Franke Foodservice 2-Drawer Refrigerator 18008670 Parts List

TECHNICIAN’S QUICK REFERENCE GUIDE -
2 DRAWER REFRIGERATOR
DOCUMENT PART NUMBER 19010014 REV A, 02-22-17
PART #:
18008670
(For other units, verify compatibility of parts with Technical Support before ordering)
SERVICE PARTS
1 19006013 Compressor, Copeland 134a 1
2
3
4 19003255 Switch, Illuminated Red Rocker, DPST 1
5 19000152 Switch, Refrigerant Pressure Cutoff 1
6 19006009 Condensing Fan, AC Cooling, 115/60 1
7 19006008 Evaporator Fan, AC Cooling, 115/50-60 1
8 19007721 Tubing, Copper Capillary, 49" 1
9 19006023 Evaporator, 10-3/4"W x 6-1/8"D x 5-3/8"H 1
10 19004167 Slide, S/S Drawer, Set of (2), 17-3/4" 2
11 19006027 Gasket, Finishing Station Door 2
12 19000817 Caster, Swivel with Brake, Plate 4
13 19000801 Cord Set, 10' with Plug, 15 Amp, 120/60/1 1
14 18008082 Controller, Eliwell 1
15 19004832 Sensor, Coil Temperature, 2M IP68NTC 1
16 19004769 Sensor, Air Temperature, 2M IP68NTC 1
Contact Technical Support
Contact Technical Support
Relay, Start 1
Capacitor, Start 1
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc. 800 Aviation Parkway Smyrna, TN 37167, USA Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
www.frankefs.com
CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) 2 Drawer Refrigerator
Temperature Controller Options
Temperature Range Adjustable
Coldest Set Point (Midpoint) 33.0°F
Normal Cut Out 33.8°F
Normal Set Point (Midpoint) 37.4°F
Normal Cut In 41.0°F
Warmest Set Point (Midpoint) 41.0°F
Compressor Protection Fixed
Minimum On Time 2 minutes
Minimum Off Time 2 minutes
Fail Safe Mode (if sensor fails) Fixed
Error On Time 4 minutes
Error Off Time 6 minutes
Defrost Settings Fixed
Termination Temp 41.0°F
Maximum Time Allowed 60 minutes
Drip Time (heat off) N/A
Defrost Based On Compressor On Time Fixed
Time Between Defrosts 5 hours
Fan Settings Fixed
During Defrost On
Start Delay After Defrost N/A
Start Delay 1 minute
Display Features Adjustments
Can select degrees F or C? No
Can adjust temperature from display? Yes
Can Initiate Defrost from display? Yes
Display During Defrost Cycle:
Refrigerant Type Amount, Ounces
R-404A 2 Drawer 8.5 oz
dEF
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 115 PSIG 2 Drawer 4 Amps
Low Side (-5 box temp) 17 PSIG
High Pressure Safety Rated Operating Amps
Cut Out Setting N/A 2 Drawer 4 Amps
Differential N/A
Defrost High Limit Safety Operating Voltage
Cut Out Setting N/A 2 Drawer 120V
Differential N/A
© 2017 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form of media without the express written permission of Franke. Due to continuous product development, Franke reserves the right to make changes in design and specifications without prior notice. Trademarks used are the property of their respective owners. Printed in the USA under license by Franke Technology and Trademark Ltd., Switzerland.
For Support, Please Call: Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2
Loading...