@T =100
@T =25
@T =100
RRM
SK12 THRU
Features
Mechanical Data
·
Case: Molded
·
Terminals: Plated leads solderable per
MIL-STD-750,Method 2026 guaranteed
·
Polarity: Color band dentes cathode end
·
Mounting Position: Any
·
Making: Type Number
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified
Single phase,half wave,60Hz,resistive or inductive load
For capacitive load derate current by 20%
Maximum Recurrent Peak Reverse Voltage V
Maximum DC Blocking Voltage VDC
Average Rectified Output Current
Peak Forward Surge Current 8.3ms Single half
sine-wave superimposed on rated load (JEDEC
Method)
I
FSM
30
Forward Voltage @IF=1.0A VFM
Peak Reverse Current ℃
IR
At Rated DC Blocking Voltage
Typical Junction Capacitance
Operating Temperature Range T
Storage Temperature Range
1.Pulse Test with PW=300usec,1%Duty Cycle.
2.Mounted on P.C.Board with 5.0 mm²(0.13mm thick)copper pad areas.
Low Power Loss,High Efficiency
·
Ideally Suited for Automatic Assembly
·
Plastic Case Material has UL Flammability
Classification Rating 94V-
SMB/DO-214AA
F(AV)
I
L
0.083(2.11)
0.075(1.91)
0.096(2.44)
0.084(2.13)
0.057(1.45)
0.033(0.85)
0.010(0.25)
0.004(0.1)
0.187(4.75)
0.163(4.15)
0.217(5.50)
0.197(5.00)
0.154(3.90)
0.130(3.30)
0.012(0.300)
0.004(0.100)
0.008(0.20)
0.004(0.10)
Rating for fusing (t <8.3ms)
I2t
Typical Thermal Resistance per leg
A
A
I2t
STG
3.73
2
A s
/W

FIG.1 FORWARD CURRENT DERATING CURVE
FIG.2TYPICAL INSTANTANEOUS FORWARD CHRACTERISTIC
1.0
CURRENT (A)
.75
.50
SINGLEPHASEHALFWAVE60Hz
RESISTIVEORINDUCTIVELOAD
.25
P. C . B M O U N T E D
X
X
0.2"( 5.0 5.0mm)
ON0.2
COPPERPADAREAS
0
0 75 100 125 150 17525 50
LEAD TEMPERATURE( C)
o
AVERAGE FORWARD RECTIFIED
FIG.3MAXIMUM NON-REPETITIVEPEAKFORWARD SURGE CURRENT
(A)
30
25
20
15
10
10
(A)
URRENT
1.0
C
ARD
FORW
0.1
ANEOUS
NT
A
0.01
INST
,
F
I
(uA)
SK18 - SK110
SK125
SK115-SK120
A
T =25ºC
SK15 - SK16
SK12 - SK14
I Pulse Width = 300 sFµ
0 0.4 0.8 1.2
V , INSTANTANEOUSFWD VOLTAGE (V)
F
FIG.4TYPICALREVERSE CHRACTERISTIC
5
10
4
10
3
10
2
10
1
10
T =125 C
J
O
T=75C
J
O
5
0
PEAK FORWARD SURGE CURRENT
0
10
110100
REVERSE CURRENT
NO. OF CYCLE AT 60Hz
-1
10
-2
10
FIG.5 MOUNTING PAD LAYOUT
O
T=25C
J
20
PERCENT OF RATED PEAK REVERSE VOLTAGE ,%
40 60 80 100

Important Notice and Disclaimer
Reproducing and modifying information of the document is prohibited without permission
•
from DIYI.
DIYI reserves the right to make changes to this document and its products and
•
specifications at any time without notice. Customers should obtain and confirm the
latest product information and specifications before final design, purchase or use.
DIYI disclaims any and all liability arising out of the application or use of
•
any product including damages incidentally and consequentially occurred.
DIYI does not assume any and all implied warranties, including warranties of fitness for
•
particular purpose, non-infringement and merchantability.
Applications shown on the herein document are examples of standard use and
•
operation. Customers are responsible in comprehending the suitable use in particular
applications.
DIYI makes no representation or warranty that such applications will be suitable for the
specified use without further testing or modification.
The products shown herein are not designed and authorized for equipments requiring high
•
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling th products for use in such applications
do so at their own risk and agree to fully indemnify DIYI for any damages resulting from such
improper use or sale.
Since DIYI uses lot number as the tracking base, please provide the lot number for tracking
•
when complaining.
e se