Franke KER1P Installation Instructions And User Manual

Page 1
KER1P watER filtRation
UndER SinK ChillER Unit
inStallation inStRUCtionS and USE and CaRE GUidE
This chiller unit is not a water purifier. Use with the KER1P under sink modular system that includes three types of filter units and a choice of faucets sold separately.
When sold with Pro1 and Pro2 system.
For questions about features, suggested retail price, operation/ performance, parts, accessories or service, call: 1-866-687-7465.
Or visit our website at: www.franke-commercial.com
CERTIFIED TO NSF/ANSI 61
TABLE OF CONTENTS
2 ChillER SafEtY
2 aSSiStanCE oR SERViCE
3 inStall ation REQUiREMEntS
3 Tools and Parts
4 Location Requirements
4 Electrical Requirements
5 Water Supply Requirements
5 inStall ation inStRUCtionS
5 Install the Chiller
6 ChillER USE
6 Setting the control
6 Draining the Chiller
6 Reconnecting the Chiller
7 BEfoRE CallinG foR SERViCE
7 tRoUBlEShootinG
8 ChillER waRRantY
10112 036865-012
Page 2
2 036865-012 0112 30112 036865-012
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
ChillER SafEtY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING". These words mean:
You can be killed or seriously injured if you don’t immediately follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
DANGER
DANGER
WARNING
aSSiStanCE oR SERViCE
If you need assistance or service, first see “Troubleshooting” section. Additional help is available by calling 1-866-687-7465 or write:
Franke Kindred Canada Limited 1000 Franke Kindred Road Midland, ON L4R 4K9 CANADA
Please include a daytime phone number in your correspondence. For installation and service, call: 1-866-687-7465 or visit our website at
www.franke-commercial.com.
Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in­warranty service. Write down the following information about your appliance to help you obtain assistance or service if you need it. You
will need to know your complete model number. You can find this information on the model and serial number label.
DEALER NAME _______________________________________________________________________________________________
ADDRESS ___________________________________________________________________________________________________
PHONE NUMBER ______________________________ MODEL NUMBER _______________________________________________
PURCHASE DATE _____________________________________________________________________________________________
inStallation REQUiREMEntS
IMPORTANT: Observe all governing codes and ordinances. Check location where the chiller will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with installation specifications and with state and local plumbing codes. Water connections use easy to connect fittings that do not require sealing compounds to keep them from leaking.
toolS and PaRtS
1
2
4
3
5
6
7
8
Tools Needed
A, Pencil B. Measuring tape C. Utility knife
Parts Supplied
1. Under sink Chiller unit
2. 4 feet of blue tubing
3. 2 easy to connect elbows
4. 2 “T” quick connect fitting
5. Check valve
6. 4 feet of white tubing
7. 1 wall mounting clip
8. 1 Phillips screw #7
Page 3
4 036865-012 0112 50112 036865-012
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
loCation REQUiREMEntS
IMPORTANT: Faucet is sold separately and requires a 1 3/8" (3.5cm) diameter opening in sink or countertop. Spout can be installed in place of sink spray hose. If faucet is not to be installed in sink spray hose opening, it is recommended that a qualified installer be contacted to drill a hole through your type of sink or countertop. Thickness of countertop at the hole must not exceed 1 3/4" (4.4cm) . For best performance, allow a 2" (5 cm) space around the side and the top. Do not put any objects on top of the chiller that could obstruct the fan.
3
2
1
4
5
6
7
8
9
5
01
11
21
21
31
14.75
"
[37.47 cm]
10.30
"
[26.16 cm]
8.72
"
[22.14 cm]
1. Chiller unit
2. Blue tubing included with chiller
3. Faucet is required (sold separately)
4. Cold water supply line
5. White tubing included with faucet
6. Dual filtration sold separately
7. Unit C sold separately
8. Flow monitor included with faucet
9. “T” water line connector included with faucet
10. White “water in” collet
11. Blue “water out” collet
12. “T” quick connect fitting
13. Check valve
ElECtRiCal REQUiREMEntS
A 120-volt, 60-Hz, 15- or 20-amp, grounded electrical supply is required. It is recommended that a separate circuit serving only your chiller unit be provided. Use an outlet that cannot be turned on/off by a switch.
RECOMMENDED GROUND METHOD - The chiller must be grounded. This appliance is equipped with a power supply cord with a 3 prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, ground-type outlet, grounded in accordance with all national and local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3 prong outlet installed by a qualified electrician.
WARNING
ELECTRICAL SHOCK HAZARD
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result in death, fire, or electrical shock.
watER SUPPlY REQUiREMEntS
If local codes permit, the chiller feed line should be connected to the cold water supply line with the “T” water line connector included with the faucet (sold separately). If you are using a filtration unit, the chiller should be connected after the filtration unit.
IMPORTANT: If local codes do not permit the use of the “T” water line connector, special feed valves can be obtained from your local plumbing supply retailer. The water pressure to the chiller should be between 30 psi (MIN) and 100 psi (MAX).
inStallation inStRUCtionS
inStall thE ChillER
NOTE: Tubing must be cut to fit. All tubes must be cut squarely with no burrs. All tubing connections must be fully seated. Tubing must be routed to avoid sharp bends and have enough slack to avoid straining connections. A P-clip and mounting screw is included to hold the tubing in place as needed. Pull gently on each connection to make sure they are secure.
IMPORTANT: After chiller is unpacked, place chiller upright for 24 hours before plugging it in.
1. Determine where you will install your chiller. See “Location Requirements” section.
2.
For best performance, allow a 2" ( 5 cm) space around the side and the top.
Do not put any objects on top of the chiller that could obstruct the fan.
3. Shut off water supply valves.
4. Install KER1P faucet sold separately. See faucet’s Installation instructions.
5. Using the white tubing included with the faucet (sold separately), connect one end to the chiller (water in) and the other end to the flow monitor outlet (blue collet) . (See Figure 1)
NOTE: If you are installing the chiller with a filtration system, follow steps 6a. to 13. Following these steps will avoid the possibility of excessive pressure building as the chilller cycles on and off. If you are NOT installing t he chiller with a filtration system, follow steps 6b. and 10 to 13.
6a. Connect “T” (part 12) to “water out” chiller tube. Connect blue tubing between “T” and faucet, sold separately. (see Figure 2)
6b. If you are NOT installing a filtration system, connect blue tubing between the “water out” chiller tube and faucet, sold seperately. Do NOT use “T” quick connect fittings (part 12) or check valve (part 13).
How to insert/remove tubing
in easy connect fitting
Insert the tubing squarely. See Figure A. Make sure to insert tubing completely. See Figure B. Push in collet and pull out tubing See Figure C.
Figure A Figure B Figure C
Tube Collet
Body
Check valve
(part 13)
White tubing
to check valve
Blue tubing to faucet
T” Quick connect fitting (part 12)
Connection to Chiller “water out”
Check valve inlet
part 12
part 13
part 9
part 12
How to insert/remove tubing
in easy connect fitting
Insert the tubing squarely. See Figure A. Make sure to insert tubing completely. See Figure B. Push in collet and pull out tubing See Figure C.
Figure A Figure B Figure C
Tube Collet
Body
Check valve
(part 13)
White tubing
to check valve
Blue tubing to faucet
T” Quick connect fitting (part 12)
Connection to Chiller “water out”
Check valve inlet
White tubing to filtration system
T” Quick
connect fitting
(part 12)
White tubing to part 9
Check valve
(part 13)
White tubing
Check valve
(part 13)
White tubing
to check valve
Blue tubing to faucet
“T” Quick connect fitting (part 12)
Connection to Chiller “water out”
Check valve inlet
Figure 1
Figure 2
Page 4
6 036865-012 0112 70112 036865-012
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
KER1P watER filtRation
UndER S inK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUi dE
7. Cut 6 inches of white tubing. Connect one end to “T” (part 12) that is connected to “water out” chiller tube and other end to check valve inlet (see Figure 2)
8. Cut white tubing between the “T” water line connector (part 9) and the white “water in” collet of the filtration system. Connect the straight thru ports of the second “T” (part 12) to the loose ends of the white tubing just cut. (see Figure 3) Connect white tubing included with chiller between the third port of the second "T" (part 12) and check valve outlet (see Figure 3).
9. Slowly turn on water supply valve. Depress faucet lever until water flows for about one minute. Check all connections for leaks.
10. Plug in chiller.
11. Prior to drinking water from chiller, flush water through chiller for at least 5 minutes.
Check valve
(part 13)
White tubing
to check valve
Blue tubing to faucet
T” Quick connect fitting (part 12)
Connection to Chiller “water out”
Check valve inlet
White tubing to filtration system
“T” Quick
connect fitting
(part 12)
White tubing to part 9
Check valve
(part 13)
White tubing
ChillER USE
SEttinG thE ContRol
- Your chiller has a dial for water temperature control.
- For colder water: Turn it clockwise (to the right).
- For less cold water: Turn it counterclockwise (to the left).
- To shut down the chiller: Turn the dial to the Off position at full counterclockwise (extreme left).
- Allow one hour to obtain chilled water.
dRaininG thE ChillER
1. Unplug the chiller.
2. Shut off water supply to chiller.
3. Open faucet to release pressure.
4. Disconnect the water lines attached to the chiller by depressing collet on easy to connect fittings.
5. Tip chiller to the left side (power cord side) and drain water into a large container.
6. Set chiller in its normal upright position for storage.
7. If the water system is to be used without the chiller in place, connect the blue faucet tubing to the flow monitor.
REConnECtinG thE ChillER
1. Shut off water supply to chiller.
2. Put chiller back in position, allowing a 2" (5 cm) space around the side and top.
3. Connect water lines as described in the ‘’Install the Chiller’’ section.
4. Slowly open main water supply valve and open faucet until water flows.
5. Plug in chiller and set dial to desired water temperature (See the “Setting the Control” section).
BEfoRE CallinG foR SERViCE...
If the chiller does not operate, check for these conditions first:
- Has the circuit breaker tripped or has a house fuse blown?
- Is the Temperature Control set to the “Off” position?
- Is the power supply cord plugged into a grounded 3 prong outlet?
- Has the water supply been turned off?
- Is the electrical outlet controlled by a switch?
tRoUBlEShootinG
PRoBlEM ChECK thE followinG
Water is not cold.
- Check that the circuit breaker has not tripped or the house fuse has not blown.
- Check that power supply cord is plugged into electrical outlet.
- Check if the electrical outlet is operated by a switch. The switch may have turned the power off.
- Cold water in tank is still being chilled. Wait 15 minutes and check temperature again.
- Check that the Temperature Control is set to the “Max” setting.
Cold water drips or sputters from spout.
- Check that tubing is not bent or kinked.
Water does not flow from spout.
- Make sure main supply valve is open.
- Check the flow monitor reading on faucet. Green light is good, yellow light is fair and red light indicates filter change.
- Check that water pressure to the chiller is 30 psi (138 kPa) minimum.
- Check to see if chiller is attached to hot water line. If so, attach to cold water line.
- Check filters for proper installation.
Unpleasant taste.
- If the dispenser has not been used for 3 or more days or if only 1 to 3 cups of water are dispensed in a day, the tank may need to be purged. Open the faucet for 2 to 3 minutes to purge the old water from the tank. Allow new water in tank to reach desired temperature (approximately 1 hour) before dispensing water.
- Check the flow monitor reading on faucet. Green light is good, yellow light is fair and red light indicates filter change.
Figure 3
Page 5
KER1P watER filtRation
UndER SinK ChillER Unit inStallation inStRUCtionS and USE and CaRE GUidE
ChillER waRRantY
Warrantor: Franke Kindred Canada Limited, 1000 Franke Kindred Road, Midland, ON L4R 4K9, CANADA
onE-YEaR liMitEd waRRantY
The Warrantor promises the original purchaser to repair or replace, at the Warrantor’s option, any part of this KER1P Chiller unit that proves to be inoperative due to a defect in material or workmanship under normal use, for a period of one (1) year from the date of purchase. This warranty will be honored provided the KER1P Chiller unit has been installed and operated in accordance with the written instructions furnished with the KER1P Chiller unit.
GEnERal PRoViSionS and EXClUSionS
This warranty applies only within Canada and the United States of America. This warranty will be honored if the unit is returned in the original carton (or suitable replacement) along with proof of purchase. This warranty does not apply to bonus and/or accessory items sold with the KER1P Chiller unit. This warranty does not apply if the affixed serial number is removed, defaced or obliterated. This warranty does not cover poor performance, failure or damage of any part resulting from external causes such as alterations, abuse, misuse, misapplication, corrosion, liming conditions or acts of God. This warranty and the Underwriter’s Laboratory or Canadian Standard Association listing for this KER1P Chiller unitare automatically voided if this KER1P Chiller unit is altered, modified or combined with any other machine or device. Alteration or modification of this KER1P Chiller unit may cause serious flooding, and/or hazardous electrical shock or fire.
Except as set forth herein or required by law, the Warrantor makes no other warranty, guarantee or agreement, express, implied or statutory, including any IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The Warrantor does not assume or authorize any person to assume any obligations of liability in connection with this product. In no event will the Warrantor be liable for indirect, special or consequential damages (including, without limitation, economic loss) or for any delay in the performance of this agreement due to causes beyond its control. Some states or provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or from province to province.
If you need service, first see Troubleshooting Solutions. Additional help can be found by checking Assistance or Service or by calling our customer service line at 1-866-687-7465 or by writing: KER1P filtration system, Franke Kindred Canada Limited, 1000 Franke Kindred Road, Midland, ON L4R 4K9, CANADA
Franke Kindred Canada Limited 1000 Franke Kindred Road Midland, ON L4R 4K9 CANADA
Tel. 1-866-687-7465 Fax 1-800-361-8408 www.franke-commercial.com
036865-012 0112