Frico Infraflex Series, Infraflex IHA15WF, Infraflex IHA15SF, Infraflex IHA20WF, Infraflex IHA20SF Assembly And Operating Instructions Manual

Infraflex IHA15WF/SF IHA20WF/SF
GB
.... 3
DE
.... 5
Infraflex IHA15/20
2
Infraflex IHA15/20
ASSEMBLY AND OPERATING INSTRUCTIONS
GB
SAFETY INSTRUCTIONS
• Only connect the device to a properly installed grounding type receptacle. If you encounter problems with the connection, check that the fuse is not being overloaded by other electric power consumers. It is advisable to use a separate fuse for the radiant heater. It may be necessary to use a slow-blowing type C fuse.
• Only connect devices to alternating current voltage as stated on the type plate!
• Never touch live parts! Risk of fatal injury!
• Never operate the device with wet hands! Risk of fatal injury!
• Never operate the device if the device or lead are damaged. Risk of injury!
• Do not store or use readily flammable substances or sprays in the vicinity of the device when in operation. Risk of fire!
• Do not use the device in a readily flammable atmosphere (e.g. in the vicinity of combustible gases or spray cans)! Risk of explosion and fire!
• Caution! Do not insert foreign objects into the device openings! Risk of injury (electric shock) and damage to the device!
• Caution! Do not look into the light for prolonged periods of time!
• Caution: The device/protective grill becomes very hot during operation! For this reason, install the device such it cannot be touched accidentally. Risk of burning!
• Never attempt to adjust the pivoting angle when the device is in operation! Risk of burning!
Allow the device to cool down first before
adjusting it.
• Children and persons under the influence of medication should only be allowed to use the device under supervision! Ensure that children cannot play with electrical devices!
• The socket must be accessible at all times
so that the mains plug can be disconnected quickly.
• The operating instructions belong to the device and must be kept in a safe place! In case of a change of owner, the instructions must be supplied along with the device!
• Allow the device to cool down before removing it!
• No objects whatsoever such as garlands and streamers should be fastened to the radiant heater. Risk of fire!
LOCATION
• The radiant heater is equipped with a frame for ceiling or wall mounting and must be secured in the 2kW version (BHSF20-x) at least 2.1 m above the ground. The installation height for the 1.5kW version is at least 1.8 m above the ground.
• The device may only be commissioned if it has been mounted level.
• The distance between the protective grill and combustible objects and other buildings must be at least 150 cm.
• Do not expose the device to rain or other moisture!
• Since the device emits radiant heat, make sure that no items, such as furniture, are located between the device and the persons or objects to be warmed!
POWER CORD
• The power cord must not come into contact with heated parts of the device!
• Never remove the plug from the socket by pulling on the cord! Never move the device by pulling on the cord or carry the device by the cord!
• Do not wind the cord around the device! Do not operate the device with the cord wound up!
• Do not clamp the cord, or pull it over sharp edges!
INSTALLATION
• The device may only be installed and connected by qualified professionals. The installation must be isolated prior to
3
GB
Infraflex IHA15/20
commencing any electrical work!
Risk of fire!
• The device is secured and held in the ceiling cut-out by means of four retaining clamps. The edge of the ceiling cut-out must have a sufficient load-bearing capacity for securing the radiant heater.
• The ceiling cut-out must have the dimensions 305 to 310 mm x 510 to 580 mm.
• When installing the device, no supporting elements such as joists, rafters or roof battens should be damaged.
• Under no circumstances should the cavity above the radiant heater be filled with insulating material or other materials.
• Sufficient air exchange for heat dissipation must be ensured in the cavity above the radiant heater.
• The device is equipped with a mains lead fitted with a grounding type plug without a switch. The device must be switched on and off by means of a locally installed switch.
Only commission the device after it has
been fully installed.
COMMISSIONING
• After switching on the device when commissioning it for the first time as well as after a lengthy period of non-use, it is possible that odors may be emitted for a short while.
• Improper repairs can result in considerable risks for the user!
TECHNICAL DATA
Color: White or silver Casing: Sheet steel, varnished Cord length: 2.9 m with grounding type plug Switching on/off: Via separate light switch to be installed (locally) by the electrician Application: Indoors
Technical Data
Connection/fuse: 230/240 Volt (50/60 Hz) with 16 Amp B or C (= slow-blowing fuse) Output: 1500 Watt / 2000 Watt Infrared tube: HANA ‘Gold Tube’ Guaranteed service life: 5000 hours (approx. 10-15 years with average use) Type of protection: IP 20
Dimensions (W x D x H): 600 mm x 325 mm x 110 mm Weight: 4.55 kg
Installation depth: min. 450 mm Cut-out length/width: 305 to 310mm x 510 to 580 mm Ceiling panel/panel thickness: max. 15 mm
CLEANING
• First disconnect the device from the mains.
• Once cooled down, it is possible to wipe down the frame dry.
• Do not touch quartz bars with fingers, as doing so can leave marks and cause them to fail.
• The reflector should be cleaned at regular intervals from outside with a paint brush.
• Do not use abrasive or caustic detergents!
• Never immerse the device in water! Risk of fatal injury!
CUSTOMER SERVICE
• Only authorized professionals are permitted to perform repairs to the device!
Important! Unprofessional tampering
invalidates all warranty entitlement.
4
Main offi ce
Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se
For latest updated information and information about your local contact: www.frico.se
20170630 HH