CONTRABASS CHIMES
4" Typ.
INSTALLATION GUIDE
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F
DURANGO CO 81303
TEL: (970) 375-7825
FAX: (970) 247-0856
WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
FREENOTES HARMONY PARK. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF FREENOTES HARMONY
PARK IS PROHIBITED.
91
95
1
0"
3
100
1
2
"
4
"
4
"
104
1
"
2
98
3
"
4
93
1
"
4
88"
Main Features:
C Major Pentatonic
•
Steel Powder Coated Support Poles
•
Anodized Aluminum Chimes
•
Stainless Steel Hardware
•
CCH-INSTALL
Contents:
SHEET 2 - In Ground Installation w/ Parts List
•
SHEET 3 - Surface Mount Installation w/ Parts List
•
Weights:
Instrument Weight, 30-35lbs per chime
•
Boxed Instrument Weight, 35-40lbs. per chime
•
Mallet Pole Weight, 37lbs.
•
Boxed Mallet Pole Weight, 40lbs.
•
Contrabass Chimes - Installation Guide
TITLE:
REVISION: A
SCALE: 1:32
DATE: 2/7/2018
DWG. NO.
SHEET 1 OF 3

Parts List:
ITEM NO.
1
2
3
4
5
6
7
8
Step 1:
Contrabass Chimes - In Ground Chime Assembly 1
Contrabass Chimes - In Ground Chime Assembly 2
Contrabass Chimes - In Ground Chime Assembly 3
Contrabass Chimes - In Ground Chime Assembly 4
Contrabass Chimes - In Ground Chime Assembly 5
Contrabass Chimes - In Ground Chime Assembly 6
Contrabass Chimes - In Ground Chime Assembly 7
Contrabass Chimes - In Ground Mallet Pole Assembly
Determine your layout. Spacing between Chimes
DESCRIPTION
and Mallet Poles must be maintained per the
diagram shown to allow the Mallets to reach each
Chime. Although the Chimes can be laid out in a
variety of styles such as an arc, wave, or straight-line;
we suggest one of the following layout orders:
#6, #4, Mallet Pole, #2, #1, #3, Mallet Pole, #5, #7
or
#1, #2, Mallet Pole, #3, #4, #5, Mallet Pole, #6, #7
QTY.
1
1
1
1
1
1
1
2
18"
Between
Chimes
4
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F
DURANGO CO 81303
TEL: (970) 375-7825
FAX: (970) 247-0856
WWW.FREENOTESHARMONYPARK.COM
11" Between
Mallet Poles
and Chimes
5
1
3
2
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
FREENOTES HARMONY PARK. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF FREENOTES HARMONY
PARK IS PROHIBITED.
7
Step 2:
After choosing your layout, excavate (9)
10" Diameter holes, at 36" deep.
Step 3 (Optional):
Pound 18" of 36" long Steel Rebar
(not provided) into the center of each hole.
This process helps with keeping the Chimes
vertical while the concrete cures. Place each
Chime and Mallet Pole into their hole over
the rebar.
Step 4:
Place each Chime and
Mallet Pole into their hole,
then pour concrete
around the poles within
0" Ground Level
the holes. Check that
everything is level. Leave
concrete to set according
10" Excavated Hole
to the concrete
manufacturer's guidelines.
If necessary, brace the
Chimes to hold them rigid
during the curing process.
Approximately (27) 80lb.
bags will be needed.
(
Chimes must be as vertical
as possible for best sound
Rebar (not provided)
)
w/ Concrete Fill
36" Hole Depth
6
8
8
CCH-INSTALL
In Ground Installation with Parts List
TITLE:
REVISION: A
SCALE: 1:28
DATE: 2/7/2018
SHEET 2 OF 3
DWG. NO.

Parts List:
ITEM NO.
1
2
3
4
5
6
7
8
9
10
Step 1:
Contrabass Chimes - Surface Mount Chime Assembly 1
Contrabass Chimes - Surface Mount Chime Assembly 2
Contrabass Chimes - Surface Mount Chime Assembly 3
Contrabass Chimes - Surface Mount Chime Assembly 4
Contrabass Chimes - Surface Mount Chime Assembly 5
Contrabass Chimes - Surface Mount Chime Assembly 6
Contrabass Chimes - Surface Mount Chime Assembly 7
Contrabass Chimes - Surface Mount Mallet Pole Assembly
3/8"-16 Wedge Expansion Anchor, 3.75"lg. SS
Determine your layout. Spacing between Chimes
DESCRIPTION
35/64" Hex Nut Cap
and Mallet Poles must be maintained per the
diagram shown to allow the Mallets to reach each
Chime. Although the Chimes can be laid out in a
variety of styles such as an arc, wave, or straight-line;
we suggest one of the following layout orders:
#6, #4, Mallet Pole, #2, #1, #3, Mallet Pole, #5, #7
or
#1, #2, Mallet Pole, #3, #4, #5, Mallet Pole, #6, #7
6"
QTY.
1
1
1
1
1
1
1
2
27
27
6
4
2
11" Between
1
Mallet Poles
and Chimes
8
3
18"
Between
Chimes
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F
DURANGO CO 81303
TEL: (970) 375-7825
FAX: (970) 247-0856
WWW.FREENOTESHARMONYPARK.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
FREENOTES HARMONY PARK. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF FREENOTES HARMONY
PARK IS PROHIBITED.
8
5
7
Step 2:
Determine installation location. Verify concrete
footing is a minimum of 132" long x 18" wide x 6" thick,
depending on the layout you go with. If the concrete
pad is at an angle, steel washers are required to act
as shims (Shims not provided). If there is not already
an existing pad, approximately (23) 80lb. bags will
be needed. Allow concrete to cure per concrete
manufacturers guidelines.
Step 3:
With two people place the Chimes and Mallet Poles
individually onto the concrete pad and mark the
center of the holes on the surface mount plates.
After you have made your marks, set aside the Chimes
and Mallet poles in order to drill for anchor holes.
With a hammer or rotary drill, drill through concrete
at marked locations. Drill to a minimum depth of 4".
A 3/8" masonry drill bit will be needed.
Step 4:
Place the Chimes and Mallet Poles back over the
drilled out holes. Insert provided anchor bolts into
aligned holes. Position anchor nut so that it is flush
with the top of the bolt. Pound anchor bolts into the
hole until the anchor washer is flush with the surface
mount base. Tighten anchor bolts until they are snug.
Cover remaining bolt sections with provided nut caps.
9
DETAIL A
SCALE 1 : 6
3/8" Drill Diameter
to a Depth of 4"
10
132"
18"
Surface Mount Installation with Parts List
TITLE:
REVISION: A
SCALE: 1:24
DATE: 2/7/2018
SHEET 3 OF 3
CCH-INSTALL
DWG. NO.