Frico Thermozone AC 500 Original Instructions Manual

Original instructions
Thermozone AC 500
SE
NL
.... 4
.... 15
GB
DE
.... 7
.... 17
FR
PL
.... 9
.... 19
NO
RU
.... 22
FI
.... 13
AC 501: c/c 986
AC 502: c/c 1506
Thermozone AC 500
c - c 50
986
785
Thermozone
AC 501: c/c 1030 AC 502: c/c 1550
AC 501: c/c 519
AC 502: c/c 1038
AC 500
515
+15° -15°
Fig 1
+30°
0°
Fig 2
Fig 3
Thermozone
AC 501
136
15o15
min 215
o
2
Wiring diagram
Level 1
Thermozone AC 500
Level 2
LL
L
23
LL
L
23
LL
L
23
LL
L
23
3
Thermozone AC 500
Technical specifications | Thermozone AC 500 without heat 1
Type Airflow
[m3/h]
AC501 5200 63
AC502 7700 65
Sound level [dB(A)]
Voltage [V]
230V~/ 400V3~
230V~/ 400V3~
Amperage [A]
3,1/1,8 1030 65
4,1/2,7 1550 93
Length [mm]
Protection class AC 500 without heat: (IP24), splash-proof design. CE compliant.
Weight [kg]
4
Montage- och bruksanvisning
Allmänna anvisningar
Läs noga igenom denna bruksanvisning före installation och användning. Spara sedan manualen för framtida bruk.
Garantin gäller endast om Frico montage­och bruksanvisning har följts och produkten använts såsom däri är beskrivet.
Användningsområde
Frico Thermozone AC 500 är ett luftridåaggregat avsedda att användas som skydd för industri- och lagerportar mellan 3,0 upp till 3,5 meters höjd. Ridåernas effektivitet är beroende på hur stor belastningen är i den aktuella porten. Thermozone AC500 innehåller inget värmebatteri och monteras över eller vid sidan av porten.
Kapslingsklass: IP24, sköljtätt utförande.
Funktion
Luften tas in från apparatens ovansida och blåses med hög hastighet genom ett bikakegitter, vilket resulterar i en kraftig och väldefinierad laminär luftstråle. Detta för att skärma av portöppningen så effektivt som möjligt och minimera värme/kylläckage genom porten. Ridån hindrar också insekter, damm och avgaser från att komma in i lokalen. Upphängningskonsolerna gör det möjligt att rikta agregaten och därmed luftstrålen beroende på belastningen mot porten. Denna möjlighet finns också med monterade luftriktare. Med varvtalsomkopplaren justeras lufthastigheten så att skyddet av porten blir optimalt.
Observera att undertryck i lokalen försämrar lufridåns effektivitet väsentligt. Ventilationen bör därför vara balanserad!
Montering
Thermozonen installeras normalt på insidan av porten, så nära öppningens kant som möjligt. När ett kylrum skall skyddas monteras luftridåerna på den varma sida. Apparaterna skall monteras tätt ihop, så att det inte uppstår glapp mellan luftströmmarna.
a) Montage hängande i balk eller tak
Montera en kraftig balk ovanför och längs med portöppningen. Luftridåerna kan också monteras i taket men det kan då vara svart att komma åt kopplingsboxarna.
Montera upphängninskonsulerna på apparatens gavlar. (Fig1.)
Kontrollmätt c-c avståndet mellan konsolernas upphängningshål. Mätt upp och borra hål (för 10 mm skruv) på motsvarande ställen i balken/taket.
Häng upp aggregaten ett efter ett. Justera ev.apparaten så att den vinklas ut mot porten. (Fig.2).
Montera fläktregleringen på lämpligt ställe på väggen.
Utför den elektriska anslutningen
b) Montage mot vägg
Montera upphängningskonsolerna på apparatens baksida (Fig.3).
Kontrollmätt c-c avståndet mellan konsolernas upphängningshåll. Mät upp och borra hål (10 mm skruv) på motsva­rande ställen i väggen.
Häng upp aggregaten en efter en. Justera ev. apparaten så att den vinklas ut mot port.
Montera fläktregleringen på lämpligt ställe på väggen.
Utför den elektriska anslutningen.
Elinstallation
Installationen, som ska föregås av en allpolig brytare med ett brytavstånd om minst 3 mm, ska utföras av behörig installatör och i enlighet med gällande föreskrifter.
Det finns olika alternativ för reglering av
motorernas varvtal, se kopplingsschemor.
Använda genomföringar måste säkerställa
det aktuella kravet på kapslingsklass!
lnjustering av luftridån
Luftstrålens riktning och hastighet ska justeras med hänsyn till belastningen på porten. Tryckkrafter påverkar luftströmmen så att den böjer av inåt i lokalen (vid
Thermozone AC 500
uppvärmd lokal och kall uteluft). Luftströmmen bör därför riktas utåt för att stå emot belastningen.
Observera att om det är undertryck i lokalen försämras luftridåns effektivitet väsentligt. Ventilationen bör vara balanserad!
1. lnjustering av luftström
Se till att de båda ledskenorna är parallella. Be­roende på belastning vinklas aggregaten mot portöppningen. Erfarenhetsmässigt är 10-15° utåt en lämplig vinkel. I de fall aggregatet inte kan vin­klas finns möjlighet att använda luftriktarna. När ett kylrum ska skyddas monteras luftridåerna på den varma sidan och med luftströmmen riktad 10-15° mot den varma sidan.
Grundinställning varvtal
Ställ in varvtalet så att lufthastigheten 1 meter över golvet blir 3-4 m/s.
Observera att utblåsriktning och varvtal kan behöva finjusteras ytterligare beroende på portens belastning.
Skötsel
Fläktarnas motorer och övriga komponenter behöver inget underhåll annat än rengöring vid behov, dock minst en gång per år.
Säkerhet
Säkerställ att området kring apparatens insugs- och utblåsgaller hålls fritt från material som kan hindra luftströmmen
genom apparaten!
Denna produkt är inte avsedd att användas av barn eller personer med nedsatt fysisk eller mental förmåga eller brist på erfarenhet och kunskap, om inte anvisningar angående produktens användning har getts av person med ansvar för deras säkerhet eller att denna person övervakar handhavandet. Barn skall hållas under uppsikt så att de inte kan leka med produkten.
6
Thermozone AC 500
Instruction for installation and use
GB
General Instructions
Read these instructions carefully before installation and use. Keep this manual for future reference.
The guarantee is only valid if the units are used in the manner intended by the manufacturer and in accordance with the Frico mounting and operating instructions.
Are of use
The Frico Thermozone AC 500 is an air curtain intended to be installed above industrial- and warehouse doors of 3,0 —6,0 meters height. The air curtains efficiency is depending on the load of the door.
Protection class IP24.
Function
The air intake is positioned at the top of the unit and blown with high velocity through a honeycomb lattice which results in a strong and laminar air stream. The air curtain consists of 2 or 3 powerful diagonal fans which are mounted in an air stream channel. The housing is made of galvanised steel covered with grey enamel. The air stream protects the opening and minimises hot/cold leakage through the open door. Insects, dust and exhaust fumes are also prevented from entering the building. The deflectors that are fitted on both sides of the outlet can be used to direct the air stream up to ±15°. It is always better to tilt the complete unit if possible. The airflow will be controlled by a fan regulator, placed in a separate box.
NB! under-pressure in the building will significantly reduce the effectiveness of the air curtain. Ventilation ought to be balanced.
Mounting
Thermozone air curtains are in general mounted on the inside of the door and as close to the opening as possible. When they are supposed to protect a cold store they should be mounted on the warm side of the opening. To cover the entire opening the units must be placed as close as possible to each other. If possible tilt the units towards the opening.
Suspension brackets are included, with which the air curtain can be hung from overhead beams / ceiling or with which they can be screwed to the wall.
A) Mounting on overhead beams or in the ceiling
1. A heavy-duty beam is to be mounted in a suitable position above and along the door opening. The air curtains can also be mounted to the ceiling, however it may then be difficulties to access the connection box.
2. Fit the suspension brackets on the ends of the air curtain. (Fig 1.)
3. Check the c-c distance between the suspension bracket’s fixing holes. Measure and drill holes (for 10 mm bolts) in the appropriate positions on the beam/ceiling
4. Lift up the air curtains one by one and bolt in position. Tilt the unit outwards against the door and tighten the screws. (Fig 2.)
5. Mount the fan regulator in an appropriate place on the wall.
6. Carry out the electrical connection.
B) Mounting against a wall
1. Fit the suspension brackets on the rear side
of the air curtain. (fig 3).
2. Check the c-c distance between the
suspension bracket’s fixing holes. Measure
and drill holes (for 10 mm bolts) in the
appropriate positions on the wall.
3. Lift up the air curtains one by one and
hang the key holes of the brackets on the
bolts. Secure using 6 mm screws so that the
units cannot be unhooked again. Tilt the
unit outwards against the door and tighten
the bolts.
4. Mount the fan regulator in an appropriate
place on the wall.
5. Carry out the electrical connection.
Electrical installation
The electrical installation must be carried out according to existing regulations and by an authorised electrician. The unit must be preceded by an all-pole switch. There are many different ways to regulate the fan speed.
7
GB
Thermozone AC 500
The connections will be found in the wiring diagrams. Use appropriate conduit to secure the protection class.
Adjusting the air curtain.
The direction of the air stream and the velocity of the air is to be adjusted depending on the situation in the opening. Wind­pressure and under-pressure depending on different temperature have a negative effect on air curtains and wants to bend the air stream inwards the opening. To compensate for that the air stream is to be directed outwards.
NB! under-pressure in the building will significantly reduce the effectiveness of the air curtain. Ventilation ought to be balanced.
1. Air stream
Make sure the air directors are placed in a parallel way. Depending on the situation in the opening tilt the unit outwards against the door. Found by experience the recommendation is 10-15° towards the opening. When the air curtains are used to protect a cold storage rooms they should be mounted on the warm side and with the air stream directed 10-15° towards the warmer side.
Security
Ensure that the area around the intake and
exhaust grille is kept free from material
which could prevent the air to flow through
the unit!
This appliance is not intended for use by
persons (including children) with reduced
physical or mental capabilities, or lack of
experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should
be supervised to ensure that they do not
play with the appliance.
2. Air flow
Adjust the fan speed so that the velocity of the air stream will be 3-4 m/s 1 m above the floor.
The above given recommendations are based on normal conditions. Further adjustments are depending on the situation in the opening In some areas the direction and the speed of the air stream might need to be adjusted depending of the season of the year.
Maintenance
The fans are driven by maintenance free motors. The air curtains only require regular inspection and cleaning at least once a year.