not followed.
ANIN
WARNING
CAUTION
NOTICE
Indicates a hazard which, if not avoided, can result in severe personal injury or death and damage to product or other property.
Indicates a hazard which, if not avoided, can result in personal injury and damage to product or other property.
Indicates property damage can occur if instructions are not followed.
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will
*
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
*
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
*
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop running about 1min.
1
.
Notices for use
Working temperature range
Indoor side DB/WB(ºF)
Maximum cooling
Maximum heating
The operating temperature range (outdoor) heat pump unit is 5ºF~ 109ºF. 115V
Model
90/73
81/---
Outdoor side DB/WB(ºF)
109/79
75/64
2
Names and functions of each part
Indoor unit
Air inlet
Front panel
Filter
Guide louver
Air outlet
Wrapping Tape
Wall Pipe
SET TEMP
Cool Heat
ON/OFF
Outdoor unit
Air in
Dry Run
Receive
Air out
Wireless
remote control
Drainage pipe
3
Operation of Remote Controller
4
1
START / STOP
Press to start or stop operation.
2
3
4
FAN
Press to set fan speed.
5
MODE
Press to select operation mode (AUTO/COOL/DRY/FAN/HEAT).
6
SENSOR
7
CLOCK
Press it set clock.
8
2
1
4
6
3
5
TIMER ON
Press it to set auto-on timer.
9
AIR SWEEP
10
EXTEND
: Press to decrease temperature
setting.
: Press to increase temperature
setting.
AUTO
Press it set swing angle.
10
7
13
11
14
8
9
12 15
11
TEMP
12
TIMER OFF
Press it to set auto-off timer
13
TURBO
14
SLEEP
15
LIGHT
Press it to turn on/off the light.
Loading...
+ 18 hidden pages