The products described in this manual can fail in a variety of modes due to misuse, age, or malfunction and is not
designed or intended for used in systems requiring fail-safe performance, including life safety systems. Systems
with the products must be designed to prevent personal injury and property damage during product operation
and in the event of product failure.
Warning! Verify power is OFF before connecting or disconnecting the interface or RF cables.
Warranty Information
FreeWave Technologies, Inc. warrants the FreeWave® ZumLink Z9-PC or Z9-PC-SR001 (Product) that you have
purchased against defects in materials and manufacturing for a period of two years from the date of shipment,
depending on model number. In the event of a Product failure due to materials or workmanship, FreeWave will,
at its discretion, repair or replace the Product. For evaluation of Warranty coverage, return the Product to
FreeWave upon receiving a Return Material Authorization (RMA). The replacement product will remain under
warranty for 90 days or the remainder of the original product warranty period, whichever is longer.
IN NO EVENT WILL FREEWAVE TECHNOLOGIES, INC., ITS SUPPLIERS, OR ITS LICENSORS BE LIABLE FOR ANY DAMAGES ARISING
FROM THE USE OF OR INABILITY TO USE THIS PRODUCT. THIS INCLUDES BUSINESS INTERRUPTION, LOSS OF BUSINESS
INFORMATION, INABILITY TO ACCESS OR SEND COMMUNICATION OR DATA, PERSONAL INJURY OR DAMAGE, OR OTHER LOSS
WHICH MAY ARISE FROM THE USE OF THIS PRODUCT. THE WARRANTY IS EXCLUSIVE AND ALL OTHER WARRANTIES EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE
ARE EXPRESSLY DISCLAIMED.
FreeWave’s Warranty does not apply in the following circumstances:
1. If Product repair, adjustments, or parts replacements are required due to accident, neglect, or undue
physical, electrical, or electromagnetic stress.
2. If Product is used outside of FreeWave specifications as stated in the Product's data sheet.
3. If Product has been modified, repaired, or altered by Customer unless FreeWave specifically authorized
such alterations in each instance in writing. Where applicable, this includes the addition of conformal
coating.
Warning! The Z9-PC / Z9-PC-SR001 are sold as a multi-board solution, assembled at the FreeWave
factory. Any alteration, including the separation of the individual boards, voids the FreeWave
warranty.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 14
Z9-PC / Z9-PC-SR001
User & Reference Manual
1. Overview
Thank you for purchasing the FreeWave Z9-PC / Z9-PC-SR001.
ZumLink is the latest generation of radios offered by FreeWave and consists of enclosed and
board level radios.
l Z9-PC is a board level 900MHz OEM Ethernet radio module.
l Z9-PC-SR001 is a board level 900MHz OEM Ethernet radio module with an RJ-45
Ethernet connector.
The Z9-PC or Z9-PC-SR001 are radio modules ideally suited for OEM applications where it will
be embedded in the OEM product. It is built with the smallest possible footprint and with minimal
industry standard physical connectivity. The intent is for the user to design their own custom
interface to the radio module.
The interface board in the Z9-PC-DEVKIT is not intended to be used in the field. Rather it is a
temporary mechanism to allow a user to evaluate the radio modules without needing to first
design their own interface. If the user desires a ZumLink Ethernet product that has industry
standard connectivity built-in, models Z9-P or Z9-PE should be considered.
The Z9-PC / Z9-PC-SR001 900MHz Series:
l Operates in the unlicensed 900MHz ISM band (902-928 MHz).
l Provides a maximum of 30dBm transmit output power.
l Is FCC compliant as both a Frequency Hopping Spread Spectrum (FHSS) and a Digital
Modulating (DM) radio.
l Provides ZumIQ, a Linux-based application environment for the deployment of applications
at the edge
l Has one Ethernet port, two serial ports, and one micro USB port.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 15
1. Overview
Z9-PC / Z9-PC-SR001
User & Reference Manual
Note: The frequency hopping capability is available at all bandwidths and the single channel (DM)
operation is available for bandwidths of at least 500 kHz.
1.1. Communication Method
ZumLink uses Listen Before Talk (LBT) and Carrier Sense Multiple Access (CSMA) where there
are no assigned slots. The radios transmit when the channel is clear.
l The Gateway broadcasts packets to all Endpoints within range.
l The Endpoints unicast packets back to the Gateway.
l The Gateway acknowledges the Endpoint packets.
FreeWave’s traditional protocol has a Gateway Time Slot and an Endpoint Time Slot within a
frame.
l The Gateway transmits in its slot and listens in the Endpoint slot.
l The Endpoint transmits its slot and listens in the Gateway slot.
1.2. ZumBoost Technology
ZumLink incorporates ZumBoost technology using four performance-enhancing algorithms used
together or independently to improve throughput in the most demanding RF environments:
1.2.1. Adaptive Spectrum Learning
l Learns which RF signals are part of the ZumLink network and which are not, reducing bad
packets and retransmissions.
l Standard on all ZumLink radios, the "Listen Before Talk" algorithm provides spectrum
monitoring, delivering network intelligence and increasing throughputs in noisy
environments.
1.2.2. Forward Error Correction
l The fecRate (on page 204) increases the reliability of the data transferred over the air at the
cost of some transmission throughput.
l Improves sensitivity by 3dB to maximize range and link range in noisy environments.
l Adds redundant information to a data stream to detect packet errors and corrects them to
avoid retransmission of the packet.
1.2.3. Packet Aggregation
l The aggregateEnabled (on page 202) setting increases throughput of small packets by
combining multiple packets into a single packet minimizing the number of packets required
for transmission.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 16
1. Overview
Z9-PC / Z9-PC-SR001
User & Reference Manual
1.2.4. Packet Compression
l When the compressionEnabled (on page 203) setting is enabled, the outgoing packets are
analyzed and, if the data packet can be compressed, sent compressed to transmit fewer
bits over the air.
1.3. ZumIQ Application Environment
ZumLink provides the ZumIQ Application Environment that allows for the development and
deployment of Linux-based applications onto the radio. The application has access to the same
computing resources as the radio but is in a segregated section of the Z9-PC / Z9-PC-SR001.
Note: Any application using a Linux-compatible language can be housed in ZumIQ.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 25
4. Installation
Z9-PC / Z9-PC-SR001
User & Reference Manual
4.1. Power Setup
l The Z9-PC / Z9-PC-SR001 is approved to operate with an input voltage range of +5 to +12
VDC (±10%) that can supply at least 0.8 Amps.
l See the Technical Specifications (on page 412) for additional information.
FREEWAVE Recommends: All input power supply wires should be at least 20AWG wires.
A dedicated and stable power supply line is preferred.
The power supply used MUST provide more current than the amount of current drain listed in the
specifications for the product and voltage. (at least 350 mA at 12V)
Warning! Use electrostatic discharge (ESD) protectors to protect the radio from electric shock
and provide filtered conditioned power with over-voltage protection.
4.2. Installation
1. Install an FCC-approved antenna.
2. Connect the antenna feed line to the ZumLink.
Warning! Only FCC approved antennas may be used. See Approved Antennas (on
page 181).
The antenna must be professionally installed on a fixed, mounted, and permanent
outdoor structure to satisfy RF exposure requirements.
Any antenna placed outdoors must be properly grounded.
Use extreme caution when installing antennas and follow all instructions included with
the antenna.
If installing a directional antenna, preset the antenna’s direction appropriately.
3. Connect the Z9-PC / Z9-PC-SR001 to a power supply.
Note: Power is shared on the Ethernet / Power 10-pin header.
Note: The Z9-PC / Z9-PC-SR001 is approved to operate with an input voltage range of +5 to
+12 VDC (±10%) that can supply at least 0.8 Amps.
FREEWAVE Recommends: All input power supply wires should be at least 20AWG wires.
A dedicated and stable power supply line is preferred.
The power supply used MUST provide more current than the amount of current drain listed in
the specifications for the product and voltage.
The LED lights blink to show startup.
Note: See LEDs (on page 416) for more information.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 34
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
5.3. Firmware Upgrade - Drag and Drop
This is the drag-and-drop procedure to upgrade the Z9-PC / Z9-PC-SR001 firmware.
Warning! The upgrade file names are numbered 1_, 2_, and 3_ and MUST BE INSTALLED
IN A SPECIFIC NUMERIC ORDER for a successful upgrade.
l Alternatively, use the Firmware Upgrade - Web Interface (on page 40) to upgrade the Z9-
PC / Z9-PC-SR001.
l The images in this procedure are for Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
FREEWAVE Recommends: Upgrade to v1.1.0.1 to use the enhanced features and updated
security of the Z9-PC / Z9-PC-SR001.
Prior to an upgrade or downgrade procedure, save and backup all applications.
Caution: This procedure requires the Windows® Explorer file extension to be visible.
See the Microsoft® topic Show or Hide File Name Extensions to view the extensions.
1. Verify the Download the Upgrade File (on page 28) procedure is complete.
2. Connect the USB cable to the computer and the Micro USB end to the Z9-PC Micro-USB
connection.
The FreeWave Drivers and ZumLink windows open.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 35
5. Firmware Upgrade
User & Reference Manual
Figure 14: ZumLink window
3. In the ZumLink window, double-click the connected Z9-PC / Z9-PC-SR001.
The files of the Z9-PC / Z9-PC-SR001 appear in the window. (Figure 15)
Z9-PC / Z9-PC-SR001
Figure 15: Opened ZumLink window showing the Default Files
4. Optional: Select, copy, and paste the config.txt file to a secure location.
Note: This is to backup the current config.txt before the upgrade process in case the old
config.txt file needs to be restored.
5. Locate and select the downloaded 1_Device_Firmware_v1_1_0_1.pkg upgrade file.
(Figure 16)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
6. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .pkg file to .pkg.txt and select that file.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 37
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
The ZumLink window is similar to Figure 18:
Figure 18: 1_Device_Firmware_v1_1_0_1.pkg.txt File Dropped in the
ZumLink window
The .pkg or .pkg.txt file will disappear after approximately 6-10 minutes.
8. WAIT a few minutes for the FreeWave Drivers and ZumLink windows to close.
The Z9-PC / Z9-PC-SR001 automatically reboots.
Warning! DO NOT remove power from the Z9-PC / Z9-PC-SR001 during the firmware
upgrade process!
If power is removed prematurely during the upgrade process, the Web Interface pages
may not be accessible.
Reinstall the .pkg file and WAIT for the file upgrade process to complete.
The LEDs (on page 416) indicated the upgrade process.
The FreeWave Drivers and ZumLink windows re-open when the .pkg or .pkg.txt
upgrade file is applied.
9. In the ZumLink window, double-click the connected Z9-PC / Z9-PC-SR001.
The files of the Z9-PC / Z9-PC-SR001 appear in the window.
10. Locate and select the downloaded 2_Radio_Firmware_v1_0_7_1.fcf upgrade file.
(Figure 19)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
11. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .fcf file to .fcf.txt and select that file.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 39
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
Important!: For the v1.1.0.1 upgrade, these parameters should have this information:
systemInfo.radioFirmwareVersion=FWT1071TR.35.
Web Interface - Radio Firmware Version is FWT1071TR.35.
systemInfo.deviceFirmwareVersion=FWT1101TB.17
Web Interface - Device Firmware Version is FWT1101TB.17
If these versions are NOT listed in their respective parameters, repeat the upgrade procedure.
15. Continue with:
l Optional: Drag and Drop - Installation of ZumIQ Application Environment (on page 89)
l Drag and Drop Configuration - ZumLink (on page 52)
l CLI Configuration (on page 64)
Figure 21: sys.info.txt file with Updated Firmware
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 40
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
5.4. Firmware Upgrade - Web Interface
This procedure uses a web browser window to upgrade the Z9-PC / Z9-PC-SR001 firmware.
Warning! The upgrade file names are numbered 1_, 2_, and 3_ and MUST BE INSTALLED
IN A SPECIFIC NUMERIC ORDER for a successful upgrade.
l Alternatively, use the Firmware Upgrade - Drag and Drop (on page 34) to upgrade the Z9-
PC / Z9-PC-SR001.
l The images in this procedure are for Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
FREEWAVE Recommends: Upgrade to v1.1.0.1 to use the enhanced features and updated
security of the Z9-PC / Z9-PC-SR001.
Prior to an upgrade or downgrade procedure, save and backup all applications.
Caution: This procedure requires the Windows® Explorer file extension to be visible.
See the Microsoft® topic Show or Hide File Name Extensions to view the extensions.
The Z9-PC / Z9-PC-SR001 upgrade process requires these basic steps:
A. Download the Upgrade File (on page 28)
B. Setup the Computer IP Address Configuration (on page 41)
C. Install the Upgrade File using the Web Interface (on page 45)
Note: This method is used for computers running Windows® 7 and later.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 44
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
10. In the IP Address text box, enter an IP Address that is in the same subnet range but aDIFFERENT IP Address than the Z9-PC / Z9-PC-SR001 or all other units in the network.
(Figure 28)
Example: Enter an IP Address from 192.168.111.1 to 192.168.111.254 (but NOT
192.168.111.100) and the Subnet Mask to 255.255.255.0.
Note: The default Z9-PC / Z9-PC-SR001 IP Address is 192.168.111.100.
The default subnet mask is 255.255.255.0.
Figure 28: Changed Internet Protocol Version 4 (TCP/IPv4) Properties
dialog box
Note: An IP Address is NOT required in the Default Gateway text box.
11. Click OK to save the changes and close the dialog box.
12. Click Close twice to close the Local Area Connection Properties and Local AreaConnection Status dialog boxes.
13. Continue with Install the Upgrade File using the Web Interface (on page 45).
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 45
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
5.4.2. Install the Upgrade File using the Web Interface
Note: The images in this procedure are for Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
1. Verify the Download the Upgrade File (on page 28) procedure is complete.
2. Using a CAT5e / CAT6 Ethernet cable, connect the Z9-PC / Z9-PC-SR001 Ethernet port
to the computer's Ethernet port.
3. Open a web browser.
4. In the URL address bar, enter the IP address of the attached Z9-PC / Z9-PC-SR001.
Note: If this is the first time the Z9-PC / Z9-PC-SR001 is accessed, enter its default IP
address of 192.168.111.100.
If the IP address was changed, enter that IP Address.
5. Refresh the browser window (press <Enter> or <F5>).
The Home window (on page 343) opens.
6. On the Menu bar, click the File Upload link. (Figure 29)
Figure 29: File Upload link
The Authentication Required (Login) dialog box opens.
7. Enter admin in both the User Name and Password text boxes and click OK.
The Login dialog box closes and the File Upload window opens.
Note: If the User Name or Password were changed, enter the applicable information.
Figure 30: File Upload window
8. Click the Browse button.
The File Upload dialog box opens.
9. Locate and select the downloaded 1_Device_Firmware_v1_1_0_1.pkg upgrade file.
(Figure 31)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 46
5. Firmware Upgrade
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
Z9-PC / Z9-PC-SR001
User & Reference Manual
10. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .pkg file to .pkg.txt and select that file.
Figure 31: File Upload dialog box with Selected
1_Device_Firmware_v1_1_0_1.pkg.txt File
11. Click Open.
The dialog box closes and the File Upload window returns showing the selected file.
(Figure 32)
13. Wait for the .pkg or .pkg.txt file to be applied (≈ 6-10 minutes).
Z9-PC / Z9-PC-SR001
User & Reference Manual
Warning! DO NOT remove power from the Z9-PC / Z9-PC-SR001 during the firmware
upgrade process!
If power is removed prematurely during the upgrade process, the Web Interface pages
may not be accessible.
Reinstall the .pkg file and WAIT for the file upgrade process to complete.
The File Upload window refreshes and shows the completed and uploaded file applied to
the Z9-PC / Z9-PC-SR001. (Figure 34)
The LEDs (on page 416) indicated the upgrade process.
Figure 34: File Upload window Showing Completed Upload of the Selected
File
14. Click the Browse button.
The File Upload dialog box opens.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 48
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
15. Locate and select the downloaded 2_Radio_Firmware_v1_0_7_1.fcf upgrade file.
(Figure 35)
16. Optional: If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change
the extension of the .fcf file to .fcf.txt and select that file.
Figure 35: File Upload dialog box with Selected .fcf File
17. Click Open.
The dialog box closes and the File Upload window returns showing the selected file.
(Figure 36)
Figure 36: File Upload window with Selected .fcf File
18. Click Send.
The File Upload window changes to show the completed upload percentage to the Z9-PC
/ Z9-PC-SR001. (Figure 37)
Note: The .fcf file uploads very quickly (≈ 1-2 minutes).
The LEDs (on page 416) indicated the upgrade process.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 50
5. Firmware Upgrade
Z9-PC / Z9-PC-SR001
User & Reference Manual
Important!: For the v1.1.0.1 upgrade, these parameters should have this information:
systemInfo.radioFirmwareVersion=FWT1071TR.35.
Web Interface - Radio Firmware Version is FWT1071TR.35.
systemInfo.deviceFirmwareVersion=FWT1101TB.17
Web Interface - Device Firmware Version is FWT1101TB.17
If these versions are NOT listed in their respective parameters, repeat the upgrade procedure.
20. Continue with:
l Optional: Web Interface - Installation of ZumIQ Application Environment (on page 92)
l Web Interface Configuration - Z9-PC / Z9-PC-SR001 (on page 80)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 54
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 45: Notepad® window - File > Save As menu.
The Save As dialog box opens.
11. In the File Name text box, enter a file name with either the .cfg or .cfg.txt extension.
Note: The file name used in this example is for illustration purposes only.
Any name can be used. NO SPACES are allowed in the file name.
Caution: A .cfg file extension is required for Windows® 7.
A .cfg.txt file extension may be required for some versions of Windows® 8 and
Windows® 10.
Failure to save the file with the correct extension type results in the file NOT being able
to integrate with the ZumLink config.txt file when copied to the ZumLink window.
12. Click the Save as type list box arrow and select All Files.
Figure 46: Save As dialog box with All Files (*.*) selected.
13.
Click.
The dialog box closes and the text editor returns with the new .cfg or .cfg.txt file open.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 55
6. Configuration
Note: See the systemInfo Parameters (on page 304) for detailed information about the
parameters.
l [Page=radioSettings]
l radioSettings.txPower
l radioSettings.rfDataRate***
l radioSettings.radioMode
l radioSettings.networkId***
l radioSettings.nodeId**
l radioSettings.radioFrequency***
l radioSettings.radioHoppingMode***
l radioSettings.beaconInterval
Note: See radioSettings Parameters (on page 254) for detailed information about these
settings.
**Each radio with the same networkId must have a UNIQUE nodeId.
A unique nodeId is required so that only one node will unicast an acknowledgment.
Otherwise, two or more nodes will unicast an acknowledgment that may collide.
***These are the Golden Settings and they MUST match between all radios with the same
networkId.
Z9-PC / Z9-PC-SR001
User & Reference Manual
Important!: With radioHoppingMode enabled, only one radio can be designated as a
Gateway or Gateway-Repeater. All other radios MUST be designated as Endpoints or
Endpoint-Repeaters. For detailed information, see the radioSettings Parameters (on page
254).
Example: For illustration, the radioSettings.radioMode was changed from Endpoint to
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 60
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 56: Notepad® window - File > Save As menu.
The Save As dialog box opens.
11. In the File Name text box, enter a file name with either the .cfg or .cfg.txt extension.
Note: The file name used in this example is for illustration purposes only.
Any name can be used. NO SPACES are allowed in the file name.
Caution: A .cfg file extension is required for Windows® 7.
A .cfg.txt file extension may be required for some versions of Windows® 8 and
Windows® 10.
Failure to save the file with the correct extension type results in the file NOT being able
to integrate with the ZumLink config.txt file when copied to the ZumLink window.
12. Click the Save as type list box arrow and select All Files.
Figure 57: Save As dialog box with All Files (*.*) selected.
13.
Click.
The dialog box closes and the text editor returns with the new .cfg or .cfg.txt file open.
14. As applicable, change these Network settings to meet the network architecture:
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 64
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
6.3. CLI Configuration
This procedure provides a Tera Term terminal connection to the Z9-PC / Z9-PC-SR001 CLI.
Other terminal emulators (e.g., HyperTerminal, PuTTY) may be used.
The basic steps are:
A. Connect the Z9-PC / Z9-PC-SR001 to the Computer (on page 64)
B. Tera Term Activation and ZumLink Setup (on page 65)
Note: The images in this procedure are for Windows® 7 or Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
6.3.1. Connect the Z9-PC / Z9-PC-SR001 to the Computer
Note: This procedure is for a Z9-PC OEM module interfaced to a computer.
If interfaced to a device other than a computer, some of these procedure steps may not be used.
1. Connect the USB cable to the computer and the Micro USB end to the Z9-PC / Z9-PCSR001.
The FreeWave Drivers and ZumLink windows may open.
Figure 62: FreeWave Drivers window
Figure 63: ZumLink window
2. Continue withTera Term Activation and ZumLink Setup (on page 65).
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 65
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
6.3.2. Tera Term Activation and ZumLink Setup
Note: This procedure is for a Z9-PC OEM module interfaced to a computer.
If interfaced to a device other than a computer, some of these procedure steps may not be used.
Note: This procedure provides a Tera Term terminal connection to the Z9-PC / Z9-PC-SR001 CLI.
Other terminal emulators (e.g., HyperTerminal, PuTTY) may be used.
The images in this procedure are for Windows® 7 or Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
1. On the computer connected to the Z9-PC / Z9-PC-SR001 device, open a terminal program
(e.g., Tera Term http://ttssh2.osdn.jp/).
2. In Tera Term, click the File menu and select New Connection.
Figure 64: File menu > New Connection
The Tera Term New Connection dialog box opens.
3. Click the Port list box arrow and select the COM port the Z9-PC / Z9-PC-SR001 is
connected to.
Figure 65: Select the ZumLink COM port
Important!: The Port assignment varies from computer to computer.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 66
6. Configuration
4. Click OK to save the changes and close the dialog box.
The Tera Term window shows the connected COM port and Baud rate in the title bar of the
window.
5. In the Tera Term window, click the Setup menu and select Serial Port.
Figure 66: Serial menu > Setup Port
The Tera Term: Serial Port Setup dialog box opens.
Note: The image shows the default Z9-PC / Z9-PC-SR001 settings.
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 67: Tera Term: Serial Port Setup dialog box with Default Settings
6. Important: Verify, and change if required, the Tera Term serial port settings (except the
Port setting) of the connected Z9-PC / Z9-PC-SR001 so the settings are the same as the
defaults shown in Figure 67.
7. Verify the COM port settings are:
Baud Rate / Baudrate: 115200
Data / Databits: 8 bit
Parity: none
Stop / Stopbits: 1 bit
8. Click OK to save the changes and close the dialog box.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 68
6. Configuration
13. At the > prompt, type network and press <Enter>.
The Z9-PC / Z9-PC-SR001 network settings appear.
Figure 70: network Page window
Note: Steps 14 to 17 make the IP Address and nodeId unique to each Z9-PC / Z9-PC-SR001.
Other values may be defined as long as they are unique to each Z9-PC / Z9-PC-SR001.
Z9-PC / Z9-PC-SR001
User & Reference Manual
14. At the > prompt, type ip_address=nnn.nnn.nnn.nnn and press <Enter>.
Note: Where nnn.nnn.nnn.nnn is the IP address assigned by the IT department for the
Z9-PC / Z9-PC-SR001 network.
Note:
15. Optional: Change the gateway (on page 238) and the netmask (on page 241) addresses, if
required, to meet the Z9-PC / Z9-PC-SR001 network architecture.
16. At the > prompt, type radiosettings and press <Enter>.
The Z9-PC / Z9-PC-SR001 radioSettings appear.
Important!: Figure 71 shows ALL available settings for the page.
Only radioSettings that apply to the current radioMode, rfDataRate, and
radioHoppingMode, and are visible in the CLI and the Web Interface and can be changed.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 70
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
6.3.3. Tera Term Activation and ZumIQ Setup
Note: This procedure provides a Tera Term terminal connection to the Z9-PC / Z9-PC-SR001 CLI.
Other terminal emulators (e.g., HyperTerminal, PuTTY) may be used.
The images in this procedure are for Windows® 7 or Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
1. On the computer connected to the Z9-PC / Z9-PC-SR001 device, open a terminal program
(e.g., Tera Term http://ttssh2.osdn.jp/).
2. In Tera Term, click the File menu and select New Connection.
Figure 72: File menu > New Connection
The Tera Term New Connection dialog box opens.
3. Click the Port list box arrow and select the COM port the Z9-PC / Z9-PC-SR001 is
connected to.
Figure 73: Select the ZumLink COM port
Important!: The Port assignment varies from computer to computer.
4. Click OK to save the changes and close the dialog box.
The Tera Term window shows the connected COM port and Baud rate in the title bar of the
window.
5. In the Tera Term window, click the Setup menu and select Serial Port.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 71
6. Configuration
The Tera Term: Serial Port Setup dialog box opens.
Note: The image shows the default Z9-PC / Z9-PC-SR001 settings.
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 74: Serial menu > Setup Port
Figure 75: Tera Term: Serial Port Setup dialog box with Default Settings
6. Important: Verify, and change if required, the Tera Term serial port settings (except the
Port setting) of the connected Z9-PC / Z9-PC-SR001 so the settings are the same as the
defaults shown in Figure 75.
7. Verify the COM port settings are:
Baud Rate / Baudrate: 115200
Data / Databits: 8 bit
Parity: none
Stop / Stopbits: 1 bit
8. Click OK to save the changes and close the dialog box.
9. In the Tera Term window, press <Enter>.
The Z9-PC / Z9-PC-SR001 CLI Login returns.
10. Enter admin for the Username and press <Enter>.
11. Enter admin for the Password and press <Enter>.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 73
6. Configuration
Note: Where nnn.nnn.nnn.nnn is the IP address assigned by the IT department for the
Z9-PC / Z9-PC-SR001 network.
Z9-PC / Z9-PC-SR001
User & Reference Manual
14. Optional: Change the gateway (on page 238) and the netmask (on page 241) addresses, if
required, to meet the Z9-PC / Z9-PC-SR001 network architecture.
15. At the > prompt, type save and press <Enter>.
Warning! At this point, the connection to the Z9-PC / Z9-PC-SR001 is disabled.
16. Re-connect to the Z9-PC / Z9-PC-SR001 using the new IP Address entered in Step 13.
17. Continue with ZumIQ Application Environment (on page 86).
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 75
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
6.4.1. Connect the Z9-PC / Z9-PC-SR001 to the Computer
Note: The images in this procedure are for Windows® 7 or Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
Note: This procedure is for a Z9-PC OEM module interfaced to a computer.
If interfaced to a device other than a computer, some of these procedure steps may not be used.
1. Connect the USB cable to the computer and the Micro USB end to the Z9-PC / Z9-PCSR001.
The FreeWave Drivers and ZumLink windows may open.
Note: One of the Network Connections icons may change to show the connected Z9-PC /
Z9-PC-SR001.
2. Verify the ZumLink drivers are installed.
See Install the Driver.
Figure 78: FreeWave Drivers window
Figure 79: ZumLink window
3. Continue with Setup the Computer IP Address Configuration (on page 76).
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 79
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
10. In the IP Address text box, enter an IP Address that is in the same subnet range but aDIFFERENT IP Address than the Z9-PC / Z9-PC-SR001 or all other units in the network.
(Figure 86)
Example: Enter an IP Address from 192.168.111.1 to 192.168.111.254 (but NOT
192.168.111.100) and the Subnet Mask to 255.255.255.0.
Note: The default Z9-PC / Z9-PC-SR001 IP Address is 192.168.111.100.
The default subnet mask is 255.255.255.0.
Figure 86: Changed Internet Protocol Version 4 (TCP/IPv4) Properties
dialog box
Note: An IP Address is NOT required in the Default Gateway text box.
11. Click OK to save the changes and close the dialog box.
12. Click Close twice to close the Local Area Connection Properties and Local AreaConnection Status dialog boxes.
13. Continue with Web Interface Configuration - Z9-PC / Z9-PC-SR001 (on page 80).
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 80
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
6.4.3. Web Interface Configuration - Z9-PC / Z9-PC-SR001
1. Open a web browser.
2. In the URL address bar, enter the IP address of the attached Z9-PC / Z9-PC-SR001.
Note: If this is the first time the Z9-PC / Z9-PC-SR001 is accessed, enter its default IP
address of 192.168.111.100.
If the IP address was changed, enter that IP Address.
3. Refresh the browser window (press <Enter> or <F5>).
The Home window (on page 343) opens.
Figure 87: Home window
4. On the Menu bar, click the Configuration link. (Figure 88)
Figure 88: Configuration link
The Authentication Required (Login) dialog box opens. (Figure 89)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 82
6. Configuration
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 91: Network window
Note: Steps 7 to 9 make the IP Address and nodeId unique to each Z9-PC / Z9-PC-SR001.
Other values may be defined as long as they are unique to each Z9-PC / Z9-PC-SR001.
7. In the IP Address text box, enter the new IP Address for the Z9-PC / Z9-PC-SR001.
Note: Where nnn.nnn.nnn.nnn is the IP address assigned by the IT department for the
Z9-PC / Z9-PC-SR001 network.
8. Optional: Change the gateway (on page 238) and the netmask (on page 241) addresses, if
required, to meet the Z9-PC / Z9-PC-SR001 network architecture.
9. Click the Update button to save the changed information.
Warning! At this point, the connection to the Z9-PC / Z9-PC-SR001 is disabled.
10. Re-connect to the Z9-PC / Z9-PC-SR001 using the new IP Address entered in Step 7.
11. In the Configuration window, click the Radio Settings tab.
The Radio Settings parameters are shown in Figure 92:
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 85
7. Creating a Basic ZumLink Gateway and Endpoint Network
Z9-PC / Z9-PC-SR001
User & Reference Manual
Procedure
Note: This example procedure is specific for CLI configuration.
1. Connect and apply power to the ZumLink devices in the network.
2. Optional: Upgrade the devices using the Firmware Upgrade - Drag and Drop procedure.
Caution: Firmware v1.0.7.0 is NOT a required upgrade. ONLY upgrade the Z9-PC /
Z9-PC-SR001 firmware if the user values the new features and fixes within a firmware
version.
3. Complete the procedure.
4. Select one radio and, at the > prompt, type radioSettings.radioMode=Gateway
and press <Enter>.
5. At the > prompt, type a setting between 10 and 30 for the radioSettings.txPower and
press <Enter>.
Example: txPower=30 or radioSettings.txPower=30.
Entering txpower=0 or radiosettings.txpower=0 changes the output power to the
minimum or 10 dB.
Note: See radioSettings Parameters (on page 254) for detailed information.
6. For the other radio in the network, at the > prompt, type
radioSettings.radioMode=Endpoint and press <Enter>.
7. Verify the radioSettings.networkId= setting is the same on ALL radios in the
network.
Note: For Endpoints, the radioSettings.nodeID is set automatically.
Important!: The Gateway radioSettings.nodeId defaults to 1 and CANNOT be changed.
8. At the > prompt, type save and press <Enter>.
A solid green CD LED indicates that the radios are linked.
Note: See LEDs (on page 416) for additional information.
9. Type exit and press <Enter> to exit the FreeWave Shell.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 86
Z9-PC / Z9-PC-SR001
User & Reference Manual
8. ZumIQ Application Environment
The Z9-PC / Z9-PC-SR001 employs the ZumIQ Application Environment to provide application
development and deployment for intelligent monitoring and control of remote sensors and
devices.
Download and Install
l Optional: Download the ZumIQ Application Environment (on page 87)
l Optional: Drag and Drop - Installation of ZumIQ Application Environment (on page 89)
l Optional: Web Interface - Installation of ZumIQ Application Environment (on page 92)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 89
8. ZumIQ Application Environment
Z9-PC / Z9-PC-SR001
User & Reference Manual
8.2. Optional: Drag and Drop - Installation of ZumIQ
Application Environment
FREEWAVE Recommends: If currently using the v1.0.6.0 developer environment, an upgrade to
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg is NOT required.
1. IMPORTANT: Install the 1_Device_Firmware_v1_1_0_1.pkg or 1_Device_Firmware_
v1_1_0_1.pkg.txt file first.
See Firmware Upgrade - Drag and Drop (on page 34).
Warning! The Z9-PC / Z9-PC-SR001 MUST BE upgraded to the Firmware v1_1_0_1
release or the ZumIQ Application Environment will NOT function.
2. Verify the Download the Upgrade File (on page 28) procedure is completed.
3. Locate and select the downloaded 3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
upgrade file. (Figure 98)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
4. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .pkg file to .pkg.txt and select that file.
Figure 98: File Upload dialog box with Selected 3_Optional_ZumIQ_
Environment_v1_1_0_0.pkg.txt File
5. Drag and drop the .pkg or .pkg.txt file on to the ZumLink window. (Figure 99)
The .pkg or .pkg.txt file will disappear after approximately 6-10 minutes.
Note: Refresh the ZumLink window If, after 10-15 minutes, the .pkg.txt file has NOT
disappeared.
Warning! DO NOT remove power from the Z9-PC / Z9-PC-SR001 during the firmware
upgrade process!
If power is removed prematurely during the upgrade process, the Web Interface pages
may not be accessible.
Reinstall the .pkg file and WAIT for the file upgrade process to complete.
6. Optional: Open the sys.info.txt file to verify the upgrade information. (Figure 101)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 91
8. ZumIQ Application Environment
Important!: The image provides example information only.
Each Z9-PC / Z9-PC-SR001 provides its own unique information.
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 101: sys.info.txt file with Updated Firmware
Important!: For the v1.1.0.1 upgrade, these settings should have this information:
systemInfo.deviceFirmwareVersion=FWT1101TB.17
Web Interface - Device Firmware Version is FWT1101TB.17
systemInfo.rteTemplateVersion=FWT1100TP.2
Web Interface - Rte Template Version is FWT1100TP.2
If neither of these are listed in their respective settings, repeat the upgrade procedure.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 92
8. ZumIQ Application Environment
Z9-PC / Z9-PC-SR001
User & Reference Manual
8.3. Optional: Web Interface - Installation of ZumIQ
Application Environment
FREEWAVE Recommends: If currently using the v1.0.6.0 developer environment, an upgrade to
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg is NOT required.
1. IMPORTANT: Install the 1_Device_Firmware_v1_1_0_1.pkg or 1_Device_Firmware_
v1_1_0_1.pkg.txt file first.
See Firmware Upgrade - Web Interface (on page 40).
Warning! The Z9-PC / Z9-PC-SR001 MUST BE upgraded to the Firmware v1_1_0_1
release or the ZumIQ Application Environment will NOT function.
Important!: If continuing from the Firmware Upgrade - Web Interface (on page 40) procedure
for the Firmware v1_1_0_1.zip file, go to Step 7.
2. Verify the Download the Upgrade File (on page 28) procedure is completed.
3. Using a CAT5e / CAT6 Ethernet cable, connect the Z9-PC / Z9-PC-SR001 Ethernet port
to the computer's Ethernet port.
4. Open a web browser.
5. In the URL address bar, enter the IP address of the attached Z9-PC / Z9-PC-SR001.
Note: If this is the first time the Z9-PC / Z9-PC-SR001 is accessed, enter its default IP
address of 192.168.111.100.
If the IP address was changed, enter that IP Address.
6. Refresh the browser window (press <Enter> or <F5>).
The Home window (on page 343) opens.
7. On the Menu bar, click the File Upload link. (Figure 102)
Figure 102: File Upload link
The Authentication Required (Login) dialog box opens.
8. Enter admin in both the User Name and Password text boxes and click OK.
The Login dialog box closes and theFile Upload window opens. (Figure 103)
Note: If the User Name or Password were changed, enter the applicable information.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 93
8. ZumIQ Application Environment
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 103: File Upload window
9. Click the Browse button.
The File Upload dialog box opens.
10. Locate and select the downloaded 3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
upgrade file. (Figure 104)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
11. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .pkg file to .pkg.txt and select that file.
14. Wait for the .pkg or .pkg.txt file to be applied (≈ 6-10 minutes).
Warning! DO NOT remove power from the Z9-PC / Z9-PC-SR001 during the firmware
upgrade process!
If power is removed prematurely during the upgrade process, the Web Interface pages
may not be accessible.
Reinstall the .pkg file and WAIT for the file upgrade process to complete.
The File Upload window refreshes and shows the completed and uploaded file applied to
the Z9-PC / Z9-PC-SR001. (Figure 107)
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 96
8. ZumIQ Application Environment
Z9-PC / Z9-PC-SR001
User & Reference Manual
Figure 109: System Info window
Important!: For the v1.1.0.1 upgrade, these settings should have this information:
systemInfo.deviceFirmwareVersion=FWT1101TB.17
Web Interface - Device Firmware Version is FWT1101TB.17
systemInfo.rteTemplateVersion=FWT1100TP.2
Web Interface - Rte Template Version is FWT1100TP.2
If neither of these are listed in their respective settings, repeat the upgrade procedure.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 97
8. ZumIQ Application Environment
Z9-PC / Z9-PC-SR001
User & Reference Manual
8.4. Activating ZumIQ
Warning! The process of activating ZumIQ will install a fresh copy of the Linux development
environment that supports ZumIQ.
If ZumIQ has already been activated, this procedure will erase any user-generated content and
settings in the existing Linux development environment.
Note: The images in this procedure are for Windows® 7 or Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
Procedure
1. Complete the Tera Term Activation and ZumIQ Setup (on page 70).
2. Log in to the Z9-PC / Z9-PC-SR001 CLI as admin.
3. At the > prompt, type systemInfo and press <Enter>.
The systemInfo parameters appear. (Figure 110)
Note: See the systemInfo Parameters (on page 304) for detailed information about the
parameters.
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Page 98
8. ZumIQ Application Environment
Verification Settings
ParameterValue
radioFirmwareVersion (on page 310)FWT1040TA.11
deviceFirmwareVersion (on page 305)FWT1060TB.68
rteVersion (on page 312)(blank)
rteTemplateVersion (on page 312)FWT1060TB.68
licenses (on page 308)Custom Apps
Z9-PC / Z9-PC-SR001
User & Reference Manual
5. At the > prompt, type rteReset=Hard and press <Enter>.
This will stage the development runtimeEnvironment to be applied on the next reboot.
6. At the > prompt, type the exact command of reset=now and press <Enter>.
This reboots the Z9-PC / Z9-PC-SR001 and copies the Linux application environment into
the runtime location.
This will take ~3-4 minutes to complete.
Warning! At this point, the connection to the Z9-PC / Z9-PC-SR001 is disabled.
7. Close the Tera Term window.
8. Disconnect and reconnect the USB cable from the computer.
The AutoPlay ZumLink and ZumLink windows open again.
9. Continue with Verify ZumIQ Activation (on page 99).