Freemie Equality, Freedom Quick Setup Manual

®
Hands Free, Concealable
Breast Pump Collection System
Quick Set-up Guide
This is intended as a reference guide,
please read entire User Manual prior to use.
Use the Freemie System only with
compatible pumps (see User Manual).
Assembly Layout
Valve
Base
Breast
Funnel
Valve
Cup
Preparing for rst use
1
MUST BOIL THESE PARTS FOR 10 MINUTES BEFORE FIRST USE ONLY FOR SECURE FIT BETWEEN PARTS.
Breast
Funnel
Clean parts with hot soapy water and rinse thoroughly after each use.
Valve
Base Cup
Hand wash valve in hot, soapy water. Rinse thoroughly.
Connecting to
your pump
See reverse side or
User Manual for
Connection Diagrams
DO NOT BOIL OR STEAM THESE PARTS:
Quick
Connector
Short Tube
T Connector Pump TubingFreemie Tubing
ENSURE ALL PARTS ARE DRY PRIOR TO USE. DO NOT STEAM STERILIZE OR USE ABRASIVES ON ANY FREEMIE COMPONENTS. STEAM MAY DAMAGE PARTS AND CAUSE THESE PARTS TO NOT FIT SECURELY.
Compatible
Your Freemie
Compatible Pump
Pressure ReducerValve
3
Before using Freemie
Practice pouring water from Freemie Cups into a storage bottle or bag before trying with pumped milk to help ensure successful transfers.
BRA FIT IS CRITICAL TO PROPER USE.
Before choosing a bra, pump with the Freemie using your hands to hold the Cups in place.
To achieve the same pressure and sensation with the Freemie Cups in your bra, it may be necessary to adjust your bra or try different bras to nd the best t for you. A sports bra or stretchy nursing bra works well for some women.
Freemie Cups can be used discreetly with proper wardrobe planning. Loose clothing with easy access and scarves will be most discreet. Before rst use in public, put water in the Cups and practice placement and removal of the Cups in your bra. This exercise will help in determining wardrobe requirements.
4
Freemie position and placement
See reverse side to connect Freemie to a compatible NUK, Medela, Hygeia, Lucina, Philips, Ameda, Freedom or Equality pump. See User Manual for connection diagrams to other compatible pumps.
12 12
Place Freemie Cup inside your bra with tubing facing upright in the
Tubing in 12 o’clock position.
12 o’clock position.
PLACEMENT AT ANY OTHER POSITION MAY
*
Milk in tubing
CAUSE MILK TO FLOW INTO TUBING.
2
Assemble Freemie Cups
1
Align Valve to Valve Base correctly
2
Push Valve onto Valve Base correctly
Correct Incorrect
Incorrect assembly of the valve will cause milk to back up into tubing
3
Insert Tubing into Valve Base
5
Ensure all connections are secure and tight to prevent loss of suction.
Align stem on Valve Base with tubing port on Funnel
Push together
Push Breast
4
Funnel and Valve Base rmly together
Align ports
6
and snap together without pinching tubing
Once assembled, gently tug on Valve to ensure it is secure
Freemie Breast Funnel should be centered over the nipple.
Keep Freemie Cups upright while pumping by sitting or standing in an upright position.
LEANING FORWARD, BENDING OVER, OR
*
RECLINING MAY CAUSE LOSS OF SUCTION OR MILK TO FLOW INTO TUBING.
To begin pumping, set suction to low and slowly adjust to your personal suction preference. See User Manual.
CAUTION: If milk ows into tubing, stop suction immediately by turning
*
off your pump or disconnecting the tubing. See User Manual.
5
Transfer milk from Freemie Cups
• Turn off pump, remove tubing from Freemie Cups.
• Carefully remove Freemie Cups from your bra.
HANDLE CUPS WITH CARE.
Milk pours out from pour spout. Placement at any other position may cause milk to ow into the tubing or leak out of cups.
Transfer milk to storage container or bottle after pumping. Pour quickly with breast funnel up.
Handwash all components that come into contact with breast milk in hot soapy water, then rinse thoroughly. Leave parts disassembled until ready for next use.
Large Port
Small Port
This side towards Freemie cup
This side towards the pump
®
Compatible Pump
Connection Diagrams
For troubleshooting, see User Manual,
or visit www.freemie.com
Spectra
M1, S1, S2, 9 Plus
Your pump
tubing
Unimom
Forte
Freemie
tubing
Quick Connector
Barrier
#FG044 Asia Pacic Connection Kit
Includes:
Freemie
tubing
Quick Connector
Short
tube
Your pump
tubing
BarrierBarrier
Short
tube
Freemie
tubing
Quick Connector
Freemie
Freedom Double Electric Pump Equality Manual Pump
Double Pumping Single Pumping
Freemie
tubing
T Connector
Pump
Short
tube
#FG022 Freedom Connection Kit
Includes:
T Connector (2)
Short tube (1)
Filter
Pump tubing
Filter (2)
Freemie
tubing
Pressure Reducer (1)
Pump
Pressure
reducer
Short tube
Freemie Tubing (4) 24”
Filter
T Connector
Pump tubing
Pump Tubing (1) 32” (80cm)
Freemie
tubing
Medela
Lactina, Symphony, Pump in Style Advanced, Personal and Pump in Style
Hygeia
EnJoye Q
Double Pumping Single Pumping
Freemie
tubing
Pump
#FG021 Standard Connection Kit
Includes:
Quick Connector (3)
Freemie Tubing (4) 24”
REPLACE VALVES AND/OR FILTERS APPROXIMATELY EVERY 3 MONTHS.
Medela, Lactina, Symphony and Pump in Style are trademarks of Medela AG Corporation Switzerland. endorse and is not afliated with Freemie Collection Cups or DAO Health. Hygeia, EnJoye, and Q are trademarks of Hygeia. Hygeia does not endorse and is not afliated with Freemie Collection Cups or DAO Health. Philips and Avent are trademarks of Royal Philips Electronics of the Netherlands. Ameda and Purely Yours are trademarks of Ameda. Lucina and Melodi Prime are trademarks of Lucina. trademark of Unimom. Medical AG, Switerland. Philips, Ameda, Lucina, Spectra, Unimom, Eveno and Ardo do not endorse and are not afliated with Freemie Collection Cups or DAO Health. PO37 (H)
Eveno is a trademark of Eveno Feeding, Inc. Ardo and Calypso are trademarks of Ardo
Freemie
tubing
Quick
Connectors
Your pump
tubing
Freemie
tubing
Quick
Connector
Pump
Your pump
tubing
Medela does not
Spectra is a trademark of Spectra UnzinMedicare Co. Unimom is a
Philips
AVENT Double Electric Breast Pump
Ameda
Lucina
Purely Yours Melodi Prime Double
Electric Breast Pump
Eveno
Advanced Double Electric
Single Pumping Double Pumping
Freemie
tubing
Short
tube
Quick Connector
Barrier
Pump
Pump
Quick
Connector
Barrier
Your pump
tubing
The Large Port side (with white membrane inside) of the barrier connects to short tubing, then to the Quick Connector, and then to the Freemie Cup clear tubing. The Small Port side of the Barrier connects to the Pump Tubing. NOTE: Freemie tubing ts inside the Quick Connector.
#FG020 Philips AVENT / Ameda / Lucina Pump Connection Kit
Includes:
Barrier (2)
Short tube (4)
Quick Connector (4)
Freemie
Proper orientation of the barrier
Freemie Tubing (2) 24”
tubing
Ardo
Calypso
Quick
Connector Short tube
Your pump
tubing
Loading...