![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg2.png)
Dimensions and connections
Vertical ACC E/W
AC Corinte
Details of ACC W
Intake
Doorway
Outlet
Upper part
of the unit
seen from
above.
Bottom part
of the unit
seen from
above.
A
[mm]
ACC10 1000
ACC15 1500
ACC20 2000
ACC25 2500
ACC30 3000
Connection dimensions,
inside thread
3/4”
Ø
ACC WL X
ACC10WH X
ACC15WH X
ACC20WH X
ACC25WH X
ACC30WH X
DN20
1”
DN25
2
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg3.png)
AC Corinte
Dimensions and connections
Details of ACC W
120
50
Horizontal ACC E/W
3
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg4.png)
To open
AC Corinte
Fig. 1: To open
Mounting
Fig. 2: Securing in the wall or ceiling.
Note! The air curtain
must be secured in
the wall or ceiling.
4
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg5.png)
AC Corinte
Minimum distance
200
Fig. 3 Minimum distance, ACC E. Fig. 4 Minimum distance, ACC W.
ACC Wallbracket
180
31
185
26
Ø8 M8 (2x)
264
2
40
50 39
Ø12 (2x)
5
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg6.png)
Accessories - AC Corinte E/W
Type Description
CK01E Control kit Electric level 1 (CB32N, RTI2)
CK02E Control kit Electric level 2 (CB32N, RTI2,
MDC)
CK03GD Control kit level 3 (ADEA, ADEAIS, ADEAEB,
ADEAGD1)
CK01W Control kit Water level 1 (CB30N, T10)
CK02W Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N Control box (A/W)
CB32N Control box (E)
ADEA Air curtain control
ADEAEB External control board, IP55
ADEAIS External room sensor, IP30
ADEAGD1 Additional control board to acheive ADEA
and BMS functionality
RTI2 2-step room thermostat, IP44
RTI2V 2-step room thermostat, knob, IP44
T10 Room thermostat, IP30
KRT1900 Room thermostat, IP55
MDC Magnetic door contact with time relay, IP44
AGB304 Door contact, IP44
KUR Digital time switch, IP55
CBT Electronic timer, IP44
VR20 Valve set, DN 20 mm
VR25 Valve set, DN 25 mm
TVV20 2-way control valve, DN 20 mm
TVV25 2-way control valve, DN 25 mm
SD20 Actuator
ACCWBP Wall bracket polished bright annealed*
ACCWBB Wall bracket brushed stainless steel*
ACCWBMP Wall bracket mirror polished stainless steel*
AXP300 Collision protection
*) For ACC 1-1,5 m: order 2 pcs, for ACC 2-3 m: order 3 pcs.
More information about accessories on pages 29-31 and 60-62.
AC Corinte
6
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg7.png)
AC Corinte
Wiring diagrams AC Corinte
Electric regulations options
Level 1
2+PE
I + II = III
III
K2
K1
C
C
F3
50º
C
~
M
1
~
11
~
MM
C
K3
F2
F4
F5
Trafo
6x0,5mm² 4x0,5mm²
2×(2+PE)
AC Corinte E
6x0,5mm²
CB32N
LLL
123
2+PE
4x0,5mm²
RTI2
LN
80º
78
6
5
3
N123456
L
C3
C2
C7
C6
C1
50º
40º
230V
200V
170V
140V
120V
LNPE L1 L2L3 PEC6 C7
control
Supply heat
230V~ 400V3~
400V3~ Heat 400V3~ Heat
2×230V~ Motor and control
AC Corinte E
10
789
234561
0 0
CB32N
230V~
Fuse
~
M
1
Thermozone AC Corinte E
Supply fan Supply heater
230V~
C°
234567LN1
Hi Lo
RTI2
7
![](/html/93/9372/9372f83b6140642535935c136bdbf0bb758ef6cf47715c5f5db199b66cbe97ac/bg8.png)
Wiring diagrams AC Corinte
Electric regulations options
Level 2
AC Corinte
I + II = III
III
M
230V~
C°
234567LN1
Hi Lo
RTI2
Supply heater
LLL
123
K2
K3
LN
K1
F2
80º
C
LNPE L1 L2L3 PEC6 C7
230V~ 400V3~
32
31 34
22
21 24
12
11 14
DC DC
NL
Door
contact
control
230V~
53 6 78
C3
C2
C7
C6
C1
Supply heat
F4
50º
C
F3
50º
C
~
1
F5
40º
C
230V
200V
170V
140V
Trafo
120V
MDC
10 11
789
~
11
~
MM
~
M
1
Thermozone AC Corinte E
Fuse
N 123456
L
234561
0 0
CB32N
230V~
RTI2
Supply fan
2+PE
2+PE
MDC
2x0,5mm²
Door
contact
6x0,5mm² 6x0,5mm²
2×(2+PE)
AC Corinte E
5x0,5mm² 4x0,5mm²
2+PE
CB32N
6x0,5mm²
400V3~ Heat 400V3~ Heat
AC Corinte E
230V~ Motor and control
8