![](/html/18/1826/1826ecc1d31bb3abfc549cca7eb6e425971bbd68a61e39d8bcf8dea025133c58/bg1.png)
®
Hands Free, Concealable
Breast Pump Collection System
Quick Set-up Guide
This is intended as a reference guide,
please read entire User Manual prior to use.
Use the Freemie System only with
compatible pumps (see User Manual).
Assembly Layout
Valve
Base
Breast
Funnel
Valve
Cup
Preparing for rst use
1
MUST BOIL THESE PARTS FOR
10 MINUTES BEFORE FIRST
USE ONLY FOR SECURE FIT
BETWEEN PARTS.
Breast
Funnel
Clean parts with hot soapy water and
rinse thoroughly after each use.
Valve
Base Cup
Hand wash valve
in hot, soapy water.
Rinse thoroughly.
Connecting to
your pump
See reverse side or
User Manual for
Connection Diagrams
DO NOT BOIL OR STEAM
THESE PARTS:
Quick
Connector
Short
Tube
T Connector Pump TubingFreemie Tubing
ENSURE ALL PARTS ARE DRY
PRIOR TO USE. DO NOT
STEAM STERILIZE OR USE
ABRASIVES ON ANY FREEMIE
COMPONENTS. STEAM MAY
DAMAGE PARTS AND CAUSE
THESE PARTS TO NOT FIT
SECURELY.
Compatible
Your Freemie
Compatible Pump
Pressure
ReducerValve
3
Before using Freemie
Practice pouring water from Freemie Cups into a storage
bottle or bag before trying with pumped milk to help
ensure successful transfers.
BRA FIT IS CRITICAL TO PROPER USE.
Before choosing a bra, pump with the Freemie using your hands to hold the
Cups in place.
To achieve the same pressure and sensation with the Freemie Cups in your
bra, it may be necessary to adjust your bra or try different bras to nd the
best t for you. A sports bra or stretchy nursing bra works well for some
women.
Freemie Cups can be used discreetly with proper wardrobe planning. Loose
clothing with easy access and scarves will be most discreet. Before rst use
in public, put water in the Cups and practice placement and removal of the
Cups in your bra. This exercise will help in determining wardrobe
requirements.
4
Freemie position and placement
See reverse side to connect Freemie to a compatible NUK, Medela,
Hygeia, Lucina, Philips, Ameda, Freedom or Equality pump. See User
Manual for connection diagrams to other compatible pumps.
12 12
Place Freemie Cup inside
your bra with tubing
facing upright in the
Tubing in
12 o’clock
position.
12 o’clock position.
PLACEMENT AT ANY OTHER POSITION MAY
*
Milk in tubing
CAUSE MILK TO FLOW INTO TUBING.
2
Assemble Freemie Cups
1
Align Valve to Valve Base correctly
2
Push Valve onto Valve Base correctly
Correct Incorrect
Incorrect assembly of the valve will
cause milk to back up into tubing
3
Insert Tubing into Valve Base
5
Ensure all connections
are secure and tight to
prevent loss of suction.
Align stem on
Valve Base with
tubing port on
Funnel
Push
together
Push Breast
4
Funnel and
Valve Base
rmly
together
Align ports
6
and snap
together
without
pinching
tubing
Once
assembled,
gently tug
on Valve to
ensure it is
secure
Freemie Breast Funnel should be centered over
the nipple.
Keep Freemie Cups upright while pumping
by sitting or standing in an upright position.
LEANING FORWARD, BENDING OVER, OR
*
RECLINING MAY CAUSE LOSS OF SUCTION
OR MILK TO FLOW INTO TUBING.
To begin pumping, set suction to low and slowly adjust to your
personal suction preference. See User Manual.
CAUTION: If milk ows into tubing, stop suction immediately by turning
*
off your pump or disconnecting the tubing. See User Manual.
5
Transfer milk from Freemie Cups
• Turn off pump, remove tubing from Freemie Cups.
• Carefully remove Freemie Cups from your bra.
HANDLE CUPS WITH CARE.
Milk pours out from
pour spout. Placement at any other position may
cause milk to ow into the tubing or leak out of cups.
Transfer milk to storage container or bottle after
pumping. Pour quickly with breast funnel up.
Handwash all components that come into contact with
breast milk in hot soapy water, then rinse thoroughly.
Leave parts disassembled until ready for next use.
![](/html/18/1826/1826ecc1d31bb3abfc549cca7eb6e425971bbd68a61e39d8bcf8dea025133c58/bg2.png)
Large
Port
Small
Port
This side towards
Freemie cup
This side
towards
the pump
®
Compatible Pump
Connection Diagrams
For troubleshooting, see User Manual,
or visit www.freemie.com
Spectra
M1, S1, S2, 9 Plus
Your pump
tubing
Unimom
Forte
Freemie
tubing
Quick
Connector
Barrier
#FG044 Asia Pacic Connection Kit
Includes:
Freemie
tubing
Quick
Connector
Short
tube
Your pump
tubing
BarrierBarrier
Short
tube
Freemie
tubing
Quick
Connector
Freemie
Freedom Double Electric Pump
Equality Manual Pump
Double Pumping Single Pumping
Freemie
tubing
T Connector
Pump
Short
tube
#FG022 Freedom Connection Kit
Includes:
T Connector
(2)
Short tube
(1)
Filter
Pump
tubing
Filter
(2)
Freemie
tubing
Pressure Reducer
(1)
Pump
Pressure
reducer
Short
tube
Freemie Tubing
(4) 24”
Filter
T Connector
Pump
tubing
Pump Tubing
(1) 32” (80cm)
Freemie
tubing
Medela
Lactina, Symphony, Pump in Style Advanced,
Personal and Pump in Style
Hygeia
EnJoye
Q
Double Pumping Single Pumping
Freemie
tubing
Pump
#FG021 Standard Connection Kit
Includes:
Quick Connector
(3)
Freemie Tubing
(4) 24”
REPLACE VALVES AND/OR FILTERS APPROXIMATELY EVERY 3 MONTHS.
Medela, Lactina, Symphony and Pump in Style are trademarks of Medela AG Corporation Switzerland.
endorse and is not afliated with Freemie Collection Cups or DAO Health. Hygeia, EnJoye, and Q are trademarks of
Hygeia. Hygeia does not endorse and is not afliated with Freemie Collection Cups or DAO Health. Philips and Avent
are trademarks of Royal Philips Electronics of the Netherlands. Ameda and Purely Yours are trademarks of Ameda.
Lucina and Melodi Prime are trademarks of Lucina.
trademark of Unimom.
Medical AG, Switerland. Philips, Ameda, Lucina, Spectra, Unimom, Eveno and Ardo do not endorse and are not
afliated with Freemie Collection Cups or DAO Health.
PO37 (H)
Eveno is a trademark of Eveno Feeding, Inc. Ardo and Calypso are trademarks of Ardo
Freemie
tubing
Quick
Connectors
Your pump
tubing
Freemie
tubing
Quick
Connector
Pump
Your pump
tubing
Medela does not
Spectra is a trademark of Spectra UnzinMedicare Co. Unimom is a
Philips
AVENT Double
Electric Breast Pump
Ameda
Lucina
Purely Yours Melodi Prime Double
Electric Breast Pump
Eveno
Advanced
Double
Electric
Single Pumping Double Pumping
Freemie
tubing
Short
tube
Quick
Connector
Barrier
Pump
Pump
Quick
Connector
Barrier
Your pump
tubing
The Large Port side (with
white membrane inside) of
the barrier connects to short
tubing, then to the Quick
Connector, and then to the
Freemie Cup clear tubing. The
Small Port side of the Barrier
connects to the Pump Tubing.
NOTE: Freemie tubing ts
inside the Quick Connector.
#FG020 Philips AVENT / Ameda / Lucina Pump Connection Kit
Includes:
Barrier
(2)
Short tube
(4)
Quick Connector
(4)
Freemie
Proper orientation
of the barrier
Freemie Tubing
(2) 24”
tubing
Ardo
Calypso
Quick
Connector
Short tube
Your pump
tubing