freedom showers 3838, 4836, 5050, 5430 LR, 5436 LR Installation Instructions

...
Page 1
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Tools/materials you might need for proper installation
• hammer
• drill with phillips screw bit
• 1/2” notched trowel
• 1/8” drill bit
• spatula
• grease pencil (china marker)
• auger mixing tool for drill
• caulking gun
• 4’ level
• 2’ level
• nails
• (50+) 1 1/4” wood screws
For best results, please read and follow all directions carefully.
1. Avoid exposure to weather. Product carton is not waterproof. Carton exposed to rain or snow may result in accumulated water penetrating the back laminates of the shower pan and soak the glassed in reinforcement supports causing bulges in the applied acrylic surface.
2. Most handling damage is the result of impact blows to
the back of the berglass units.
3. Never drag this berglass product on any surface. Always
carry the pan or use a two wheel dolly.
4. Never drop the berglass shower pan from any height,
not even an inch or stress cracks are likely to occur.
5. Placing objects inside the unit can cause scratches or nicks
to the nished surface. Do not use the shower pan as a
trash receptacle! Always place a drop cloth or cardboard on
the oor when working inside the shower.
6. Never clean applied acrylic surface with metal tools of any kind, including razor blades.
PLANNING YOUR INSTALLATION
1. Review the Framing Diagrams in Figure 1. Modify existing
framing if required. For new construction, build framing structure in accordance with product dimensions and notes
shown in the Framing Diagrams. The two wall Framing Diagram is for the 6060 3P two wall shower only.
BRIEF OVERVIEW Please read instructions before beginning the installation.
Note: Unit will not install properly if framing pocket is not square and of proper size. The dimensions shown in the
• solid wood ooring adhesive or 100%
• two gallons of water - for mixing
• tube of white bathroom caulking
• (2) tubes of 100% clear silicone
• (3) 8’ 2x4s
• (1) 8” long 2x4
• (1) 24” long 2x4
silicone adhesive - (2) one gallon
buckets per shower
bedding compound and water test around drain
caulking
FRAMING DIAGRAMS are 1/4” larger than the size of the
shower. This product is manufactured to tight specications.
The 1/4” over sizing is for maneuvering and installation ease. If 1/4” over is not reasonable, sizing closer to the product actual dimensions is allowable.
When trial tting the shower, use a level to conrm the parts
are level and plumb. If any gaps are present between the
shower and framing, use furring strips to ll the gaps. If the walls and oor are not level, there may be an excessive gap
at the seams. The unit is designed to allow an 1/8” gap at the seams.
2. The shower base will be installed, leveled, and fastened to
the framing before the walls are installed. It is essential the framing pocket be square and plumb for the unit to install
properly. The oor also must have no voids or out of level
conditions. If these are present, they must be corrected before installation. Floor leveling compound can be purchased at a local home improvement store. Make sure the area is completely dry.
3. Following the shower pan installation, place the back wall
sections, then the side walls. The par ts are indexed to one another by a slot and pin connection system. The parts are
pushed tight together before connection to the framing
pocket is made. To have a successful installation, two persons
are required.
4. Plan for the location of the shower water control valve.
Note if planning to install the control valve in the back wall of the shower with a two piece back wall, consider the location of the seam in the wall. The control valve must be located at
a height where the seam and mounting ange do not cause a conict with placement of the control valve, or water supply
lines. These considerations are not necessary if installing on the one piece back wall, or side wall. Plan for routing the water supply lines to the control valve installation location.
Installation Instructions
• (2) large wiping cloths
• self-caulking shower drain tting
• Epoxy - for optional EasyBase™
installation
For INSTALLATION USING
EPOXY ADHESIVE refer to last
page of instructions.
Page 2
Multi-Piece Sectional Product
Marketing Materials
Pricing
3
FRAMING DIAGRAMS
C
C
A B
C D
38 7/8” 48 1/4”
60 1/4” 60 1/4” 60 1/4”
60 1/4”
60 1/4” 60 1/4” 60 1/4”
60 1/4” 62 5/8”
62 5/8”
62 5/8” 38 1/2” 19 3/8”
31 5/16”
32 1/2” 16 3/8”
30 1/8” 61 1/4” 30 1/8”
30 1/8”
49 1/4”
24 1/8”
8 9/16”
37 1/8”
18 3/4”
8 9/16” 30 1/8” 37 1/4”
18 1/8”
33 5/8” 15 3/8”
30 1/8” 33 5/8” 15 1/8”
8 9/16” 31 1/4”
15 1/8”
30 1/8”
31 1/4”
15 1/8”
24 1/8”
37 1/4”
18 1/8”
19 7/16”
38 5/8”
19 1/8”
50 1/4” 25 1/8” 50 1/8” 25”
54 1/4” 8 5/8” 31” 15” 54 1/4” 8 5/8” 36 7/8” 18 5/8”
www.freedomshowers.com
Installation Instructions
FRAMING DIAGRAMS
A B C D
3838
3838
4836
4836
6030
5050
6030 L-R
5430 LR
6033 C
5436 LR
6033 L-R
6030 C
6036
6030 LR
6036 L-R 6048
6033 C
6060
6033 LR
6036 C
6036 LR
6048
6060
6232 C
6232 LR
6238
38 7/8” 19 7/16” 38 5/8” 19 1/8”
48 1/4” 24 1/8” 37 1/4” 18 1/8”
C
50 1/4” 25 1/8” 50 1/8” 25”
54 1/4” 8 5/8” 31” 15”
54 1/4” 8 5/8” 36 7/8” 17 5/8”
60 1/4” 30 1/8” 31 1/4” 15 1/8”
C
60 1/4” 8 9/16” 31 1/4” 15 1/8”
60 1/4” 30 1/8” 33 5/8” 15 1/2”
60 1/4” 8 9/16” 33 5/8” 15 3/8”
6232
60 1/4” 30 1/8” 37 1/4” 18 1/8”
6238
60 1/4” 8 9/16” 37 1/8” 18 3/4”
5050
60 1/4” 30 1/8” 49 1/4” 24 1/8”
5430
60 1/4” 30 1/8” 61 1/4” 30 1/8”
5436
62 5/8” 31 5/16” 32 1/2” 16 3/8”
62 11/16” 8 9/16” 32 1/4” 16”
62 5/8” 62 5/8” 38 1/2” 19 3/8”
A B
38 7/8” 48 1/4”
60 1/4” 60 1/4” 60 1/4”
60 1/4”
60 1/4” 60 1/4” 60 1/4”
60 1/4” 62 5/8”
62 5/8” 50 1/4” 25 1/8” 50 1/8” 25”
54 1/4” 8 5/8” 31” 15” 54 1/4” 8 5/8” 36 7/8” 18 5/8”
19 7/16”
24 1/8” 30 1/8” 8 9/16” 31 1/4”
30 1/8” 33 5/8” 15 1/8”
8 9/16” 30 1/8” 37 1/4” 8 9/16” 30 1/8”
30 1/8” 61 1/4” 30 1/8” 31 5/16”
62 5/8” 38 1/2” 19 3/8”
C D
38 5/8” 37 1/4”
31 1/4”
33 5/8” 15 3/8”
37 1/8” 49 1/4”
32 1/2” 16 3/8”
19 1/8”
18 1/8” 15 1/8” 15 1/8”
18 1/8” 18 3/4”
24 1/8”
Note: Unit will not install properly if framing pocket is not square and of proper size. The dimensions shown in the FRAMING DIAGRAMS are 1/4” larger than the size of the shower pan. This product is manufactured to tight specifications. The 1/4” over sizing is for manuvering and installation ease. If 1/4” over is not reasonable, sizing closer to the product actual dimensions is allowable.
Page 3
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
5. In the installation location, the drain opening in the oor should have a 6” core for the drain pipe, and a 10” x 10” x 1/2” deep recess in the sub oor. (The drain core must be blocked when lled with Thin-Set or 100% silicone adhesive). The 10” x 10” x 1/2” deep recess is required to assure proper drainage.
See Detail of Drain Core Area
6. Check the outside of the package for visible shipping damage. If damage is noted, contact your supplier before proceeding with the installation.
7. Locate accessories if any were ordered. They will be
packaged in the pan box. Remove those and store them in a safe location for easy retrieval.
8. Identify each package and its contents. The label on the box
is clearly marked indicating a shower pan and wall panels.
Installation Instructions
Figure 2A
Figure 2B
INSTALLATION INSTRUCTIONS
1. Prepare the installation area by sweeping the area
completely clean.
2. Framing pocket must be sized according to the information
provided in the Framing Diagram. It is recommended that
the front studs at each side be doubled for added strength. Framing must be extremely square and plumb in order to accomplish a successful installation.
3. Install hot and cold water supply lines with the control valve. Mount to the framing.
4. It is extremely important that the oor area intended for the installation be at and level. Any areas over 1/8” out-of-
level will prevent the installation from being successful. If an
area out more than 1/8” is found, oat the oor area with a oor leveling compound. This material must be placed and
cured (dry) before proceeding with the shower installation.
5. A special note: During handling and transport, the product may be slightly bent. It is very important that the seam side of each wall, and the threshold of the pan does not have any bow or bend. This product is engineered with materials that allow for the sections to be pressed back to the normal and straight factory form that is intended.
As each section is removed from the packaging, use a straight edge to check the straightness of the wall sections and of the threshold. An example of checking the threshold is illustrated
Figure 2C
Figure 3
Figure 4
Page 4
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
in Figure 2A. Check all the parts, and if not straight, follow the procedures outlined below to bring the parts back into the intended condition.
In the event they are not straight to 1/16”, pressure can be applied to the top side of the material. This can be
accomplished by placing blocks under the two extreme corners.
Always place a soft rag on the nished surface where it
contacts the wood blocks, and under your feet to avoid
damaging the nish.
Gently step on this area and allow your body weight
(Up to 250 pounds), to ex the material back straight. Conrm straightness, repeat if necessary until +/- 1/16”
is accomplished. Figures 2B and 2C
A complete dry t for the shower base and walls is recommended. A dry t in this instance is dened as
securing the sections to the studs with no silicone and
minimal screws to conrm a good t, and the framing accommodates the sections. To achieve a dry t installation, proceed with steps 6 through 23 without using the silicone, oor adhesive and minimal screws to secure to the
framework.
Installation Instructions
Figure 5
Figure 6
Once the dry t has been done and the t conrmed,
disassemble the components. Resume step 5 and follow each step carefully.
6. Carefully measure the framing pocket to assure it is of proper size for the unit to be installed. Refer to dimensional information in the Framing Diagrams in Figure 1.
Figure 7
7. Check the framing pocket for square. Check to assure
the vertical studs are plumb. To have tight seams where
the parts meet, it is very important that the framing pocket be exceptionally square and plumb.
Check for square by holding a measuring tape from the back left corner to the front right corner, as shown in Figure 4. Repeat for the other side. If both dimensions are the same, the framing is square. Adjust if necessary.
8. The next step is to dry t the shower pan to the studs and conrm the drain location.
The better t of the pan, the better all wall parts will
assemble as intended with minimal gaps at the seams.
Figure 8
Page 5
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Note in Figure 5 the two installers have placed the shower
pan on the oor, and are pushing it into the installed position. One of the installers is using a short piece of 2 x 4 wood to hold the front of the shower pan off the oor. This will assist
in moving the pan into the installed position while preventing
chipping the front edge if it were to slide along the sub oor.
After the pan is set, ll any gaps between the mounting ange and the framing with wood shims or furring strips to achieve solid contact. The ange must be in contact with
the studs along all sides.
The back corners of the shower pan should be in
contact with the framing, as seen in Figure 7. Shim these areas if required.
9. Once the shower pan is put into place and t is conrmed, draw a pencil line on the sub oor indicating the
front point of the threshold of the pan. See Figure 8
Installation Instructions
Figure 9A
Figure 9B
Place a piece of cardboard in the oor of the shower to protect the oor during the additional steps of installation. There is a cut out for this on the pan box.
10. Conrm the pan is level by using a long level on top of the threshold, and along the sides and back.
Note the level is used on the same horizontal surface that has the pins. This will be important to allow the wall panels
to t correctly. See Figures 9A and 9B
If the pan is not level, shim the appropriate areas to achieve
level. Do not shim more than 1/8”. If shimming over 1/8” is required, remove the pan and correct the sub-oor area by “oating” a oor leveling compound.
11. Drill holes through the mounting anges into each framing stud. These holes should be drilled using a 1/8” drill bit. See Figure 10
Note: Plan on using at or pan head screws to secure the
shower pan. An 1/8” gap is provided in the shower design to account for the screw heads. This gap will allow clearance so the walls may assembled to the shower pan.
12. The next step is to permanently install the shower
pan. A helpful tip to make this easier is to rotate the pan upward and lean against the back framing studs of the
Figure 10
Figure 11
Page 6
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
pocket. This will remove the pan from the work zone without removing it from the stud pocket. Do not
secure the pan to the studs at this point because you may need to reach around the pan as you install the
drain tting detailed in the next step. Make sure pan is
angled enough so it will not fall.
IF USING EPOXY ADHESIVE refer to last page of instructions
13. Install the drain tting on the shower pan. Apply a bead of 100% silicone caulking around the recessed molded drain area on the nished side of the pan.
Remove the nut and all gaskets from the drain body.
Slip the threaded shank of the drain body through the
hole. Follow the instructions provided with the drain
tting to install the gaskets in the proper location. When
all gaskets and locknut are in place on the bottom side of the shower, tighten the nut to secure the shower drain assembly. From the top side of the drain assembly, remove the rubber caulking gasket located on the
inside of the drain tting. This will allow the drain pipe to slip through the drain tting on the shower.
Installation Instructions
Figure 12
A diagram of a typical drain assembly is shown in this manual.
Wipe away any excess caulking that may have squeezed out on the inside of the pan.
Now secure the pan in the upright position to the
back framing. Use a piece of scrap 2 x 4 lumber to temporarily secure it. See the example in Figure 12.
14. A solid wood oor adhesive or 100% silicone adhesive will be used to “glue” the bottom side of the shower pan to the sub oor. The following steps will
detail the appropriate steps to accomplish this.
Figure 13A
15. Clean the sub-oor thoroughly, wiping away all lose
debris. Wipe up any moisture. Never use adhesive on a dirty or damp surface.
16. To secure the shower pan to the oor a solid wood oor adhesive must be applied to the entire sub oor area where the shower pan will rest - 3/8” thick and 3”
apart.
Figure 13B
Page 7
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Using a 1/2” notched trowel, apply adhesive evenly over the
pan contact area. Bring the adhesive up to the threshold pencil mark and also make sure the adhesive will be in
contact with the back side of the pan. The long edge of
the trowel may be needed to get the adhesive to the far back of the contact area where the pan is resting against the framing studs in a vertical position. (Pan not shown in Figures 13 A and B).
After the adhesive is troweled over the sub oor, use a
spatula to wipe the adhesive over the entire area where
the pan will sit. The exception will be the drain box area. This area will be lled with thin-set non shrink mortar. Do not ll this area above the oor line and do not spill any of
this thin-set material onto the contact adhesive. See Figure 13B
Non shrink thin-set mortar can be purchased at any local home improvement store. Please follow the mixing directions on the bag.
Installation Instructions
Wood
Figure 15
In this step, apply the adhesive to the at oor area and ll the boxed area around the drain pipe with the Thin-Set
mortar.
17. After the adhesive and thin-set materials are in place, rotate the pan back into place for installation.
(Hint) In order to reach the pan without stepping on the adhesive, place a short piece of wood over the drain area. Use
this to step on to remove the 2 x 4 that is holding the pan
against the back framing. See Figure 15
NOTE: The working life of the ooring adhesive is roughly
one hour. (Refer to the label on the adhesive for actual working time). After step 16 is complete, the entire installation process though step 23 must continue. If for any reason the installation cannot be completed within the working time of the adhesive, after step 16, jump ahead to step 23.
Rotate the pan back to the horizontal position. As you
lower the pan to the sub oor, align the drain pipe with the drain tting, and with the pencil mark at the front of the
threshold.
When the pan is seated into the adhesive, place the
cardboard on the shower oor for protection. Thoroughly walk around in the shower. This will assist in seating the pan
into the adhesive.
Floor Level To Drain - No Humps
Figure 16
Figure 17A
Figure 17B
2 Ft. Level
Page 8
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Attach the pan to the studs by installing the at top/pan head screws through the holes drilled into the ange. Snug the screws up tight so the screw heads will be clear
of the side wall panels for assembly. Use care not to
overtighten to the point that causes ange breakage.
18. Before installing the walls, conrm the ledges
where the walls sit are level. Check with a long level as shown in Figure 16. If there is an out of level condition, remove screws and adjust as required.
19. Before the adhesive cures, conrm the oor slope to the drain has been maintained. To do this, use a 2 foot level
at various points around the drain to the adjacent wall to check for draft. Make sure there is a downward slope to the drain in all directions around the drain. Visually inspect
the oor to be sure there are no humps or dips that could
cause improper drainage.
See Figure 17A and 17B.
20. The next step will be to place the wall panels on the pan. The back wall will be installed rst. If the water control
valve is in the back wall, carefully measure and mark the location on the surface of the wall panel. If installing in a shower with a two piece back wall, the valve probably will be installed through the lower wall panel. Make certain the
valve does not conict with the mounting ange or seam. Read the installation
instructions provided by the valve manufacturer. Before the
Trial t, carefully drill the valve hole (s) in the panel. When drilled,dry Trial t the back wall panel (s) on the shower pan to test the t.
Conrm the gap where the wall seats to the pan is 1/8” or less. Make sure the seam for the two piece wall is also 1/8”
or less. Adjust the valve hole size and location if required.
Lift the wall panel with the valve hole away. Complete the valve installation and connection to hot and cold water supply at this time. Also complete shower supply
connection. Strap pipes to framing if required. This is the
last access to the plumbing before the wall is permanently installed.
21. If all ts are good, proceed with the installation of the the back wall. The installation procedures described in this
step apply for installation of one or two piece back walls.
Wipe clean the ledges on top of the pan. Apply a
Installation Instructions
continuous bead of 100% RTV silicone caulking along the back ledge of the pan where the back wall will sit. The
bead should be placed at the middle of the ledge, and be
3/8” wide. The bead should go completely around each
alignment pin.
There are slots on the underside of the wall. There are
alignment pins in the pan that will insert into the slots on
the bottom of the wall. See the detail in Figure 19.
The lower section of the back wall is the panel with a
single, molded soap dish. Lift this panel up and carefully lower it onto the back ledge on the pan.
Push the wall panel down to seat it in the caulking.
Check the t for level and plumb.
Note to installer: There is a difference having the bubble between the lines and a plumb wall. The wall must be VERY plumb or a gap larger than 1/8” will be present where the side walls mate the back wall. Use wood shims
or furring strips to ll any space between the back wall ange and the studs.
Align the wall section where it meets the shower pan so it is centered on the pan, and install wood shims or furring strips if necessary.
Pre-drill the mounting anges. Attach the wall with screws through the back wall ange into the framing. Be sure the wall panel remain level and plumb. (For the 4836 4 piece,
this step will apply for the entire back wall as one piece).
22. For ve piece units, the next step is to place the top
section of the back wall. Clean the back ledge and apply
a continuous bead of 100% RTV silicone caulking along
the ledge of the back wall where the top part of the wall
will sit. The bead should be 3/8 wide and placed at the
middle of the ledge. It should go completely around each alignment pin.
Lift the top back wall panel and set it on top of the lower
wall. Press the panel down to seat in the caulking. The
top and bottom wall panels must be level and plumb.
Shim if necessary. The seam between the panels should be no more than 1/8”. Pre-drill holes and attach with screws along the top back ange into the framing studs.
Make sure the two wall panels are in alignment and are level and plumb. Place level or straight edge on both
vertical ange where the wall will mate to the back wall and check to assure there are no gaps. (For the 4836
Page 9
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
four piece which has a single piece back wall panel, skip this step).
23. Side wall installation. The side wall panels are slotted on the bottom. The alignment pins in the pan will index with these slots. The slots will allow the side wall panel to slide
about one inch to meet the back wall panel.
If the water control valve is located on one of the side
walls, it is important to dry trial t that panel rst. Carefully
measure and mark the location of the valve on the surface of the side wall. Read the installation instructions provided by the valve manufacturer. Carefully drill the valve hole(s).
Trial t the side wall panel to the shower pan. Wipe clean the side ledge. This next step is a two person job.
Lift the side wall panel and set it on the ledge. Set the panel
so it is within one inch of the vertical back wall seam. Make sure the pins in the pan index with the slots on the bottom
of the wall. Clear your ngers and slide the wall panel
toward the back wall. Make sure the alignment pins in the back wall index into the holes on the side wall.
When seated, the seam should have a minimal gap of
1/8” or less. If not, push the end of the side panel until the vertical seam closes. When in place, check the t of the
valve hole. Adjust size and location if required.
When the t is good, lift the wall panel away. Complete
the valve installation and connection to hot and cold water supply at this time. Also complete shower supply
connection. Strap pipes to framing if required. This is the last
access to the plumbing before the wall is permanently installed.
Clean the side ledge and apply a continuous 3/8” bead of 100% RTV silicone caulking along the entire length of the
mating ledge of the shower pan. Apply the caulk completely around each alignment pin.
Clean and apply a continuous 3/8” bead of 100% RTV
silicone caulk along the entire length of the vertical surface of the back wall where the side wall panel mates to the back wall. Apply the caulk completely around each alignment pin.
Lift the side wall and place it on the pan. Make sure alignment pins on the pan and back wall line up. Clear
ngers and slide the wall into the installed position.
Installation Instructions
Conrm t and level. Inspect that the grout lines on the
side wall match up with the grout lines on the back wall. Using a grease pencil or china marker to make a short line across the grout lines makes it easier to see if the grout lines are in alignment.
Pre-drill mounting anges and attach to framing studs with
screws. Make sure wall panel remains level and plumb and the seam is tight.
Repeat the procedures in Step 22 for opposite side wall.
24. Now that all wall panels are installed, remove the
protective cardboard from the oor and use a 2 foot level to re-check the downward oor draft to the drain. Use the same procedure as described in Step 18 of this manual.
25. Install the rubber caulking gasket around the drain pipe.
Trim the length of the pipe if necessary. Apply soap to the
caulking gasket to lubricate it. Place the caulking gasket on the drain pipe and press it down into the drain assembly
until it seats. Snap the strainer plate onto the drain.
Pour water across the oor to conrm good draft to the
drain so the water drains completely with no puddling. Make certain the drain does not leak.
Note: The manufacturer and supplier of this product is not responsible for leaking drain conditions. Proper installation
of the drain tting and pipe is the installers responsibility.
Since there is minimal oor slope to the drain, it is
critical factory slope be maintained so the shower drains
well. To accomplish this, temporary bracing must be put in place to assure the oor remains in the proper position as
the adhesive cures.
Before installing the bracing, place a padded piece of wood on the top center of the threshold and directly on top of the drain. Pad the wood with soft cloth or cardboard to
prevent damage to the nish.
Install temporary 2 x 4 stud bracing so they sit on top of
these wood pieces. Attach these studs to the room framing above the shower, or pad to the ceiling. See Figure 26
26. Remove the temporary bracing after 72 hours. Place a piece of cardboard in the shower to protect the nish.
Caulk all seams with white acrylic bathtub caulk.
Page 10
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Installation Instructions
SEAM CAULKING INSTRUCTIONS
Materials and tools required:
• acrylic latex caulk
• wiping cloths/rags
• clean water
• caulking gun
• cup
1. Cut off tip of caulk tube diagonally with opening
no larger than 1/8”. Figure 27
2. Run a continuous bead of caulk at the seam between
the two parts. Figure 28
3. Smooth caulk gently with a wet ngertip. Figure 29
4. Using a clean rag, wipe off excess water and caulk.
Figure 30
Figure 27
Figure 26
Figure 28
Figure 29
Figure 30
Page 11
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
INSTALLATION INSTRUCTIONS FOR SHOWER SEATS WITH SWING DOWN LEGS
(This style seat has four (4) adjustable height legs)
Your seat with swing down legs is fully assembled. Remove it from the box and proceed as follows:
1. Choose the height of the seat you want. Barrier Free style showers will typically have fold up seat installed at
17” to 19” height.
2. After selecting the height you desire, adjust each of the four legs to that height while maintaining the seat in a level position. Lock each of the lock nuts.
3. Place the seat against the wall of the shower where
you want the seat to be located. Seat may be centered
on the wall for a Barrier Free installation.
4. With the seat placed against the mounting wall, position the two hinges to the wall. Using a pencil, mark
the three holes (3) holes in the ange onto the wall for
each hinge. Remove seat from wall.
5. Using a power drill with a 0.120” diameter drill through the wall the three (3) mounting holes for each ange.
6. Apply silicone caulking around and inside each drilled hole before installing the seat.
7. Place the seat against the mounting wall with each
hinge aligned to the mounting holes. Utilizing the six (6) #10 x 2” Stainless Steel screws, place a Phillips screw
driver into your power drill and securely tighten each of
the six (6) screws.
THIS COMPLETES THE INSTALLATION OF THE SEAT
INSTALLATION INSTRUCTIONS FOR GRAB BARS
Recommended tools for installation: 1/4” Power Drill
1/8” drill bit when drilling through berglass
#2 Phillips Screw Driver and/or Phillips drill insert 1/2” Open end wrench or a small Crescent wrench Tape measure Pencil/pen Center Punch Silicone Caulk
Installation Instructions
1. As indicated earlier in this manual, wood reinforcements must be solidly installed behind the tile wall surface to provide a secure mounting surface to attach the grab bars. Grab bars must be installed at these locations only.
2. Select the particular size and style of grab bar you want to install. Certain grab bars have snap in place ange covers, and others have exposed anges.
3. For grab bars with snap in place ange covers, use the
handle of a Phillips screw driver to tap back the covers on the bottom edge of the covers. It will be convenient in the installation process if the covers are tapped together in the center of the grab bar.
4. Determine the position you want the to install the bar.
Place the bar against the wall. Using a pencil, mark the location of each mounting hole at both ends of the bar.
5. Using a power drill with a 1/4” diameter carbide tipped drill
bit, drill, each mounting hole.
6. Apply silicone caulking around and inside each drilled hole before installing the grab bar.
7. Take two (2) of the #10 x 2” Stainless Steel screws. By
hand, start one mounting screw in each end of the bar into the wall.
8. Use a power drill with a Phillips drill bit to fully install these mounting screws.
9. Take the remaining #10 x 2” screws and place them into
the remaining open holes. Use care to snug up the screws, but to not over-torque that the screws strip out the factory installed backer board.
10. If installing a bar with snap-on covers, move the covers
into place at each ange. Twist the covers clockwise or counter clockwise to tighten the covers onto the anges.
THIS COMPLETES THE INSTALLATION OF THE GRAB BAR
Page 12
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
INSTALLATION INSTRUCTIONS FOR COLLAPSIBLE WATER RETAINERS
Important considerations before you begin: Most manufactured units are designed with a radius where
the oor transitions or meets the wall. This is to
ensure proper structural strength where the wall
meets the oor. The installation of end caps is highly recommended on radius models for proper t and nish. The caps will also help to keep your curtain inside
the water barrier. A properly sized curtain with heavy tape weights combined with a water retainer is the most complete and effective system available today.
Installation of radius models: (For Finished End Cap Installation) Make sure you have ordered the correct
length. See chart below. The water retainer strip is designed to travel along the oor to the wall radius
until vertical, then capped. (Less Cap Installation) Cut the retainer strip to the shape of the radius where
the wall and the oor meet, then caulk. Caps are not required in applications where a 90-degree corner is
standard.
Size Verication Chart for all Factory Manufactured
Shower Units
For most Acrylic Showers:
• 36” ADA barrier free (36”I.D. opening) 42CWR-White
• 48” barrier free (45-46” I.D opening) 52CWR-White
• 60” ADA barrier free shower (60” I.D. opening) 66CWR-White
• Finished End Cap CWRCAP-White
Note: 1 ½” wide at mounting surface required.
Identifying proper mounting location: It will be helpful to determine whether your Gel-coat or Acrylic reinforced shower unit model has a small molded ridge or “water
runoff assist” or trench design on your unit. You will nd this feature on the oor of approximately 1-3
Installation Instructions
inches from the front entry edge of your shower unit.
The inside edge of the water retainer should rest on
the crown of the ridge allowing the water to run off properly. Use this ridge as your guide to mounting the retainer parallel with the water run off ridge.
Models less the ridge: All name brand barrier free showers that may not have a water run off ridge or recessed trench and applications such as tile, marble
or cement oor surfaces, purchaser must determine the proper mounting location and length. Helpful hint:
determine by desired location of curtain or directly below curtain rod.
Tools & Materials required: Utility Knife, Tape measure, Straight edge, Clear or White 100% Silicone Adhesive
caulk, Blue Masking tape, Rubbing Alcohol, bucket of water and clean rags.
INSTALLATION STEPS WITH FINISHED END CAPS
1. Thoroughly clean threshold surface of all soap scum
and debris using standard bath cleanser. Chemically clean surface with rubbing alcohol.
2. Verify the required length anticipating the vertical rise, making certain there is enough retainer strip to make a vertical rise on the end walls.
3. Determine and mark center point of shower.
4. Determine and mark center point of water retainer
strip.
5. Turn over water retainer strip and make cut on
orange peel off strip at half way mark. Peel off a
portion (approx. 4”) of the orange peel off strip in one
direction exposing the adhesive.
6. Align strip with pre-determined pencil mark or molded ridge crown of shower unit starting at the half
way mark. Press on and adhere approximately 4” of
strip. Pull and stretch to wall and align before removing remainder of orange peel off strip. Press into place.
7. Peel, stretch, alien and pull remaining half to wall. Press into place.
Page 13
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
8. Push in the male end of your end cap into the water retainer. Adhere end cap to unit with adhesive caulk and wipe clean. White or clear adhesive type caulk is recommended.
9. Use masking tape to temporarily hold cap in place until adhesive cures.
10. Optional: The outer edges beneath the retainer
may be caulked if desired to prevent soap and shower
debris from lodging beneath the retainer. The adhesive
tape does not extend to the edge (by design) to allow the retainer to absorb the impact energy of a rolling shower chair in high use applications. Wipe off excess
caulk and let cure (according to caulk specications)
prior to shower use.
STEPS LESS FINISHED END CAPS
Installation Instructions
11. Caulk end cuts and wipe clean. A silicone adhesive caulk is recommended.
12. Optional: The outer edges beneath the retainer
may be caulked if desired to prevent soap and shower
debris from lodging beneath the retainer. The adhesive
tape does not extend to the edge by design to allow the retainer to absorb the impact energy of a rolling shower chair in high use applications. Wipe off excess
caulk and let cure (according to caulk specications)
prior to shower use.
1. Thoroughly clean threshold surface of all soap scum
and debris using standard bath cleanser. Chemically clean surface with rubbing alcohol or equal.
2. Verify the required length anticipating the radius shaping required on each end of the strip.
3. Determine the shape of the end cut required for proper t and nishing.
4. Begin at one end only.
5. Create template of wall shape (if necessary) with
cardboard or material of choice.
6. Trace shape onto retainer, cut and trim with utility
knife.
7. Beginning on the shaped end, peel back a small 4”
section of the orange peel off strip.
8. Align strip with pre-determined pencil mark or molded ridge crown of unit. Press on and adhere the
4” section of exposed strip into place.
9. Before removing remainder of orange peel off strip, stretch retainer to opposite wall, mark and template for
proper location proceeding nal cut.
10. Remove remaining orange peel off strip and stretch
retainer to its nal position. Press and adhere into
place.
Page 14
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Installation Instructions
Page 15
Multi-Piece Sectional Product
Marketing Materials
Pricing
www.freedomshowers.com
Installation Instructions
Copyright 2015 FRE/0515/6MAN109FRDM
Page 16
Marketing Materials
Pricing
www.freedomshowers.com
Installation Using Epoxy Adhesive
1. Ensure the stud pocket is the correct dimension, including the location of the drain hole and recessed cut out.
2. Ensure the fl oor is level and free of any debris, including
dust and dirt (will impair adhesion).
3. Install the drain fi tting and prepare the drain pipe.
4. Place the pan/shower into the pocket and check for proper level and alignment. Adjust accordingly.
5. Dry fi t all walls as stated in the standard installation
instruction (for sectional models only).
6. Mark the location and prepare the pan/shower as stated in the standard installation instructions.
7. Tilt pan out of the way or remove the shower and apply adhesive in the following manner: a. Apply adhesive in small mounds ¾” in height.
b. Mounds must be NO MORE than 6” apart and
applied in a grid-like manner.
c. Place adhesive over entire pocket surface,
beginning at the back and working toward the
front.
d. Ensure material is applied near the drain cutout/
box out.
8. Place pan/shower back into position and ensure it is level.
9. Apply a small amount of adhesive between two pieces of scrap material. This will be checked later to verify
set time.
10. Secure the unit as stated in the standard installation instructions.
11. Allow 2 hours minimum for the adhesive to set.
Verify by checking the scrap pieces from step 9.
12. Continue the installation as stated in the standard installation instructions.
Copyright 2015 FREEPOXY/0715