Frico ICF 20, ICF 55 User Manual

Code. 5.471.084.040
.... 9
SE
.... 14
DE
.... 13
FR
.... 11
.... 12
GB
.... xx
PL
.... 10
NO
.... xx
DE
.... 16
PL
.... 15
RU
ICF 20/55
2
ICF20/55
Type Height
[mm]
ø
[mm]
Weight
[kg] ICF20 545 1422 6,2 ICF55 545 1422 6,2
Dimension
˜ 2,3 m
A
84 mm
8 kg
= 32 kg
• 2,7 m
3
ICF20/55
1
2
5
3
4
Installation
6
4
ICF20/55
7
9
10
IPX5
ø < 6 mm
8
5
ICF20/55
15
14
13
16
11
IPX5
12
L
N
52
1
(see ) )
19
L
N
52
1
L
N
52
1
6
ICF20/55
17
18
7
ICF20/55
19
21
20
Maintenance
Wiring diagrams ICF20/55
~
1234
L
~~
25
°C
M
~
Black
Blue
Red
LN
UU
12
N
L
LL
RF
230V~
NN
1
N
5678
N
L
230V~
N
L
230V~
CAR15
ICF20/55
25
°C
M
~
Black
Blue
Red
1
ICF20/55
25
°C
M
~
Black
Blue
Red
1
ICF20/55
ICF20/55
ICF20/55
ICF20/55
ICF20/55PE1/2,5
RE5
(L)
25
1
25
1
25
1
25
1
L
N
21
N
L
230V~
ICF20/55
CFR1R
25
1
5
N
Givare golv/ Sensor floor
Givare tak/ Sensor ceiling
Vidarekoppling/ Relay connection
Anslutning för reversering/ Connection for reverse rotation
Switch
8
ICF20/55
ICF 20/55
12
GB
General Instructions
Read these instructions carefully before installation and use. Keep this manual for future reference.
The guarantee is only valid if the units are used in the manner intended by the manufacturer and in accordance with the Frico mounting and operating instructions.
Areas of use
Roof fans are chiefly used to even out the temperature in premises with high ceilings. The warm air that collects under the ceiling is pressed down so that it can heat the occupied areas underneath. Warm air escape via the ceiling are thereby reduced. This form of air mixing also has a quicker heating effect on cold goods, makes for better drying, and reduces the risk of cold irradiation. Enclosure class ICF20: IPX0 Enclosure class ICF55: IPX5
Placement
The fans should be placed symmetrically in the premises where they can provide optimum temperature spread. Make sure the fans are always installed where there is no risk to people or of contact with objects from the rotating blades. Nor should they be placed where they blow air directly on people. Generally fan speed should be regulated so that they don’t cause draughts.
Fan installation and electrical connection
See fig. 1-18.
Max. surrounding temperature is +40 °C.
The roof fan(s) should only be wired by a competent electrician and in accordance with the latest edition of IEE wiring regulations.
Service and maintenance
See fig. 19-21.
ICF20/55 is basically maintenance free, but should be checked on a regular basis.
Important! Check the hanging brackets to avoid the risk of the fan falling down.
Before cleaning the unit or carrying out maintenance operations, turn the main switch off and remove the plug from the power supply.
When several units are controlled with a common control device the fan speed could differ from one unit to another. In most cases these differences will disappear when the fans have been running for some time (about a week). Another reason could be that the lower protective cover is squeezed to tight to the fan, adjust the coves if necessary.
Safety
This appliance is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or a lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by an individual responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Specifications for the power supply must correspond to the electrical data on data plate A (fig. 2).
Assembly and operating instructions
2013-11-11 HH/SÅ/SÄ
Main offi ce
Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se
For latest updated information and information about your local contact: www.frico.se