Freenotes Harmony Park FEEH1022 Installation & Assembly

PEGASUS
3
47
"
4
INSTALLATION GUIDE
7
18
"
8
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F DURANGO CO 81303 TEL: (970) 375-7825 FAX: (970) 247-0856 WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FREENOTES HARMONY PARK. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FREENOTES HARMONY PARK IS PROHIBITED.
43" Adult
39" Ages 7-11
34" Ages 5-7 29" Ages 3-5
Main Features:
(LH) A Minor / (RH) C Major Pentatonic
Contents:
SHEET 2 - Parts List and Instrument to Post Installation
Weights:
Instrument Weight, 49lbs.
Pegasus - Installation Guide
TITLE:
REVISION: B
SCALE: 1:16
DATE: 2/9/2018
SHEET 1 OF 4
PEG-INSTALL
DWG. NO.
Parts List:
ITEM NO.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
Step 1:
predrilled. Screw heads should be flush with the Holster surface when properly installed. Holster should also be flush along the back. Drive Screws slowly to prevent stripping.
PART DESCRIPTION
Pegasus Instrument Assembly
Small SS Holster
In Ground Recycled Post, 72"lg.
In Ground Steel Post, 72"lg.
Surface Mount Recycled Post, 36"lg.
Surface Mount Steel Post, 36"lg.
Surface Mount Base, For Recycled Post
#8 Flat Head Screw, .5"lg. SS, T15 tamp
#8 Button Head Screw, 1.25"lg. SS, T15 tamp
#10-24 Button Head Machine Screw, 1"lg. SS, T25 tamp
5/16" Hex Head Lag Bolt, 5"lg. SS
3/8"-16 Wedge Expansion Anchor, SS
35/64" Hex Nut Cap
Security Driver
In Ground -
Recycled Post/QTY.
1 1 1 1 2 2 2 2
2
-
- -
- - -
- -
8 8 8 8
10
-
- -
- -
- -
1 1 1 1
In Ground -
Steel Post/QTY.
- - -
2
-
10
Surface Mount
Recycled Post/QTY.
- -
2
2
10
­4 8 8 8 8
Surface Mount
Steel Post/QTY.
-
2
-
-
10
-
Start by mounting the Holsters to the Instrument Back with the provided #8 Flat Head Screws and Driver. The Back comes
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F DURANGO CO 81303 TEL: (970) 375-7825 FAX: (970) 247-0856 WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FREENOTES HARMONY PARK. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FREENOTES HARMONY PARK IS PROHIBITED.
Step 2:
With two people, situate the Instrument with Holsters installed onto the Posts. Posts come predrilled and/or tapped. Fasten the Instrument to the Posts with the provided #8 Button Head Screw for Recycled Posts or #10-24 Button Head Machine Screw for Steel Posts. Drivers are provided.
1
9/10
8
DETAIL B
SCALE 1 : 4
DETAIL A
SCALE 1 : 4
2
PEG-INSTALL
Parts List and Instrument to Post Installation
TITLE:
REVISION: B
SCALE: 1:16
DATE: 2/9/2018
DWG. NO.
SHEET 2 OF 4
Step 1:
Excavate two 10" diameter holes, 36" deep, and 32" on center at the installation location. Contractor can modify Post to
desired height.
Post Length = Frost Depth
(36" Recommended)
+ Finished Post Height
Finished Post Height Guideline: (
Step 2:
Step 3:
With two people, lower the Posts with the Instrument attached into the excavated holes.
Verify the correct placement, levelness, and finished height of the Instrument. Check for sufficient clearance around the
Ages 3-5, 22"
) (
Ages 5-7, 27"
) (
Ages 7-11, 32"
) (
Adult, 36"
)
Instrument, a 36" perimeter around the Instrument is recommended for wheelchair accessibility.
Step 4:
Last pour concrete around the posts. It is recommended to brace the Instrument to hold it rigid while the concrete cures.
Leave to set according to the concrete manufacturers guidelines. Approximately (6) 80lb. bags will be needed.
1
3/4
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F DURANGO CO 81303 TEL: (970) 375-7825 FAX: (970) 247-0856 WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FREENOTES HARMONY PARK. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FREENOTES HARMONY PARK IS PROHIBITED.
Ground Level
32" On
Center
Finished Post Height
Post Length
Frost Depth
In Ground Installation
TITLE:
REVISION: B
SCALE: 1:16
DATE: 2/9/2018
SHEET 3 OF 4
PEG-INSTALL
DWG. NO.
Step 1:
Standard height for Surface Mount Posts are 36". The Recycled Posts may be modified in the field to the following heights:
(
Ages 3-5, 22"
) (
Ages 5-7, 27"
) (
Ages 7-11, 32"
) (
Adult, 36"
The height of Surface Mount Steel Posts can not be adjusted.
)
Step 2:
Determine installation location. Verify concrete footing is a minimum of 48" long x 24" wide x 6" thick. If the concrete pad is at an angle, steel washers are required to act as shims (Shims not provided). If there is not already an existing pad, approximately (7) 80lb. bags will be needed. Allow concrete to cure per concrete manufacturers guidelines.
Step 3 (Recycled Post Only):
the Posts. The Bases should fit snuggly around the Posts. Fasten them together with the provided
Step 4:
With two people place the Instrument Assembly with Posts attached onto the concrete pad and mark the center of the holes
Install the Surface Mount Bases to the bottom of the Posts. Align the holes on the Bases with the holes on
5/16" Hex Head Lag Bolt
on the surface mount bases. After you have made your marks, set aside the Instrument in order to drill for anchor holes. With a hammer or rotary drill, drill through concrete at marked locations. Drill to a minimum depth of 4". A 3/8" masonry drill bit will be needed.
Step 5:
Place the Instrument back over the drilled out holes. Insert provided anchor bolts into aligned holes. Position anchor nut so that it is flush with the top of the bolt. Pound anchor bolts into the hole until the anchor washer is flush with the surface mount bases. Tighten anchor bolts until they are snug. Cover remaining bolt sections with provided nut caps.
Step 6:
Verify the correct placement, levelness, and finished height of the Instrument. Check for sufficient clearance around the Instrument, a 36" perimeter around the Instrument is recommended for wheelchair accessibility.
Step 7:
If installing onto wet concrete, us the wet set anchor manufacturers guidelines for installation procedures.
s.
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F DURANGO CO 81303 TEL: (970) 375-7825 FAX: (970) 247-0856 WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FREENOTES HARMONY PARK. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FREENOTES HARMONY PARK IS PROHIBITED.
1
13
12
DETAIL C
SCALE 1 : 6
3/8" Drill Diameter
to a Depth of 4"
Concrete Pad
48"
5/6
24"
6"
Surface Mount Installation
TITLE:
REVISION: B
SCALE: 1:16
DATE: 2/9/2018
SHEET 4 OF 4
PEG-INSTALL
DWG. NO.
Loading...