Frankford Arsenal Precision Powder Scale User Manual

Precision Powder Scale
Precision Powder Scale
Product #909672 Instructions #1028773
USER MANUAL
Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service.
• Never load the scale with more than the maximum capacity. Overloading can permanently damage unit.
• Handle with care. Gently apply all items to be weighed onto tray top. Although this scale is designed to be quite durable, try to avoid rough treatment as this may permanently damage the internal sensor
• Avoid shaking, dropping or otherwise shocking the scale. This is a precision instrument and must be handled with care.
TROUBLESHOOTING
e primary reasons for inaccuracy or malfunction are low batteries, incorrect calibration, overload or operating on an unstable surface. Please keep these in mind and maintain and operate your scale properly. e scale is a precise instrument and must be handled with care and caution.
Display Elimination of errors
Nothing Battery-symbol, [lo] or [8888] Change the batteries.
[OUT2] Recalibrate the scale as shown above.
[O-LD] You are overloading the scale. Remove the excessive load immediately!
[LLLLL] e delicate weighing load cells have been damaged by misusing the scale (i.e. it was shocked, dropped or overload.) You can try recalibrating the scale. If the load cell has not been damaged it will work again aer recalibration.
[UNST] Use the scale in a more stable position
CONTENTS
A. Precision scale B. 2 calibration weights C. Powder pan D. Podium
E. Clear cover F. Storage case (NOT SHOWN) G. 110V power supply H. 220V adaptor
A.
B.
C.
D.
E.
G.
H.
e Platinum Series Powder Scale is a very precise measuring instrument. We recommend using the scale on a at and sturdy table top in a clean environment. e presence of dirt, dust, moisture, vibrations, air currents or use in close proximity of other electronic devices can cause adverse eects on the reliability and accuracy of the scale. It is also recommended to avoid exposing the scale to extreme heat or cold, the scale works best when operated at normal room temperature. For the best results we recommend calibrating the scale every reloading session. (See Calibration Instructions below) Aer powering on wait 30-60 seconds to allow internal components the chance to stabilize before calibrating.
1. Press POWER button.
2. Wait 1 minute for internal components to stabilize.
3. Calibrate the unit if desired.
4. Wait until [0.000] is displayed.
5. Put the object (s) on the weighing platform.
6. Using the UNITS button, you can switch between weighing units.
OPERATION
1. Turn on the scale as described above.
2. Place the “tare item” on the platform.
3. Press ZERO button quickly and [0.000] is displayed.
4. Add the “net-weight-item”.
TARE WEIGHTING
1. Press POWER button to turn on the scale. (Wait 30-60 seconds)
2. Wait until “0.000” is displayed, press and hold CAL button for two seconds. It will display and ash “CAL”.
3. en the LCD will ash 0.000 rst to set zero point, for which you don’t need to put any weight on the platform. Aer two seconds, it will ash the second weight 50.000, place the required weight onto the platform, and then it will ash the third weight 100.00, place the required weight onto the platform.
4. e display will show “PASS” and return to normal weighing mode. Calibration is complete.
NOTE: Repeat this process if PASS is not displayed.
CALIBRATION
Capacity: ......... 1543.2gn/100g/3.527oz/500.00ct
Readability: ....... 0.1gn/0.01g/0.001oz/0.05ct
Units: ............ gn/g/oz/ct
Auto o time: ..... 180 seconds
Operation temp: ...10C-30C
SPECIFICATIONS
Power: ........... 4x ‘AAA’ Batteries (not included)
Or .............. AC to 5V adapter (included)
Dimensions: ...... 200 x 125 x 60mm
Weight: ........... 540g