Frico Soloclim SC17, Soloclim SC22, SoloclimSC23DCI Original Instructions Manual

Soloclim
Original instructions
Installation
2
Soloclim
This unit complies with the following European Directives:
• Low voltage 2014/35/EU
• Electro-magnetic compatibility 2014/30/EU
• Use restrictions of hazardous substances in electrical and electronic equipment 2011/65/EC (RoHS2)
• Waste electrical and electronic equipment 2002/96/EC (WEEE).
• Energy consumption indication on the labels of energy­related products 2010/30/EU
Warning
- It indicates actions that require caution and a suitable preparation.
Prohibition
- Refers to prohibited actions.
Compliance Safety pictograms
3
Soloclim
General
General warnings 4
Fundamental safety rules 4
Description 5
Storage 5
Handling 6
Shipping dimensions and weight 6
Supplied components 6
Unit parts 7
Installation
Installation mode 8
Choosing the position of the unit 8
Assembling the unit 9
Condensation drain predisposition 10
Assembling air ducts and external shutters 10
Mounting the appliance on the bracket 11
Electrical connection 12
High/low installation configuration 13
Setting cool only or heat only modes 14
Brightness regulation 14
Touch-screen display key lock 14
Hotel function 14
Anomaly diagnosis 14
Troubleshooting
Periodic Maintenance 16
Troubleshooting 17
Technical specifications 18
4
Soloclim
General
After unpacking, check that the contents are intact and
that all parts are included. If not, contact the agent who sold the appliance to you.
The appliance must be installed by an authorised
company.Once the work is done, it must issue a declaration of conformity to the client in compliance with current Regulations and with indications on the instruction manual supplied with the appliance.
These appliances have been designed for conditioning
and/or heating rooms and they must be destined solely for this purpose compatibly with their performance characteristics.
The manufacturer refuses any contractual or extra-
contractual responsibilities for damage caused to people, animals or things resulting from incorrect installation, adjustment, maintenance or improper use.
In the event of water leaks, turn off the main switch and
close the water taps.
Immediately call the Technical Assistance Service
or other qualified personnel and do not intervene personally on the appliance.
The use of products that use of electricity and water
requires the observation of some fundamental safety rules such as:
The unit can be used by children over the age of
8, and by people with reduced physical, sensory or mental capabilities, or with no experience or necessary knowledge, as long as they remain under surveillance or after they have received instructions on the safe use of
the unit and have understood the dangers involved. Children must not play with the appliance. The cleaning and maintenance that must be performed
by the user must not be carried out by children without
supervision.
It is forbidden to modify the safety or adjustment
devices or adjust without authorisation and indications
of the manufacturer.
It is forbidden to pull out or twist the electric cables
coming out of the unit, even when disconnected from
the mains power supply.
General
General warnings
A temperature that is too high or too low is harmful to
health and is an unnecessary waste of energy.
Avoid prolonged direct contact with the air flow.
Do not leave the room closed for long. Periodically open
the windows to ensure proper ventilation.
This instruction booklet is an integral part of the
appliance and therefore it must be kept with care and must ALWAYS accompany the appliance even when the latter is transferred to another owner or user or transferred to another system. If it gets damaged or lost, please request another copy to the local Technical Assistance Service.
Repairs or maintenance must be performed by the
Technical Assistance Service or by qualified personnel in accordance with this manual. Do not modify or intervene on the appliance as this could create dangerous situations and the manufacturer will not be responsible for any damage caused.
The appliance is declared to have a degree of protection
IPX0, therefore it cannot be installed outdoors or in laundry rooms.
Fundamental safety rules
It is forbidden to introduce objects or substances
through the aspiration grills and the air outflow.
It is forbidden to open the access doors to the internal
parts of the appliance without having turned off the main switch first.
It is forbidden to dispose of, or leave in the reach of
children, the packaging materials which could become a source of danger.
It is forbidden to climb onto the appliance and/or to
place any type of object on top of it.
5
Soloclim
General
The air conditioning unit Soloclim is the new solution that represents a significant step towards reducing the aesthetic impact of air conditioners. With a depth of just 16 centimetres, Soloclim is the most compact and least bulky of the category. Its aesthetic impact is therefore minimal, both inside and out.
Optimised Capacities
The conditioning capacities of Soloclim have been optimised so as to obtain the right temperature for the best level of comfort and, therefore, less consumption and less noise. Thanks to the careful choice of sound insulation materials, the noise is similar to that of a standard wall split unit and consumption is drastically contained thanks to the new direct current fan.
162 millimetre holes
An important choice not only for the design, but also for a significant installation advantage: easier to find drilling tools, no need for professional drills, even less aesthetic encumbrance.
BLDC inverter technology
We have perfected the Inverter technology to offer the best in terms of acoustic comfort (noise) and performance: reduction of consumptions, maintenance of the best temperature level and humidity level in the room. Thanks to the use of the cutting edge BLDC (brushless direct current) Inverter regulation, vibrations have been completely eliminated and acoustic emissions have been lowered to exceptional levels. Both ventilation motors are BLDC to reduce consumption still further and make flow adjustment more precise.
The packing is made of suitable material and carried out by expert personnel. All units are checked and tested and are delivered complete and in perfect conditions, however please perform the following instructions to check the quality of shipping services:
- upon receipt, check if the box is damaged.If that is the case, accept the goods with reservations and keep photographic evidence of any damage found
- unpack and check the contents against the packing list.
- check that none of the parts have been damaged during shipment.In case of damage, report it to the shipping company within 3 days of receipt by registered letter with return receipt and attaching photographic documentation. A copy should also be sent by fax to the MANUFACTURER. No notice of damage will be accepted after 3 days from delivery.
Description
Storage
The energy consumption is extremely reduced thanks to absorption values falling down under 300 W in the case of partial load. At the nominal cooling power of 2.35 kW Soloclim has an EER equal to 3.24 (10 HP) and 3.22 (12 HP) which allows an energy efficiency ratio of “A+” to be obtained, this is the cutting edge in the sector of monobloc climate control systems with fixed installation.
Easy to install
Soloclim can be installed on any perimeter wall either low or high. Everything needed for installation (template, support bracket, hole pipes and external grids), excluding the drill, is included in the box.
Folding external grids
Soloclim is equipped with folding grids activated by inlet and outlet air.They open when the unit is working and close when it's turned off. Better indoor comfort, less dust, noise and pollution, less maintenance and even less outdoor visibility.
Remote control and touch-screen display
In addition to the remote control, the touch-screen display on the unit enables the setting of any function.There's even a "lock" mode to avoid any improper use. With a simple action on the touch screen display, the "heating" function can be deactivated: the appliance will then operate in "cooling" only, without the need for the condensate discharge pipe. The orientation of the air flaps can also be adjusted by simply pressing one key.Receipt and unpacking
Keep the packing at least through the warranty
period, in case you need to ship the air-conditioner to the service centre for repair. Dispose of the packing materials in compliance with current regulations on waste disposal.
Store the box in a closed environment protected from atmospheric agents and isolate it from the floor using planks or pallets.
Do not turn the carton upside down
6
Soloclim
General
Packaging SC17 SC22 SC23DCI
Weight Kg 47,6 48 48,5
L mm 110 0 1110 1110
H mm 660 660 660
P mm 260 260 260
The supply comprises of the parts listed in the following table. Before assembly, please check that they are all at hand.
A External grids for air inlet and outlet with springs and chains
(2 pcs)
B Screws and plugs kit (6 pcs)
C Bracket for wall mounting
D User manual
E Remote control
F Paper template for holes.
G CR2025 3V remote control battery
H Wall inlet pipes (2 pcs)
I Energy efficiency label
N Installation manual
O Counter-flange for internal wall
The unit is packed singularly in a cardboard box. Boxes can either be carried singularly by hand by two operators or loaded on a cart, for a maximum of three units.w
Handling must be performed by qualified personnel,
with specific tools and with equipment suitable for the weight of the appliance.
The appliance is unbalanced on the right (compressor
side)
During transportation, the appliance must be kept in
vertical position.
Handling
Shipping dimensions and weight
Supplied components
Loading...
+ 13 hidden pages