Franke Foodservice FDMO 607 I Installation Manual

Instructions for use and installation
Mode d’emploi et installation
Bedienungsanleitung und Einrichtung
Kullan
ım ve montaj talimatları
GB
IT
FR
DE
TR
Cooker Hood
Cappa
Hotte de Cuisine
Dunstabzugshaube
Davlumbaz
FDMO 607 I
EN
Instructions Manual INDEX
RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................7
CHARACTERISTICS..............................................................................................................................................................8
INSTALLATION ....................................................................................................................................................................10
USE.......................................................................................................................................................................................14
MAINTENANCE....................................................................................................................................................................15
2
2
EN
RECOMMENDATIONS AND SUGGESTIONS
650 mm min.
The Instructions for Use apply to several versions of this appliance. Accord-
ingly, you may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for an y damages resulting fro m incor­rect or impro per installat ion.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm.
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
• For Class I appliances, check that the domestic power supply guarantees ade­quate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter
120 mm. The route of the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fi replaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clea n air.
USE
• The extractor hood has been designed exclusively for domestic use to elimi­nate kitchen smells.
• Never use the hood f or purposes other than for which it has ben designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• Do not flambè under the range hood; risk of fir e
• This appliance is not intended for use by persons (including children) with re­duced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appli­ance.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
• Clean and/or replace the Filters after the specified time p eriod.
• Clean the hood using a damp cloth and a neutral liquid deter gent.
7
7
EN
CHARACTERISTICS
24
15
29
9
2
12c
1
25
14
11
12h
21
23
22
7.1
7.1b
7.1a
12g
12f
26
12w
13
Components
Ref. Q.ty Product Components 1 1 Hood Body, complete with: C ontrols, Light, Blower, Filters 2 1 Upper Chimney
7.1 1 Telescopic f rame complete with extrac tor, consist ing of:
7.1a 1 Upper frame
7.1b 1 Lower frame
9 1 Reducer Flange ø 150-120 mm 13 1 Gasket 14 1 Hood Body Air Out let Extension Piece 15 1 Air Outlet Connection 25 2 Pipe clamps 26 1 Fixing Part of the upper Chimney 29 1 Air outlet connection tube
Ref. Q.ty Installation Components 11 4 Wall Plugs ø 10 12c 4 Screws 2,9 x 9, 5 12f 4 Screws M6 x 15 12g 4 Screws M6 x 80 12h 4 Screws 5,2 x 70 12w 2 Screws M3 x 8 21 1 Drilling template 22 4 6.4 mm int. dia washers 23 4 M6 nuts 24 2 Fixing knobs f or the air outlet connection piece
Q.ty Documentation
1 Instruction Manual
8
8
EN
Dimensions
**
*
* Dimensions of the hood in ducting version. ** Dimensions of the hood in recycling version.
9
9
Loading...
+ 9 hidden pages