Thermozone AD Corinte A/E - ADCS
2
Fig 1
150
150
45
100
44
134
40
65
140
140
40
65
150
44
100
134
45
150
Min 180
Min 180
Ø20(2x)
Ø20(2x)
M6
M6
Ø30x2
Ø30x2
Upper part of the unit seen from above.
Bottom part of the unit seen from above.
Opening
Connection hatch
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg3.png)
Thermozone AD Corinte A/E - ADCS
3
1
2
80
60
1
2
60
80
3
Ø22 Cu
Fig 2
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg4.png)
Thermozone AD Corinte A/E - ADCS
4
1
2
3
4
5
6
2
6
7
Fig 3
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg5.png)
Thermozone AD Corinte A/E - ADCS
5
Fig 4
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg6.png)
Thermozone AD Corinte A/E - ADCS
6
180
35
35
80
40
Ø12
25
Fig 6
Fig 7
360
243
Ø22
Ø10
15
5
10
Fig 5
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg7.png)
Thermozone AD Corinte A/E - ADCS
7
1700/2200
1670/2170
75
Ø30
Ø20 (3x)
Left connection
Right connection
Wall
Fig 8
Fig 9
50
75
376
ADCS A/E: Min 220 mm
ADCS W: Min 180 mm
ADCS A/E: Min 220 mm
ADCS W: Min 180 mm
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg8.png)
Thermozone AD Corinte A/E - ADCS
8
Fig 10
SIRe
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bg9.png)
Thermozone AD Corinte A/E - ADCS
9
A
B C
A
C
B
ADCEH
Ø8
Ø12 (2x)
}
2 alternatives for securing at the top.
1
Ø8 for securing at the air curtain.
2
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bga.png)
Thermozone AD Corinte A/E - ADCS
10
Regulations alternatives
This aircurtain is supplied with an intelligent
and well designed low voltage control system
SIRe which can be customized for each unique application and environment. The control
system is pre-installed in the aircurtain with
an integrated control card. SIRe is supplied
pre-programmed with quick-release connections and is very easy to use and install. There
are three different levels with different functionality to choose from, Basic, Competent
or Advanced.
Type RSK-nr Description HxWxD
[mm]
L
[m]
SIReB Control system Basic
SIReAC Control system Competent
SIReAA Control system Advanced
SIReRTX 673 09 22 External room temperature sensor 70x33x23
SIReUR* 673 09 21 Kit for recessed installation 114x70x50
SIReWTA
Clamp-on sensor
SIReCJ4 Joint piece for two pcs. RJ11 (4p/4c)
SIReCJ6 Joint piece for two pcs. RJ11 (6p/6c)
SIReCC603 673 09 23 Modular cable RJ11 (6p/6c) 3
SIReCC605 673 09 24 Modular cable RJ11 (6p/6c) 5
SIReCC610 673 09 25 Modular cable RJ11 (6p/6c) 10
SIReCC615 673 09 26 Modular cable RJ11 (6p/6c) 15
SIReCC403 673 09 27 Modular cable RJ11 (4p/4c) 3
SIReCC405 673 09 28 Modular cable RJ11 (4p/4c) 5
SIReCC410 673 09 29 Modular cable RJ11 (4p/4c) 10
SIReCC415 673 09 30 Modular cable RJ11 (4p/4c) 15
![](/html/6f/6f5c/6f5c91470c4950d1bdb97d589daf9d3b3ee67e4febd9ba46da75b47b54003198/bgb.png)
Thermozone AD Corinte A/E - ADCS
11
Wiring diagrams
Internal
ADCS A
ADCSA
SIReB1
230V~
Actuator
230V~
Transformer
230V
200V
170V
145V
120V
100V
N
Black
Blue
Supply
230V~
C2
C1
ROOM
Internal
sensor
Motor
protection
Transformer
230V
200V
170V
145V
120V
100V
N
Yellow
Orange
Red
Brown
Black
Green
Blue
LN