NOTES:
Please read entire owners manual before operation.
WARNING
The product is marked with this symbol when it is required to refer to
the instruction manual to protect the operator from safety hazards.
IMPORTANT: DO NOT EXPOSE TO RAIN OR MOISTURE TO
PREVENT FIRE AND SHOCK HAZARD
POWER INPUT: 90-135 OR 180-240VAC 50/60 HZ.
THE INPUT RANGE IS AUTOSELECT BY THE UNIT.
GROUNDING/EARTHING: THIS UNIT MUST BE CONNECTED
TO A STANDARD 3 PIN POWER SOURCE WHICH IS
GROUNDED THROUGH NORMAL WIRING.
AUTHORIZED SERVICE PERSONNEL ONLY: OPENING THIS
UNIT VOIDS ALL WARRANTIES. SERVICE PERSONNEL WAIT
10 MINUTES AFTER REMOVING POWER BEFORE OPENING.
DO NOT BLOCK AIR VENTS DURING OPERATION
ONLY CHARGE NICAD AND NiMH RECHARGEABLE BATTERIES
STUDY THIS COMPLETE MANUAL BEFORE OPERATION. THIS
UNIT INCORPORATES PARTS SUCH AS SWITCHES AND RELAYS THAT ARE LIKELY TO PRODUCE ARCS AND SPARKS;
THEREFORE WHEN OPERATING IN A GARAGE OR SIMILAR
LOCATION, LOCATE THE UNIT IN A ROOM OR ENCLOSURE
PROVIDED FOR THIS PURPOSE IF APPLICABLE.
CLASS I COMPLIANT DEVICE
WATER INGRESS CLASSIFICATION -IXPO
THIS UNITS WAS DESIGNED AND MANUFACTURED TO BE
COMPLIANT UNDER:
BS-EN-60335-1 HOUSEHOLD SAFETY OF ELECTRONIC
EQUIPMENT
BS-EN-60335-2-29 BATTERY CHARGERS
BS-EN-50081-1 EMISSION REQUIREMENT
BS-EN-55104:95 IMMUNITY REQUIREMENT
EMC DIRECTIVE 89.336/EEC//93/68/EEC
MANUFACTURED IN USA
SAFETY - READ BEFORE GOING FURTHER
![](/html/8e/8e8a/8e8a5bf296af2f0d135df223604cdad20dc53d208dd3e322f3a3a58886a30137/bg3.png)
page 10 page 3
1. SETUP
Connect power cord and turn on the charger via the switch at the
rear of the unit. The charger will flash through a self test to verify
proper operation.
2. AUTO FAST CHARGE
Insert a battery into the top NP1 port, Brick adapter or front BP-90
port. Charging will begin automatically indicated by the flashing
yellow “Charge” LED.
IMPORTANT: BP-90 front port bypasses the top battery connector.
When charging is complete, the green “Ready” LED will come on.
The battery may remain on the charger until needed. The M1000
will supply a maintenance charge to keep the battery topped off until
ready for use.
Note 1: If the red “10V” LED flashes, this indicates a low voltage
situation and the “Rescue” program should be engaged. See
below.
Note 2: If the red “Fault” LED comes on, the battery is faulty or has
anomalous characteristics.
3. DISCHARGE
To engage the discharge function, press the “Discharge” button.
The orange LED will flash indicating that discharge is in progress. At
the end of the discharge cycle and a 15 minute rest period, the unit
will automatically switch to the charge cycle.
4. RESCUE
The M1000 has a unique Rescue mode designed to restore abused,
low capacity, or over-discharged batteries. If a battery begins to
show signs of poor performance, or low voltage is indicated, the
battery rescue mode should be engaged by pressing the “Rescue”
button. While engaged, the orange “Rescue” LED will flash. The
rescue process could take a long as 20 hours, so it is recommended
to run it overnight or over a weekend.
NOTES:
OPERATION