Control with smart phone or computer with
FriedrichLink
Auto-restart w/setting retentionYYYY
Auto temp/ fan speed adjustmentYY——
Auto-changeover—All except EQ08——
COMFORT & CONVENIENCE
Air ow directions8844
Auto swing louvers——All except CP05Y
Optional color frontsYY——
Steel inner wall and extra dense insulationYY——
Vibration isolating design and
components
TECHNOLOGY
Superior airflow designYY——
SOUND REDUCTION
ENERGY STAR® modelsYYY—
Smart Grid capableYY——
®
(accessory required)
Programmability to rival
central systems. Trusted
Friedrich durability.
Designer colors.
COOL
COMMERCIAL AND
RESIDENTIAL
7-day with up to 4
settings per day*;
24 hr. timer
YY——
YY——
All the performance and
durability of Kühl, plus
heating. Choose efcient
heat pump or toasty
HEAT/COOL
COMMERCIAL AND
7-day with up to 4
settings per day*;
®
Kühl
+Chill
electric heat.
RESIDENTIAL
24-hr. timer
Good value. Available
in a large range of
cooling capacities.
24-hr. timer.
COOL
RESIDENTIAL AND LIGHT
COMMERCIAL
®
24 hr.24-hr.
®
Chill
+
Good value. Four models
with electric heat.
24-hr. timer.
HEAT/COOL
RESIDENTIAL AND LIGHT
COMMERCIAL
Product Selection Tools
These tools are only a guide. Due to variations in room design, local climate
and occupancy, larger areas may require the use of multiple units to provide
the optimal cooling solution. Please consult your local authorized Friedrich
distributor or the Friedrich Technical Assistance team for sizing or
application assistance.
COOLING SIZING GUIDE
The cooling guide to the right is based on normal room insulation, average
number of sun-exposed windows and two-person occupancy.
HEATING SIZING INFORMATION
In heating mode, an energy efcient heat pump will generate slightly less
heating Btus than it would in cooling mode. However, in heating mode, heat
pumps use approximately 1/3 the energy of resistance heat, making them an
excellent high-efciency alternative. Back-up resistance heat ensures heat
operation below 40� F outdoor temperatures for year ‘round comfort.
Common Window Types
Traditional wooden windows are typical in many residences built before
1965, but more modern windows are often constructed of aluminum or vinyl.
Many newer energy efcient windows like double-glazed windows actually
sandwich low conductance gas between two panes of glass. While Friedrich air
conditioners may be used with this type of window, care should be taken not to
break the seal between the two panes of glass during installation.
Depending on the style of window in the application, you may want to consider
the cooling solutions in the adjacent chart. Professional installers may be able
to make eld adaptations, including removing all or part of a window to support
alternative types of air conditioning units. Professional installers should also be
able to tell you about any local codes that may apply to your installation.
THRU-THE-WALL INSTALLATION
Many models may be installed through a wall so long as the unit’s side vents are
not blocked or covered in any way. See page 17, In-wall Installation max. depth.
COOLING SIZING GUIDE
Area to be conditioned
in sq. ft.Cooling Btu
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1600 25000
1600 - 1900 28000
1900 - 2700 36000
WHICH AIR CONDITIONER
IS RIGHT FOR YOU?
Window TypeAir Conditioner
Single/double hungWindow, portable,
ductless
SliderWindow*, portable,
ductless
CasementPortable, ductless
Vertical CasementPortable, ductless
Environmentally friendly R-410AYYYY
Energy saver switchYYYY
EARTH FRIENDLY
RoHS compliantYY——
Washable, antimicrobial air lterYYYY
Optional carbon lterYY——
Check lter reminderYYYY
HEALTH
Superior fresh air intake/stale air exhaustAll except SQAll except EQ08
EntryGard™ anti-intrustion protectionYYYY
Insect barrierAll except SQAll except EQ08——
SAFETY
Slideout chassisYYAll except CP05Y
Power cord directionLeft or rightLeft or rightLeft or rightLeft or right
(Opens up or down) (Opens left to right, or right to left)
Awning Hopper Casement
(Cranks out) (Opens in) (Cranks out)
5
Kühl Construction.
For over 125 years, Friedrichproducts have been renownedfor their commercial-grade,built-to-last design.
Advanced engineering, high-end materials and components,and rigorous product testingare just a few examples ofFriedrich's commitment toquality. When designing Kühl,our engineers challengedconvention to develop the verybest window air conditioner onthe market.
Kühl incorporates high-endmaterials like heavy-gauge
galvanized steel, ried
copper tubing, and high-tech
aluminum ns.
Kühl also uses the mostdurable components to extendthe life of your air conditioner,including fully -enclosed fanmotors that seal out dirt, and
powerful, energy-efcient
compressors, which make Kühlas tough an air conditioner aswe’ve ever built.
Kühl Quiet.
Kühl Comfort.
KÜHL.
BUILT TOUGH FOR THE
MOST DEMANDING
APPLICATIONS
Kühl has been engineered for quiet
operation. Materials have been
chosen because of their soundabsorption properties and every
moving part has been braced and
insulated. For example, extra thick
rubber grommets absorb vibration
and reduce noise inside, while
steel inner walls and extra dense
insulation block outdoor noise.
Rugged hardboard side panels help
reduce noise and keep out light. The
unique air path is more streamlined,
drawing air through the sides, away
from moving parts. And our larger
discharge vents allow for smoother
airow, delivering maximum
conditioned air quietly.
The most comfortable
temperature is the one you never
notice. Kühl uses multiple builtin environmental sensors to
more accurately monitor indoor
and outdoor temperatures so
that it can maintain your ideal
settings.
Kühl+ models have the ability
to cool or heat as needed so
units can operate year-round.
And, like the most advanced
central systems, Kühl+
automatically switches between
air conditioning and heating
functions to maintain the desired
comfort level. You won't have to
lift a nger.
Plus, Kühl's air ow systems are
tested for powerful and precise
air distribution which means
faster cooling when you need it
most.
6
7
CAPABLE
SMART GRID
Control
Deep Red
COLOR YOUR
WORLD
with one of six Kühl colors.
Change your Kühl's appearance
to complement your color scheme
or to make a bold statement.
Built-in
controls
Wi-Fi
control
Wireless
thermostat
SIMPLE OPERATION
Turn the unit on, select ‘MODE’ and make simple up/down
temperature adjustments either at the control panel or with
included remote.
BUILT-IN 7 DAY SCHEDULES
Kühl units include two 7-day energy management schedules which
can be accessed and selected from the unit’s controls.
The '
Residential
temperature temporarily during the hours when most people are
away at work and lower them again prior to the time when most
people will return home.
The '
Commercial
after typical working hours and on weekends when commercial
spaces are typically unoccupied.
CUSTOM 7-DAY SCHEDULE (
separately
Create up to 5 custom programs that you can use to operate your
Kühl air conditioner for maximum comfort and efficiency. Each
7-day program allows up to 4 setting changes per day.
WIRELESS CONTROL
Control Kühl units with a smartphone, tablet or computer. You
can even group units to operate as a single system for central
air-like control.
KWW WIRELESS THERMOSTAT (
separately.
Connect up to 8 Kühl units* with 1 KWW thermostat. Each unit
requires 1 communication module (KCM). KWW thermostat ships
with 1 KCM module.
’ schedule causes Kühl to raise the room
' schedule tells the unit to raise temperatures
requires optional accessory sold
)
requires optional accessory sold
)
Control Kühl with a
smartphone, tablet or
computer.
FriedrichLink
®
Wi-Fi
allows monitoring
and control of one or
all of your Kühl air
conditioners remotely.
Connect Kühl* to a
Building Management
System.
Kühl’s streamlined modern design inNeutral Gray can blend in with any décor.
Or coordinate a look that complements yourspace by using any of the six colored frontcovers.
Neutral Gray
(STANDARD)
Pink Diamond Cobalt Blue Classic Beige Black Onyx Designer White
Kühl units* can be connected to a Building Management System
with a KCM module (1 for each Kühl unit) and a KJD. KEG may
also be required depending on Building Management System.
Contact your Friedrich sales representative for more information.
*Wireless thermostat and Building Management Systems are not compatible Kühl SQ and EQ models.
Smart Grid Capable
Kühl is the rst room air conditioner that can tie into a power company’s smart grid.
A grid is a network that brings electricity from power stations to
consumers. New technologies allow power companies to adjust
electrical loads of residential users based on their specic needs
- this is called a ‘smart grid’. Smart grid helps consumers to be
better informed about their electricity usage and allows electric
utility companies to serve customer demand in the most efcient
way.
For example, during a hot summer afternoon when AC units are
running at full capacity, the smart grid can send information to
recalibrate other loads, which helps to alleviate stress on the
system as a whole.
Source: SGIC (Smart Grid Information Clearinghouse)
8
9
Window Air Conditioners
Ultra Premium Line
Experience the control and convenience of a central air conditioning
system in ways you never thought possible. Control Kühl units via
FriedrichLink
®
.
If you have a
room that is too
cold in winter, too
hot in summer,
adding a Kühl+
model is the
perfect solution.
You’ll nd more
options, features
and ways to
customize your
cooling experience
than you ever
thought possible
in a window air
conditioning
solution.
Full LCD display shows
MODE, FAN SPEED,
SET TEMPERATURE
and SCHEDULE. Adjust
TEMPERATURE and FAN
SPEEDS, set AUTO MODE
and turn the SCHEDULE
ON/OFF.
FITS WINDOWS FROM
22" TO 42" WIDE
Neutral Gray
(STANDARD)
FITS WINDOWS FROM
27 3/8" TO 42" WIDE
Neutral Gray
(STANDARD)
COOL
COOL
COOL & HEAT
COOL & HEAT
®
Kühl
5200-9600 Btu
Up to 11.2 EER
Kühl®+
Electric Heat
COOLING
7900 Btu
Up to 11.2 EER
ELECTRIC HEAT
4000 Btu
Kühl®
8000-36000 Btu
Up to 11.5 EER
Kühl®+
Electric Heat
COOLING
12000-36000 Btu
Up to 11.3 EER
ELECTRIC HEAT
8900-17300 Btu
Kühl®+
Heat Pump
COOLING
9500-24000 Btu
Up to 10.4 EER
HEATING
8000-22000 Btu
Up to 2.7 COP
10
11
Kühl® Features
Kühl® Accessories
Comfort & Convenience
• Convenient control from your
smartphone, tablet or computer via
FriedrichLink® (required accessory
sold separately)
• 2 ready-to-go 7-day energy
management programs
• Create customizable, 7-day
schedules with up to 4 setting
changes per day (requires accessory,
sold separately)
• 24-hour timer
• Up to 4 cooling and 4 fan-only speeds
on select models†
• Automatic fan speed adjustment
• Auto-changeover from cool to
heat; heat to cool to maintain set
temperature (Kuhl+ models except
EQ08)
• 8-way air ow control
• Temperature readout can display set
temperature and room temperature
• Control panel lockout (ON/OFF)
• LCD panel auto dims if not in use
• Nightlight mode
Superior Sound Reduction
Technology
• Steel inner wall and extra dense
insulation materials block outdoor
noise
• Vibration isolating design and
components diminish traditional
operating noise
• Precision engineering maximizes
air ow while delivering ultraquiet
operation
* Feature not available on Kühl SQ and EQ models. **Nut driver not required for Kühl SQ and EQ models.
†Kuhl SQ and SL models have 3 fan speeds. Kuhl+ models have 3 fan speeds cooling and heating.
Superior Filtration
• Superior fresh air intake and stale air
exhaust vent*
• Washable, antimicrobial air lter
• Check lter reminder
• Optional premium lter when used
in conjunction with standard lter
provides superior air ltration with
ratings as high as MERV 6, while also
adsorbing odors and reducing ozone
and VOCs
• Totally enclosed commercial
grade fan motor runs at a lower
temperature to prevent overheating
and is double-mounted for added
stability and reduced wear
• Durable base pan and steel inner
walls
• Unit’s structural integrity allows it to
be removed, cleaned and maintained
outside of its sleeve
• Aluminum rear grille protects the
outdoor coil from damaging debris
and vandalism
• Aluminum end plates will not
contribute to rust-stained building
exteriors
• Scratch-resistant cabinet
• High-tech aluminum ns with ried
copper tubing are more efcient and
less prone to corrosion
• Heavy-duty installation hardware
lasts longer and provides a superior
barrier from the outside elements
Installation Features
• Install in a window or thru-the-wall
• Slideout chassis for more permanent
installation and easier access for
maintenance
• Includes heavy duty window
installation hardware (optional
accessory on Kühl+ models sold
separately)
• Rugged hardboard side panels or
(heavy duty side curtains on SQ and
EQ models) for a more permanent
installation
• Power cord can run either left or right
• Firm grip handles for easier chassis
installation and removal
• Front cover attaches easily and
securely. Nut driver included**.
Earth Friendly
• Smart Grid capable
• Auto Fan mode saves money by
conserving energy
• ENERGY STAR® qualied models,
including heat pumps
• Environmentally-friendly R-410A
refrigerant used in all models
• Recyclable packaging
• RoHS compliant
Safety & Security Features
• EntryGard™ anti-intrusion protectionsteel retaining wire secures the
chassis to the sleeve to deter ‘kick-in’
intrusion
• Powercord leakage current protected
• Insect barrier*
• Protective rear grille
FRIEDRICHLINK® WIFI ADAPTER
Wi-Fi Adapter Accessory connects to unit to allow for
remote wireless access and programming from a computer,
tablet or mobile device.
ModelKit No.
N SeriesK WIFI
PREMIUM CARBON FILTERS
Remove odors and VOCs (volatile organic compounds).
Achieve up to a MERV 6 rating when used with standard
lter. 3 pk.
ModelKit No.
SQ and EQ
SS, ES and YS
SM, EM and YM
SL, EL and YL
KWCFQ
KWCFS
KWCFM
KWCFL
WINDOW MOUNTING KITS: KÜHL+
Heavy duty kits required for installation of these Kühl+
models in a window.
Heat/Cool ModelsKit No.
EQ 08N 11B*KWIKQA
ES12N33B, ES16N33, YS10N10B and Y S12N3 3B.KWIKSA
EM18N34, EM24N34A and YM18N34B.KWIKMA
EL36N35B and YL24N35B.KWIKLA
*EQ08N11B window kit KWIKQ does not include window brackets.
COLORED FRONT COVERS
Colored front cover kits available in six colors.
Deep Red Cobalt Blue
Classic Beige Designer White
Black Onyx Pink Diamond
COLOR
Deep Red
ModelKit No.
SQ and EQ
SS, ES and YS
SM, EM an d YM
SL, EL and YL
DRAIN KIT
DRAIN KIT
Drain tube eld installed to the bottom
Drain tube eld installed to the bottom
on the base pan.
on the base pan.
ModelKit No.
ModelKit No.
All Kühl Series ModelsDC2
All Kühl Series ModelsDC2
KWREDQA KWBLUQA KWBGEQA K WWHTQA KW BLKQA K WPNKQA
KWREDSA KW BLUSA KWBGESA KW WHTSA KWBLKSA KWPNKSA
KWREDMA KWBLUMA K WBGEMA KWWHTMA KWBLKMA KWPNKMA
KWREDLA KW BLULA KWBGEL A KWWHTLA KWBLKLA KWPNKLA
Cobalt
Blue
Classic
Beige
Designer
WIRELESS THERMOSTAT- KWW
Wireless thermostat for control of Kühl
units*. One thermostat can control up
to 8 Kühl units. Additional units require
1 KCM communication module per unit.
KWW Thermostat ships with 1 KCM
Communication Module.
White
Black
Onyx
Pink
Diamond
COMMUNICATION MODULE- KCM
Communicates with KWW thermostat or
building management system.
*Not compatible with Kühl SQ and EQ
KWIKQ KWIKS, KWIKM, KWIKL
12
models.
13
CHILL
®
Window Air Conditioners
SLEEK
DESIGN
and outstanding efciency.
Available in a range of capacities
with convenience features for
carefree cooling and heating.
Premium Line
Sleek white design and energy efficient operation, including heat/cool models.
Our efcient
line of room airconditioners withprogrammablecontrols forconvenientoperation
Money Saver®
feature saves
energy by cycling
the fan with the
compressor
AUTO AIR SWEEP SWING
LOUVERS FOR EVEN COOLING
THROUGHOUT THE ROOM.
Comfort & Convenience
• 24-hour timer
• Auto air sweep swing louvers*
provide more even air distribution
• 3 cooling speeds, plus 3 fan-only
settings; 2 cooling speeds, 2 heating
speeds, plus fan-only setting on
Chill+
• Ultraquiet operation
• 4-way air ow control
• Auto-restart saves settings if power
is interrupted
Earth Friendly
• ENERGY STAR® qualied models
• Money Saver® setting saves money
by operating the fan only when
cooling
Health
• Washable, antimicrobial air lter
• Check lter alert
• Stale air exhaust
Installation Features
• Slideout chassis*
• Install in window or thru-wall**
• Standard installation hardware
• Expandable side curtains
• Power cord can run either left or
right out of the side of the unit
front*
Safety & Security Features
• EntryGard™ anti-intrusion protection
Select MODE, FAN SPEED,
MONEY SAVER
SWEEP, adjust TEMPERATURE
and set the TIMER.
CP05
Select MODE, FAN SPEED,
MONEY SAVER
TEMPERATURE and set the
TIMER.
®
, AUTO AIR
®
, adjust
FITS WINDOWS FROM
20 1/8" TO 36" WIDE
COOL
FITS WINDOWS FROM
20 1/8" TO 42" WIDE
COOL
COOL & HEAT
®
Chill
5450 Btu
10.7 EER
®
Chill
6000-23500 Btu
Up to 11.3 EER
Chill®+
Electric Heat
COOLING
8000-23500 Btu
Up to 9.8 EER
ELECTRIC HEAT
3850-12000 Btu
* Feature not available on CP05. ** CP05 has a xed chassis and is for window installation only.
* Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F.
Friedrich room air conditioners are designed to operate in outdoor temperatures from 60°
F to 115° F.
Kühl+ Heat Pump heating information (shown in red) indicates heat pump performance. Kühl+ and Chill+ Electric Heat heating information
(shown in red) indicates electric heat strip per formance. For Kühl+ Heat Pump electric heating per formance refer to corresponding Kühl+
Electric Heat model.
®
As an ENERGY STAR
®
guidelines for energy efciency.
STA R
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY
The consumer- through the AHAM Room Air Conditioner Certication Program- can be certain that the AHAM Certication Seal accurately
states the unit’s cooling and heating capacity rating, the amperes and the energy ef ciency ratio.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
Moisture
Removal-
Pints/HR CFM Sleeve
Net
Wt.
lbs.
Ship
Wt.
lbs.
Sleeve
Height
INCHES
Q
14
P1†12"
P614”18
P715"23
P816
P916
S15
M17
L20
15
15
3
Width
INCHES
½"
19 ¾"
½"
18
3
/8
”20
5
/8
"
7
/8
”26"26
7
/8
”26"30
15
/16
" 25
/16
"29"
15
/16
" 25
/16
"29"
/16"
28"35 ½”
Depth
with Front
INCHES
3
21
/8
15"5"
7
/8
¾”
21
7
/8
3
/8
ShellDepth
to Louvers
INCHES
"
”8
”10
”10
16
Minimum
Extension
Into Room*
INCHES
½"
8
5
3
1
/8
”
4
8
¾"
1
/4
1
/4
¾"
8
¾"
8
½"
4
"
5
”
5
5
5 ¾”
5
½"
½"
½"
½"
½"
½"
¾”
3
/8
”18
Minimum
Extension
Outside
INCHES
*
10
¾"
10
¾"
11"20
12”25 ¼”39"15 ¼" 23
5
16
/8
"
19
½"
15
16
/16
”27
15
16
/16
”27
15
/16
”29
Window Width
INCHES
Minimum** Maximum Height Width Max. Depth
22"42"
1
20
/8
”36"NOT FOR THRU-WALL15 1/4”22 1/4”17 1/2”
1
/8
”36"14
½
26
26 ½"
3
3
7
/8
/8
/8
42"17
"
42"17
"42"16
"42"18
”42"20
In-wall Installation
Finished Hole
¾”
14
1
/8
” 18
1
/8
” 26 ¼"9 "21 1/2”29 1/2”29”
1
/8
” 26 ¼"9 “21 1/2”33”28 7/8”
3
/16”
26
3
/16”
26
3
/8
" 28 ¼"15
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
† Sleeve P1 does not have In- wall hole dimensions, as these units are xed chassis and should not be installed In-wall.
NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.
Model
Circuit Rating
Breaker or
T-D Fus e
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
CP05G10A125V-15 A5 -15P6 1/2
CP0 6G10A, CP08G10A, CP10G10A,
CP12G10A and CP15G10A. EP 08G11A.
All SQ MODEL S. EQ08N11B. SS08N10B,
125V - 15A5- 5P6
SS10N10B, SS12N10B and SS14N10A.
YS10N10B. SM15N10B.
CP18G30A250V - 15A6 - 15P4 1/2
SS12N30B and SS16N30, SM18N30 and
SM21N30B. SL24N30B.
CP24G30A.
EP12G33A, EP18G33A and EP24G33A.
SM24N30A. SL 28N30B. ES12N3 3B and
ES16N33. YS12N33B.
SL36N30B. EM18N34, EM24N34 A and
EL36N35B. YM18N34B and YL 24N35B.
A solid-side wall sleeve allows for installation in thick exterior walls where the
installation of room air units with side vents would affect performance and may
even void the warranty.
THRU-THE-WALL MODELS
ROOM AIR CONDITIONER
Blocked side vents restrict air ow.
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can
be installed in thicker walls. Sleeve
can be positioned ush with exterior
wall.
WallMaster
Sleeve size
Applications
OVERVIEW
Perfect t for Fedder’s 27” sleevesY—
Top-mounted controlsY—
Electronic controlsYY
Programmable timer24 hr.24 hr.
Remote controlYY
Auto-restart when power is
interrupted
Smart Fan auto adjusting fanY—
Upward angled air dischargeY—
COMFORT & CONVENIENCE
Air ow direction control4-way6-way
Fan speeds33
Steel inner wall and extra dense
insulation
Fits 27” sleevesFits sleeves from
RESIDENTIAL OR
LIGHT COMMERCIAL
®
Y Y
YSteel inner wall
24 1/2” to 27”
RESIDENTIAL OR
LIGHT COMMERCIAL
Uni-Fit
®
WALL UNITS IN
TWO SIZES.
Upgrade your old inefcient units
with Wallmaster
the-wall air conditioners.
The best option for deep wall installations
Energy efcient solid-side air conditioners, heat pumps and electric heat models.
WallMaster® ts existing Fedders sleeves.
Sleeve Dimensions
Height (inches)16 3/416 3/416 3/4
Width (inches)272727
Depth (inches)16 3/416 3/419 3/4
®
and Uni-Fit® thru-
Friedrich
WSE Sleeve
Fedders
A Sleeve
Fedders
B Sleeve*
Or with minimum intrusion into the
room.
Vibration-isolating design and
components
TECHNOLOGY
Superior airflow designY—
SOUND REDUCTION
ENERGY STAR® modelsYY
Environmentally friendly R-410AYY
EARTH
FRIENDLY
Energy saver switchYY
Washable, antimicrobial air lterYY
HEALTH
Stale air exhaust—Y
EntryGard™ anti-intrusion
protection
Insect barrierY—
SAFETY
Slideout chassisYY
Power cord directionLeftRight
Concealed power cord optionY—
Internal drain kit optionY—
Bafe adapter kit (for installation in
INSTALLATION
Fedders ‘B’ sleeves)
Condensate drain kitY—
YY
Y—
Y—
Chassis requires WSE sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a bafe kit. See BAK
accessory under accessories.
Uni-Fit® installs in many existing sleeves.
(51S
Fedders/
Emerson/
Friedrich
WSE
19 3/4
Emer-
son/
Fedders
1516 7/817 1/8
GE/
Hot-
pointWhirlpool
or 23
Sleeve
Dimensions
Height
(inches)
Width
(inches)
Depth
(inches)
NOTE: Chassis requires USC sleeve for new installations (sold and shipped separately)
Friedrich
USC Sleeve Amana
15 1/215 5/816 7/816 3/415 3/415 5/816 1/215 1/4
25 7/82625 3/42726 3/42625 7/825 1/2
16 3/416 7/818 5/816 3/4 or
Carrier
Series)
White-Westing-
house/Frigidaire/
16, 17 1/2 or 22
Carrier (52F
Series)
18
19
Thru-the-wall Air Conditioners
WallMaster® Features
WallMaster®. A perfect fit in Friedrich and competitor’s 27” sleeves.
Commercial grade quality unit is ideal for installation in new construction,
retrots and remodels.
Perfect t in 27"
wall sleeves,
including Fedders A
and B* sleeves.
FITS SLEEVES
16 3/4" HIGH X 27" WIDE
Comfort & Convenience
• Easy-to-reach, top mount controls
• Remote control
• 24-hour timer
• Smart Fan auto-adjusts fan speed to
maintain desired temperature
• 3-speed fan
• Auto restart
• Electronic defrost control
• Reversible louver allows a second
airow option
Energy Efficiency
• Money Saver® setting saves money by
operating the fan only when needed
• ENERGY STAR® qualied models
• R-410A refrigerant
Health and IAQ
• Washable, antimicrobial lter
Safety & Security
Durability & Quality
• Rotary compressors provide quiet,
dependable performance
• Premium aluminum exterior grille
• Dense blower insulation
• Ried copper tubing
• Impact resistant front cover
• High tech ns with sine wave lanced
louvers increase energy efciency
by increasing surface area for heat
exchange
Accessories
• WSE sleeve, ships with inside and
outside weather panel and standard
grille
• AG architectural grille for use with
WSE sleeve
• Bafe adapter kit for use with deep
sleeve installations
• Drain kit for condensate disposal
• Internal drain kit for new
construction applications where
condensate drain system is built-in
Ried
copper
tubing
Sine wave lanced
louvers
WallMaster®
8000-15600 Btu
Up to 10.4 EER
WallMaster
Electric Heat
COOLING
9800-15600 Btu
Up to 9.8 EER
ELECTRIC HEAT
9100-11000 Btu
WallMaster
Heat Pump
COOLING
9000-12000 Btu
Up to 9.8 EER
HEATING
7500-9350 Btu
Up to 2.6 COP
®
®
COOL
Select MODE, FAN SPEED,
adjust TEMPERATURE and set
the TIMER.
NOTE: Chassis requires WSE sleeve for new installations (sold and shipped separately)
WSE wall sleeve ships
with weather panels
and grille.
Sleeve is shown at right with
standard galvanized steel
inner panel, painted steel
outer panel and standard
grille
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
Black plastic for use on existing sleeves without any grille.
IMPORTANT:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a bafe
adapter should be used.
Trim ring
US= 3 3/8”, UE= 2 7/8”
IMPORTANT:
US chassis w/front fully installed into USC sleeve
extends into room 3 3/8”. UE chassis w/front fully
installed into USC sleeve extends into room 2
7
/8”. 1” gap on sides and 1/2” gap at top can be
covered by two-piece trim ring that ts over the
chassis front
WallMaster Heat Pump heating information (shown inred) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: C hange-over f rom heat pump opera tion to resistan ce
operation on models indicated is automatic at a preset outside ambient temperature
of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat starts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Plug Face/ Circuit Rating
Circuit
WallMaster
Model Number
WS08C10D, WS10C10D,
WS12C10D
WS10C30D, WS12C30D,
WS16C3 0
WE10C33D, WE12C33D,
WE16C33, WY09C33D, WY12C33
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
As an ENERGY STAR
models meet the ENERGY STAR
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity
cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
®
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR®
®
guidelines for energy efciency.
®
Uni-Fit
Model Number
US08D10B, UE08D11B
US10D10B, US12D10B
US10D30B, US12D30B,
US14D30B
UE10D33B, UE12D33B250V - 20A6 - 20P4
Rating
Breaker
or T-D Fuse
125V - 15A5 - 15P6
250V - 15A6 - 15P4
Plug
Face
(NEMA#)
Power
Cord
Length
(ft.)
Appearance
Wall
Outlet
Model
WallMaster
WSE Sleeve18" 2 7 1/4" 18"
Chassis15 3/4" 26 1/2" 21"
®
Uni-Fit
USC Sleeve17 7/ 8" 28" 19 1/4"
US Chassis17 1/4" 27" 22 1/4”
UE Chassis17" 27 1/4" 22”
Carton Dimensions
INCHES
Height W i d th Depth
®
25
NOTE: Unit not shown installed.Vent hoses must vent outdoors.
FASTER
COOLING &
HIGHER ENERGY
EFFICIENCY
Friedrich portables move easily
from room-to-room to provide
fast cooling and heating comfort.
Dual hose design for up to 40% faster cooling or
heating and increased energy efficiency.
Portable Air Conditioner and Heat Pump
Comfort & Convenience
AIR CONDITIONER
• 3-IN-1 SYSTEM: Air conditioner,
dehumidier and fan
• Dual hoses for closed loop cooling
and exhaust functions for up to 40%
faster, more efcient cooling
• Self-evaporative condensate
system means no bucket to empty
• Condensate overow protection-
the unit will automatically shut off
if tank should become full. The unit
can be drained through the water
outlet drain
• 24-hour timer
• 3 fan speeds
• Washable, antimicrobial air lter
• Auto restart after power outage
• Stores easily in most closets
HEAT PUMP
• 4-IN-1 SYSTEM: Air conditioner,
heater, dehumidier and fan
• Dual hoses for closed loop cooling
and exhaust functions for up to 40%
faster, more efcient cooling
• Built-in drain pump to remove
condensate (drain hose included)
• Self-evaporative condensate
system means no bucket to empty
• Condensate overow protection-
the unit will automatically shut off
if tank should become full. The unit
can be drained through the water
outlet drain
• 24-hour timer
• 3 fan speeds
• Washable, antimicrobial air lter
• Auto restart after power outage
• Stores easily in most closets
Superior dual-hose design
DUAL HOSE
Only indoor air is
conditioned and
returned into the room.
Indoor air is not vented
outside and wasted.
The room is cooled
up to 40% faster
with greater energy
efciency.
SINGLE HOSE
Relies on air ‘leakage’
around doors and
windows to make up
for air volume lost as
indoor air is exhausted
outside.
Inefcient-both indoor
air and removed heat
are exhausted.
Air Conditioner
3-IN-1 SYSTEM:
Air conditioner,
dehumidier and fan.
Heat Pump
4-IN-1 SYSTEM:
Air conditioner, heater,
dehumidier and fan.
Heat pump operation is
more efcient than other
portables that rely on
resistance heat.
Both systems remove up to
72 pts./day when used as a
dehumidier.
ZoneAire
®
Air Conditioner
COOLING
9300 and 11600 Btu
Up to 9.4 EER
Heat pump
COOLING
13500 Btu
9.5 EER
HEATING
10700 Btu
2.8 CO P
Use remote to select
MODE, FAN SPEED,
adjust TEMPERATURE
and set the TIMER.
Ideal for areas with added
heat loads and for cooling
emergencies
INSTALLS QUICKLY AND EASILY
WITH THE INCLUDED WINDOW
INSTALLATION KIT.
26
COOL
COOL & HEAT
NOTE: Air conditioners will provide cooling at outdoor temperatures down to 41� F and
heat pumps will provide heating at outdoor temperatures down to 14� F with single hose installation.
27
Features/Installation/Specifications
LISTED
LISTED
Ideal Applications
• Supplemental or emergency
cooling or heating anywhere
• Temporary cooling in computer rooms
• Guard buildings
• Construction trailers/RVs
• Workshops and garages
• Home ofces
• Dorm rooms
• Bedrooms, attics and basements
• Sunrooms/enclosed patios
Installation Kit
INSTALLATION KIT- Dual intake and exhaust
hoses. Flexible, heavy duty intake/exhaust
hoses extend from 24” to 60”. The hoses can
be vented through a window or through a wall
opening to the outside.
Energy Efciency RatingEER9.48.89.5
Coefcient of PerformanceCOP——2.8
Air MovementCFM212235250
Moisture RemovalPts/hr.5.06.06.0
SPECIFICATIONS
Refrigerant TypeR-410A
Power SupplyVolts115
Rated Current
Watts98913181421/1120
Dimensions (Inches)W x H x D19 1/2 x 33 1/2 x 15 1/2
Weight (Net/Shipping)Lbs. 71/89 72/9078/95
Carton Dimensions (Inches)W x H x D20 7/8 x 43 1/8 x 16 3/4
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
NOTE: Air conditioners will provide cooling at outdoor temperatures down to 41� F and
heat pumps will provide heating at outdoor temperatures down to 14� F with single hose installation.
Cooling Amps10.811.510.8
Heating Amps——10.8
Fits HORIZONTAL or VERTICAL WINDOWS
WINDOW OPENING:
Minimum: 26"*
* Window slider kit can be trimmed to t a smaller
opening.
Maximum: 46"
Model
P09B,
P12B,
PH14B
Circuit Rating
Breaker or T-D
Fuse
125V - 15A5 - 15P6 ft.
(NEMA#)
Plug
Face
Wall Outlet
Appearance
Power
cord
length
Extreme A/C for Hazardous Conditions
Hazardgard® is specically designed to cool living quarters, storage areas and
other enclosures situated in hazardous locations, where specic volatile ammable
liquids or gases are handled or used within enclosed containers or systems.
Hazardgard meets T4 temperature classication which means unit surface temperatures will not rise above 135° C/275° F. (note: 50/60Hz model listed as T4A
for surface temperatures to 120° C/248° F). Operates at low ambient conditions
without freezing at outdoor ambient temperatures as low as 7° C/45° F. Tolerates
higher outdoor temperatures up to 55° C /130° F.
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70
(National Electric Code)
ARTICLE 501 ARTICLE 505
Class I, Div. 2, Group A and Group B Class I, Zone 2, Group IIC
Class I, Div. 2, Group B Class I, Zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C Class I, Zone 2, Group IIB
Class I, Div. 2, Group D Class I, Zone 2, Group IIA
Hazardgard
60 Hertz models
North America
14000 to 24000 Btu
Up to 9.7 EER
50 Hertz models
International
19100 to 19500 Btu
Up to 9.0 EER
50-60 Hertz model
International-North America
50 Hertz 60 Hertz
21000/20500 Btu 24000/23700
8.1/8.5 EER 8.8/8.5 EER
®
Equipment is certified in accordance with ANSI/UL 484 and SASO 2681
28
29
Applications
LISTED
Features
Specifications
Built to perform in the
harshest environments
• Offshore oil rigs, on-shore oil company
ofces and reneries
• Petrochemical sites and propane ll-up
stations
• Paint and varnish storage or processing
plants
• Grain alcohol processors or storage sites
• Plant areas using strong solvents or
chemicals
• Munitions plants or armories
• PVC or plastics plants and processing points
• Recycling plants
• Furniture renishing/stripping workshops
• Fertilizer plants
• Ofce complexes where methane is a by-
product
• Hazardous materials storage
• Container labs
• For analyzer houses/shelters
Friedrich air conditioners can be found in some of
the world’s toughest locations. Oil companies rely
on us to cool offshore oil rigs in the most extreme
conditions.
• Permanent split capacitor motor
• Hermetically sealed refrigeration system
• Environmentally sealed on/off switch and gold plated contacts in
thermostat for corrosion resistance
• Solid-state control relays for compressor and fan operation
• Hot gas bypass allows the air conditioner to operate at low ambient
conditions without freezing at outdoor temperatures as low as 45° F (7°C)
• Hermetically sealed reciprocating compressor is cooled during the
refrigeration cycle, which allows the unit to tolerate
higher outdoor temperatures up to 130˚ F (55°C)
• Larger, commercial grade, enclosed fan motor with
hermetically sealed overload for arc-free operation.
Totally enclosed to assure efcient operation under
adverse electrical conditions
• Unit utilizes eld supplied, direct-wired, 15-amp circuit
with time-delay fuse that will tolerate current surge
without tripping the breaker
• 22-gauge, G60 steel air conditioner cabinet is powder
coated for corrosion protection and to withstand years of
hard use
• High density EPS foam insulation for thermal resistance
and sound control
• Heavy duty hexacomb packaging resists damage during shipment and is
environmentally friendly
COILS COATED FOR CORROSION RESISTANCE
MODEL SH24M20
• ElectroFin® 5-stage, immersion ecoat process on 100% of metallic
surfaces on the outdoor coil provides outstanding corrosion resistance
protection in coastal or corrosive environments
ELECTROFIN BENEFITS:
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-
DS2, HCI Gas
• CID A-A-52474A (GSA)
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-P-53084 (ME)-TACOM Approval
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120 cycles)
• ASTM B117-G85 Modied Salt Spray (Fog) Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for Lockheed Martin)
MODELS SH15M30A, SH20M30A, SH20M50A
• Diamonblue Advanced Corrosion Protection® on the
outdoor coil protects the coil against deterioration and
extends the life of the unit especially in coastal or
corrosive environments
Due to continuing engineering research and technology, specications are subject to change without notice. Manufactured under U.S. Design
Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. (55°C) MAXIMUM
TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
For global applications, Hazardgard cooling capacities are tested in a certied laboratory at moderate (T1*) and hot (T3*) climate conditions in
accordance with SASO (Saudi Arabian Standards Organization) Standard 2681. SASO Standard 2681 is adopted from ISO Standard 5151 for testing
and rating for performance of non-ducted air conditioners and heat pumps.
* Capacity and efciency values at each climate conditions are available upon request.
Sleeve Dimensions Drawing
(A)
Max.
Wall
Depth
Junction
Box
Front
SIDE VIEW
NOTE: Hazardgard unit
must be hard-wired.
30
31
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 800.541.6645
www.friedrich.com
Retail_Room_Air_Conditioners_Brochure_2014 (10-13) Printed in USA
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.