Freemie Single or Double, Breast Pump Collection System User Manual

IMPORTANT
Read this manual prior to use
User Manual
Breast Pump Collection System
Hands-free, Concealable
Pump anytime, anywhere, around anyone.
This Freemie Breast Pump Collection System is a single user, reusable system that you may use throughout the first year of your baby’s life, and beyond. This manual contains important information for the proper sanitization, use and care of your Freemie system. Please visit our website, www.Freemie.com, for customer service and all your spare parts needs.
Single or Double
Use only with an approved compatible pump
Compatible
*pump not included
Table of Contents
Important Safety Instructions
Do’s And Don’ts ………………………………………………………………………… 2
Freemie Collection System
Parts Included……………………………………………………………………………… 3 Preparing Freemie For First Use………………………………………………………… 4 Assembling Freemie Cups ……………………………………………………………… 5
Positioning within Your Bra
Connecting To Your Compatible Pump ……………………………………………… 6 The Perfect Bra Fit………………………………………………………………………… 7 The 12 O’clock Position ……………………………………………………………… 8
Pumping with Freemie
Adjusting Your Pump And Sitting Upright ……………………………………………… 9 When You Are Interrupted ……………………………………………………………… 10
Disconnecting and Transferring Milk
When You Are Done Pumping ………………………………………………………… 11 Pouring Milk Into A Container ………………………………………………………… 12 Cleaning …………………………………………………………………………………… 12
Caring for Your Freemie System
Tubing Care ……………………………………………………………………………… 13
Troubleshooting Tips
Breasts Not Emptying …………………………………………………………………… 14 Loss of Suction ………………………………………………………………………… 14 Milk In Tubing ……………………………………………………………………………… 14 Need To Stop Or Break Suction ………………………………………………………… 14
Compatible Pump Connection Diagrams
Freemie Freedom ………………………………………………………………………… 15 Freemie Equality ………………………………………………………………………… 16 Medela …………………………………………………………………………………… 17 Philips Avent ……………………………………………………………………………… 18 Ameda …………………………………………………………………………………… 19
Spare Parts & Customer Service ………………………………………………………… 20
Indications for use:
The Freemie Breast Pump Collection System is intended to be used in conjunction with an approved powered breast pump for the purpose of expressing human milk.
This is a single user product. Use by more than one person may present a health risk and void the warranty.
READ ALL INSTRUCTIONS
pump efficiently
Single or double pumping
Freemie can be used for single or double pumping as desired.
pump and relax
Home
Simultaneously pump or passively collect milk while breastfeeding to catch and store every precious drop.
Work
Pump discreetly at your work station without ever undressing.
Travel
Travel with Freemie to express milk on the go whenever a private place can’t be found.
Important Notice
If you have any concerns about your health, or experience any pain while nursing or using any breast pump, consult your health care or lactation professional immediately. Dr. Dao, Dao Health and Freemie User Manual do not give medical or lactation advice, or make diagnoses.
Not made with BPA, DEHP, or natural rubber latex
Spill Guard Flat Base
8 Ounce Capacity
Spill Guard Finger Grip
Easy Pour Spout
Comfortable Breast Funnel
Quick Connector
pump while bonding
Freemie can be used to pump milk while breastfeeding. Place baby on one breast and Freemie on the other.
pump the freemie way
• Use Freemie only with compatible pumps.
• Keep Freemie in an upright position while pumping.
• Transfer milk to a proper storage container right after pumping.
• Use Freemie when you must express milk discreetly and hands-free underneath normal clothing.
• Use Freemie only as often and only as long as you normally breastfeed your baby. Consult a lactation professional if you have questions about your milk supply.
• Use with a bra or manually hold in place.
• Keep out of reach of infants and children. Freemie has small parts that can be a choking hazards.
• Consult your lactation professional if you have questions about whether Freemie is appropriate for you or to help determine the correct funnel size for you.
Do
Do Not
WARNING:
USE ONLY WITH FREEMIE COMPATIBLE PUMPS. USE WITH UNAPPROVED PUMPS MAY
CAUSE INJURY TO YOU OR DAMAGE YOUR PUMP. MISUSE MAY VOID WARRANTY.
SEE COMPATIBLE PUMPS ON PAGES 15 - 19.
Important Safety Instructions
• Do not bend forward or recline while using Freemie, and avoid excessive movement. This could cause leakage, loss of suction, and milk to flow into tubing.
• Do not overfill Freemie cups, as this may cause milk to flow into the tubing. You may hear a faint bubbling sound as the Freemie is filling. There is a risk of overfilling if you are hearing impaired or use Freemie in a noisy environment.
• Do not use Freemie if you must watch your milk ejection reflex or manually massage your breasts while pumping to ensure that they are completely empty.
• Do not share. Freemie is a personal use item.
• Do not use Freemie in any situation that may be unsafe should you become drowsy or distracted during milk expression.
• Do not use Freemie for simultaneous breastfeeding and pumping with compromised infants without first consulting your healthcare or lactation professional.
• Do not continue to use Freemie if you experience pain or discomfort in the breast or nipple while pumping.
2
Breast Funnel
(2)
25mm - FG024 28mm - FG025 32mm - FG026
Valve Base
(2) FG029
Two cup assemblies included with each Freemie Breast Pump Collection System.
Natural Shape Cup
(2) FG027
Valve
(3) FG030
Freemie Breast Pump Collection System
Additional funnel sizes available at www.Freemie.com.
Parts included:
Pump Connection Kits
For connecting to other approved compatible pumps, use proper Connection Kits. For further information on connecting to your pump, see the Pump Connection Diagrams.
Medela Pumps
FG022 Freemie Freedom Double Electric Pump Page 15 FG023 Freemie Equality Manual Pump Page 16 FG020 Philips Avent Page 18 FG020 Ameda Page 19
Other Compatible Pumps
Compatible
Kit #
Compatible Pump
Diagram
FG021 Lactina, Symphony, Pump in Style Page 17
Kit #
Medela Pumps
Diagram
Connection kit for Medela pumps included in box.
3
Sanitize Parts
Disassemble and clean Freemie prior to first use. Some parts must be boiled initially.
Unsnap cup from funnel Pull valve base off funnel Remove valve from
valve base
Boil these parts for 10 minutes to sanitize
Do NOT boil these parts
• Do not let parts sit on the bottom of the boiling pot. Parts should float freely.
• Remove from water and allow to dry completely.
Parts must be thoroughly dry before use.
• Hand wash valve in hot, soapy water and rinse. Allow parts to cool and dry completely before use.
Do not boil or steam sterilize tubing, valves,
or connectors.
• Quick Connector can be washed by hand when necessary.
Preparing Freemie for First Use
4
5
Always wash hands prior to assembling Freemie. All parts must be completely dry, correctly positioned, and secure.
Place Valve onto Valve Base
Inspect the device before each use for signs of wear or damage and replace parts if signs of wear are noted.
Make sure Valve is straight
Correct
Incorrect
Keep stem aligned with tubing port
Push Breast Funnel and Valve Base firmly together
Align ports and snap together
Gently tug on Valve to ensure it is secure
1
2
3
5 6
Insert Tubing into Valve Base
Push to ensure tubing is securely in port
7
8
4
Push together
Assembling Freemie Cups
Loading...
+ 15 hidden pages